Legrand AnyLine Data Module, IS-0290 is designed to be mounted in an On-Q Home enclosure, with two tabs on one end and a locking tab on the other end, allowing for installation in tight spaces. It has four RJ45 jacks labeled DATA 1, DATA 2, DATA 3, and DATA 4 which connect the data signals to a network device, enabling multiple data connections within a single location.

Legrand AnyLine Data Module, IS-0290 is designed to be mounted in an On-Q Home enclosure, with two tabs on one end and a locking tab on the other end, allowing for installation in tight spaces. It has four RJ45 jacks labeled DATA 1, DATA 2, DATA 3, and DATA 4 which connect the data signals to a network device, enabling multiple data connections within a single location.

INSTRUCTION/INSTALLATION SHEET
ANYLINE DATA MODULE IS-0290 REV. O
1. Introduction
The On-Q Home AnyLine Data Module, P/N 364770-01, is designed for retrofit applications where there is an existing
single CAT5 cable and when both a computer connection and telephone connection is desired in an existing location. This
module will support up to 4 locations.
2. Description
The On-Q Home AnyLine Data Module, (see Figure 1) is designed to be mounted in an On-Q Home enclosure, with two
tabs on one end and a locking tab on the other end. It has four RJ45 jacks labeled DATA 1, DATA 2, DATA 3, and
DATA 4 which connect the data signals to a network device. One RJ45 jack labeled PHONE IN L1-L4 receives up to 4
incoming phone lines, and one RJ45 jack labeled PHONE BRIDGE/OUT sends the phone signals to an additional module.
Four 110 punchdown blocks accept the CAT5 cables coming from the wall plates. Associated with these punch down blocks
are four, 3-position DIP switches used to determine which phone line (2 or 3 or 4) gets sent to the room on the Brown pair
of wires (line 1 is always carried on the Blue pair, and the data signals are always carried on the Orange and Green pairs).
Data connections to network device (router/switch)
Bridge/OUT to
additional
module
Phone service IN
from Telecom
Module
Phone and data signals connect to wall plates in rooms (see Figure 6 for punchdown specifics)
AnyLine Data Module
P/N 364770-01
DIP switch
position
determines which
of the phone lines
(2 or 3 or 4) is
connected to the
brown pair. Line 1
is always
connected to the
blue pair.
Figure 1
3. Installation
NOTE: Use proper tools and standard TIA 568A rules to prep and terminate the CAT5 cable, such as the On-Q Home
CAT5 Cable Stripper (P/N 363292-01) and the On-Q Home 110 Punchdown Tool (P/N 363293-01).
NOTE: An RJ45 Jack Insert (P/N 364289-xx) or RJ25 Jack Insert (P/N 364288-xx) must be installed in wall plate to
accommodate phone or data signals (see Figure 4).
Page 1 of 3
301 Fulling Mill Road, Suite G ©Copyright 2004 by OnQ Technologies, Inc All Rights Reserved.
Middletown, PA 17057 www.onqhome.com
(800)-321-2343
Innovations in Home Living.
INSTRUCTION/INSTALLATION SHEET
ANYLINE DATA MODULE IS-0290 REV. O
a. Position the AnyLine Data Module in the enclosure, planning for wire management and location of additional
modules. Position as close to existing telecom module as possible to assure room drops will reach the 110
punchdown blocks on the AnyLine Data Module.
b. Align two stationary tabs on the module with slots on the back of the enclosure (see Figure 2).
c. Insert tabs by angling module away from the back of the enclosure
and sliding forward (see Figure 2).
Step d
Step c
d. Rotate the module and insert the built in locking tab on the
module into the corresponding hole on the back of the
enclosure, pushing in until it snaps into place (see Figure 2).
e. Pull lightly on the module to assure it is properly locked in place.
f. Identify room drops to be used and remove from the telecom
module. Properly prepare the removed cables and terminate on the
AnyLine Data Module’s 110 punch down blocks (see Figures 3
and 6).
Figure 2
g. Connect up to four of the AnyLine Data Module’s RJ45 jacks to the appropriate network device with RJ45 Jumper
cables, such as the On-Q Home RJ45 Jumper Cables, P/N 363201-xx.
h. Connect the incoming phone
service from telecom module to
the AnyLine Data Module’s RJ45
jack labeled ‘PHONE IN L1-L4’.
i. If applicable, connect the
Anyline Data Module’s RJ45
jack labeled ‘PHONE
BRIDGE/OUT’ ’ to an
additional module using an RJ45
Jumper Cable.
j. Move the appropriate DIP switch
(2 or 3 or 4) to the ‘ON’ position
depending upon which phone line
(2 or 3 or 4) should be sent to the
room on the Brown pair of wires
NOTE: Moving more than one
switch will cause a short.
NOTE: Refer to Figures 4 and 5
for instructions concerning the
phone connections on the wall plate.
Brown
White-brown
Green
White-green
Orange
White-orange
Blue
White-blue
Cat5 ms (phone and data) cables to wall plates in roo
RJ45 Jumper Cab
from Telecom
module Bridge Ou
jac
le
t
k
AnyLine Data
Module
white-blue
blue
white-green
green
white-brown
brown
orange
white-orang
e
white-blue
blue
white-green
green
white-brown
brown
orange
white-orang
e
Brown
White-brown
Green
White-green
Orange
White-orange
Blue
White-
b
lue
RJ45 Jumper Cable
from Telecom
module Bridge Out
jack
RJ45 Jumper Cable to additional AnyLine Data Module
4 Port
Router/Switch
Cat5 cables to wall plates in rooms
(phone and data)
Figure 3
Page 2 of 3
301 Fulling Mill Road, Suite G ©Copyright 2004 by OnQ Technologies, Inc All Rights Reserved.
Middletown, PA 17057 www.onqhome.com
(800)-321-2343
Innovations in Home Living.
INSTRUCTION/INSTALLATION SHEET
ANYLINE DATA MODULE IS-0290 REV. O
Cat5 cable coming from
AnyLine Data Module
Orange pair: data Receive
Green pair: data Transmit
Blue pair: phone Line 1
Brown pair: selected phone line
(selected by AnyLine Data Module DIP
switch position)
Wall plate modifications
Figure 4
AnyLine Data Module 110 punch down block specifics
Brown
wires to
Orange
punch
downs
Blue
wires to
Blue
punch
downs
Phone Connection Insert at Wall Plate (Rj45 or RJ25)
Figure 6
Figure 5
IMPORTANT NOTE: The Brown and Brown/White pair of
w
ires which carries the DIP switch selected phone line,
must be connected to the Orange and Orange/White punch downs on the rear of the RJ25 / RJ45 Insert. This will allow
a two line phone to receive calls on the second phone line.
This is NOT the NORMAL 568A punch down sequence.
The RJ45 Wall Plate Insert used for Data follows the standard punch down convention: follow color code.
Page 3 of 3
301 Fulling Mill Road, Suite G ©Copyright 2004 by OnQ Technologies, Inc All Rights Reserved.
Middletown, PA 17057 www.onqhome.com
(800)-321-2343
Innovations in Home Living.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Legrand AnyLine Data Module, IS-0290 Installation guide

Type
Installation guide
This manual is also suitable for

Legrand AnyLine Data Module, IS-0290 is designed to be mounted in an On-Q Home enclosure, with two tabs on one end and a locking tab on the other end, allowing for installation in tight spaces. It has four RJ45 jacks labeled DATA 1, DATA 2, DATA 3, and DATA 4 which connect the data signals to a network device, enabling multiple data connections within a single location.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI