Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeand
satisfactoryoperationofthisproduct.Pleaseretaintheseinstructionsforfuturereference.
Warning
This is a Class 1 product and must be earthed.
Pleasereadtheseinstructionscarefullybefore
commencinganywork.
Thisunitmustbefittedbyacompetentandqualified
electrician.
InstallinaccordancewithIEEWiringregulationsand
currentBuildingRegulations.
Topreventelectrocutionswitchoffatmainssupply
beforeinstallingormaintainingthisfitting.Ensure
otherpersonscannotrestoretheelectricalsupply
withoutyourknowledge.Ifyouareinanydoubt,
pleaseconsultaqualifiedelectrician.
Thislightfittingshouldbeconnectedtoafusedcircuit.
Ifreplacinganexistingfitting,makeacarefulnoteof
theconnections.
Thissystemcontainsnon-replaceablepartsand
cannotbeserviced.Ifdamageoccursthepartshould
bescrapped.
Wasteelectricalproductsshouldnotbedisposedof
withhouseholdwaste.Pleaserecyclewherefacilities
exist.Checkwithyourlocalauthorityorretailerfor
recyclingadvice.
Thisproductisnotsuitablefordimming.
Specification
Voltage: 240V50Hza.c.
Lamp: 7WLEDModule(COB)NaturalWhite-629lm
IPrating: 20
Layout
Existingfittingsmustbecompletelyremovedbefore
installationofanewproduct.Beforeremovingthe
existingfitting,carefully note the position of each set
of wires.
• Usingtheceilingcoverasatemplate,markthefirst
holepositionandfitthescrewinpositionasshown
below.Ensuretheceilingiscapableofholdingthe
weightofthetrackandproducts.Takecaretoavoid
damaginganyconcealedwiringandpipes.The
correctfixingsshouldbeusedforbrick,cavitywalls
orplasterboard.
• Feedthescrewthroughthekeyholeslot,andslide
intoposition.Markthepositionofthesecondhole.
Locatethetrackandfitthesecondscrewinto
position.
• Wireasdetailedbelow.
Installation
Wiring
Check that...
• Youhavecorrectlyidentifiedthewires.
• Theconnectionsaretight.
• Noloosestrandshavebeenleftoutoftheconnection
block.
• Planthedesiredlayoutofthisfittingcarefully,
ensuringthecableswillreachthedistancebetween
thejunctionboxandthelightfitting.
• Avoidlocatinganycablesinpositionsthatwould
causeahazard.Positioncablesandjunctionboxes
(notsupplied)awayfromareaswheretheymaybe
atriskfrombeingcut,trappedordamaged.
• Themainssupplycablemusthaveaminimumcross
sectionalareaof1.0mm².
Havingidentifiedthehouseholdwiringfromyourexistinglightfitting,connecttotheconnectionblockinsidetheproduct
inthefollowingway:
• Undothescrewandremovethecoverfromtheliveend.
• Pushoutthedesiredcableaccesspoint.
• Identifythecorrectcablefromthesupplyandpullthrough.
• Connectthesupplywirestotheterminalblock,oppositethe
• correspondingwiresfromthefitting.Thecentralconnector
• canalsobewiredinthisway.
• Refitthecoverontotheliveendtakingcarenottotrapthecable.
N
L
N
L
Supply
Fitting an additional track
• Theseproductsaresuppliedwithastraightconnector
thatenablesthefittingofanadditionaltrack.Theconnector
hasearthconnectionpointsonbothsides
• Verifywhichtabneedstoberemovedwhenofferingthe
• connectorto thetrack.Toremove the tab,grasp firmly
with a pair of pliers and lever back. The tab should snap
cleanly.
• Locatetheconnectorinthetrackandpushhome. Remove One
or Other Tab
Marked in Grey
End view of track
Earth
Conductor
Remaining Earth tab needs to
be inserted into Earth conductor
to ensure Earth continuity.
Spotlightsgiveaconcentratedbeamoflightandmustnotbepositionedanycloserthan0.5M
(50cm)totheilluminatedsurface.