MONESSEN Hearth Aria Vent Free Gas Fireplace Architect Guide

Category
Fireplaces
Type
Architect Guide
Specifications
Additional information can be found online at www.monessenhearth.com
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
Aria 32
Vent Free Fireplace System
37-1/4" [946]
Min. Rough Opening Width
Min. Rough
Opening
Depth
1/2" or 5/8"
Min. Rough
Opening
Height
23-3/8" [594]
37" [940]
32" [813]
34-1/2"
[876]
29" [737]
18-5/8"
[473]
21-3/4"
[553]
6"
[152]
5-7/16"
[138]
16"
[406]
61-3/4"
[1568]
43-3/4" [1111]
43-3/4"
[1111]
33-1/2"
[784]
2-1/2" [64]
15-1/2"
[394]
35"
[889]
Aria VFF32
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH VIEWING AREA
VFF32C
VFF32L
Actual Framing Actual Framing Actual Framing Actual Framing 32 x 21-3/4
37 37-1/4 29 37-1/4 34-1/2 35 18-5/8 15-1/2
Specifications
GS/MON/VFF32_0116
PRODUCT LISTING CODES
US ANSI Z223.1 / NFPA54
ANSI Z21.11
CSA Design Certified
Additional information can be found online at www.monessenhearth.com
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
Paris, KY Phone: (877) 863-4350
Web: www.monessenhearth.com
Aria VFF32
APPLIANCE LOCATION
CLEARANCES TO COMBUSTIBLES
2-1/2"
6"
8"
10"
12"
12"
16"
19"
21"
23"
Combustible
material can
contact top of
fireplace
Non-combustible material
45°
1"
3"
5"
6"
6"
7-1/2"
7-1/2"
4-1/2"
2-1/2"
1-1/2"
3-1/2"
9"
Finish Wall
Combustible
Material Area
MANTEL PROJECTIONS
MANTEL LEG PROJECTIONS
DETERMINE UNIT SIZE
See homowner’s manual for information on determining
the proper size unit for the space required.
9"
Minimum
9"
Minimum
42" Minimum
Back Wall Clearance — The appliance may be
placed against a combustible back wall.
Floor Clearance — The fireplace may be installed
directly on a combustible floor or a raised platform of an
appropriate height. Do not place fireplace on carpeting,
vinyl, tile or other soft floor coverings. It may, however,
be placed on flat wood, plywood, particle board or other
hard surfaces. Be sure fireplace rests on a solid continu-
ous floor or platform with appropriate framing for support
and so that no cold air can enter from under the firebox.