GE Appliances IND403 Installation guide

Type
Installation guide

GE Appliances IND403 is a Lumination® LED luminaire designed for replacing diffusers in LBT and LBR series lighting fixtures. It is intended for indoor use and requires professional installation by a qualified electrician. The luminaire is dimmable and comes with various diffuser options for LBT14, LBT24, LBR22, LBR14, LBR24, and LBT22 series fixtures. It features easy installation and removal, allowing for quick diffuser replacements.

GE Appliances IND403 is a Lumination® LED luminaire designed for replacing diffusers in LBT and LBR series lighting fixtures. It is intended for indoor use and requires professional installation by a qualified electrician. The luminaire is dimmable and comes with various diffuser options for LBT14, LBT24, LBR22, LBR14, LBR24, and LBT22 series fixtures. It features easy installation and removal, allowing for quick diffuser replacements.

Installation Guide
IND403
Lumination® LED Luminaire
Diuser Replacement
(LBT/LBR Series)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before inspection, installation or removal.
Properly ground electrical enclosure.
RISK OF FIRE
Follow all NEC and local codes
Use only UL approved wire for input/output connections.
Only use size 18 AWG (0.75mm
2
).
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire.
Assurez-vous de correctement mettre à la terre le boîtier d’alimentation
électrique.
RISK OF FIRE
Respectez tous les codes NEC et codes locaux.
N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Utilisez taille 18 AWG (0.75mm
2
).
Description Code Corresponding Luminaires
LBT22 (dimmable) diuser LBT22 series
LBT14 (dimmable) diuser LBT14 series
LBT24 (dimmable) diuser LBT24 series
LBR22 (dimmable) diuser LBR22 series
LBR14 (dimmable) diuser LBR14 series
LBR24 (dimmable) diuser LBR24 series
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Specications
2
Lumination® (LBT/LBR - Series) Installation Guide
TURN OFF POWER at the source
to the luminaire.
1
Disconnect the AC and dimming
wires. Remove the xture from
the ceiling xture.
2
Remove the end cap that is
opposite to the driver/electrical
box.
3
LBT Diuser Replacement Steps
NOTE: The following steps depict the 22 Series luminaire. However, the procedure is the same for the 14 and 24 Series xtures.
Slide out the old diuser.
4
Slide in the new diuser. Make sure
the round corner on the diuser
slides in rst as shown in the circled
area of the above picture.
NOTE: Rough side of diuser should fave
UP in this orientation.
5
Replace the end cap.
6
Install the xture back to the ceiling.
Connect the AC and dimming wires.
7
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
IND403 (Rev 04/02/21)
Lumination® (LBT/LBR - Series) Installation Guide
Rotate latches to unlock the front
bezel.
1
Swing down panel and lift o front
bezel with diuser.
2
Place front bezel with diuser on
table. Unfasten the two rail screws on
the end rail with latches, then remove
this end rail.
3
Locate round corner here
LBR Diuser Replacement Steps
NOTE: The following steps depict the 22 Series luminaire. However, the procedure is the same for the 14 and 24 Series xtures.
Remove the old diuser by sliding
it toward the side without end rail.
Insert new diuser, keeping the round
corner of diuser on bottom left.
NOTE: Rough side of diuser should face
UP in this orientation.
4
Locate round corner here
Reattach end rail with screws.
5
Hang panel on its hinges and swing
up into place. Rotate latches on front
bezel to fasten it.
6
  • Page 1 1
  • Page 2 2
  • Page 3 3

GE Appliances IND403 Installation guide

Type
Installation guide

GE Appliances IND403 is a Lumination® LED luminaire designed for replacing diffusers in LBT and LBR series lighting fixtures. It is intended for indoor use and requires professional installation by a qualified electrician. The luminaire is dimmable and comes with various diffuser options for LBT14, LBT24, LBR22, LBR14, LBR24, and LBT22 series fixtures. It features easy installation and removal, allowing for quick diffuser replacements.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages