MONESSEN Hearth Symphony Vent Free Gas Fireplace Architect Guide

  • I have analyzed this document, which is an Architect Guide for Monessen Symphony vent-free fireplace systems. It provides detailed specifications for models VFC32C and VFC32L, including dimensions, clearances, and installation guidelines. The document also covers mantle projections and floor requirements. I'm available to help you understand the details from this document.
  • What is the minimum back wall clearance?
    Can this fireplace be installed on carpet?
    What type of floor can this fireplace be placed on?
Specifications
Additional information can be found online at www.monessenhearth.com
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
Symphony 32
Vent Free Fireplace System
32-1/2" [826]
Min. Rough Opening Width
Min. Rough
Opening
Depth
1/2"
or 5/8"
Min. Rough
Opening
Height
17-1/2" [445]
32" [813]
28-3/4" [730]
30"
[762]
25-3/4" [654]
14-1/2"
[368]
19-1/2"
[495]
5-3/4"
[146]
5"
[127]
13-1/8"
[333]
13-3/8"
[340]
41" [1041]
29-1/4"
[743]
58"
[1478]
41"
[1041]
1-5/8" [41]
30-1/4"
[768]
28-3/4" [730]
11-3/8"
[289]
Symphony VFC32
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH VIEWING AREA
VFC32C
VFC32L
Actual Framing Actual Framing Actual Framing Actual Framing 28-3/4 x 19-1/2
32 32-1/2 25-3/4 32-1/2 30 30-1/4 14-1/2 13-3/8
Specifications
GS/MON/VFC32_0116
PRODUCT LISTING CODES
US ANSI Z223.1 / NFPA54
ANSI Z21.11
CSA Design Certified
Additional information can be found online at www.monessenhearth.com
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
Paris, KY Phone: (877) 863-4350
Web: www.monessenhearth.com
CLEARANCES TO COMBUSTIBLES
9"
Minimum
9"
Minimum
42" Minimum
Symphony VFC32
Back Wall Clearance — The appliance may be
placed against a combustible back wall.
Floor Clearance — The fireplace may be installed di-
rectly on a combustible floor or a raised platform of an
appropriate height. Do not place fireplace on carpeting,
vinyl, tile or other soft floor coverings. It may, however,
be placed on flat wood, plywood, particle board or
other hard surfaces. Be sure fireplace rests on a solid
continuous floor or platform with appropriate framing
for support and so that no cold air can enter from under
the firebox.
APPLIANCE LOCATION
2 "
12"
10"
19"
Canopy
FP2508
45°
1"
3"
5"
6"
6"
7-1/2"
7-1/2"
4-1/2"
2-1/2"
1-1/2"
3-1/2"
9"
Finish Wall
Combustible
Material Area
MANTEL PROJECTIONS
MANTEL LEG PROJECTIONS
DETERMINE UNIT SIZE
See homowner’s manual for information on determining
the proper size unit for the space required.
/