SICK GTB6L Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the SICK GTB6L Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
O P E R A T I N G I N S T R U C T I O N
GTB6L
Miniature photoelectric sensors
O P E R A T I N G I N S T R U C T I O N
GTB6L
Miniature photoelectric sensors
de
en
es
fr
it
ja
pt
ru
zh
Described product
G6L
GTB6L
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Production location
SICK Malaysia
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
Laser
1
2006/42/EC
NO
SAFETY
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
3
Contents
1 General safety notes......................................................................... 5
2 Notes on UL approval........................................................................ 5
3 Intended use...................................................................................... 5
4 Operating and status indicators...................................................... 5
5 Mounting............................................................................................. 6
6 Electrical installation........................................................................ 7
7 Commissioning.................................................................................. 8
7.1 Alignment.................................................................................................. 8
7.2 Sensing range........................................................................................... 8
7.3 Settings..................................................................................................... 9
8 Troubleshooting................................................................................. 10
9 Disassembly and disposal............................................................... 10
10 Maintenance...................................................................................... 11
11 Technical specifications................................................................... 12
11.1 Dimensional drawing................................................................................ 13
11.2 Light spot diagram.................................................................................... 13
CONTENTS
4
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
1 General safety notes
Read the operating instructions before commissioning.
Connection, mounting, and configuration may only be performed by trained
specialists.
2006/42/EC
NO
SAFETY
Not a safety component in accordance with the EU Machinery Directive.
When commissioning, protect the device from moisture and contamination.
These operating instructions contain information required during the life cycle of
the sensor.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATTENTION
WARNING: Interruption, manipulation or incorrect use can lead to hazardous exposure
due to laser radiation.
2 Notes on UL approval
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
3 Intended use
The GTB6L is an opto-electronic photoelectric proximity sensor (referred to as “sensor”
in the following) for the optical, non-contact detection of objects. If the product is used
for any other purpose or modified in any way, any warranty claim against SICK AG shall
become void.
4 Operating and status indicators
Photoelectric proximity sensor with background suppression.
GENERAL SAFETY NOTES 1
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
5
GTB6L-xxx1x
1
2 3
23
1
1
Potentiometer: sensitivity adjustment
2
Yellow LED indicator: Switching output
3
LED indicator green: supply voltage active
GTB6L-xxx3x
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
2 3
23
5 Mounting
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the preferred orientation of the sensor relative to the direction of object motion,
refer to figure 1.
Figure 1: Sensor orientation relative to object direction
4
OPERATING AND STATUS INDICATORS
6
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
6 Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed depending on the connection type:
Plug connection: pin assignment
Cable: wire color
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established.
Explanation of connection terminology:
BN = Brown
WH = White
BU = Blue
BK = Black
n. c. = no connection
Q = switching output 1
Q = switching output 2
L+ = supply voltage (Uv)
M = common
L.ON = light operate
D.ON = dark operate
Connection and Output detail:
Table 1: DC
GTB6L -P1xxx
-N1xxx
-E2xxx
-F2xxx
-P3xxx
-N3xxx
-P5xxx
-N5xxx
-P4xxx
-N4xxx
-P6xxx
-N6xxx
-P7xxx
-N7xxx
-E4xxx
-F4xxx
-E6xxx
-F6xxx
-E7xxx
-F7xxx
1 = BN + (L+) + (L+) + (L+) + (L+) + (L+)
2 = WH -
Q
- n. c.
Q
3 = BU - (M) - (M) - (M) - (M) - (M)
4 = BK Q Q Q Q Q
0.205 mm
2
/
AWG24
0.205 mm
2
/
AWG24
1
4
3
2
1
4
3
2
1
4
3
Table 2: Output function
GTB6L
ELECTRICAL INSTALLATION 6
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
7
-Px1xx
-Px2xx
-Px3xx
-Px4xx
L.ON, PNP: Q ( 100 mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
-Px1xx
-Px2xx
-Px5xx
-Px6xx
D.ON, PNP: Q ( 100 mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
-Nx1xx
-Nx2xx
-Nx3xx
Nx4xx
L.ON, NPN Open Collector Q ( 100 mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Load
-Nx1xx
-Nx2xx
-Nx5xx
-Nx6xx
D.ON, NPN Open Collector Q ( 100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
7 Commissioning
7.1 Alignment
Align sensor on object. Select the position so that the red emitted light beam hits the
center of the object. You must ensure that the optical opening (front screen) of the
sensor is completely clear [see figure 2].
Figure 2: Alignment
7.2 Sensing range
Adjust the mounting position so that the sensing range and background are within
specification. Refer to see figure 3, page 9.
NOTE
Please note the minimum range of 5 mm.
7 COMMISSIONING
8
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
Use see table 2, page 7 to check the function. If the switching output fails to behave in
accordance with see table 2, page 7, check the application conditions.
Figure 3: GTB6L
1
Sensing range on black, 6% remission
2
Sensing range on gray, 18% remission
3
Sensing range on white, 90% remission
7.3 Settings
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensing range is adjusted with the potentiometer (type: 5-turn). Clockwise rotation:
sensing range increased; counterclockwise rotation: sensing range reduced. We recom‐
mend placing the object within the sensing range, e.g. see figure 3. Once the sensing
range has been adjusted, the object is removed from the path of the beam, which
causes the background to be suppressed and the switching output to change [see
table 2].
Table 3: Adjustment sensing range
COMMISSIONING 7
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
9
The sensor is adjusted and ready for operation.
8 Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 4: Troubleshooting
LED indicator/fault pattern Cause Measures
Yellow LED does not light up
even though the light beam is
aligned to the object and the
object is within the set sensing
range
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions Ensure there is a stable power
supply without interruptions
Sensor is faulty If the power supply is OK,
replace the sensor
Yellow LED flashes Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
object / Clean the optical sur‐
faces / Check sensing range
and adjust if necessary
Yellow LED lights up, no object
in the path of the beam
The sensing range distance is
too large
Reduce the sensing range
Object is in the path of the
beam, yellow LED does not
light up
Distance between the sensor
and the object is too long or
sensing range is set too short
Reduce the sensing range
9 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
8 TROUBLESHOOTING
10
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE: This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
10 Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
MAINTENANCE 10
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
11
11 Technical specifications
GTB6L
Laser class 1
Sensing range 30 ... 400 mm
Sensing range max. 10 ... 400 mm
1)
Light spot diameter/distance 0.4 mm / 150 mm
Supply voltage U
B
DC 10 ... 30 V
2)
Output current I
max.
100 mA
3)
Switching frequency 1,000 Hz
4)
Max. response time 0.625 ms
5)
Enclosure rating IP67
Protection class III
Circuit protection A, C, D
6)
Ambient operating temperature -20 ... +50 °C
7)
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit values. U
B
connections reverse-polarity protected. Residual ripple max 5 V
PP
3)
As of U
B
> 24 V, a max. load current I
max.
= 50 mA is permitted.
4)
With light / dark ratio 1:1
5)
Signal transit time with resistive load
6)
A = U
B
-connections reverse polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
7)
As of T
a
45 °C, a max. supply voltage U
B
= 24 V and a max. load current I
max.
= 50 mA is permitted.
11 TECHNICAL SPECIFICATIONS
12
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
11.1 Dimensional drawing
10.2 (0.4)
6.9 (0.27)
0.5
(0.02)
21
(0.83)
0.5
(0.02)
9.7
(0.38)
3
(0.12)
11.5
(0.45)
31.5 (1.24)
28.5 (1.12)
25.4 (1.00)
2.3
(0.09)
18.3
(0.72)
305 (12.01)
9.7
(0.38)
12
(0.47)
1
2
4
4
3
Figure 4: Dimensional drawing
1
Center of optical axis, sender
2
Center of optical axis, receiver
3
Operating and status indicators
4
M3 threaded mounting hole
11.2 Light spot diagram
Sensor
Ø 0.4
(0.02)
Ø 2.2
(0.09)
Ø 1.8
(0.07)
Ø 4.6
(0.18)
Distance in mm (inch)
Diameter in mm (inch)
25
(0.98)
150
(5.91)
250
(9.84)
400
(15.75)
TECHNICAL SPECIFICATIONS 11
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
13
23 Consignes générales de sécurité
Lire la notice d’instruction avant la mise en service.
Le raccordement, le montage et la configuration ne doivent être réalisés
que par un personnel qualifié.
2006/42/EC
NO
SAFETY
N’est pas un composant de sécurité selon la Directive machines de l’UE.
Lors de la mise en service, protéger l’appareil contre l’humidité et la conta‐
mination.
Cette notice d’instruction contient des informations nécessaires durant le cycle de
vie du capteur.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATTENTION
ATTENTION : Toute intervention, manipulation ou utilisation non conforme peuvent
provoquer une exposition dangereuse aux rayons laser.
24 Remarques sur l’homologation UL
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
25 Utilisation conforme
GTB6L est un détecteur à réflexion directe optoélectronique (appelé capteur dans ce
document) qui permet la détection optique sans contact d’objets. Toute autre utilisation
ou modification du produit annule la garantie de SICK AG.
26 Afficheurs d’état et de fonctionnement
Détecteur à réflexion directe avec élimination d’arrière-plan.
CONSIGNES GÉNÉRALES DE SÉCURI 23
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
29
33.1 Plan coté
10.2 (0.4)
6.9 (0.27)
0.5
(0.02)
21
(0.83)
0.5
(0.02)
9.7
(0.38)
3
(0.12)
11.5
(0.45)
31.5 (1.24)
28.5 (1.12)
25.4 (1.00)
2.3
(0.09)
18.3
(0.72)
305 (12.01)
9.7
(0.38)
12
(0.47)
1
2
4
4
3
Illustration 12: Plan coté
1
Centre de l’axe optique émetteur
2
Centre de l’axe optique récepteur
3
Éléments de commande et d'affichage
4
Taraudage M3
33.2 Schéma du spot lumineux
Sensor
Ø 0.4
(0.02)
Ø 2.2
(0.09)
Ø 1.8
(0.07)
Ø 4.6
(0.18)
Distance in mm (inch)
Diameter in mm (inch)
25
(0.98)
150
(5.91)
250
(9.84)
400
(15.75)
CARACTÉRISTIQUES TECHNIQUES 33
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
37
M A N U A L D E I N S T R U Ç Õ E S
GTB6L
Barreiras de luz miniatura
de
en
es
fr
it
ja
pt
ru
zh
34 Instruções gerais de segurança
Leia o Manual de instruções antes de colocar em operação.
A conexão, montagem e configuração podem ser efetuadas apenas por
técnicos especializados treinados.
2006/42/EC
NO
SAFETY
Este não é um componente de segurança em conformidade com a diretriz
de Máquinas da UE.
Ao colocar em operação, proteja o dispositivo contra umidade e conta‐
minação.
Este Manual de instruções contém as informações necessárias para operação
durante a vida útil do sensor.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATENÇÃO
AVISO: A interrupção, manipulação ou uso incorreto podem levar à exposição perigosa
devido à radiação laser.
35 Indicações sobre a homologação UL
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
36 Especificações de uso
O GTB6L é um sensor optoeletrônico de reflexão (a seguir denominado “sensor”)
utilizado para a detecção ótica e sem contato de objetos. Qualquer utilização diferente
ou alterações do produto ocasionam a perda da garantia da SICK AG.
INSTRUÇÕES GERAIS DE SEGURANÇA 34
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
41
45 Avvertenze di sicurezza generali
Prima di eseguire la messa in servizio, leggere le istruzioni per l’uso.
Il collegamento, il montaggio e la configurazione devono essere eseguiti
esclusivamente da personale tecnico qualificato.
2006/42/EC
NO
SAFETY
Non è un componente di sicurezza ai sensi della Direttiva Macchine UE.
Durante la messa in servizio, proteggere il dispositivo dall’umidità e da
possibili contaminazioni.
Le presenti Istruzioni per l’uso contengono informazioni necessarie durante il ciclo
di vita del sensore.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATTENZIONE
ATTENZIONE: l’interruzione, la manipolazione o l’uso improprio possono causare
un’esposizione pericolosa dovuta a radiazioni laser.
46 Indicazioni sull’omologazione UL
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
47 Uso conforme alle disposizioni
GTB6L è un sensore fotoelettrico energetico (di seguito detto sensore) utilizzato per il
rilevamento ottico senza contatto di oggetti. Se viene utilizzato diversamente e in caso
di modifiche del prodotto, decade qualsiasi diritto alla garanzia nei confronti di SICK.
48 Indicatori di uso e di funzionamento
Sensori fotoelettrici energetici con soppressione dello sfondo.
AVVERTENZE DI SICUREZZA GENERALI 45
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
53
56 Indicaciones generales de seguridad
Lea las instrucciones de uso antes de realizar la puesta en servicio.
Únicamente personal especializado y debidamente cualificado debe llevar
a cabo las tareas de conexión, montaje y configuración.
2006/42/EC
NO
SAFETY
No se trata de un componente de seguridad según las definiciones de la
directiva de máquinas de la UE.
Al realizar la puesta en servicio, el dispositivo se debe proteger frente a la
humedad y la contaminación.
Las presentes instrucciones de uso contienen la información necesaria para todo
el ciclo de vida del sensor.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATENCIÓN
ADVERTENCIA: La intervención, la manipulación y el uso incorrecto pueden causar una
situación de riesgo de exposición a radiación láser.
57 Indicaciones sobre la homologación UL
The device shall be supplied from an isolating transformer having a secondary overcu‐
rrent protective device that complies with UL 248 to be installed in the field rated
either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
58 Uso conforme a lo previsto
La GTB6L es una fotocélula optoelectrónica de detección sobre objeto (en lo sucesivo
llamada sensor) empleada para la detección óptica y sin contacto de objetos. Cualquier
uso diferente al previsto o modificación en el producto invalidará la garantía por parte
de SICK AG.
INDICACIONES GENERALES DE SEGURIDAD 56
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
65
66.1 Dibujo acotado
10.2 (0.4)
6.9 (0.27)
0.5
(0.02)
21
(0.83)
0.5
(0.02)
9.7
(0.38)
3
(0.12)
11.5
(0.45)
31.5 (1.24)
28.5 (1.12)
25.4 (1.00)
2.3
(0.09)
18.3
(0.72)
305 (12.01)
9.7
(0.38)
12
(0.47)
1
2
4
4
3
Figura 24: Dibujo acotado
1
Centro del eje óptico del emisor
2
Centro del eje óptico del receptor
3
Elementos de mando y visualización
4
Rosca de fijación M3
66.2 Diámetro del spot
Sensor
Ø 0.4
(0.02)
Ø 2.2
(0.09)
Ø 1.8
(0.07)
Ø 4.6
(0.18)
Distance in mm (inch)
Diameter in mm (inch)
25
(0.98)
150
(5.91)
250
(9.84)
400
(15.75)
DATOS TÉCNICOS 66
8025391.193N / 28.08.2020 | SICK
Subject to change without notice
73
/