GW Instek GDM-8300 User manual

Type
User manual
Dual Measurement Multimeter
GDM-834X Series
USER MANUAL
REV. D
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
Table of Contents
3
Table of Contents
SAFETY INSTRUCTIONS .................................................. 5
GETTING STARTED ........................................................ 10
Characteristics .......................................... 11
Appearance ............................................... 14
Set Up ....................................................... 24
OPERATION .................................................................. 29
Basic Measurement Overview ................... 31
AC/DC Voltage Measurement ................... 33
AC/DC Current Measurement ................... 38
Resistance Measurement .......................... 43
Diode Test ................................................ 45
Capacitance Measurement ........................ 46
Continuity Test .......................................... 48
Frequency/Period Measurement ............... 50
Temperature Measurement ....................... 53
Dual Measurement Overview .................... 57
Advanced Measurement Overview ............ 62
dBm/dB/W Measurement ......................... 63
Max/Min Measurement ............................. 66
Relative Measurement .............................. 67
Hold Measurement ................................... 69
Compare Measurement ............................. 70
Math Measurement ................................... 72
SYSTEM/DISPLAY CONFIGURATION.............................. 76
View Serial Number .................................. 77
View Version Number ............................... 77
Brightness Settings ................................... 78
Beeper Settings ......................................... 79
GDM-834X Series User Manual
4
Input Resistance Settings ......................... 80
Frequency/Period Input Jack Settings ........ 81
Compatibility Settings ............................... 82
Restore Factory Default Settings ............... 83
USB STORE .................................................................... 84
USB Store Overview .................................. 85
REMOTE CONTROL ...................................................... 102
Configure Remote Control Interface ........ 103
Return to Local Control ........................... 106
COMMAND OVERVIEW ................................................ 107
Command Syntax .................................... 107
Command List ........................................ 112
FAQ .............................................................................. 143
APPENDIX .................................................................... 144
System Menu Tree ................................... 144
Factory Default Settings .......................... 145
Replacing the AC Source Fuse ................. 146
Replacing the Input Fuse ........................ 147
Status system ......................................... 149
Specifications ......................................... 150
Dimensions ............................................ 156
INDEX .......................................................................... 158
SAFETY INSTRUCTIONS
5
SAFETY INSTRUCTIONS
This chapter contains important safety instructions that you
must follow during operation and storage. Read the following
before any operation to ensure your safety and to keep the
instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the DMM or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
GDM-834X Series User Manual
6
Safety Guidelines
Make sure that the voltage input level does not
exceed DC1000V/AC750V.
Make sure the current input level does not
exceed 12A.
Do not place any heavy object on the
instrument.
Avoid severe impact or rough handling that can
lead to damaging the instrument.
Do not discharge static electricity to the
instrument.
Use only mating connectors, not bare wires, for
the terminals.
Do not block or obstruct the cooling fan vent
opening.
Do not perform measurement at the source of a
low-voltage installation or at building
installations (Note below).
Do not disassemble the instrument unless you
are qualified as service personnel.
Make sure that the COM terminal to earth is
limited to 500Vpk.
(Note) EN 61010-1:2010 specifies the measurement categories and
their requirements as follows. The GDM-834X falls under category II
600V.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
SAFETY INSTRUCTIONS
7
Power Supply
WARNING
AC Input voltage: 100/120/220/240 V AC
50/60Hz
The power supply voltage should not fluctuate
more than 10%.
Connect the protective grounding conductor of
the AC power cord to an earth ground, to avoid
electrical shock.
Fuse
WARNING
Fuse type: 0.125AT 100/120VAC
0.063AT 220/240 VAC
Make sure the correct type of fuse is installed
before power up.
To avoid risk of fire, replace the fuse only with
the specified type and rating.
Disconnect the power cord before fuse
replacement.
Make sure the cause of a fuse blowout is fixed
before fuse replacement.
Cleaning the
Instrument
Disconnect the power cord before cleaning.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Temperature: 0°C to 50°C
Humidity: 0~35°C: < 80%RH
>35°C: <70%RH
Altitude: <2000m
GDM-834X Series User Manual
8
(Note) EN 61010-1:2010 specifies the pollution degrees and their
requirements as follows. The GDM-8342/8341 falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of
dielectric strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
nor humidity is controlled.
Location: Indoor
Temperature: -10°C to 70°C
Humidity: 0~35°C: <90%RH
>35°C: <80%RH
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.
SAFETY INSTRUCTIONS
9
Power cord for the United Kingdom
When using the unit in the United Kingdom, make sure the power
cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed
as follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the
terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment
or contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable
of 0.75mm2 should be protected by a 3A or 5A fuse. Larger
conductors would normally require 13A types, depending on the
connection method used.
Any exposed wiring from a cable, plug or connection that is
engaged in a live socket is extremely hazardous. If a cable or plug is
deemed hazardous, turn off the mains power and remove the cable,
any fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.
GDM-834X Series User Manual
10
GETTING STARTED
This chapter describes the GDM-8342 and GDM-8341
multimeters in a nutshell, including accessories, and package
contents, their main features and front / rear panel introduction.
Characteristics ................................................................ 11
Accessories ................................................................ 12
Package Contents....................................................... 13
Appearance ..................................................................... 14
GDM-8342/8341 Front Panel .................................... 14
Display Overview ....................................................... 20
Rear Panel .................................................................. 22
GETTING STARTED
11
Characteristics
The GDM-8342 and GDM-8341 are portable, dual-display digital
multimeters suitable for a wide range of applications, such as
production testing, research, and field verification.
Performance
DCV accuracy: 0.02%
High current range: 10A
High Voltage range: 1000V
High ACV frequency response: 100kHz
Features
50000 count display
Multi functions: ACV, DCV, ACI, DCI, R, C, Hz,
Temp*, Continuity, Diode test, MAX/MIN, REL,
dBm, Hold, MX+B, 1/X, REF%, dB, Compare.
Manual or Auto ranging
AC true RMS
Data Logging to USB*
Data logging to PC using an Excel Add-In
Interface
Voltage/Resistance/Diode/Capacitance/
Temperature* input
Current input
USB device port as standard for remote control
USB host* for data logging
Optional GPIB* (factory install)
Calibration port (for service operators only)
Excel Add-In for easy-to-use remote control,
data logging and for saving/recalling setups
* These features are only available on the GDM-8342
Software
Excel Addins
USB driver
GDM-834X Series User Manual
12
Accessories
Standard
Accessories
Part number
Description
82DM-83420Ex1
User Manual CD
82DM-90610MA1x1
Safety Instruction Sheet
GTL-207A
Test leads: 1x red, 1x black
Optional
Accessories
Part number
Description
GDM-83G1
GPIB (Factory installed,
GDM-8342 only)
GTL-246
USB Cable
GTL-205A
Temperature Probe Adapter
with Thermal Coupling (K-
type)
GDM-TL1
Test lead probes with
CAT IV 600V sheath x 2
Fine tip probes x 2
SMT Grabbers x 2
Mini Grabber x 1
GTL-248
GPIB Cable, approx.
2,000mm
GRA-422
Rack Mount Kit (19” 2U)
GETTING STARTED
13
Package Contents
Check the contents before using the instrument.
Opening the box
Contents
(single unit)
Main unit
Test leads (red x1,
black x1)
Power cord x1 (region
dependent)
User manual CD
Safety instruction
sheet
GDM-834X Series User Manual
14
Appearance
GDM-8342/8341 Front Panel
Function keys and
Arrow keys
DC/AC 0.5A Terminal,
AMPS Fuse Holder
Power Switch, USB Host
port (GDM-8342 only)
Main
Display
DC/AC 12A
Terminal
COM
Terminal
V
Terminal
TEMP
DC + AC
Auto
CAT 600V
COM
250V
W
V
T0.5A
FUSE
INPUT
MAX
500Vpk
12A
MAX
750V
1000V
MAX
0.5A
MAX
USB STOINT/EXTCOMPMATHREL#
LOCAL
dBmdBACIDCI
50000 Counts Dual Measurement Multimeter
GDM-8342
POWER
Enter
RANGE
RANGE
SHIFT
EXIT
MENUTRIGHOLDMX/MNREL
2NDHz/P
/
W/
ACVDCV
W
Power Switch
POWER
Turns On or Off the main
power. For the power up
sequence, see page 25.
USB Host Port
The Host port is a type A USB port
for logging data. See the USB Store
chapter for more details, page 84.
Note: GDM-8342 only.
Main Display
Shows measurement results and parameters. For
display configuration details, see page 78 (light
setting).
For an overview of the main display, see page 20.
GETTING STARTED
15
W
V
Input
Terminal
CAT 600V
COM
250V
W
V
T0.5A
FUSE
INPUT
MAX
500Vpk
12A
MAX
750V
1000V
MAX
0.5A
MAX
This terminal is used for all
measurements except for DC/AC
current measurements.
COM Terminal
CAT 600V
COM
250V
W
V
T0.5A
FUSE
INPUT
MAX
500Vpk
12A
MAX
750V
1000V
MAX
0.5A
MAX
Accepts ground (COM) line in all
measurements.
The maximum withstand voltage
between this terminal and earth is
500Vpk.
DC/AC 0.5A
Terminal
AMPS Fuse
Holder
CAT 600V
COM
250V
W
V
T0.5A
FUSE
INPUT
MAX
500Vpk
12A
MAX
750V
1000V
MAX
0.5A
MAX
Low current measurement
terminal. Accepts DC/AC Current
input. For details see page 38.
DC: 500μA~0.5A
AC: 500μA~0.5A
As a fuse, protects the instrument
from over-current. Rating: T0.5A,
250V.(This terminal accepts
DC/AC current input)
For the fuse replacement
procedure, see page 147.
DC/AC 12A
Terminal
CAT 600V
COM
250V
W
V
T0.5A
FUSE
INPUT
MAX
500Vpk
12A
MAX
750V
1000V
MAX
0.5A
MAX
High range current measurement
terminal. Accepts DC/AC Current
input. For DCI or ACI details, see
page 38.
GDM-834X Series User Manual
16
Measurement
Keys
The top row of measurement keys are used for
basic DMM measurements such as voltage,
current, resistance, capacitance and frequency. The
bottom row of measurement functions are used for
more advanced functions.
Each key has a primary and secondary function.
The secondary function is accessed in conjunction
with the SHIFT key.
Upper Measurement keys
DCV
DCV
DCI
Measures DC Voltage (page 33).
DCI
(SHIFTDCV)
SHIFT
EXIT
DCV
DCI
Measures DC Current (page
38).
ACV
ACV
ACI
Measures AC Voltage (page 33).
ACI
(SHIFTACV)
SHIFT
EXIT
ACV
ACI
Measures AC Current (page
38).
DCV + ACV
DCV
DCI
+
ACV
ACI
Measures DC + AC voltage
(page 33).
DCI+ACI
SHIFT
EXIT
DCV
DCI
+
ACV
ACI
Measures DC +
AC current
(page 38).
GETTING STARTED
17
Resistance/
Continuity)
/
W
dB
Measures resistance or continuity,
depending on the selected mode.
See page 43 and 48, respectively.
dB
(SHIFT / )
SHIFT
EXIT
/
W
dB
Measures dB. See page 65.
Diode/
Capacitance
/
dBm
Tests diodes or measures
capacitance, depending on the
selected mode. See page 45 and 46,
respectively.
dBm
(SHIFT
/
)
SHIFT
EXIT
/
dBm
Measures dBm. See page 63
Hz/P
Hz/P
TEMP
Measures the frequency or period
of a signal, depending on the
selected mode. See page 50.
TEMP
(SHIFT Hz/P)
SHIFT
EXIT
Hz/P
TEMP
Measures temperature. See
page 53.
2ND
2ND
LOCAL
As the 2nd key, selects the
measurement item on the 2nd
display (page 57). Pressing and
holding for more than 1 second
turns off the 2nd display.
As the Local key, releases the
remote control and returns the
instrument to local panel
operation (page 106).
GDM-834X Series User Manual
18
Lower Measurement keys
REL
REL
REL#
Measures the Relative value (page
67).
REL#
(SHIFTREL)
SHIFT
EXIT
REL
REL#
Manually sets the reference
value for the Relative value
measurement.
MX/MN
MX/MN
MATH
Measures the Maximum or the
Minimum value (page 66).
MATH
(SHIFT
MX/MN)
SHIFT
EXIT
MX/MN
MATH
Enters the Math
measurement mode. The
supported math functions
include MX+B, REF% and
1/X. See page 72 for details.
HOLD
HOLD
COMP
Activates the Hold function (page
69).
COMP
(SHIFTHOLD)
SHIFT
EXIT
HOLD
COMP
Activates the compare
measurement function. See
page 70.
TRIG
TRIG
INT/EXT
Triggers sample acquisition
manually when the trigger is set to
external triggering. See page 32.
(Note: Not supported for
capacitance measurement)
INT/EXT
(SHIFTTRIG)
SHIFT
EXIT
TRIG
INT/EXT
Toggles the trigger source
as either internal or
external(manual trigger).
GETTING STARTED
19
MENU
MENU
USB STO
Enters the configuration menu for
System Settings, Measurement
Settings, Temperature
measurement settings, I/O
settings and USB storage settings.
See page 76 for the system menu.
USB STO
(SHIFTMENU)
SHIFT
EXIT
MENU
USB STO
Logs measurement data to
a USB drive. This function
is only available for the
GDM-8342. See page 84.
SHIFT/EXIT
SHIFT
EXIT
When used as a SHIFT key, it is
used to access the secondary
functions associated with the
measurement keys.
When used as an EXIT key, it will
exit out of menu systems.
AUTO/ENTER
Auto
Enter
When used as an AUTO key, it
will set the range of the selected
function to autorange.
When used as an ENTER key, it
will confirm the entered value or
menu item.
GDM-834X Series User Manual
20
Arrow Keys
RANGE
RANGE
The arrow keys are used to
navigate the menu system and edit
values.
The Up and Down arrow keys will
also manually set the range for the
voltage and current
measurements.
The Left and Right arrow keys will
also toggle the refresh rate
between the fast, medium and
slow rates.
Display Overview
Primary Display
Secondary Display
Function status icons
Secondary
measurement units
Primary measurement units
Primary measurement
function icons
Secondary
measurement
function icons
REARGPIBUSBLANRS232FILTRCLSTOCOMP2ND
dBmEXTSHIFTERRLIMITAUTOMATH4W2WDCAC
AVmm
HzWkM
WSFC
mdB
%
AVmm
HzWkM
WSFC
RMTMAXMINRELHOLDSMFAUTO4W2WDCAC
USBSTO nμF
MEMRATIO UNCAL
nμF
50000 Counts Dual Measurement Multimeter
GDM-8342
Primary
Measurement
Function Icons
Displays the primary measurement function.
Primary
Measurement
Units
Displays the units for the primary measurement
function.
Secondary
Display
Displays the results of the secondary
measurement.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159

GW Instek GDM-8300 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI