Middle Atlantic Products C5MM1-4255D Installation Instructions Manual

Type
Installation Instructions Manual

This manual is also suitable for

I-00559 Rev C
C5MM1 Series
UNIVERSAL MONITOR MOUNT
installation instructions
THANK YOU
Thank you for purchasing the C5MM1 Series Universal Mount. Please read these instructions
thoroughly before installing this product.
- Safely and easily mounts large format monitors to C5 / C5-D Credenza
- Proprietary extruded uprights for a sleek appearance
- Structural members made from heavy-duty 11 gauge steel
- Fully adjustable in height, with laser cut increments for precise adjustment
- Cable management clips included
PRODUCT FEATURES
Vertical Mounting
Brackets (Qty 2) and
Locking Clips
(Pre-Installed)
(Qty 2)
1/4”-20 Set Screws (Qty 4)
End Caps
(Qty 2)
Columns (Qty 2) and
Shoulder Bolt Plates
(Pre-Installed)
(Qty 2)
Angle Brackets (Qty 2)
MAXIMUM FLAT-PANEL WEIGHT LIMIT
TOOLS REQUIRED
• #2 Phillips Screwdriver
• 1/4” Allen Wrench
• Protective Eyewear
• Adjustable Wrench
• Torque Wrench
• 5/16” Wrench (C5-D Only)
HARDWARE/ITEMS SUPPLIED
NOTE: Additional hardware may be included.
Page 2
1/4”-20
Machine
Screws
(Qty 2)
(Tighten to
76 in-lbs)
1/4”-20
Flange Nuts
(Qty 2)
(Tighten to
76 in-lbs)
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING ALERTS YOU TO A SITUATION
THAT COULD RESULT IN SERIOUS PERSONAL INJURY
OR DEATH.
!
!
IMPORTANT WARNINGS AND CAUTIONS!
WARNING! FAILURE TO READ, UNDERSTAND AND
FOLLOW THE FOLLOWING INFORMATION CAN
RESULT IN SERIOUS PERSONAL INJURY, DAMAGE TO
THE EQUIPMENT OR VOIDING OF THE WARRANTY. IT
IS THE RESPONSIBILITY OF THE INSTALLER/USER TO
ENSURE THAT THIS PRODUCT IS LOADED
ACCORDING TO SPECIFICATIONS.
WARNING! THE WEIGHT RATINGS OF THIS PRODUCT
CAN BE FOUND ON THE PRODUCT. EXCEEDING
THESE WEIGHT RATINGS CAN RESULT IN SERIOUS
INJURY OR DAMAGE TO THE EQUIPMENT. IT IS
THE RESPONSIBILITY OF THE INSTALLER/USER TO
ENSURE THE COMPONENTS INSTALLED ON THIS
MONITOR MOUNT DO NOT SURPASS THE WEIGHT
RATINGS AS AN UNSTABLE CONDITION CAN OCCUR
WHICH MAY CAUSE POSSIBLE INJURY OR DAMAGE.
!
!
CAUTION! TO AVOID AN UNSTABLE CONDITION,
MONITORS MUST BE CENTERED ON THE HORIZONTAL
MONITOR MOUNTING BRACKET.
NOTE: A NOTE is used to highlight procedures pertaining
to the installation, operation or maintenance of the product.
WARNING! ANTI-TIP FEET MUST BE INSTALLED -
FAILURE TO DO SO COULD RESULT IN PROPERTY
DAMAGE, SERIOUS PERSONAL INJURY, OR DEATH.
!
!
CAUTION! SAFETY MEASURES MUST BE PRACTICED
AT ALL TIMES DURING THE ASSEMBLY OF THIS
PRODUCT. USE PROPER SAFETY EQUIPMENT
AND TOOLS FOR THE ASSEMBLY PROCEDURE TO
PREVENT PERSONAL INJURY.
!
WEIGHT RATING
C5MM1-4270S (42” to 70” single monitors)
C5MM1-4255D (42” to 55” dual monitors)
C5MM1-5665D (56” to 65” dual monitors)
DETAILS
225 lbs.
160 lbs. each (320 lbs. total)
160 lbs. each (320 lbs. total)
CAUTION: A CAUTION ALERTS YOU TO A SITUATION
THAT MAY RESULT IN MINOR PERSONAL INJURY OR
DAMAGE TO THE PRODUCT AND / OR PROPERTY.
Cable Management Clips
(Qty 6)
1/2”-13 Machine
Screws (Qty 2)
(Tighten to
500 in-lbs)
1/8” Allen Wrench (Qty 1)
Thread Depth Indicator
(Qty 1)
5/16” Flat Washers
(Qty 10)
Upper Mounting
Plates (Qty 2)
M5 x 12
(Qty 8)
M6 x 12
(Qty 8)
M4 x 16
(Qty 8)
(Qty 6)
M5 x 16
(Qty 6)
M5 x 20
M6 x 20
(Qty 6)
M8 x 20
(Qty 6)
1/4”-20
Machine
Screws
(Qty 4)
1/4”-20
Flange Nuts
(Qty 4)
HARDWARE/ITEMS SUPPLIED (Continued)
Page 3
2) Slide back the Top Surface of the Credenza to allow room to install the Bottom Plate as shown.
(FIGURE B)
(Qty 4)
M4 x 25
(Qty 4)
M5 x 25
M8 x 25
(Qty 6)
M8 x 30
(Qty 6)
M8 x 35
(Qty 4)
(Qty 8)
M5 x 50
M8 x 70
(Qty 4)
Horizontal Mounting Bracket
(For C5MM1-4270S -or-
C5MM1-4255D -or-
C5MM1-5665D)
(Qty 1)
Threaded Pins (Qty 2)
Universal Washers
(Qty 8)
#10 x 5/8” Pan Head Phillips
Wood Screws (Qty 16)
5/16”-18 Machine Bolts (Qty 4)
(Tighten to 135 in-lbs)
Anti-Tip Feet (Qty 2)
Level (Qty 1)
C5 3-BAY Center Bar
Supports (Qty 2)
PARTS SUPPLIED WITH 3-BAY C5 WOOD KIT:
#10-32 x 3/8” Thread
Forming Screws for C5-D
Anti-Tip Feet (Qty 8)
C5-D Center Bar
Supports (Qty 2)
SUPPLIED WITH C5-D
WOOD KIT
1/4” Large Nylon Spacers
(Qty 6)
1/2” Large Nylon Spacers
(Qty 12)
1” Nylon Spacers
(Qty 6)
1/4” Small Nylon Spacers
(Qty 6)
Nylon Spacers
(Qty 4)
1/2” Small Nylon Spacers
(Qty 6)
C5 INSTALLATION
1) 3-BAY C5 CREDENZA ONLY: Install (2) C5 3-BAY
center bar supports using (2) 1/4”-20 machine screws
and (2) 1/4”-20 flange nuts as shown. (FIGURE A)
2) Remove machine screws at rear of C5
credenza as shown using provided 1/8” allen
wrench (4 places). (FIGURE B)
3) Install anti-tip feet using existing machine screws.
Adjust feet so they touch floor. (FIGURE B, FIGURE C)
FIGURE B
Machine Screws (2)
2) Slide back the Top Surface of the Credenza to allow room to install the Bottom Plate as shown.
(FIGURE B)
(FIGURE A)
(FIGURE C)
Hardware ‘A’ Joins Plate
and Base to Top Surface
Bottom Plate Hole Pattern
(Plate ‘A’)
2a) Install the Bottom Plate and Tube Base to the
Top Surface using the supplied flathead screws
(Hardware ‘M’). (FIGURE C)
2b) Secure the Top Surface to the Credenza Frame before
continuing with the Monitor Mount installation. Please
see C5 Series Credenza Rack instructions (I-00439)
for detailed instructions.
B
A
M
Page 4
Machine Screws (2)
1/4”-20
FIGURE A
Flange Nuts (2)
1/4”-20
C5 3-BAY Center Bar
Supports (2)
4) Secure both angle brackets to rear of frame as
show using (1) 1/4”-20 machine screw and
(1) 1/4”-20 flange nut. (FIGURE D, FIGURE E)
5) Place C5 top surface on credenza frame, and insert
(1) 1/2”-13 machine screw through each corner bracket,
into frame and through C5 top surface as shown.
(FIGURE E)
NOTE: Hold screws in place to prevent
from falling out.
Flange Nut (1) 1/4”-20 Angle Bracket (1)
Machine Screw (1)
1/4”-20
FIGURE D
FIGURE C
(Inside) (Outside)
Machine Screws
(1 per bracket)
1/2”-13
FIGURE E
C5 Top Surface
Angle Brackets (2)
Angle Bracket (1)
Machine Screw (1)
1/4”-20
FIGURE I
C5-D INSTALLATION
1) Install anti-tip feet using (4) 10-32 x 3/8” thread
forming screws as shown (5/16” wrench required).
Adjust feet so they touch floor. (FIGURE F, FIGURE G)
2) Place (2) C5-D center bar supports on C5-D credenza,
with threaded mounting holes facing rear of
credenza. Align with slots as shown. (FIGURE H)
FIGURE F
Page 5
FIGURE H
3) Secure (2) angle brackets and (2) C5-D center
bar supports to rear of frame using 1/4”-20
machine screws. (FIGURE I, FIGURE J)
NOTE: Screws must penetrate and be tightly
secured to threaded holes in rear of
C5-D center bar supports.
4) Place C5-D top surface on credenza frame, and
insert (1) 1/2”-13 machine screw through
each corner bracket, into frame and through
C5-D top surface as shown. (FIGURE J)
NOTE: Hold screws in place to prevent
from falling out.
Machine Screws (1 per bracket) 1/2”-13
FIGURE J
C5-D Top Surface
Angle Brackets (2)
FIGURE G
Slot
C5-D Center Bar
Supports (2)
Thread Forming Screws
(4) 10-32 x 3/8”
Slot
Threaded
Mounting
Hole
C5-D Center Bar
Support
Flat Hex Head
Machine Screw (2)
5/16”-18
Machine Screws
(1 per bracket)
1/2”-13
Top Surface
Shoulder
Bolt Plate
Shoulder
Bolt
Columns (2)
Threaded
Pins (2)
Upper
Mounting
Plates (2)
4) Hang horizontal mounting bracket by
shoulder bolts on columns to determine
desired height. (FIGURE M)
NOTE: Columns are marked in
one-inch height increments.
NOTE: Teardrop shoulder bolt holes
indicate the proper orientation of the
horizontal mounting bracket.
5) If necessary, remove horizontal mounting
bracket and loosen (2) 5/16-18 flat hex head
machine screws on shoulder bolt plate to adjust
height up and down. (FIGURE N)
NOTE: Use provided level to ensure horizontal bracket is level.
6) When desired position is reached, hang horizontal
mounting bracket on shoulder bolts.
7) Tighten (2) 5/16-18 flat hex head machine screws to 15 ft-lbs.
DO NOT OVERTIGHTEN. (FIGURE N)
C5 / C5-D INSTALLATION
1) Position upper mounting plates over 1/2”-13 machine
screws on C5 / C5-D Top Surface and secure threaded
pins onto machine screws. (FIGURE K)
T
ighten machine screws and threaded pins to 40 ft-lbs.
Use adjustable wrench on flats of threaded pins.
2) Secure C5 / C5-D Top Surface to credenza frame.
(Refer to Assembly Instructions for C5 Series
Credenza Rack I-00439 or C5-D Series
Deep Credenza Rack I-00565)
3)
Place columns over threaded pins (FIGURE K) and
rotate columns so that set screw holes face the rear of
C5 / C5-D credenza. Do not tighten. (FIGURE L)
Column
Set Screws
(2 per column)
1/4”-20
Page 6
FIGURE K
FIGURE L
FIGURE N
!
Teardrop Hole
Shoulder
Bolts
Horizontal
Mounting
Bracket
Columns
FIGURE M
!
TIGHTEN
TO 15 FT-LBS
FIGURE P
Selecting The Mounting Hardware To Attach Brackets To Flat Panel
1) Identify the correct diameter screw for the flat panel threaded inserts. The correct screws should
thread easily and not pull out when tension is applied.
2) To determine proper screw length, insert thread depth indicator into a
threaded insert on the flat panel.
3) Mark the thread depth indicator 1/8” above the
depth of the threaded insert. (FIGURE P)
4) Select a screw that is shorter than the 1/8” mark
made on the thread depth indicator.
CAUTION! Do not use any screw longer than the 1/8”
mark or damage to the flat panel may occur.
Small Straw
or toothpick
Depth Plus 1/8”
Mark Allowance
Small Straw
or toothpick
Depth Plus 1/8”
Allowance Mark
Thread Depth Indicator
Threaded Insert
Mark 1/8” Above Depth
!
C5 / C5-D INSTALLATION (Continued)
Page 7
8) Tighten set screws (4 places) using 1/8” allen wrench. (FIGURE L)
9) Secure horizontal mounting bracket to columns using (4) 5/16”-18 machine bolts.
Tighten bolts to 15 ft-lbs. DO NOT OVERTIGHTEN. (FIGURE O)
FIGURE O
Horizontal Mounting Bracket
Machine Bolts (4) 5/16”-18
!
TIGHTEN TO 15 FT-LBS
FIGURE Q
FIGURE R
M8
M6
M5
M4
Dimples (Face Up)
Attaching Vertical Mounting Brackets to Flat Panel
NOTE: Be sure to observe the “up” arrow on each vertical
mounting bracket to maintain the proper orientation of the
flat panel. (FIGURE R)
1) Place the flat panel face down on a soft, flat surface and
identify the number and location of screws.
2) Align the holes on each vertical mounting bracket with the
threaded inserts on the flat panel.
3) Secure each vertical mounting bracket with the
screws and hardware identified in previous
steps. Use a minimum of (2) screws per vertical
mounting bracket.
Universal Washers
Universal washers are designed to accommodate
the various M4, M5, M6 and M8 hole sizes found in
flat panels.
NOTES:
• Place flat panel on soft, flat surface while working.
Do not place excessive pressure on back of the flat
panel.
• Universal washers must be installed between
the head of the mounting screw and the
vertical mounting bracket as shown.
(FIGURE Q)
Nylon Spacers
Nylon spacers add distance between vertical mounting
bracket and flat panel. They will fit all supplied screw sizes.
The spacers must be used only when attaching flat panels
which have:
• Recessed mount points
• Uneven mount points
• Any obstruction near the mount points
• A curved back
NOTES:
• Nylon Spacers must be stacked and oriented as shown.
• Nylon Spacers must only be installed between the vertical
mounting bracket and the flat panel.
Flat Panel
Universal Washer
Nylon Spacer
Mounting Bracket
Mount Point
Mounting Screw
Page 8
“Up” Arrow
C5 / C5-D INSTALLATION (Continued)
Hanging the Flat Panel
NOTE: This section requires two people.
Do not release your flat panel until you
are certain that the top hook of each
vertical mounting bracket is securely
seated on the upper rail of the horizontal
mounting bracket.
1) Remove locking clips from vertical mounting
bracket and rotate locking clamps down.
(FIGURE S)
2) Raise the flat panel slightly above the top
and bottom rails on the horizontal mounting
bracket. (FIGURE S)
3) Slide the flat panel down slowly, ensuring
that the top hook on the vertical mounting
bracket properly engages the horizontal
mounting bracket. (FIGURE S)
4) Check for proper height.
(Remove and adjust height as necessary)
5) Rotate locking clamps up and insert
locking pins as shown. (FIGURE T)
6) Snap end caps into the top of both columns.
(FIGURE U)
7) Snap cable management clips into columns to
secure cabling as needed. (FIGURE U)
Top
Hook
Bottom
Hook
FIGURE S
Page 9
ADETAIL
Locking Clamp
Horizontal
Mounting
Bracket
FIGURE T
Vertical Mounting
Bracket
FIGURE U
FIGURE U
Cable
Management
Clips
C5 / C5-D INSTALLATION (Continued)
Page 10
30% Recycled Paper
WARRANTY
Middle Atlantic Products (the "Company") warrants the C5MM1 Series Universal Monitor Mount to be
free from defects in material or workmanship under normal use and conditions for the lifetime of the
product.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and
exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of
and refund of the price paid for, or (b) repair or replacement at the Company's factory of the products
purchased, or any part or parts thereof, which the Company has determined to be defective after
inspection thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by
parties other than the Company, or any modification or alteration of the products. In addition, this
warranty does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY
BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS,
BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF THE
PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER PARTY)
HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS
PAID TO THE COMPANY.
Corporate Headquarters
Corporate Voice 973-839-1011 - Fax 973-839-1976
International Voice +1 973-839-8821 - Fax +1 973-839-4982
middleatlantic.com - [email protected]
Middle Atlantic Canada
Voice 613-836-2501 - Fax 613-836-2690
middleatlantic.ca - [email protected]
Factory Distribution
USA: NJ - CA - IL Canada: ON - BC
At Middle Atlantic Products we are always listening. Your comments are welcome.
Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Middle Atlantic Products C5MM1-4255D Installation Instructions Manual

Type
Installation Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI