3M Aqua-Pure 5621102 User manual

  • Hello! I am an AI chatbot trained to assist you with the 3M Aqua-Pure 5621102 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation and Operating Instructions for
AP902/AP903 Series
Whole House Water Filters
3M
Water Filtration Products
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
Before starting installation, shut off main water supply and drain pipes.
• Installation and Use MUST comply with all state and local plumbing codes.
Protect from freezing, remove cartridge when temperatures are expected to drop below 40° F (4.4° C);
• Do not install on hot water supply lines. The maximum operating water temperature of this fi lter system is 100°F (37.8°C).
Do not install if water pressure exceeds 125 psi (689 kPa). If your water pressure exceeds 80 psi (552 kPa) you must install a pressure
limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check for this condition.
Do not use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if overtightening occurs.
Do not install in direct sunlight or outdoors.
Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system when installed.
• Ensure all tubing and fi ttings are secure and free of leaks.
The disposable fi lter cartridge MUST be replaced every 12 months, at the rated capacity or sooner if a noticeable reduction in fl ow rate occurs.
Read, understand, and follow all safety information contained in these instructions
prior to installation and use of the 3M™ Water Filtration Products AP902/AP903 Series
Whole House Water Filters. Retain these instructions for future reference.
The AP902/AP903 Series Whole House Water Filters are intended for use in fi ltering potable water
in Whole House applications and have not been evaluated for other uses. These fi lters are typically
installed at the point-of-entry, and must be installed as specifi ed in the installation instructions.
To reduce the risk associated with choking:
Do not allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area
of installation:
• Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the fi lter bracket.
To reduce the risk of physical injury:
• Depressurize system as shown in manual prior to cartridge removal.
To reduce the risk associated with back strain:
• Follow safe lifting procedures.
WARNING
CAUTION
Installer: Please leave this manual with owner/operator.
Homeowner: Please retain for operation and future maintenance instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.
CAUTION
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property damage.
CAUTION
CAUTION
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
• Failure to follow instructions will void warranty.
• Allow a minimum of 3” (7.6 cm) clear space under fi lter to facilitate cartridge change.
Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• Some local codes may require the use of a licensed plumber or certifi ed installer when disrupting a potable water line.
IMPORTANT NOTES
Assembly schematic is based on suggested materials. Assembly of this filter can be modified by using various adapters.
Parts and Materials Included:
1) Filter Head
2) Filter Cartridge — AP902 includes AP910R and AP903 includes AP917HD
3) Bracket
Tools and Materials Required (not included):
Gather the required tools before starting installation.
Read and follow the instructions provided with any tools listed here.
A) Pipe Cutter
B) Two 1” Sweat connections
C) 2” Ball Valve (Sweat Type)
D) Plumbers Tape
E) Adjustable Wrench
F) Torch (not shown)
G) Plumbing Solder (not shown)
H) Plumbing Flux (not shown)
GETTING STARTED
City Water Installation
Well Water Installation
Master
Shut-Off
Valve
To Household
Plumbing
Pump
Master
Shut-Off
Valve
To Household
Plumbing
Pressure
Tank
To reduce the risk associated with property damage due to water leakage:
• Installation and Use MUST comply with all state and local plumbing codes.
CAUTION
0 0 0 0 6 9
Gallons
Gallons
2700
2700
3000
3000
Model
Model
BRP
BRP
20
20
10
10
30
30
40
40
50
50
70
70
80
80
90
90
0
Bad
Badg
er Meter
er Meter
300
300
600
600
1600
1600
1800
1800
1200
1200
2100
2100
2400
2400
Water
Meter
A
B
C
D
E
Figure 1
Optional
Bypass Assembly
(recommended)
Optional
Bypass Assembly
(recommended)
IMPORTANT INSTALLATION INSTRUCTIONS
1. Shut off main water supply. Drain water from water lines and open faucet downstream of install location.
2. Remove filter cartridge from filter head and set aside.
3. Cut pipe to length needed to install filter head and recommended bypass.
4. Assemble filter head on optional bypass system as shown in Figure 1. Use three ball valves and one filtration
unit as shown. Use copper pipe and sweated connections to assemble system.
5. Install system (valves, piping and filter head) into water supply system.
6. Use supplied bracket or pipe hangers to support the system.
7. Install filter cartridge into head. Make sure internal key ring is positioned correctly by rotating to the right until it
snaps into place.
8. Turn main water supply back on. While water is running thru faucet, close valves 2 and 3 valve, open valve 1.
9. While water is running through faucet, close valve 1, open valves 2 and 3. Allow filter cartridge to fill up.
10. Check for leaks. Flush no less than 10 gallons (approximately 15 minutes) through system before use.
CAUTION
To reduce the risk associated with property damage due to water leakage:
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if overtightening occurs.
Plumbing Assembly of Optional Bypass and Filtration System
Valve #1
Valve #2 Valve #3
Figure 1
3M Purification Inc. warrants the stainless steel head (excluding disposable fi lter cartridge(s)) to be free from defects in material and workmanship for
twenty-fi ve (25) years from the date of purchase. The disposable filter cartridge or membrane is warranted from defects in material and workmanship
for a period of one (1) year from the date of purchase. This warranty does not cover failures resulting from abuse, misuse, alteration or damage not
caused by 3M Purification Inc. or failure to follow installation and use instructions. No warranty is given as to the service life of any filter cartridge
or membrane as it will vary with local water conditions and water consumption. 3M PURIFICATION INC. MAKES NO OTHER WARRANTIES OR
CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR
USAGE OF TRADE. If the Product fails to satisfy this Limited Warranty during the warranty period, 3M Purification Inc. will replace the Product or
refund your Product purchase price. This warranty does not cover labor. The remedy stated in this paragraph is Customer’s sole remedy and 3M
Purification Inc.’s exclusive obligation.
This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or country to country. For any
warranty questions, please call 1-800-222-7880 or mail your request to: Warranty Claims, 3M Purification Inc., 400 Research Parkway, Meriden,
CT 06450. Proof of purchase (original sales receipt) must accompany the warranty claim, along with a complete description of the Product, model
number and alleged defect.
Limitation of Liability. 3M Purification Inc. will not be liable for any loss or damage arising from this 3M Purification Inc. product, whether direct,
indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Some
states and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not
apply to you.
LIMITED WARRANTY
FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
Filter life depends on local water conditions and the volume of water
used. The disposable filter cartridge MUST be replaced every 12
months, at the rated capacity or sooner if a noticeable reduction in flow
rate occurs.
NOTE: Before changing cartridge, turn off water supply. Place a bucket
under filter to catch the small amount of water that will run out after
cartridge removal.
1. Close shut-off valves before and after filter head (upstream and
downstream valves 2 and 3).
2. Slide cartridge locking latch to the right and lift up.
3. With both hands, twist out filter cartridge by turning unit 90° to the
left and down.
4. Install new replacement cartridge into head by pushing cartridge up
and turning to the right until locking latch clicks into place.
5. Open faucet downstream of filter.
6. Open valves 2 and 3. Flush no less than 10 gallons (approximately 15
minutes) through system before use.
TROUBLESHOOTING GUIDE
Water Leaks at Fittings:
Check solder joints, unions and cartridge and head connection. Shut off water at the main water supply shut-off valve,
remove threaded fittings, reapply PTFE tape in a clockwise (to the right) direction and screw back onto head assembly.
CAUTION
To reduce the risk associated with property damage due to water leakage:
The disposable fi lter cartridge MUST be replaced every 12 months or at the rated capacity or if a noticable reduction
in fl ow rate occurs.
Step 2
Step 3
Step 5
/