  • Hello! I am an AI chatbot trained to assist you with the Amerec AX Steamer Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AX STEAMER SERVICE INSTRUCTIONS:
LEVEL PROBE PATCH
4211-1511 04/14/2020 Technical Support 1-425-951-1102 1-800-363-0251 Support@amerec.com
The AX Level Probe Patch Kit is intended to reduce the risk of false errors related to water level sensing, such as
a
SHORTED ELECTRODE. You should have (2) identical patches in your kit with quick-connect terminal lugs on each
end as shown here. The patch installs between the circuit board and the level probe
on the blue and white wires. We recommend adding the probes at the circuit board
end of the wires as shown below. Make sure all connectors are tight after installation is complete.
Turn off all power to the steamer while installing the patch kit!
Make sure only one patch is installed per wire!
DO NOT place a patch on the black wire!
WHITE WIRE
BLUE WIRE
LEVEL PROBE:
IMPORTANT: Connect
Black wire to tall rod
White wire to tall rod
Blue wire to short rod
WITHOUT PATCHES
WITH PATCHES
PATCHES INSTALLED
BLACK WIRE
/