AUTOMATIC STEAM SHUT-OFF
The humidier has an automatic steam off function, which
will be activated in the following cases:
a) If during operation of appliance the water level drops
below the required level, a safety switch automatically
stops the appliance operation, preventing it from
overheating. At the same time you will hear a triple beep,
the operation indicators on buttons will ash, reminding
of the need to ll the water tank.
In the sleep mode, only the symbol „ ” is
blinking on the LCD.
If within one minute, the water tank is not lled, the air
humidier automatically turns off.
If at the time of lling the water tank the
appliance will automatically switch off, after
installing the water tank on the humidier’s
base, press the “ON/OFF” button to restart the
appliance.
b) During operation, removing the water tank or incorrect
installation of the tank on the base of air humidier
will launch a safety switch that automatically stops
the appliance, preventing it from overheating. If within
15 seconds the water tank will not be placed on the
humidier’s base, you will hear three beeps and the
indicators on the buttons will ash.
In the sleep mode, only the symbol „ ” is
blinking on the LCD.
After placing the water tank on the humidier’s base, the
appliance within 3 seconds will return to normal operation
mode. However, if within one minute the water tank will not be
placed on the humidier’s base, the appliance automatically
turns off.
If the appliance was automatically switched
off after installing the water tank on the
humidier’s base, press the “ON/OFF” button
to restart the appliance.
DRAINING THE BASE OF HUMIDIFIER
1
Turn the appliance off by pressing the “ON/OFF” button
and unplug the power cord from the wall outlet.
2
Remove the water tank from the base of the humidier,
lifting it up with the handle.
3
Empty the base of the humidier removing the
accumulated water (as shown in the photo).
Pouring water out in the wrong way may result
in water entering the outlet of the fan and
consequently cause serious damage to the
humidier.
If water gets into the fan outlet, contact your
service center.
E
Between 60-85% RH - the amount of generated steam –
is being reduced, on the “MODES” button one operation
indicator shall fade,
Above 85% RH - production of steam shall be ceased , –
the display shows “H% RH”. When the level of humidity
in the room drops to 60% RH, the appliance shall resume
production of steam.
The “MODES” button is used to manually select the
operation mode. When the appliance is started, pressing
a single button will switch from automatic mode to manual
mode, while reducing the amount of generated steam (the
operation indicator on the “AUTO” button and one segment
of the indicator on the “MODES” button shall fade). Pressing
the button again starts the function of sleep and shall reduce
the amount of generated steam (the second segment of
indicator on the “MODES” button will fade and the display
will show the symbol „ ”).
During the sleep function you cannot control
the amount of generated steam. Pressing any
button (except the “ON/OFF”) will disable the
sleep function and increase the amount of
generated steam.
Pressing the “MODES” button shall turn off the sleep function
and increase the amount of generated steam (both segments
of the operation indicator on the “MODES” button will be lit).
The “ION” button is used to activate the ionization. The air
humidier has a built-in generator which produces negative
ions that improve air quality and help to improve your health.
After pressing the “ION” button, the appliance will produce
negative ions, the operation indicator on the button will light
up. At any time you can turn this function off, by pressing
again the “ION” button.
The function of ionization does not work in
sleep mode.
The “AUTO” button lets you switch from manual to
automatic mode, by pressing the button, operation indicator
on the button will light up. To disable the automatic mode,
press the “MODES” button.
STARTING THE APPLIANCE
1
Connect the power cord into an electrical outlet.
The display and operation indicators on the
buttons will turn to illuminate to indicate the
appliance is connected to the supply mains.
2
Press “ON/OFF” button. You will hear the “tune”, air
humidier will run in automatic mode. Operation indicators
on the button “ON/OFF”, “AUTO” and “MODES” will ash
and the display shows the level of humidity in the room.
Do not operate the appliance if the water tank
is empty.
3
To turn the appliance off, press the “ON / OFF” button. The
display and operation indicators on the buttons will be off.
C