Hirschmann MACH104 PoEP User manual

Category
Networking
Type
User manual
Installation MACH104-PoEP
Release
11
12/2020
Technical support
https://hirschmann-support.belden.com
User Manual
Installation
Industrial Ethernet Workgroup Switch
MACH104-PoEP Full Gigabit Family
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
1
2
3
4
13
14
15
16
17
18
19
20
5
6
7
8
9
10
11
12
x y
MACH104
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
1
2
3
4
13
14
15
16
17
18
19
21 22
20
5
6
7
8
9
10
11
12
x y
MACH104
MACH104-16TX-PoEP+2X...
MACH104-16TX-PoEP+2X-R...
MACH104-16TX-PoEP+2X-E...
MACH104-16TX-PoEP...
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP-E...
2020-12-18
Installation MACH104-PoEP
Release
11
12/2020
The naming of copyrighted trademarks in this manual, even when not specially indicated, should
not be taken to mean that these names may be considered as free in the sense of the trademark
and tradename protection law and hence that they may be freely used by anyone.
© 2020 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site
(www.hirschmann.com).
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Installation MACH104-PoEP
Release
11
12/2020
3
Contents
Important information 6
Safety instructions 8
About this manual 17
Key 18
1 Description 19
1.1 General device description 19
1.2 Device name and product code 20
1.3 Device variants available 20
1.4 Device views 21
1.4.1 Front view 21
1.4.2 Rear view 22
1.5 Supply voltage 22
1.5.1 MACH104-16TX-PoEP... und MACH104-16TX-
PoEP+2X... 23
1.5.2 MACH104-16TX-PoEP-R... und MACH104-16TX-
PoEP+2X-R... 23
1.5.3 MACH104-16TX-PoEP-E... und MACH104-16TX-
PoEP+2X-E... 23
1.6 Ethernet ports 23
1.6.1 10/100/1000 Mbit/s twisted pair port 24
1.6.2 100 Mbit/s F/O port 24
1.6.3 1000 Mbit/s F/O port 25
1.6.4 10-Gbit/s F/O port 25
1.6.5 PoE ports 25
1.6.6 Combo ports 26
1.6.7 SFP/XFP transceiver 27
1.7 Display elements 27
1.7.1 Device state 28
1.7.2 Port status 29
1.8 Management interfaces 30
1.8.1 V.24 interface (external management) 30
4
Installation MACH104-PoEP
Release
11
12/2020
1.8.2 USB interface 30
1.9 Signal contact 31
2 Installation 32
2.1 Checking the package contents 32
2.2 Installing an SFP transceiver (optional) 32
2.3 MACH104-16TX-PoEP-E...,
MACH104-16TX-PoEP+2X-E...:
Wiring and installation of the supply voltage 33
2.4 Wiring and installing the signal contact 34
2.5 Installing the device and grounding 35
2.5.1 Selecting the assembly location 35
2.5.2 Mounting on a flat surface 35
2.5.3 Mounting in a switch cabinet 36
2.5.4 Mounting on the wall 37
2.5.5 Grounding the device 37
2.6 Operating the device 38
2.7 Connecting data cables 38
3 Making basic settings 39
3.1 Default settings 39
3.2 First login (Password change) 40
4 Maintenance and service 41
5 Deinstallation 42
5.1 Removing the device 42
5.2 Removing an SFP transceiver (optional) 42
6 Technical data 43
6.1 General technical data 43
6.2 Dimension drawings 45
6.3 EMC and immunity 46
6.4 Network range 47
6.5 Power consumption/power output 52
Installation MACH104-PoEP
Release
11
12/2020
5
7 Scope of delivery, order numbers and
accessories 53
8 Underlying technical standards 57
A Further support 58
6
Installation MACH104-PoEP
Release
11
12/2020
Important information
Note: Read these instructions carefully, and familiarize yourself with the
device before trying to install, operate, or maintain it. The following notes may
appear throughout this documentation or on the device. These notes warn of
potential hazards or call attention to information that clarifies or simplifies a
procedure.
Symbol explanation
This is a general warning symbol. This symbol alerts you to
potential personal injury hazards. Observe all safety notes that
follow this symbol to avoid possible injury or death.
If this symbol is displayed in addition to a safety instruction of the
type “Danger” or “Warning”, it means that there is a danger of
electric shock and failure to observe the instructions will
inevitably result in injury.
This symbol indicates the danger of hot surfaces on the device.
In connection with safety instructions, non-observance of the
instructions will inevitably result in injuries.
DANGER
DANGER draws attention to an immediately dangerous situation, which will
inevitably result in a serious or fatal accident if not observed.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
CAUTION indicates a possible danger which, if not avoided, may result in
minor injuries.
Installation MACH104-PoEP
Release
11
12/2020
7
NOTICE
NOTE provides information about procedures that do not involve the risk of
injury.
8
Installation MACH104-PoEP
Release
11
12/2020
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device
entails the risk of physical injury or significant property damage. The
proper and safe operation of this device depends on proper handling
during transportation, proper storage and installation, and careful
operation and maintenance procedures.
Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.
The device is free of any service components. In case of a damaged
or malfunctioning device, turn off the supply voltage and return the
device to Hirschmann for inspection.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all
the data transmission devices individually.
Before you start any machine which is controlled via data transmission, be
sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
Installation MACH104-PoEP
Release
11
12/2020
9
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 43.
Connect to the product only components suitable for the requirements
of the specific application case.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Connect only PoE-supplier devices whose data connections are
located in the interior of the building and are specified as SELV circuits
according to IEC 60950-1 or ES1 according to IEC/EN 62368-1.
Grounding the device
The device is grounded via the power supply connections.
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the
requirements listed are complied with.
Requirements for connecting the supply voltage
Before connecting the supply voltage, always verify that the requirements
listed are complied with.
The following requirements apply without restrictions:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
Only switch on the device when the casing is closed.
Relevant for North America:
Exclusively use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire.
Prerequisites:
All of the following requirements are complied with:
10
Installation MACH104-PoEP
Release
11
12/2020
The supply voltage corresponds to the voltage specified on the type plate of the device.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (for example a switch or
a plug). This disconnecting device is clearly identified. So in the case of an emergency, it is
clear which disconnecting device belongs to which power supply cable.
This applies to the following device variants only:
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-R...
Unplug every non-heating device coupling to disconnect the device from the power supply.
This applies to the following device variants only:
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-R...
The wire diameter of the power supply cable is at least 1 mm² (North America: AWG16) on
the supply voltage input.
The cross-section of the ground conductor is the same size as or bigger than the cross-
section of the power supply cables.
The power supply cable is suitable for the voltage, the current and the physical load.
Hirschmann recommends a conductor cross section of 0.5 mm² to 0.75 mm² (AWG20 up to
AWG18).
This applies to the following device variants only:
MACH104-16TX-PoEP-E...
MACH104-16TX-PoEP+2X-E...
Install an input fuse with a maximum rating of 10 A, characteristic B, into the supply line to
the voltage input.
The following requirements apply alternatively:
Relevant when the device is supplied via 1 voltage input:
Alternative 1 The power supply complies with the requirements for a limited power source
(LPS) according to IEC 60950-1 or PS2 according to IEC/EN 62368-1.
Alternative 2 Relevant for North America:
The power supply complies with the requirements according to NEC Class 2.
Alternative 3 All of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-low
voltage (SELV) according to IEC 60950-1 or ES1 according to IEC/
EN 62368-1.
Supply with DC voltage:
A back-up fuse suitable for DC voltage is located in the plus conductor of
the power supply.
The minus conductor is on ground potential. Otherwise, a back-up fuse is
also located in the minus conductor.
Regarding the properties of this back-up fuse:
See “Technical data” on page 43.
Supply with AC voltage:
A fuse is located in the outer conductor of the power supply.
The neutral conductor is on ground potential at both voltage inputs.
Otherwise, a fuse is also located in the neutral conductor.
Regarding the properties of this fuse:
See “Technical data” on page 43.
Relevant when the device is supplied via 2 voltage inputs:
Alternative 1 The total voltage supply complies with the requirements for a limited power
source (LPS) according to IEC 60950-1 or IEC/EN 62368-1.
Alternative 2 Relevant for North America:
The total voltage supply complies with the requirements as per NEC Class 2.
Prerequisites:
Installation MACH104-PoEP
Release
11
12/2020
11
Supply voltage
The supply voltage is connected to the device casing through protective
elements exclusively.
The supply voltage is electrically isolated from the casing.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
inside of the device.
Keep the ventilation slits free to ensure good air circulation.
Make sure there is at least 3.94 in (10 cm) of space in front of the
ventilation slits of the casing.
Mount the device horizontally or vertically, either as a desktop device,
in the switch cabinet (figure 7 on page 36) or on the wall (figure 8 on
page 37).
In order to fix the device to a concrete wall choose screws with a
thread major diameter of at least 5 mm.
Alternative 3 All of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-low
voltage (SELV) according to IEC 60950-1 or ES1 according to IEC/
EN 62368-1.
Supply with DC voltage:
A fuse suitable for DC voltage is located at both voltage inputs in the plus
conductor of the power supply.
The minus conductor is on ground potential at both voltage inputs.
Otherwise, a fuse is also located in the minus conductor.
Regarding the properties of this fuse:
See “Technical data” on page 43.
Supply with AC voltage:
A fuse is located at both voltage inputs in the outer conductor of the power
supply.
The neutral conductor is on ground potential at both voltage inputs.
Otherwise, a fuse is also located in the neutral conductor.
Regarding the properties of this fuse:
See “Technical data” on page 43.
Prerequisites:
12
Installation MACH104-PoEP
Release
11
12/2020
Installation site requirements
Operate the device at the specified ambient temperature (temperature of
the ambient air at a distance of 2 in (5 cm) from the device) and at the
specified relative humidity exclusively.
When you are selecting the installation location, make sure you
observe the climatic threshold values specified in the technical data.
Use the device in an environment with a maximum pollution degree
that complies with the specifications in the technical data.
If the device is not installed in a horizontal position, it must be installed
in a switch cabinet or other fire enclosure. The fireenclosure can be
made of metal or plastic with fire protection properties of at least V-1
according to IEC 60695-11-10. Bottom openings must NOT exceed
2 mm in diameter.
Strain relief
Note: If the strain relief is insufficient, there is a risk of torsion, contact
problems and creeping interruptions.
Relieve the connection points of cables and lines from mechanical
stress.
Design strain relieves in such a way that they prevent any mechanical
damage to cables, wires or conductors caused by external influences
or their own weight.
To prevent damage to device connections, connectors and cables,
follow the instructions for proper installation in accordance with DIN
VDE 0100-520:2013-06, sections 522.6, 522.7 and 522.13.
CE marking
The labeled devices comply with the regulations contained in the following
European directive(s):
Device variant Directive
MACH104-16TX-PoEP...
MACH104-16TX-PoEP+2X...
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-R...
MACH104-16TX-PoEP-E...
MACH104-16TX-PoEP+2X-E...
2011/65/EU and 2015/863/EU (RoHS)
Directive of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment.
2014/30/EU (EMC)
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to
electromagnetic compatibility.
MACH104-16TX-PoEP...
MACH104-16TX-PoEP+2X...
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-R...
2014/35/EU
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to the
making available on the market of electrical equipment
designed for use within certain voltage limits.
Installation MACH104-PoEP
Release
11
12/2020
13
In accordance with the above-named EU directive(s), the EU conformity
declaration will be at the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
You find the EU conformity declaration as PDF file for downloading on the
Internet at: https://www.doc.hirschmann.com/certificates.html
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2
Emitted interference: EN 55032
Safety: EN 62368-1
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.
Note: The assembly guidelines provided in these instructions must be
strictly adhered to in order to observe the EMC threshold values.
LED or laser components
LED or LASER components according to IEC 60825-1 (2014):
CLASS 1 LASER PRODUCT
CLASS 1 LED PRODUCT
14
Installation MACH104-PoEP
Release
11
12/2020
FCC note
Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information
MACH104-PoEP
U.S. Contact Information
Belden – St. Louis
1 N. Brentwood Blvd. 15th Floor
St. Louis, Missouri 63105, United States
Phone: 314.854.8000
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
BSMI note for use in Taiwan
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.
Devices with a specification according to BSMI standards CNS 13438,
CNS 14336-1 and CNS 15663 are marked on the device label.
᝾֋٬Ҕޣ;!
೭ࢂҘᜪޑၗૻౢ ࠔǴӧۚՐޑᕉნύ٬ҔਔǴёૈ཮೷ԋ৔ᓎυᘋǴӧ೭
௃ݩΠǴ٬Ҕޣ཮೏ा؃௦ڗࢌ٤፾྽ޑჹ฼Ƕ
D45625
RoHS
Installation MACH104-PoEP
Release
11
12/2020
15
Declaration o
f
hazardous substances according to
C
hinese regulatory standar
d
R
estr
i
cte
d
su
b
stances an
d
t
h
e
i
r c
h
em
i
ca
l
sym
b
o
l
Lead
M
ercur
y
C
admium Hexavalent
C
hromiu
m
P
o
l
y
b
rom
i
nate
d
bi
p
h
eny
l
s
P
o
l
y
b
rom
i
nate
d
di
p
h
eny
l
et
h
ers
C
omponent
eta
components
P
r
i
nte
d
c
i
rcu
i
t
b
oar
d
assem
bly
Ҕނ፦֖Ԗ௃ݩ኱Ңᖂܴ
ൂϡ
ߎឦ೽ҹ
೛ഢӜᆀǺҬඤᐒǴࠠဦȐࠠԄȑǺ
MACH104-20TX-F...
MACH104-20TX-FR...
MACH104-20TX-F-4PoE...
Equipment name:
S
witch, Model desi
g
nation:
ज़Ҕނ፦ϷځϯᏢ಄ဦ
؄ᙿ
Ϥሽ
ӭྜྷᖄश
ӭྜྷΒश⾸
ႝၡኳಔ
༟ጤکᆫ!ӝނ೽ҹ
ႝྍϡҹ
P
ower supp
l
y un
i
t
ഢԵIJįġȺຬрıįIJġŸŵġĦȻϷȺຬрıįıIJġŸŵġĦȻ߯ࡰज़Ҕނ፦ϐԭϩК֖ໆຬрԭϩК֖ໆ୷ྗॶǶ
Note 1: “Exceeding 0.1 wt%” and “exceeding 0.01 wt%” indicates that the amount of the restricted substance within the component exceeds the
reference percentage limit
.
Note 2:
“O
” indicates that the amount o
f
the restricted substance does not exceed the re
f
erence percentage limit.
Note 3:
X” indicates that the amount o
f
the restricted substance corresponds with the exemption.
ഢԵijįȺOȻ߯ࡰ၀໨ज़Ҕނ፦ϐԭϩК֖ໆ҂ຬрԭϩК֖ໆ୷ྗॶǶ
ഢԵĴįȺXȻ߯ࡰ၀໨ज़Ҕނ፦ࣁ௨ନ໨ҞǶ
16
Installation MACH104-PoEP
Release
11
12/2020
Recycling note
After usage, this device must be disposed of properly as electronic waste,
in accordance with the current disposal regulations of your county, state,
and country.
Installation MACH104-PoEP
Release
11
12/2020
17
About this manual
The “Installation” user manual contains a device description, safety
instructions, a description of the display, and the other information that you
need to install the device.
The following manuals are available as PDF files on the Internet on the
Hirschmann product pages (www.hirschmann.com):
Installation user manual
Basic Configuration user manual
Redundancy Configuration user manual
Reference manual for the graphical user interface
Command Line Interface reference manual
The Network Management Software Industrial HiVision provides you with
options for smooth configuration and monitoring. You find further information
on the Internet at the Hirschmann product pages:
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
18
Installation MACH104-PoEP
Release
11
12/2020
Key
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Installation MACH104-PoEP
Release
11
12/2020
19
1 Description
1.1 General device description
The MACH104-PoEP family provides you with a range of device variants.
The device is designed for the special requirements of industrial automation.
The device meets the relevant industry standards, provides very high
operational reliability, even under extreme conditions, and also long-term
reliability and flexibility.
The devices with software variant L2... allow you to set up switched industrial
Ethernet networks that conform to the IEEE 802.3 standard.
The devices with software variant L2... allow you to set up switched and
routed industrial Ethernet networks that conform to the IEEE 802.3 standard.
The device works without a fan.
The following installation options are available:
19" switch cabinet
Mounting on a flat surface
You have the option of choosing various media to connect to the end devices
and other network components:
Twisted pair cable
Multimode F/O
Singlemode F/O
The ring redundancy concept allows the network to be reconfigured quickly
after a failure.
There are convenient options for managing the device. Manage your devices
via:
Web browser
Telnet
Network management software (for example Industrial HiVision)
V.24 interface (locally on the device)
The device provides you with a large range of functions, which the manuals
for the operating software inform you about. You can download these
manuals as PDF files from the Internet on the Hirschmann product pages
(http://www.doc.hirschmann.com).
The Hirschmann network components help you ensure continuous
communication across all levels of the company.
20
Installation MACH104-PoEP
Release
11
12/2020
1.2 Device name and product code
The device name corresponds to the product code. The product code is
made up of characteristics with defined positions. The characteristic values
stand for specific product properties.
1.3 Device variants available
Under “Accessories and order numbers” on page 53 you can see which
device variants are available.
Item Product
characteristic
Characteristi
c value
Description
1 ... 17 Basic properties
of all device
variants
MACH104-
16TX-PoEP
Industrial Ethernet Workgroup Switch with:
4 × 1000-Mbit/s Combo Ports
16 × 1000-Mbit/s Twisted-Pair Ports with
PoE+
18 + x Special
properties of the
device variants
Blank Rated voltage range
100 V AC ... 240 V AC, 50 Hz ... 60 Hz
-R
Rated voltage range
100 V AC ... 240 V AC, 50 Hz ... 60 Hz
Redundant power supply
-E For the use of type-1-powered devices (PoE):
Rated voltage
48 V DC
For the use of Type 2 Powered Devices (PoE+):
Rated voltage
54 V DC
+2X
Additionally: 2 × 10-Gbit/s F/O ports
Rated voltage range
100 V AC ... 240 V AC, 50 Hz ... 60 Hz
+2X-R
Additionally: 2 × 10-Gbit/s F/O ports
Rated voltage range
100 V AC ... 240 V AC, 50 Hz ... 60 Hz
Redundant power supply
+2X-E Additionally: 2 × 10-Gbit/s F/O ports
For the use of type-1-powered devices (PoE):
Rated voltage
48 V DC
For the use of Type 2 Powered Devices (PoE+):
Rated voltage
54 V DC
Last 4
positions
Software variant -L2P Layer 2 Professional
-L3P Layer 3 Professional
Table 1: Device name and product code
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Hirschmann MACH104 PoEP User manual

Category
Networking
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI