Verona VEFSGE304PSS Installation guide

Category
Cookers
Type
Installation guide
GAS/ELECTRIC RANGE
for residential use only
THIS RANGE IS FOR RESIDENTIAL USE ONLY
FOR INSTALLER ONLY
Some models are supplied with a protective lm on steel and aluminium
parts. This lm must be removed before installing/using the appliance.
Models: VEFSGE304P..
INSTALLATION INSTRUCTIONS
IMPORTANT - PLEASE READ AND FOLLOW
• Beforebeginning,pleasereadtheseinstructionscompletelyandcarefully.
• Donotremovepermanentlyafxedlabels,warnings,orplatesfromtheproduct.Thismay
voidthewarranty.
• Pleaseobservealllocalandnationalcodesandordinances.
• Pleaseensurethatthisproductisproperlygrounded.
The installer should leave these instructions with the consumer who should retain
for local inspectors use and for future reference.
Installationmustconformwithlocalcodesorintheabsenceofcodes,theNationalFuelGas
CodeANSIZ223.1-Iatestedition.ElectricalinstallationmustbeinaccordancewiththeNa-
tionalElectricalCode,ANSI/NFPA70-latesteditionand/orlocalcodes.
INCANADA:InstallationmustbeinaccordancewiththecurrentCAN/CGA-B149.1National
GasInstallationCodeorCAN/CGA-B149.2,PropaneInstallationCodeand/orlocalcodes.
ElectricalinstallationmustbeinaccordancewiththecurrentCSAC22.1CanadianElectrical
CodesPart1and/orlocalcodes.
INSTALLATIONINMANUFACTURED(MOBILE)HOME:Theinstallationmustconformwith
theManufacturedHomeConstructionandSafetyStandard,Title24CFR,Part3280[formerly
theFederalStandardforMobileHomeConstructionandSafety,Title24,HUD(Part280)]
or,whensuchstandardisnotapplicable,theStandardforManufacturedHomeInstallations,
ANSI/NCSBCSA225.1,orwithlocalcodeswhereapplicable.
INSTALLATIONINRECREATIONALPARKTRAILERS:Theinstallationmustconformwith
stateorothercodesor,intheabsenceofsuchcodes,withtheStandardforRecreational
ParkTrailers,ANSIA119.5.
Installation of any gas-red equipment should be made by a licensed plumber.A manual
shut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternaltotheap-
plianceforthepurposeofturningonorshuttingoffgastotheappliance(InMassachusetts
suchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminersofPlumbers&
GasFitters).
Ifanexternalelectricalsourceisutilized,theappliance,wheninstalled,mustbeelectrically
groundedinaccordancewithlocalcodesor,intheabsenceoflocalcodes,withthenational
ElectricalCode,ANSI/NFPA70.
R
2
WARNING !
To reduce the risk of tipping the appliance,
the appliance must be secured by properly
installed anti-tip device packed with the
appliance.
ALL RANGES CAN TIP
INJURY TO PERSONS COULD RESULT
INSTALL ANTI-TIP DEVICE PACKED
WITH RANGE
SEE INSTALLATION INSTRUCTIONS
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
NEVER use this appliance as a space heater to heat or warm
the room. Doing so may result in carbon monoxide poiso-
ning and overheating of the appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• lmmediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
• lf you cannot reach your gas supplier, call the re depart-
ment.
Installation and service must be performed by a qualied
installer, service agency, or the gas supplier.
If the information in this manual is not followed exactly,
a re or explosion may result causing property damage,
personal injury, or death.
WARNING !
3
Thisapplianceisdesignedandmanufacturedsolelyforthecookingofdomestic(household)food
andinnotsuitableforanynonedomesticapplicationandthereforeshouldnotbeusedinacom-
mercialenvironmement.
Theappliancewarrantywillbevoidiftheapplianceisusedwithinanonedomesticenvironmement
i.e.asemicommercial,commercialorcommunalenvironment.
CONVERSIONLABEL
DATAPLATE
4
INSTALLATION INSTRUCTIONS
WARNING!
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.
Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a quali-
ed installer, service agent, or the gas supplier.
Screwdriver 2 - Wrench
T-handle
wrench
Tape
measurePencil
Adjustable
pliers
Adjustable
wrench
Suitable protective
gloves
Drill
Hammer
TOOLS NEEDED FOR INSTALLATION (NOT SUPPLIED WITH THE APPLIANCE)
IMPORTANT: The use of suitable protective clothing/gloves is
recommended when handling, installing of this appliance.
5
GENERAL INFORMATION
1. Installationmustconformwithlocalcodesor,intheabsenceof
localcodes,withtheNational Fuel Gas Code,ANSIZ223.1-
LatestEdition,CAN/CGA-B149.1orCAN/CGA-B149.2.
2. Installationinmanufactured(mobile)home:installationmust
conform with the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 [formerly the Fe-
deral Standard for Mobile Home Construction and Safety,
Title 24, HUD (Part 280)]or,whensuchstandardisnotappli-
cable,the StandardforManufactured Home Installations,
ANSI/NCSBCS A225.1, or with local codes where applica-
ble.
3. Installation in Recreational Park Trailers: installation must
conformwithstateorothercodesor,intheabsenceofsuch
codes, with the Standard for Recreational Park Trailers,
ANSI A119.5.
4.
WARNING!!
This appliance shall not be used for space heating. This
information is based on safety considerations.
5. AlIopeningsinthewallbehindtheapplianceandintheoor
undertheapplianceshallbesealed.
6. Keepapplianceareaclearandfreefromcombustiblemate-
rials,gasoline,andotherammablevapors.
7. Donotobstructtheowofcombustionandventilationair.
8. Disconnecttheelectricalsupplytotheappliancebeforeser-
vicing.
9. Whenremovingapplianceforcleaningand/orservice;
A. Shutoffgasatmainsupply.
B. DisconnectACpowersupply.
C. Disconnectgaslinetotheinletpipe.
D. Carefullyremovetherangebypullingoutward.
CAUTION:Rangeisheavy;usecareinhandling.
10.
Electrical Requirement
Electrical installation should comply with national and local
codes.
11.
Air Supply and Ventilation
Theinstallermustreferstolocal/nationalcodes.
12.
Gas Manifold Pressure
Naturalgas-4.0”W.C.P.
LP/Propane-11.0”W.C.P.
13. Themisuseofovendoor(e.g.stepping,sitting,orleaningon
them)canresultinpotentialhazardsand/orinjuries.
14. Wheninstallingorremovingtherangeforservice,arollinglift
jackshouldbeused.Donotpushagainstanyoftheedgesof
therangeinanattempttoslideitintooroutoftheinstallation.
Pushingorpullingarange(ratherthanusingaliftjack)also
increases the possibility of bending the leg spindles or the
internalcouplingconnectors.
WARNING!!
ELECTRICAL GROUNDING INSTRUCTIONS
The range must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the Natio-
nal Electrical Code, ANSI/NFPA No. 70-latest edition, in Cana-
da Canadian Electrical Code.
Installation should be made by a Iicensed electrician.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PRO-
PERLY GROUNDED.
Ifanexternalelectricalsourceisutilized,theinstallationmustbe
electrically grounded in accordance with local codes or, in the
absenceof local codes,withthenationalElectrical Code,ANSI/
NFPA70.
REPLACEMENT PARTS
Onlyauthorizedreplacementpartsmaybeusedinperformingser-
viceontherange.Replacementpartsare availablefromfactory
authorizedpartsdistributors.Contactthenearestpartsdistributor
inyourarea.
6
PROXIMITY TO SIDE CABINETS
1. Thisrangemaybeinstalleddirectlyadjacenttoexisting36”(914mm)
highbasecabinets.
Rangedimensions:
• width:29”7/8(759mm)
• depth:24”13/64(614.9mm)
• height (without backguard): MIN 35” 21/32 (905.5 mm) - MAX 36”
11/32(923mm)
• backguard(height):3”(76mm)
Gas line opening: Wall-37/64”(14.5mm)fromtherightsidetocentre
ofrange;from5”7/16(138mm)to6”1/8(155.5mm)[dependingonfeet
regulation]fromtheoor.
Grounded outlet:shouldbelocated37/64”(14.5mm)fromtheleftside
tocentreofrange;from5”7/16(138mm)to6”1/8(155.5mm)[depen-
dingonfeetregulation]fromtheoor.
2. TherangeCANNOTbeinstalleddirectlyadjacenttosidewalls,tallcabi-
nets,tallappliances,orothersideverticalsurfacesabove36”(914mm)
high.
Theremustbeaminimumof11”13/16(300mm)sideclearancefromthe
rangetosuchcombustiblesurfacesTOTHELEFTorTOTHERIGHT
abovethe36”(914mm)highcountertop.
IMPORTANT: One side (left or right) above the 36” (914 mm) high
countertop must always be kept clear.
Island installation: Theremustbeaminimumof12”(305mm)clearan-
cefrom therearofthe backguardtosuchcombustible surfaceonthe
backoftherangeabovethe36”(914mm)highcountertop.
3. Themaximumuppercabinetdepthrecommendedis13”(330mm).Wall
cabinetabovetherangemustbeaminimumof30”(762mm)abovethe
countertopforawidthofminimum30”(762mm):ithastobecentered
withtherange.Sidewallcabinetsabovetherangemustbeaminimum
of18”(457mm)abovethecountertop.
installation
1
Fig. 1.1
3”
(76mm)
MIN35”21/32(905.5mm)
MAX36”11/32(923mm)
24”13/64
(614.9mm)
29”7/8
(759mm)
7
A
A
B
ASSEMBLING THE BACKGUARD
It is mandatory to install the backguard.
Assemblethebackguardasshowningure1.3:
• Screwthe2screws“A”interposingthespacers.
• Screwthecentralscrew“B”.
1
Fig. 1.3
GAS AND ELECTRIC CONNECTION
Fig. 1.2
Dottedlineshowingtheposition
oftherangewheninstalled
Areafor
ELECTRICAL
connection
Areafor
GASconnection
B
A
B
C
C
Ref. inch mm
A 5”7/16-6”1/8 138-155.5
B 14”3/8 365
C 37/64” 14.5
(*):Dependingonfeetregulation
8
B
G
E
D
C
F
A
A
B
C
E
D
F
G
A
A
PROXIMITY TO SIDE CABINETS
STANDARD INSTALLATION
Fig. 1.4b
Fig. 1.4a
OVEN VENT
Ref. inch mm
A 0” 0
B 36” 914
C 11”13/16 300
D 30”minimum 762minimum
E 18”minimum 457minimum
F 13”maximum 330maximum
G 20”minimum 500minimum
OVEN VENT
1
9
PROXIMITY TO SIDE CABINETS
ISLAND INSTALLATION
A
A
B
G
E
D
F
C
H
A
A
B
G
E
D
F
C
H
Fig. 1.5b
Fig. 1.5a
OVEN VENT
Ref. inch mm
A 0” 0
B 36” 914
C 11”13/16 300
D 30”minimum 762minimum
E 18”minimum 457minimum
F 13”maximum 330maximum
G 20”minimum 500minimum
H 12”minimum 305minimum
OVEN VENT
1
10
1
YOU MUST USE STABILITY
ANTI TIP BRACKET TO
PREVENT UNIT FROM
TIPPING.
ANTI-TIP STABILITY DEVICE INSTALLATION INSTRUCTIONS
1. Theanti-tipbrackethastobeattachedasshownongurebelow(onlyrearleftside),
ithastobexedontheoorandontherearwallbyno.6(six)suitablescrews(not
supplied).
2. Afterxingtheanti-tipbracket,sliderangeintoplace.Besuretherearleftfootslides
undertheanti-tipbracketattached.
LEVELLING THE RANGE
Therangeisequippedwith4LEVELLINGFEETandmaybelevelledbyscrewingor
unscrewingthefeet(gs.1.6-1.7).
Itisimportanttoobservethedirectionsofgures1.6,1.8a,1.8b.
Fig. 1.8bFig. 1.8a
Fig. 1.7
Fig. 1.6
Suppliedwiththerange
inaseparatekit
Suppliedwiththerange
inaseparatekit
0”
0mm
+5/16”
+8mm
+5/16”
+8mm
+11/16”
+17.5mm
Fig. 1.9
Dotted line showing the position
oftherangewheninstalled
ANTI-TIPSTABILITY
DEVICEFIXING
Anti-tipstability
device
Rearleft
feetofrange
3”15/64
(82mm)
11
1
INSTALLING THE COOKTOP FRONT GUARD
Toincreasetheclearancebetweenthefrontedgeofthecooktopandtheburnersitispossibletoinstallthecooktopfrontguardsupplied
withtheappliance.
IMPORTANT: To install/remove the guard it is necessary to remove the cooktop.
Attempting to install/remove the guard without disassembling the cooktop will result in permanent damage to the appliance.
Installthefrontguardasshowningure1.10:
1. Removethebackguard.
2. Removethepansupportsandtheburneramespreaders.
3. Unscrewcooktopxingscrews(“A”ingurebelow).
4. Removethedualburnerinneramespreader(“B”ingurebelow).
5. Removethecooktop(keepattentionnottodamagethegasketsttedabovetheburnercups-belowthecooktop).
6. Installthefrontguard“C”byinsertingthewireterminalsintotheproperholesabovethecontrolpanel(“D”ingurebelow).
7. Reassemblethecooktopandtheothercomponents(stepsfrom5to1).
Payspecialattentiontothegasketsttedabovetheburnercups
(belowthecooktop);iftheyaredamagedtheyshallbereplaced.
Fig. 1.10
A
A
A
A
A
A
B
B
C
D
D
12
gas connection
2
2. Pressure Regulator:
a. Allheavyduty,commercialtypecookingequipmentmusthaveapressureregulator
ontheincomingservicelineforsafeandefcientoperation,sinceservicepressure
mayuctuatewithlocaldemand.
Beforeinstallingtheregulatormountthe1/2”NPT(conical)maleconnectortothe
regulator(seepicture2.2).
Gasketsuppliedhastobeplacedbetween1/2”NPT(conical)connector/extension
pipemalepipetting(seepicture2.3).
Theregulatorsuppliedwiththisrangemustbeinstalledbeforeanygasconnections
aremade.
Usesuppliedpressureregulatoronly.
Gas supply line
Shuto valve
“open” position
To range
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.
Examples of a qualified person
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
Fig. 2.1
Allgasconnectionsmustbemadeaccordingtonationalandlocalcodes.Thisgassupply
(service)linemustbethesamesizeorgreaterthantheinletlineoftheappliance.Sea-
lantonallpipejointsmustberesistanttotheactionofLP/Propanegas.
TherangeisequippedfortheusewithNATURALgas.Itisdesign-certiedbyCSAInter-
nationalforNATURALandL.P.gaseswithappropriateconversion.
Themodel/serialratingplate,locatedonthebackoftheappliance,hasinformationon
thetypeofgasthatcanbeused.Ifthisinformationdoesnotagreewiththetypeofgas
available,checkwiththelocalgassupplier.Seepagefrom16to19forL.P.gasconver-
sioninstructions.
1. Manual Shut-off Valve(g:2.1):
Amanualshut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternal
totheapplianceforthepurposeofturningonorshuttingoffgastotheappliance(InMas-
sachusettssuchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminersof
Plumbers&GasFitters).
Thisvalveshouldbelocatedinthesameroomastherangeandshouldbeinalocation
thatallowseaseofopeningandclosing(inapositionwhereitcanbereachedquicklyin
theeventofanemergency).
Donotblockaccesstotheshutoffvalve.Thevalveisforturningonorshuttingoffgas
totheappliance.
13
2
LOCK
Arrow
PRESSURE REGULATOR INSTALLATION
STEP 1
Mountthe1/2”NPT(conical)maleconnectortothepressureregulatorand
tightenbyusingawrench.
Donotovertightentheconnector.
Overtighteningmaycrackregulator.
STEP 2
Assemblethe1/2”NPTconnector+pressureregulatorgrouptotheextensionpipeinterposingthegasketsupplied.
Theregulatorcovermustbeorientedtowardthefrontsideoftherange.
IMPORTANT:usetwowrenchestotightentheconnection.
Fig. 2.3
Fig. 2.2
Regulatorcover
Gasket
14
2
Fig. 2.4
GAS CONNECTION SPEFICICATION
Range
manifold
Manifold male pipe tting
1/2”Gcylindrical
(ISO228-1)male
1/2”Gcylindrical
(ISO228-1)female
Gasket
Extension
pipe female
pipe tting
Torange
1/2”Gcylindrical
(ISO228-1)female
Extension
pipe
1/2”Gcylindrical
(ISO228-1)male
Extension
pipe male
pipe tting
Gasket
Connector
1/2”NPT(conical)
male
1/2”NPT
female
Pressure
regulator
1/2”NPT
female
Tomains
connection
Arrow
WARNING: check the right positioning of the gas
regulator.
The arrow on the back of the gas regulator must be
oriented toward the connector.
15
2
b. Anyconversionrequiredmustbeperformedbyyourdealeroraqualiedlicen-
sedtechnicianorgasservicecompany.Pleaseprovidetheservicepersonwith
thismanualbeforeworkisstartedontherange.(Gasconversionsarethere-
sponsibilityofthedealerorenduser.)
c. ThisrangecanbeusedwithNATURALorLP/PROPANEgas.Itisshippedfrom
thefactoryadjustedforusewithNATURALgas.
d. Manifold pressure should be checked with a manometer and by operating as
belowdetailed:
• Removetheinjectorfromtherearleft(orrearright)burnerandmountthe
proper test point adapter which is available from the After-Sales Service
(seesidegureandthe“OPERATIONSTOBEPERFORMEDWHENSUB-
STITUTINGTHEINJECTORS”chapter).
• Turntherearleft(orrearright)burnercontrolknobtothemaximumposi-
tion.
• Presstheknobandkeepingitpressedcheckthemanifoldpressurewitha
manometer;NATURALgasrequires4.0”W.C.P.andLP/PROPANErequires
11.0”W.C.P.
• Incominglinepressureupstreamfromtheregulatormustbe1”W.C.P.hi-
gherthanthemanifoldpressureinordertochecktheregulator.
• Theregulatorusedonthisrangecanwithstandamaximuminputpressure
of1/2PSI(14.0”W.C.P).Ifthelinepressureisinexcessofthatamount,a
stepdownregulatorwillberequired.
e. Theappliance,itsindividualshut-offvalve,andpressureregulatormustbedi-
sconnectedfromthegassupplypiping system during any pressure testing of
thatsystematpressuresinexcessof1/2PSI(3.5kPa).
f. Theappliancemustbeisolatedfromthegassupplypipingsystembyclosingits
individualmanual shut-offvalveduringany pressuretestingof thegassupply
pipingsystemattestpressureequaltoorlessthan1/2PSI(3.5kPa).
3. Flexible Connections:
Iflocalcodespermit,CSAorULdesign-certied,exiblemetalapplianceconnector
isrecommendedforconnectingthisrangetothegassupplyline.DoNotkinkorda-
magetheexibleconnectorwhenmovingtherange.Thepressureregulatorhas1/2”
NPTfemalepipethreads.Youwillneedtodeterminethettingsrequired,depending
onthesizeofyourgassupplyline,exiblemetalconnectorandshutoffvalve.
4. Rigid Pipe Connections:
Ifrigidpipeisusedasagassupplyline,acombinationofpipettingsmustbeusedto
obtainanin-lineconnectiontotherange.Allstrainsmustberemovedfromthesupply
andfuellinessorangewillbelevelandinline.
• Usejointcompoundsandgasketsthatareresistanttoactionofnaturalorpropa-
negasonallmalepipethreads.
• Donotovertightengasttingwhenattachingtopressureregulator.Overtighte-
ningmaycrackregulator.
5. Leak Testing:
IMPORTANT:Leaktestingoftheapplianceshallbeconductedasfollows:
• Afternalgasconnectionismade,turnonmanualgasvalveandtestallcon-
nectionsingassupply piping and appliance for gas leaks withasoapywater
solution.Duringthistestallappliancegasvalveshavetobeclosed.
• Inordertoavoidpropertydamageorseriouspersonalinjury,neveruseaIighted
match.Ifaleakispresent,tightenjointorunscrew,applymorejointcompound,
tightenagainandretestconnectionforleak.
Fig. 2.5
TESTPOINTADAPTER
The Test Point adapter is available from the
After-SalesService.
16
2
2
2
3
CONVERSION TO LP/PROPANE GAS
Everyrangeisprovidedwithasetofinjectorsforthevarioustypesofgas.
Selecttheinjectorstobereplacedaccordingtothe“INJECTORSTABLE”.
Thenozzlediameters,expressedinhundredthsofamillimetre,aremarkedonthebodyofeachinjector.
SETTING THE PRESSURE REGULATOR(g.2.6)
Thepressureregulatorisaccessiblebyremovingthewarmerdrawer;thepressureregulatorispositioned
ontherearrightsideoftherange(g.2.9).
Toremovethewarmingdrawer:
1. Openthedrawercompletely(g.2.6)
2. Movedowntheleverofleftguide(g.2.7)anduptheleverofrightguide(g.2.8).
3. Removethedrawer;thelevershavetobekeepmoved(g.2.6).
Fig. 2.7
Fig. 2.6
Fig. 2.8
17
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
REGULATOR COVER
Pressure
regulator
2
To set the pressure regulator(g.2.9):
1. Unscrewtheregulatorcover.
2. UnscrewtheA” component, reverseandscrewitaccor-
dingtotheLP/PROPANEregulation.
Fitting the warming drawer (g.2.10):
1. Insertthedrawerguidesintotherangeguides(g.2.10).
2. Gentlyclosethedrawercompletely;thesafetycatchswillbeautomaticallyhooked.
Fig. 2.10
Fig. 2.9
18
2
OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE
INJECTORS
• Removethepansupports,theburnercapsandtheamespreaders.
• Dualburneronly(g.2.12):Unscrewtheno.3xingscrews“A”andremovetheinner
crownamespreaderB”;thenunscrewtheno.2xingscrewsC”andremovethe
coverplate“D”.
• UsingawrenchsubstitutethenozzleinjectorsJ
1
”,J
2
”andJ
3
”(gs.2.11,2.12)with
thosemostsuitableforthekindofgasforwhichitistobeused.
• Dualburneronly(g.2.12):
Ret
thecoverplateD”andscrewtheno.2xingscrews
C”;thenrettheinnercrownamespreaderB”andscrewtheno.3xingscrews
A
• Rettheamespreaders,theburnercapsandthepansupports.
The burner are conceived in such a way so as not to require the regulation of the
primary air.
SECOND ORIFICE
DEUXIEME ORIFICE
A
A
A
B
C
C
D
J
2
J
3
Fig. 2.12
J
1
Fig. 2.11
SEMI-RAPID BURNER
DUAL BURNER
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11”W.C.P.
NATURAL GAS
4”W.C.P.
BURNERS BTU/hr BTU/hr
Øinjector
[1/100mm]
Øinjector
[1/100mm]
Semirapid(SR) 8000 1500 85 139
Dual(D)
Innercrown 2100 1000
42(*)
115(#)
70(*)
200(#)
Inner&outercrown 17000 6500
(*) innercrown(“J
2
”ingure2.12)
(#) outercrown(“J
3
”ingure2.12)
19
Fig. 2.13
R
1
Regulationscrew(Semirapidburner)
R
2
Regulationscrew(Innercrownofdualburner)
R
3
Regulationscrew(Outercrownofdualburner)
R
1
R
3
R
2
SETTING THE BURNER MINIMUM
Whenswitchingfromonetypeofgastoanother,theminimumowratemustalsobecor-
rect:theameshouldnotgooutevenwhenpassingsuddenlyfrommaximumtominimum
ame.
Toregulatetheame(g.2.13)followtheinstructionsbelow:
Semirapid burner
• Lighttheburner.
• Setthegasvalveto“
LO”position(minimumrate).
• Removetheknob.
• Withathinscrewdriver,turntheregulationscrew“R
1
”untiladjustmentiscorrect.
Inside crown of DUAL burner
• LighttheDUALburner.
• Setthegasvalveto“
”position(minimumrateofinnercrown).
• Removetheknob
• Withathinscrewdriver,turntheregulationscrew“R
2
”untiladjustmentiscorrect.
Outside crown of DUAL burner
• LighttheDUALburner.
• Setthegasvalveto“
”position(minimumrateofinnerandoutercrowns).
• Removetheknob.
• Withathinscrewdriver,turntheregulationscrew“R
3
”untiladjustmentiscorrect.
For LP/PROPANE gas, tighten the adjustment screws completely.
Afterregulationrepeattheoperationsindicatedinparagraph“2.PRESSUREREGULA-
TOR”atpage12.
Iftherangehasbeendisconnectedandthenconnectedagaintothegassupplylinerepe-
attheoperationsindicatedinparagraph“5.LEAKTESTING”atpage15.
IMPORTANT:
AfterconversiontoLP/PROPANEgashasbeencarriedoutafxonthebackoftheap-
pliance, near the data plate, the conversion label supplied and also afx a conversion
labelatpage3ofthisinstructionmanual.
2
20
electrical connection
3
WARNING
TO AVOID ELECTRICAL SHOCK HA-
ZARD, BEFORE INSTALLING THE
APPLIANCE, SWITCH POWER OFF
AT THE SERVICE PANEL AND LOCK
THE PANEL TO PREVENT THE PO-
WER FROM BEING SWITCHED ON
ACCIDENTALLY.
ELECTRICAL REQUIREMENTS
• Thisappliancemustbeproperlyinstalledandgroundedbyaqualiedtechnicianin
accordancewiththeNationalElectricalCodeANSI/NFPANo.70(latestedition)and
localelectricalcoderequirements.
• Thisappliancemaybeconnectedbymeansofpermanent“HardWiring”or“Power
SupplyCordkit”.
• Powersupplycordisnotsupplied,butitisavailablethroughyourlocalelectricsup-
plyhouse.
• Useonly3-conductoror4-conductorCSA/ULlistedrangecordratedat30ampswith
250Vminimumandprovidedwithringterminals.Thesecordsshouldbeprovided
withstrainrelieforconduitconnector.
Warning: Framegroundedthroughneutrallead.Ifusedin,
Newbranch-circuitinstallations(1996NEC),
Mobilehomes,
Recreationalvehicles,or
Inanareawherelocalcodesprohibitgroundingthroughneutral,usea4con-
ductorcordorconduit.
• The range must be connected to the proper electrical voltage and frequency as
speciedontheratingplate.
• Therangecanbeconnecteddirectlytothefuseddisconnect(orcircuitbreakerbox)
throughexible,counduitwithcopperoraluminiumwiring(withgroundingwire).
Allowtwotothreefeetofslackinthelinesothatitcanbemovedifservicingisever
necessary.
ELECTRICAL CONNECTION WITH POWER CORD
Usea3-wirepowersupplycordkitratedfor30amps-240-208/120voltswithclosedloop
terminalsandmarkedforusewithranges.
Wherelocalcodesdonotpermitgroundingthroughneutral,usea4-wirepowersupply
cord.
TheCSA/ULlistedcordmustbesecuredtotherangewithasuitablestrainreliefbra-
cket.
Theelectricalconnectionismadeattheterminalblock,whichislocatedbehindtheac-
cessdooronthebackoftherange.
ELECTRICAL CONNECTION WITH CONDUIT
Use1/2”(1.3cm)tradesizeCSA/ULlistedconduitwithaconduitclamp,16AWG/600
voltcopperconductorcolored redforline1andblackforline2and16AWG/600volt
copperconductor(or14AWG/600voltcopperconductorifgroundingthroughneutral)
coloredwhiteforneutralwithclosedloopterminalsmarkedforusewithranges.
Wherelocalcodesdonotpermitgroundingthroughneutral,useagreen14AWGcopper
conductorasdirectedinthe4-wireconnectordirections.
Theconduitmustbesecuredtotherangewiththestrainreliefbracket.
Theelectricalconnectionismadeattheterminalblock,whichislocatedbehindtheac-
cessdooronthebackoftherange.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24