Miele 52830366USA Installation Plan

Type
Installation Plan
Installation Plan
Tumble dryer
PT 8303 SL EL (Electrically Heated)
en US
16.15
M.-Nr. 10 007 270 / 02
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
2
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone:
Fax:
www.mieleusa.com
Technical Service & Support
Nationwide
Phone:
800-991-9380
Fax:
800-220-1348
800-991-9380
609-419-4241
28
27 7/8 3/4
3/4
70 7/8
31 7/8
20 1/2
70 7/8
2 1/2
1
42 7/8
39 3/8
39 1/2
25 5/8
59
3/4
29 3/4
24 3/4
PT 8303 SL EL - measurements in inches
3
42 7/8
39 3/8
59
27 7/8
28
2
5 7/8
6 1/4
6 3/8
PT 8303 SL EL - measurements in inches
4
24 3/8 3 1/2
5 1/4
9 1/4
13 3/8
10 1/8
12 1/4
66 7/8
66 7/8
10 1/8
PT 8303 SL EL - measurements in inches
5
70 7/8
3/4
5 1/8
1 3/8
1 3/8
25 1/4
12 5/8
27 7/8
19 1/8
39 7/8
59
39 3/8
2
2
3/8
PT 8303 SL EL - measurements in inches
6
PT 8303 SL EL - measurements in millimeters
5
PT 8303 SL EL - measurements in millimeters
6
PT 8303 SL EL - measurements in millimeters
7
PT 8303 SL EL - measurements in millimeters
8
Technical datasheet: PT 8303 SL EL
Date: 24-Jun-2014
Technical datasheet
Tumble dryer:
Heating:
PT 8303 SL
Electric (EL)
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Machine connections:
Electrical
connection
Standard voltage 3 AC 220 - 240 V
Frequency 60 Hz
Rated load 15.4 kW
Fuse rating 3 x 40 A
Supply lead cross-section 4 x 6 mm² 4 × 10 AWG
Convertible to 3 AC 208 V
Frequency 60 Hz
Rated load 11.7 kW
Fuse rating 3 x 35 A
Supply lead cross-section 4 x 6 mm² 4 x 10 AWG
Convertible to 2 AC 208 V
Frequency 60 Hz
Rated load 8.1 kW
Fuse rating 2 x 40 A
Supply lead cross-section 3 x 6 mm² 3 x 10 AWG
Electrical connection must comply with national regulations.
A wall socket or main isolator must be easily accessible after
installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a trained
electrician.
9
Vented
Nominal air throughput in vented mode
Max. permissible pressure loss
Waste air/gas temperature, max.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a back-
flow of condensate into the machine.
821 m³/h
300 Pa
80 °C
150 mm
150 mm
28993 cfh
0.0435 psi
176 °F
5 15/16
5 15/16
Air intake
Standard Connection:
Air intake from installation site
Min. air intake cross-section
(to prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace
the air extracted.
Alternative connection:
Ducted air intake (from outside
build-
ing)
C
o
n
n
e
c
t
or on machine (int. diameter)
Connection pipe provided on site (int. diameter)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm long and secured using two screws.
531 cm²
161 mm
160 mm
82.305 in²
6 5/16
6 5/16
Technical datasheet: PT 8303 SL EL
Date: 24-Jun-2014
Fittings
(supplied)
Without base
2 x clamps
4 × screws DIN 571 (Ø × length) 6 mm x 40 mm
4 × rawl plugs (Ø × length) 10 mm x 50 mm
1/4 x 1 9/16
3/8 x 2
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Width 711 mm 28“
Depth 1088 mm 42 7/8“
Height 1800 mm 70 7/8
Casing width 708 mm 27 7/8“
Casing depth 999 mm 39 5/16
Minimum width of delivery access to installation site 725 mm 28 9/16
Minimum rear wall gap (measured to front of machine) 1500 mm 59 1/16“
Wall gap (to front of machine)
Minimum gap ensures sufficient space for maintenance and
servicing.
500 mm 19 11/16“
Net weight 139 kg 306.4 lbs
Dynamic floor load, max. 1584 N
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
473 W 1615 BTU/h
Noise level 68.9dB (A)
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
56 dB (A)
Installation should only be carried out by authorized installers in accordance with national regulations! Follow installation
instructions when installing machine!
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Miele 52830366USA Installation Plan

Type
Installation Plan

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI