Trango Systems TrangoLINK APEX 18GHz User manual

Type
User manual
TrangoLINK APEX
18GHz
Point-to-Point Microwave
Wireless Ethernet Bridge
High-Capacity Backhaul Network
User Manual
September 2008
Revision 1.0
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Figures Page 1
Table of Contents
Figures................................................................................................... 5
Tables..................................................................................................... 7
Preface................................................................................................... 8
Emission Designators ...........................................................................................8
Warranty Information ............................................................................................8
Chapter 1 - Overview .......................................................................... 10
About this Chapter ..............................................................................................10
Introduction .........................................................................................................11
Contents .............................................................................................................11
Location of Serial Number .............................................................................12
Apex Unit Ports...................................................................................................13
Chapter 2 - Getting Started ................................................................ 14
About this Chapter ..............................................................................................14
Connections and Power......................................................................................15
Basic - Concepts.................................................................................................16
Opmode Concept ..........................................................................................16
Mean Square Error Concept..........................................................................17
Max Power Input............................................................................................17
ACM – Adaptive Code Modulation.................................................................18
ATPC & TargetRSSI......................................................................................19
ATPC Max Power & Step Size ......................................................................19
Port Mapping (802.1q) & Port Priority (802.1p)..............................................20
Class of Service (802.1p) ..............................................................................20
Management.......................................................................................................20
Browser Interface ..........................................................................................21
Command Line Interface ...............................................................................23
Changing Password ......................................................................................24
Chapter 3 - Configuration................................................................... 26
About this Chapter ..............................................................................................26
Basic Configuration Screens and Parameters ....................................................27
System Information........................................................................................27
Radio Configuration.......................................................................................28
System Configuration ....................................................................................28
IP Configuration and Model ...........................................................................31
System Version .............................................................................................31
Settings Page ................................................................................................32
Radio Configuration.......................................................................................32
IP Configuration.............................................................................................34
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Figures Page 2
System Configuration ....................................................................................34
Ethernet Configuration...................................................................................35
Statistics Page...............................................................................................35
System Status ...............................................................................................36
Link Status.....................................................................................................36
Ethernet Status..............................................................................................37
RF Status ......................................................................................................37
Password Web Page .....................................................................................38
Essentials to Establish a Wireless Link...............................................................39
Evaluate Link Quality ..........................................................................................39
Link Test........................................................................................................39
Chapter 4 - Deployment & Installation..............................................42
About this Chapter ..............................................................................................42
Installation...........................................................................................................43
Mounting Hardware .......................................................................................43
Waveguide Adapter installation .....................................................................44
SFP Installation .............................................................................................45
Direct DC power connection..........................................................................45
Polarization....................................................................................................46
1+1 Coupler Installation ......................................................................................47
Polarization of 1+1 Coupler ...........................................................................50
Grounding ...........................................................................................................51
Weather Proofing Cabling...................................................................................51
Antenna Alignment..............................................................................................54
Antenna Alignment Procedure.......................................................................54
Upgrading Firmware ...........................................................................................55
Upgrade Procedures .....................................................................................55
Chapter 5 - Management .................................................................... 59
About this Chapter ..............................................................................................59
Objects for Monitoring and Control ................................................................60
Chapter 6 - Troubleshooting.............................................................. 62
About this Chapter ..............................................................................................62
No LINK ..............................................................................................................63
High BER ............................................................................................................63
GigE Port ............................................................................................................64
Fiber Port (SFP)..................................................................................................64
Management.......................................................................................................65
Chapter 7 – Bench Testing................................................................. 67
About this Chapter ..............................................................................................67
Bench test setup .................................................................................................68
Appendix A - Command Set Summary............................................... 71
System Command Keying ..................................................................................71
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Figures Page 3
Key Functions................................................................................................71
Different Mode Levels .........................................................................................72
View Mode.....................................................................................................72
Config Mode ..................................................................................................73
Debug Mode..................................................................................................77
CLI Command Description..................................................................................78
acm .....................................................................................................................78
alignment_mode .................................................................................................80
atpc .....................................................................................................................80
atpc_max_power.................................................................................................81
atpc_step ............................................................................................................82
ber.......................................................................................................................82
bootimage ...........................................................................................................83
cos ......................................................................................................................84
config ..................................................................................................................85
date.....................................................................................................................86
debug..................................................................................................................87
default_opmode ..................................................................................................87
exit ......................................................................................................................88
failover ................................................................................................................88
freq......................................................................................................................89
help / ? .............................................................................................................90
httpd....................................................................................................................90
ibm ......................................................................................................................91
ipconfig ...............................................................................................................92
datapattern..........................................................................................................93
license.................................................................................................................93
linktest.................................................................................................................94
loglevel................................................................................................................95
loopback .............................................................................................................95
model ..................................................................................................................96
mse .....................................................................................................................96
opmode...............................................................................................................97
passwd................................................................................................................97
Port (ge1 = Copper / ge2 = Fiber)......................................................................98
power ..................................................................................................................99
reboot..................................................................................................................99
remark...............................................................................................................100
remove..............................................................................................................100
reset..................................................................................................................101
rssi ....................................................................................................................102
rssiled ...............................................................................................................102
save ..................................................................................................................103
smart_mode......................................................................................................103
show .................................................................................................................104
snmpd ...............................................................................................................104
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Figures Page 4
snmptrap...........................................................................................................105
speed ................................................................................................................105
status ................................................................................................................106
sysinfo...............................................................................................................107
sync ..................................................................................................................109
sync_state.........................................................................................................109
syslog................................................................................................................110
targetrssi ...........................................................................................................110
temp..................................................................................................................111
telnetd ...............................................................................................................111
tftpd...................................................................................................................112
threshold ...........................................................................................................112
trapip.................................................................................................................113
uptime ...............................................................................................................113
utype .................................................................................................................114
version ..............................................................................................................114
Appendix B - Specifications............................................................. 116
Data Sheet........................................................................................................116
Interface Specifications.....................................................................................118
T/I Curves .........................................................................................................119
80 MHz channel (46 Symbol Rate)..............................................................119
40 MHz channel (35.42 Symbol Rate).........................................................120
30 MHz channel (24.6 Symbol Rate)...........................................................121
20 MHz channel (17.42 Symbol Rate).........................................................122
10 MHz channel (8.32 Symbol Rate)...........................................................123
FCC Requirement of Frequency Spacing .........................................................124
10 MHz maximum authorized bandwidth channels: ....................................124
20 MHz maximum authorized bandwidth channels: ....................................126
40 MHz maximum authorized bandwidth channels: ....................................127
80 MHz maximum authorized bandwidth channels: ....................................127
Appendix C – Cable Pin outs...........................................................128
Industry Standard CAT-5 Pin-outs ....................................................................128
Apex Serial Cable Pin-out.................................................................................129
Appendix D – MIB.............................................................................. 130
Appendix E - Part Numbers.............................................................. 138
Glossary - Acronyms........................................................................139
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Figures Page 5
Figures
Figure 1: Components of a TrangoLINK APEX 18 System .....................................11
Figure 2: Side of Radio (Shows where MAC address can be found) ......................12
Figure 3: Apex unit ..................................................................................................13
Figure 4: Wiring Diagram ........................................................................................15
Figure 5: Power Connections .................................................................................15
Figure 6: HTTP Login .............................................................................................21
Figure 7: Web Browser Login.................................................................................21
Figure 8: Browser Interface ....................................................................................22
Figure 9: System Information Web Page................................................................27
Figure 10: Settings Web Page ...............................................................................32
Figure 11: Statistics Web Page ..............................................................................36
Figure 12: Password Web Page.............................................................................38
Figure 13: Apex Mounting Assembly......................................................................43
Figure 14: Waveguide Adapter Installation.............................................................44
Figure 15: SFP Module Installation ........................................................................45
Figure 16: Direct DC Power Connection ................................................................45
Figure 17: APEX Polarization (Left Side Mount) ....................................................46
Figure 18: APEX Polarization (Right Side Mount) ..................................................46
Figure 19: 1+1 Coupler ..........................................................................................47
Figure 20: 1+1 Coupler and Latches ......................................................................48
Figure 21: 1+1 Coupler Installed on Antenna .........................................................48
Figure 22: 1+1 Apex Mounting ...............................................................................49
Figure 23: Installing Twist Transition on1+1 Coupler .............................................50
Figure 24: H and V Transitions...............................................................................50
Figure 25: POE Ground Screw...............................................................................51
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Figures Page 6
Figure 26: Ethernet Cap Installation.......................................................................52
Figure 27: Complete Ethernet Cap Installation.......................................................52
Figure 28: Fiber Plate Installation...........................................................................53
Figure 29: Complete Fiber Plate Installation (conduit not pictured)........................53
Figure 30: Windows Start & Telnet.........................................................................55
Figure 31: Verify Firmware Upgrade ......................................................................58
Figure 32: Serial Number Location.........................................................................66
Figure 33: Bench Test Setup..................................................................................68
Figure 34: Waveguide Attenuator...........................................................................69
Figure 35: EIA/TIA 586 A & B Pin-Outs................................................................128
Figure 36: Apex Serial Cable Pin-Out ..................................................................129
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Tables Page 7
Tables
Table 1: TrangoLINK APEX 18 Part numbers ...........................................................8
Table 2: MSE Values ...............................................................................................17
Table 3: Max Power Input........................................................................................18
Table 4: ACM Threshold Table ................................................................................19
Table 5: Default Login Passwords ...........................................................................20
Table 6: Torque .......................................................................................................43
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Preface Page 8
Preface
This manual covers the basic configuration and installation of the TrangoLINK APEX 18
Wireless Broadband System, and applies to the following part numbers:
Part Number Description
TLINK-APEX18-1 TrangoLINK APEX™ point to point system, 18GHz, Rev 1
APEX18-ODU-1A TrangoLINK APEX™ Outdoor Unit, 18GHz, Band 1, ANSI
APEX18-ODU-1B TrangoLINK APEX™ Outdoor Unit, 18GHz, Band 2, ANSI
PSUPPLY-48 19” Rack mount -48v Power supply
PSUPPLY-DT-48 -48 Volt Universal Power Supply, Rev A
POE-APEX-48 POE injector for TrangoLINK-APEX™
CBLDAT-3 Serial Console Cable for Apex
APEX18-KEY-1 Software Key to Allow Throughputs up to 200Mbps
APEX18-KEY-2 Software Key to Allow Throughputs up to 370Mbps
Table 1: TrangoLINK APEX 18 Part numbers
Emission Designators
10M0D7W for 10 MHz BW rates and all modulations
20M0D7W for 20 MHz BW rates and all modulations
30M0D7W for 30 MHz BW rates and all modulations
40M0D7W for 40 MHz BW rates and all modulations
50M0D7W for 50 MHz BW rates and all modulations
56M0D7W for 56/80 MHz BW rates and all modulations
Warranty Information
TrangoLINK-APEX units purchased from Trango Broadband Wireless are warranted for
two years from date of purchase. Please see www.trangobroadband.com for a complete
description of warranty coverage and limitations. Extended warranty protection can be
purchased through Trango Sales or Customer Service (1-858-391-0010).
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Preface Page 9
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 1 - Overview Page 10
Chapter 1 - Overview
About this Chapter
This chapter introduces the TrangoLINK APEX™ system, features, and its components
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 1 - Overview Page 11
Introduction
The TrangoLINK APEX™ is a carrier grade high-performance all outdoor point-to-point
wireless microwave system designed for Enterprise, Carrier and WISP networks using
licensed 18 GHz spectrum. The TrangoLINK APEX™ provides a full duplex wireless
connection over the air that is ideal for copper RJ45 Ethernet connections as well as
fiber optics through the use of SFP ports.
The TrangoLINK APEX™ is a Frequency Division Duplex (FDD) radio which provides
low latency of less than 150μs, over 1 million packets per second, and up to 730+ Mbps
of data. The TrangoLINK APEX™ uses VLAN and QoS prioritization to offer great
flexibility in offering high value added services.
Contents
Each TrangoLINK APEX 18 kit comes equipped with (1) APEX18-ODU1A, (1) APEX18-
ODU-2A, and (2) wave guide transitions. POE devices, Fiber kits, Data cables, and
power cables are not included with your system.
Figure 1: Components of a TrangoLINK APEX 18 System
!
ADDITIONAL ACCESSORIES ARE REQUIRED FOR COMPLETE
INSTALLATION OF THE TRANGOLINK APEX™18 SUCH AS POWER
SUPPLIES, POE DEVICES, FIBER KITS, AND ANTENNAS.
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 1 - Overview Page 12
Location of Serial Number
Figure 2: Side of Radio (Shows where MAC address can be found)
Apex
Apex
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 1 - Overview Page 13
Apex Unit Ports
.
Figure 3: Apex unit
Fiber Kit cover: Under this cover is the MOLEX™ power connector and SFP fiber port.
Ethernet 10/100/1000: The RJ-45 connector allows for 10/100/1000 data negotiation
rates. POE can also be connected through this port.
Management Port: 10/100 Out of Band Management port allows for PoE as well as
management. No data pass through is allowed on this port.
RSSI Digital Display: RSSI value of the link is displayed on the digital display
Slip Mount Latches: Slip-mount installation secures the ODU to the Antenna Assembly
or mounting bracket and allows easy removal during maintenance.
Slip Mount Waveguide Transition: Connects the ODU transmit signal to the antenna
waveguide port.
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 2 - Getting Started Page 14
Chapter 2 - Getting Started
About this Chapter
This chapter discusses the basic steps to get started. The following topics will be
covered in this chapter:
Connection and Power
Basic Configuration Concepts
Management
It is recommended that you first provision and test the radios on the bench before
deploying them in the field. This is a particularly useful exercise for the novice user.
!
Additional accessories are required for complete installation of the TrangoLINK APEX 18
such as power supplies, SFP modules, and antennas.
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 2 - Getting Started Page 15
Connections and Power
Figure 4: Wiring Diagram
Connect Ethernet cable between the Apex unit and the POE unit. (Power over
Ethernet can be through either the data or management ports.) Alternately, there
is a 2 pin MOLEX™ connector under the fiber cover for direct -48 DC power.
Please note that when the pins are facing up, the + (Red/Ground) is on the left.
Figure 5: Power Connections
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 2 - Getting Started Page 16
Out of Band Management Connection - If connecting to a COMPUTER to the out
of band management port, use a Cross-Over Ethernet cable from the
management port of the IDU to the computer’s Ethernet port.
When connecting a HUB, SWITCH, or ROUTER, to the GigE ports use a
Straight-Thru cable.
The Apex unit requires power from a -48Volt power supply either directly or
through the POE power injector. Trango Broadband recommends the use of a
PSUPPLY-1U-48 or PSUPPLY-DT-48 and use of a ferrite suppressors supplied
with the power connector to reduce noise that may couple into the IDU on the
power line. Wrap both the + and – wires one time around the ferrite. See
appendix C for a complete listing of accessories.
You are now ready to configure the radio via the management Ethernet port.
!
If you cannot access the radio management functions via the management Ethernet port, it
is possible that your PC is not set up with a properly routable subnet. If cannot access the
radio via the management Ethernet port, use the Console Programming Cable and attach it
to the Console Port. The proprietary console cable needed for this can be purchased from
your sales manager. Settings and connection steps are found later in this chapter.
Basic - Concepts
The TrangoLINK APEX 18 can be configured using either the Command Line Interface
(CLI), or the Web Browser (HTTP) interface. Although both methods are comprehensive
and powerful, the CLI method provides more functionality. Both methods of radio
configuration require an understanding of the concept of Operation Mode (Opmode).
Opmode Concept
Before logging into a radio, it is important to understand the “Opmode” concept of the
TrangoLINK APEX 18. TrangoLINK APEX™18 can be in one of two operational modes:
Opmode “On” or Opmode “Off.” When in Opmode “Off” the radio is not transmitting,
and it is not attempting to make a wireless connection. Alternatively, when in Opmode
“On,” the radio is transmitting, and is attempting to make a wireless connection. The
radio can still be managed when Opmode is “Off”. The radio default is Opmode “Off” to
ensure that nothing is transmitted until the installation is complete and there is no risk of
unintentional RF radiation.
Default Opmode
Default Opmode setting controls whether opmode will be turned on after the boot
process has completed. If Default Opmode is “Off” and Opmode is “On” the radio will
not transmit upon rebooting. The default setting is Opmode “Off” to ensure that nothing
is transmitted until the installation is complete and there is no risk of unintentional RF
radiation.
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 2 - Getting Started Page 17
Why is Opmode Important?
Opmode is important since if Opmode is not configured correctly the radio will not
transmit to establish a link. There are also certain functions that can only be performed
while the radio is in Opmode “Off.” The following commands can only be performed
with Opmode “Off”
Setting / Changing Transmit Frequency
Enabling Loopback
!
FACTORY DEFAULT OPMODE IS “OFF.” DEFAULT OPMODE SHOULD BE CHANGED
BEFORE RADIOS ARE DEPLOYED. CONSOLE MANAGEMENT IS POSSIBLE
REGARDLESS OF OPMODE.
Mean Square Error Concept
Mean Square Error (MSE) is similar to Signal to Noise Ratio (SNR) except that is
accounts for distortion and interference in addition to noise power. Distortion may come
from several sources such as IF cables that are improperly constructed path
degradations such as multipath or Fresnel zone encroachment. Interference may not
only come from other transmitters on the tower, but also from high power transmitters in
the indoor shelter where the IDU is located or from transmitter located very close to the
cable. There are maximum acceptable MSE values for each modulation which are
useful in determining the quality of the link. The MSE value reported is only relevant to
one tx-rx path, so the MSE of each tx-rx path must be evaluated to verify the link is
operating cleanly. The lower the number the better so a -35dB is better than a -30dB.
The table below shows the maximum MSE value to expect in IF Loopback, Normal
Operation, and Absolute Maximum.
MSE Expected and Maximum values
QAM256 QAM128 QAM64 QAM32 QAM16 QPSK
Maximum Expected
value IF loopback -36 -36 -36 -36 -36 -36
Maximum Expected
value Normal
operation -32 -32 -32 -32 -32 -32
Absolute Maximum
for 1E-6 BER -28 -25 -22 -19 -16 -9
Table 2: MSE Values
Max Power Input
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 2 - Getting Started Page 18
The maximum power input, measured by RSSI, is as depicted in Table 3. If your RSSI value is
higher than listed for the modulation that you are running, you may incur bit error rates as well
as possible damage to the system.
256 QAM: -34 dBm
128 QAM: -32 dBm
64QAM: -30 dBm
32QAM: -28 dBm
16QAM: -26 dBm
QPSK: -24 dBm
Table 3: Max Power Input
ACM – Adaptive Code Modulation
The ACM feature of the TrangoLINK APEX™ works in conjunction with the MSE of the
unit. The ACM command is an on/off command. Once ACM is enabled and link is
degraded to the MSE threshold specified, the radio will shift down in modulation and
speed based on the setting of the ACM table (Table 4).
Profile # Modulation Improve Next Degrade Next
Speed Setting QAM256
Profile # Modulation Improve Next Degrade Next
0 QAM256 -32.1 0 -27.2 1
1 QAM64 -29.2 0 -24.3 2
2 QAM16 -26.3 1 -21.3 3
3 QPSK -23.3 2 -18.5 3
Speed Setting QAM128
Profile # Modulation
Improve
Next
Degrade
Next
0 QAM128 -32.1 0 -27.2 1
1 QAM64 -29.2 0 -24.3 2
2 QAM32 -26.3 1 - 21.3 3
3 QAM16 -23.3 2 -18.5 4
4 QPSK -20.3 3 17.1 4
Speed Setting QAM64
Profile # Modulation
Improve
Next
Degrade
Next
0 QAM64 -29.2 0 -24.3 1
1 QAM32 -26.3 0 - 21.3 2
2 QAM16 -23.3 1 -18.5 3
3 QPSK -20.3 2 17.1 3
Speed Setting QAM32
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142