ABB AC500 Series Installation Instructions Manual

  • Hello! I am an AI chatbot trained to assist you with the ABB AC500 Series Installation Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AC500 Product Family
Installation Instructions
TECHNICAL DOCUMENTATION
Read this manual prior to performing any task!
3ADR024117M02xx, 4, en_US
© 2017
ABB Automation Products GmbH
Eppelheimer Straße 82
69123 Heidelberg, Germany
Telephone: +49 62 21 701 1444
Fax: +49 62 21 701 1382
Internet: www.abb.com/PLC
25.07.2017AC500 Product Family Installation Instructions2
Table of contents
1
PM56xx-2ETH........................................................................................................................................ 4
2 TB56xx-2ETH....................................................................................................................................... 10
3 TU5xx(-XC)........................................................................................................................................... 17
4 DO526(-XC).......................................................................................................................................... 25
5 CM582-DP(-XC).................................................................................................................................... 32
6 CM589-PNIO(-4)(-XC).......................................................................................................................... 38
Table of contents
25.07.2017 AC500 Product Family Installation Instructions 3
1 PM56xx-2ETH
n PM5630-2ETH
n PM5650-2ETH
n PM5670-2ETH
n PM5675-2ETH
Fig. 1: PM5650-2ETH
PM56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions4
CAUTION!
Risk of injury and damaging the PLC modules!
Improper installation and maintenance may result in injury and can damage the PLC modules!
Installation and maintenance have to be performed according to the technical rules, codes and rel-
evant standards, e.g. EN 60204-1.
Only by skilled electricians.
Recycling
Disposal and Recycling Information
This symbol on the product (and on its packaging) is in accordance with the European Union's Waste
Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be
recycled/disposed of separately from other household waste. It is the end user’s responsibility to dis-
pose of this product by taking it to a designated WEEE collection facility for the proper collection and
recycling of the waste equipment. The separate collection and recycling of waste equipment will help
to conserve natural resources and protect human health and the environment. For more information
about recycling, please contact your local environmental office, an electrical/electronic waste disposal
company or the store where you purchased the product.
PM56xx-2ETH
25.07.2017 AC500 Product Family Installation Instructions 5
Assembly
The CPU is put on the Terminal Base - CPU clicks in.
Disassembly
Press above and below
.
Remove the CPU.
PM56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions6
Dimensions
PM5650
mounted on TB5620.
Attention!
The CPUs PM56xx-2ETH with 2 onboard ETH (1SAPxxx000R0278) can only be used with T
erminal
Base TB56xx-2ETH (1SAPxxx300R0278).
PM56xx-2ETH
25.07.2017 AC500 Product Family Installation Instructions 7
Connection
Status displays (7-segment)
Triangle displays for ”Item”
Square displays for ”Status”
Status LEDs
Pushbuttons
MC: Slot for the SD Memory Card
TA525: Label
see note
The connection part may be different on various Terminal Base types. See installation instructions of
the specific T
erminal Base suitable for this CPU for connection specifications.
Cleaning instruction
Do not use cleaning agent for cleaning the device.
Use a damp cloth instead.
PM56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions8
PM56xx-2ETH
25.07.2017 AC500 Product Family Installation Instructions 9
2 TB56xx-2ETH
n TB5600-2ETH
n TB5610-2ETH
n TB5620-2ETH
n TB5640-2ETH
Fig. 2: TB5620-2ETH
TB56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions10
CAUTION!
Risk of injury and damaging the PLC modules!
Improper installation and maintenance may result in injury and can damage the PLC modules!
Installation and maintenance have to be performed according to the technical rules, codes and rel-
evant standards, e.g. EN 60204-1.
Only by skilled electricians.
Recycling
Disposal and Recycling Information
This symbol on the product (and on its packaging) is in accordance with the European Union's Waste
Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be
recycled/disposed of separately from other household waste. It is the end user’s responsibility to dis-
pose of this product by taking it to a designated WEEE collection facility for the proper collection and
recycling of the waste equipment. The separate collection and recycling of waste equipment will help
to conserve natural resources and protect human health and the environment. For more information
about recycling, please contact your local environmental office, an electrical/electronic waste disposal
company or the store where you purchased the product.
TB56xx-2ETH
25.07.2017 AC500 Product Family Installation Instructions 11
Assembly
The Terminal Base is put on the DIN rail above and then snapped-in below.
Disassembly
Pull down the T
erminal Base
and remove it.
TB56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions12
Assembly with screws
TA526 are snapped on the rear side of the Terminal Base like DIN rails. One TA526 is turned by 180°.
The insertion of the accessories TA526 for screw mounting is essential.
TB56xx-2ETH
25.07.2017 AC500 Product Family Installation Instructions 13
Fasten Terminal Base with 3 (M4, max 1.2 Nm) screws (front view).
Dimensions
TB56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions14
Connection
I/O-Bus
Slot for the CPU
Slots for Communication Module
Interface for CAN
Supply for 24 V DC
Serial interface COM1
Network interface
Holes for screw mounting (ø 4 mm)
CAN
24 V
TB56xx-2ETH
25.07.2017 AC500 Product Family Installation Instructions 15
COM 1
ETHERNET
Cleaning instruction
Do not use cleaning agent for cleaning the device.
Use a damp cloth instead.
TB56xx-2ETH
25.07.2017AC500 Product Family Installation Instructions16
3 TU5xx(-XC)
n TU515 24 V DC
n TU531 230 V AC
n TU541 24 V DC
n TU516(-XC) 24 V DC
n TU532(-XC) 230 V AC
n TU542(-XC) 24 V DC
CAUTION!
Risk of injury and damaging the PLC modules!
Improper installation and maintenance may result in injury and can damage the PLC modules!
Installation and maintenance have to be performed according to the technical rules, codes and rel-
evant standards, e.g. EN 60204-1.
Only by skilled electricians.
TU5xx(-XC)
25.07.2017 AC500 Product Family Installation Instructions 17
TU5xx-XC
XC = eXtreme Conditions
Symbol for XC module
Recycling
Disposal and Recycling Information
This symbol on the product (and on its packaging) is in accordance with the European Union's W
aste
Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be
recycled/disposed of separately from other household waste. It is the end user’s responsibility to dis-
pose of this product by taking it to a designated WEEE collection facility for the proper collection and
recycling of the waste equipment. The separate collection and recycling of waste equipment will help
to conserve natural resources and protect human health and the environment. For more information
about recycling, please contact your local environmental office, an electrical/electronic waste disposal
company or the store where you purchased the product.
TU5xx(-XC)
25.07.2017AC500 Product Family Installation Instructions18
Assembly
The Terminal Unit is put on the DIN rail above and then snapped-in below.
Disassembly
Shove the T
erminal Units from each other.
TU5xx(-XC)
25.07.2017 AC500 Product Family Installation Instructions 19
Pull down the T
erminal Unit
and remove it.
TU5xx(-XC)
25.07.2017AC500 Product Family Installation Instructions20
/