Gianni ML-605M Series Electro Mechanical Lock is a versatile and reliable locking solution for various applications. With its adjustable fail-safe or fail-secure mode, you can customize the lock to meet your specific security requirements. The lock's robust construction and extensive testing ensure durability and longevity.

The lock's compact design makes it suitable for narrow stile doors, while its adaptability to different backset options provides flexibility during installation. The built-in lock bolt sensor switch provides real-time monitoring of the lock's status, enhancing security and convenience.

Gianni ML-605M Series Electro Mechanical Lock is a versatile and reliable locking solution for various applications. With its adjustable fail-safe or fail-secure mode, you can customize the lock to meet your specific security requirements. The lock's robust construction and extensive testing ensure durability and longevity.

The lock's compact design makes it suitable for narrow stile doors, while its adaptability to different backset options provides flexibility during installation. The built-in lock bolt sensor switch provides real-time monitoring of the lock's status, enhancing security and convenience.

3-1
ML-605M Series Electro-Mechanical Lock
Copyright © All Rights Reserved. P-MU-ML-605 Published: 2022.08.10
Unit: mm
1
2
Installation Instruction
Dimension
Specification
Packing Contents Stud Bolt Position
Lock Bolt
Nib
Strike Plate
Euro profile
key cylinder hole
Caution:
Do not completely remove screw 2 (as marked in the figure)
as the interior solenoid might fall off.
Version Changeable:
Take out the Screw 1 , release screw 2 , move the
position and then tighten both screws.
“Fail-Safe”
(Power to Lock) “Fail-Secure”
(Power to Open)
For fail-safe mode
For fail-secure mode
Operating Voltage: 12~24VDC/AC ±10%
Current Draw: 250mA/12VDC; 150mA/24VDC
Operating Temperature: 14°F to 120°F (-10°C~+49°C)
Humidity: 0~85% non-condensing
Version Changeable: Fail-safe or Fail-secure
Lock bolt sensor switch output: SPDT, 3A/125VAC
Latch Throw:16mm
Solenoid testing: Tested to 250,000 cycles
Backset:
ML-605M-30: 30mm
ML-605M-35: 35mm
21 28
100
125
150
230
78
2
35
54
Backset
114.5
250
275
21 28
100
125
150
230
78
2
30
49
Backset
114.5
250
275
ML-605M-30 ML-605M-35
3
3
3-2
Copyright © All Rights Reserved. P-MU-ML-605 Published: 2022.08.10
5 6 78
1 2 3 4
25
275
250
150
100
28
150
Ø5.2
Ø5.2
ø5.2
310
275
Unit:mm
62mm cylinder for max 42mm door leaf
72mm cylinder for max 52mm door leaf
Installation Instructions
D
o
or
F
ram
e
D
o
o
r
l
e
a
f
(
C
y
lin
de
r
not
included
)
Door Loop
(Optional)
The door loop protects the wiring
from damage at the door hinge.
Attention! Please ensure
that the direction of the
template is correct
Alignment CL
F
r
a
m
e
D
o
o
r
Leaf
Align the center line (CL) of the lock body
lock body CL as closely as possible.
template with the CL of the door leaf. Ensure
the CL of the strike plate template matches the
Cut out mortise holes for the lock body and
strike plate and drill holes according to the
templates.
D
o
o
r
L
e
af
D
oo
r
L
e
a
f
D
oo
r
L
e
a
f
Tighten the fixing lugs with screws. Drill and cut the hole for the lock cylinders
as shown in the template.
D
oo
r
L
e
a
f
D
oo
r
L
e
a
f
D
oo
r
L
e
a
f
F
r
a
m
e
Connect power cable to the lock and test
before screwing to the door leaf. Attach the cover plates for the cylinder lock Install the cylinder Fix the strike plate.
Backset
30 (ML-605M-30)
35 (ML-605M-35)
Backset
30 (ML-310M)
35 (ML-315M)
3-3
12~24VDC/AC
Copyright © All Rights Reserved. P-MU-ML-605 Published: 2022.08.10
Wiring Diagram
For the 12~24VDC/AC operation only
Red
Red Varistor
NOTE: The varistor (or diode) must be connected across the terminals as shown above. This protects the
electromechanical lock from spikes and surges.
Butt Splice (IDC) Connector
Using crimper or pliers and pressing the header of
connector down to even position.
(Power input is polarity free)
Yellow
Green
Blue
Access Control
N.C. contact (Fail-safe mode)
N.O. contact (Fail-secure mode)
Lock bolt sensor switch output: SPDT, 3A/125VAC
  • Page 1 1
  • Page 2 2
  • Page 3 3

Gianni ML-605M Series Electro Mechanical Lock User manual

Category
Security device components
Type
User manual

Gianni ML-605M Series Electro Mechanical Lock is a versatile and reliable locking solution for various applications. With its adjustable fail-safe or fail-secure mode, you can customize the lock to meet your specific security requirements. The lock's robust construction and extensive testing ensure durability and longevity.

The lock's compact design makes it suitable for narrow stile doors, while its adaptability to different backset options provides flexibility during installation. The built-in lock bolt sensor switch provides real-time monitoring of the lock's status, enhancing security and convenience.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI