MONESSEN Hearth Symphony Vent Free Gas Fireplace Architect Guide

  • Hello! I've reviewed the provided document for the MONESSEN Symphony 24 VFC24C and VFC24L Vent Free Fireplace Systems. This document outlines the specifications as well as clearance requirements for installation. I'm ready to answer any questions you have about these models.
  • What is the viewing area for these fireplace models?
    Can these fireplaces be installed directly on a combustible floor?
    What is the minimum depth for the rough opening?
Specifications
Additional information can be found online at www.monessenhearth.com
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
Symphony 24
Vent Free Fireplace System
25-1/8" [638]
Min. Rough Opening Width
Min. Rough
Opening
Depth
1/2"
or 5/8"
Min. Rough
Opening
Height
16" [406]
24-5/8" [625]
22-5/8" [575]
26-1/2"
[673]
19" [482]
14-1/2"
[368]
16-1/4"
[413]
4-1/2"
[114]
4-7/8"
[124]
13-1/8"
[333]
13-3/8"
[340]
32-1/2" [826]
24"
[610]
44-7/8"
[1140]
32-1/2"
[826]
1" [25]
26-3/4"
[680]
22-3/4" [578]
11-3/8"
[289]
Symphony VFC24
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH VIEWING AREA
VFC24C
VFC24L
Actual Framing Actual Framing Actual Framing Actual Framing 22-5/8 x 16-1/4
24-5/8 25-1/8 19 25-1/8 26-1/2 26-3/4 14-1/2 13-3/8
Specifications
GS/MON/VFC24_0116
PRODUCT LISTING CODES
US ANSI Z223.1 / NFPA54
ANSI Z21.11
CSA Design Certified
Additional information can be found online at www.monessenhearth.com
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
Paris, KY Phone: (877) 863-4350
Web: www.monessenhearth.com
Symphony VFC24
CLEARANCES TO COMBUSTIBLES
9"
Minimum
9"
Minimum
42" Minimum
Back Wall Clearance — The appliance may be
placed against a combustible back wall.
Floor Clearance — The fireplace may be installed
directly on a combustible floor or a raised platform of an
appropriate height. Do not place fireplace on carpeting,
vinyl, tile or other soft floor coverings. It may, however,
be placed on flat wood, plywood, particle board or other
hard surfaces. Be sure fireplace rests on a solid continu-
ous floor or platform with appropriate framing for support
and so that no cold air can enter from under the firebox.
APPLIANCE LOCATION
12"
10"
2-1/2"
19"
Canopy
FP2508
45°
1"
3"
5"
6"
6"
7-1/2"
7-1/2"
4-1/2"
2-1/2"
1-1/2"
3-1/2"
9"
Finish Wall
Combustible
Material Area
MANTEL PROJECTIONS
MANTEL LEG PROJECTIONS
DETERMINE UNIT SIZE
See homowner’s manual for information on determining
the proper size unit for the space required.
/