Hobart Dishwasher FT1000 is a flight-type dishwasher that uses a pumped rinse system and has a water usage of 58 gph. It has digital controls with machine diagnostics, a low temperature alert, and a single point vent location. The machine has 31" access on prewash, power wash and power rinse chambers; 20" access on dual rinse and ASR chambers. It also has start and stop switches at both ends, doors open indicator, drains open indicator, and door interlocks. The FT1000 comes with 31⁄2 H.P. prewash, 5 H.P. power wash and power rinse pump motors, all TEFC, and capless Auto Clean wash arms.

Hobart Dishwasher FT1000 is a flight-type dishwasher that uses a pumped rinse system and has a water usage of 58 gph. It has digital controls with machine diagnostics, a low temperature alert, and a single point vent location. The machine has 31" access on prewash, power wash and power rinse chambers; 20" access on dual rinse and ASR chambers. It also has start and stop switches at both ends, doors open indicator, drains open indicator, and door interlocks. The FT1000 comes with 31⁄2 H.P. prewash, 5 H.P. power wash and power rinse pump motors, all TEFC, and capless Auto Clean wash arms.

Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
F40352 – FT1000 Flight-Type Dishwasher Page 1 of 12
FT1000
FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
FT1000 FLIGHT-TYPE DISHWASHER
STANDARD FEATURES
Pumped rinse system (pressure gauge not
required)
Water usage 58 gph
Digital controls with machine diagnostics
Low temperature alert
Single point vent location
31" access on prewash, power wash and power
rinse chambers; 20" access on dual rinse and
ASR chambers
Start and stop switches at both ends
Doors open indicator
Drains open indicator
Door interlocks
3
1
2 H.P. prewash, 5 H.P. power wash and power
rinse pump motors, all TEFC
Capless Auto Clean wash arms
Easy to remove stainless steel scrap pans and
baskets
30" wide conveyor belt
Dual Rinse
Automatic Soil Removal system (ASR)
Auto Clean
Auto Delime
Ventless technology
Energy Recovery
Front and rear panels
Variable speed conveyor
Electric booster heater
Blower dryer
DIRECTION OF OPERATION
Right to Left
Left to Right
VOLTAGE
208/60/3
240/60/3
480/60/3
Other voltages available – consult factory
MODEL
FT1000 Flight-Type Dishwasher
OPTIONS AT EXTRA COST
Electric Tank Heat
Steam Tank Heat
Multiple conveyor choices
Circuit breakers
Security packages
Other options available, consult factory
ACCESSORIES
Flanged feet
Water hammer arrestor/PRV (installed by others)
Drain water tempering kit (installed by others)
Vent connection kit
Specications, Details and Dimensions on Inside and Back.
LA Research Report M660004
Complies with EPA Reduction of Lead in Drinking
Water Act 2014
Meets requirements of ASSE Standard No. 1004
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 2 of 12 F40352 – FT1000 Flight-Type Dishwasher
DESIGN: Fully automatic, ight-type dish machine
consisting of a load section with Automatic Soil
Removal system, power recirculating prewash, power
wash, power rinse and dual rinse/nal rinse section.
Included with each machine will be exible plastic
strip curtains to control overspray.
CONSTRUCTION: Stainless steel tank and chambers
with No. 3 polish on appearance surfaces. Frame,
legs and feet to be constructed of stainless steel.
Inspection doors to be chamber width.
PUMPS: Recirculating stainless steel pumps with
stainless steel impellers. Pump housing has easy
to remove coverplate for access to impeller. Wash
pumps are self-draining.
MOTORS: Totally enclosed fan cooled (TEFC) design
with overload protection. Pump motors to be 3
1
2
H.P. for prewash, 5 H.P. for power wash and power
rinse, and conveyor motor to be
1
3 H.P. Available in
electrical specications of 208/60/3, 240/60/3 and
480/60/3.
CONTROLS: A stainless steel control center with
electronic digital controls mounted at eye level.
Power “On/Off” and “Start/Stop” switches integrated
into keypad. Digital display indicates door(s) open,
low temperature alert, tanks/nal rinse temperatures,
Auto Clean and Auto Delime instructions and notica-
tions, and other pertinent operating data. Additional
“Start/Stop” switches are located at each end of
machine. Conveyor speed button included on the
control center to provide for the adjustable speed
conveyor.
FLIGHT-TYPE CONVEYOR: Stainless steel side
links, tie rods and conveyor tracks. Injection molded,
resilient Duraex ight links.
VENT: Single exhaust location.
AUTOMATIC SOIL REMOVAL SYSTEM (ASR):
Two foot section with specialized soil removal wash
arms which removes food soil from the ware before it
reaches the prewash tank. System will pump food soil
from the ASR tank into an external collector located
under the load section, minimizing the need to
pre-scrap dishes and reducing detergent consump-
tion. Operator can easily remove and clean external
collector without interruption of machine operation.
RECIRCULATING PREWASH SECTION: Prewash
compartment is tted with upper and lower wash
arms. Large removable one piece perforated stainless
steel screen sloped downward to deep stainless steel
scrap basket.
TANK HEAT: Power wash, power rinse and dual
rinse tank water temperatures are thermostatically
controlled. Low water protection is provided. Specify
either electric or steam heat.
FINAL RINSE: Easily removed nal rinse arms.
VENTLESS ENERGY RECOVERY SYSTEM: Energy
Recovery system operates with a cold water line,
capturing energy from exhaust air, and using it to
elevate the temperature of the cold water. The result
is savings – both in hot water and in energy.
Machine to be equipped with Ventless technology
– an integrated heat pump that will capture the heat
from the waste air and use the recycled energy to
heat the machine’s wash tank, blower dryer and nal
rinse.
CONVEYOR DRIVE UNIT: Powered by a
1
3 H.P.
motor. Trip mechanism provided on unload section.
Jam protection is provided by load sensing switch
at drive platform. Conveyor speed adjustment of 4.0
feet per minute to 8.5 feet per minute is provided on
the digital display keypad.
DRAINS: Manual, hand-operated, located at each
tank. One manual and automatic master drain to be
used for Auto Clean and Auto Delime.
BLOWER DRYER: Blower dryer is heated by the heat
pump system. Includes (2) 2 H.P. fan motors with
sealed ball bearings and overload protection.
FT1000
FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F40352 – FT1000 Flight-Type Dishwasher Page 3 of 12
FT1000
FLIGHT-TYPE DISHWASHER
Variable speed
conveyor offers
increased
throughput.
The conveyor
on the FT1000
Series is wider
so it can handle
more ware.
Result: more volume and versatility, quicker work. Its
speed is easily adjustable for the type of ware, soiled
condition, or workforce requirements. It runs at 4.0 -
8.5 feet per minute.
Advansys systems provide
lowest cost of ownership.
The Energy Recovery
system captures escaping
heat and steam from the
exhaust air and uses it to
preheat the incoming cold
water supply before it enters
the booster heater. The
industry’s only ight-type
ventless system features
heat pump technology, capturing the remaining heat
that passes through the energy recovery system and
uses it to heat the wash tank, blower dryer and nal
rinse, while eliminating the need for a vent hood.
Self-draining wash pumps help keep water clean.
Pumps are self-draining when the machine is shut
down, so there is no residual water left in the pumps.
Installation is quick and easy with modular design
and minimal wiring connections.
Modular design means
the FT1000 installs quickly
and reliably. The control
panel is already in place,
premounted to the dual
rinse/nal rinse section.
Wiring connections are
minimal, saving time and
expense. The control box
uses a “single plane”
circuitry design for easy
accessibility during
installation and service.
The FT1000 is ready to
run quickly.
No other control
system allows
easier monitoring.
The digital controls are
placed in a convenient
panel that lets operators verify proper operation and
temperatures at a glance. Digital display indicates
the unit is on, and conrms that the doors are
closed. Automatic door interlocks prevent the pump
and conveyor from operating if the doors are open.
Easy-to-read digital display indicates accurate
temperatures of the 150°F wash, 160°F power rinse,
160°F dual rinse and 180°F nal rinse — critical for
proper HACCP system record-keeping.
Stainless steel pump is built for long life.
The stainless steel pump housing and impeller offer
greater durability and long life. The pump motor is
totally enclosed and fan cooled (TEFC) to protect it
from water spray during dishroom clean-up.
Scrap baskets
capture food particles
and are easy to clean.
The sloped screens that
carry scraps to the scrap
baskets are steeper, so less
soil gets into the tanks. The basket
opening is larger for easy cleaning and basket
handles have been designed for easy lift-out access.
The load section also features a removable scrap
basket which contains soil that is pumped from the
ASR section. All scrap baskets and strainers are
stainless steel for strength and durability.
The FT1000
Series saves
water and
energy.
The unit has the
lowest water
and energy
consumption in
the industry, yet
provides effective cleaning and sanitizing that meets
NSF International requirements.
This is achieved through
a carefully balanced ratio
of water ow to pressure.
Insulated doors and thermal
layered curtains also reduce
heat loss. The unit’s 58
gallons per hour rinse ow
rate saves both water and the
energy to heat it.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 4 of 12 F40352 – FT1000 Flight-Type Dishwasher
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
6" MINIMUM
WITH DETERGENT DISPENSER
ON THE TOP
44 13/16"
SEE NOTE (a)
FLOOR LINE
35"
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
40 3/8"
NOTE: REFER TO LATEST
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
FT1000
ELECTRIC L-R
P2
V1
P3
V1
E1
E2
E3
E4
P1
P1
P2
P3
E1
E2
E3
P3
E6E7
E8
E9
E4
E5
E9
E8
E7
E6
E5
18 3/4"
37 1/2"
55 11/16"
63 3/8"
11 13/16"
9 15/16"
23 3/4"
60"
52"
44 9/16"
160 1/16"
DIRECTION OF OPERATION
6"
36 1/2"
36 1/4"
3"
35 7/16" 35 7/16" 35 7/16"
25 9/16"
5 3/4"
23 3/4"
FLOOR LINE
43 5/16"
25 9/16"
10 3/8"
7 7/8"
OVER FRAME "A"
3 15/16"
UNLOAD "C"
62 3/4"
LOAD "B"
8' 7/16"
81 7/8"
V1
6" AIR
GAP
89 3/8"
SEE NOTE (e
)
UNLOAD
END
LOAD
END
ASR
BLOWER/
DRYER
POWER
WASH
PRE-
WASH
POWER
RINSE
AUX
RNS
FNL
RNS
HEAT
PUMP
EXHAUST HOOD
SUPPLIED BY OTHERS
IF REQUIRED
MODEL NO.
"A" "B"
"C"
NO
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
FT1023 (7.5'-8'-7.5') 23' 3-1/2"
FT1024 (8.5'-8'-7.5') 24' 3-1/4"
FT1025 (9.5'-8'-7.5') 25' 3-3/32"
FT1025 (7.5'-8'-9') 24' 11-1/4"
FT1026 (8.5'-8'-9')
25' 11"
FT1027 (9.5'-8'-9') 26' 10-27/32"
FT1027 (7.5'-8'-11') 26' 10-7/8"
FT1028 (8.5'-8'-11') 27' 10-5/8"
FT1029 (9.5'-8'-11') 28' 10-15/32"
FT1030 (7.5'-8'-15') 30' 6-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16"
FT1032 (9.5'-8'-15') 32' 5-25/32"
FT1032 (7.5'-8'-17') 32' 5-3/4"
FT1033 (8.5'-8'-17') 33' 5-1/2"
FT1034 (9.5'-8'-17') 34' 5-11/32"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F40352 – FT1000 Flight-Type Dishwasher Page 5 of 12
FT1000
ELECTRIC L-R
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS,CONTROLS,POWER RINSE & BOOSTER HEAT (TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
200 200
240/60/3
200
200
480/60/3
100 100
152.0
147.2
82.0
B/D BLOWERS, WASH TANK AUX HEAT, DUAL RINSE HEAT
& HEAT PUMP COMPRESSOR (TB2)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICE
208/60/3
109.9
150 150
240/60/3
106.3
150 150
480/60/3
52.6
70 70
SERVICE CONNECTION W/O CIRCUIT BREAKERS
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE (13KW), B/D BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
60 60
240/60/3
60 60
480/60/3
30 30
45.7
43.9
22.6
ELECTRIC TANK HEAT, POWER RINSE
(1) 26 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
208/60/3
77.8
100 100
240/60/3
74.2 100 100
480/60/3
37.06
06
0
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
64.2 80 80
240/60/3
62.4 80 80
480/60/3
30.0 40 40
HEAT PUMP COMPRESSOR & WASH TANK AUX HEAT (13 KW)
(1) CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
27.0 35 35
240/60/3
25.8 35 35
480/60/3
12.9 20 20
ELECTRIC BOOSTER
(1) 9 KW CONNECTION AS SHOWN BELOW
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
y, safety and plumbing
codes.
Drain and fill line configurations
vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
GENERAL NOTES:
(a)
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
A
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
T
AP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
ALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 40-45 PSI.
RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO
THE DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS T
CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
VENTILATION NOTES:
(e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMO
VED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
ELECTRICAL CONNECTIONS
COMMON ON
ALL MODELS:
E1
ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDER
S
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
E2 ELECTRIC CONNECTION
, VENT FAN CONTROL.
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
ELECTRIC CONNECTION, MOTORS & CONTROLS,
1" CONDUIT. 79-1/8" AFF
E4
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 26KW.
1-1/4" CONDUIT. 79-1/8" AFF
E5
ELECTRIC TANK HEAT CONNECTION, WASH TANK AUX HEAT, 13K
W.
HEAT PUMP COMPRESSOR.
1" CONDUIT. 79-1/8" AFF
E6
ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 13KW.
B
LOWER DRYER BLOWERS.
1" CONDUIT. 79-1/8" AFF
E7
ELECTRIC CONNECTION, BOOSTER, 9KW.
1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, POWER RINSE &
BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED)
.
(TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, B/D BLOWERS, WASH TANK AUX HEAT,
DUAL RINSE HEAT & HEAT PUMP COMPRESSOR (TB2).
2" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATE
R
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,
1" FPT, 5-1/2" AFF see notes (c) AND (d).
P3 COMMON DRAIN CONNECTION.
TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END
OF UNIT, PLUG OPPOSITE END.
2" FPT. 7" AFF
MODEL:
FT1000
ADVANSYS
ELECTRIC
L-R OPERATIO
N
00-949509
REV A1
VENTILATION REQUIREMENTS:
V1 IF SUPPLEMENTAL VENTILATION IS REQUIRED TO HANDLE MACHINE’S
LATENT & SENSIBLE HEAT:
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF
PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD
SUPPLIED AND INSTALLED BY OTHERS). WHEN VENT HOOD IS INSTALLED,
BACK DRAFT PREVENTER IS REQUIRED (SUPPLIED AND INSTALLED BY OT
HERS).
95-3/8" AFF
MOTORS AND CONTROLS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICE
208-240/60/3
47.2
60 60
480/60/3
32.1
40 40
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 6 of 12 F40352 – FT1000 Flight-Type Dishwasher
FT1000
ELECTRIC R-L
DIRECTION OF OPERATION
HEAT
PUMP
6"
36 1/2"
36 1/4"
3"
35 7/16"35 7/16"35 7/16"
25 9/16"
5 3/4"
23 3/4"
FLOOR LINE
43 5/16"
25 9/16"
EXHAUST HOOD
SUPPLIED BY OTHERS
IF REQUIRED
10 3/8"
7 7/8"
OVER FRAME "A"
3 15/16"
UNLOAD "C"
81 7/8"
8' 7/16"
LOAD "B"
62 3/4"
V1
UNLOAD
END
LOAD
END
ASR
BLOWER/
DRYER
POWER
WASH
PRE-
WASH
POWER
RINSE
FNL
RNS
AUX
RNS
89 3/8"
S
EE NOTE (e)
6" AIR
GAP
18 3/4"
37 1/2"
55 11/16"
63 3/8"
11 13/16"
9 15/16"
23 3/4"
60"
52"
44 9/16"
160 1/16"
P2
V1
P3
V1
E1
E2
E3
P1
P1
P2
P3
E1
E2
E3
P3
E6 E7
E8
E9
E4
E5
E5
E4
E9
E8
E7
E6
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
6" MINIMUM
WITH DETERGENT DISPENSER
ON THE TOP
FLOOR LINE
44 13/16"
SEE NOTE (a)
35"
40 3/8"
NOTE: REFER TO LATEST
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
MODEL NO.
"A" "B"
"C"
NO
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
FT1023 (7.5'-8'-7.5') 23' 3-1/2"
FT1024 (8.5'-8'-7.5') 24' 3-1/4"
FT1025 (9.5'-8'-7.5') 25' 3-3/32"
FT1025 (7.5'-8'-9') 24' 11-1/4"
FT1026 (8.5'-8'-9')
25' 11"
FT1027 (9.5'-8'-9') 26' 10-27/32"
FT1027 (7.5'-8'-11') 26' 10-7/8"
FT1028 (8.5'-8'-11') 27' 10-5/8"
FT1029 (9.5'-8'-11') 28' 10-15/32"
FT1030 (7.5'-8'-15') 30' 6-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16"
FT1032 (9.5'-8'-15') 32' 5-25/32"
FT1032 (7.5'-8'-17') 32' 5-3/4"
FT1033 (8.5'-8'-17') 33' 5-1/2"
FT1034 (9.5'-8'-17') 34' 5-11/32"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F40352 – FT1000 Flight-Type Dishwasher Page 7 of 12
FT1000
ELECTRIC R-L
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS,CONTROLS,POWER RINSE & BOOSTER HEAT (TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
200 200
240/60/3
200
200
480/60/3
100 100
152.0
147.2
82.0
B/D BLOWERS, WASH TANK AUX HEAT, DUAL RINSE HEAT
& HEAT PUMP COMPRESSOR (TB2)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICE
208/60/3
109.9
150 150
240/60/3
106.3
150 150
480/60/3
52.6
70 70
SERVICE CONNECTION W/O CIRCUIT BREAKERS
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE (13KW), B/D BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
60 60
240/60/3
60 60
480/60/3
30 30
45.7
43.9
22.6
ELECTRIC TANK HEAT, POWER RINSE
(1) 26 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
208/60/3
77.8
100 100
240/60/3
74.2 100 100
480/60/3
37.06
06
0
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
64.2 80 80
240/60/3
62.4 80 80
480/60/3
30.0 40 40
HEAT PUMP COMPRESSOR & WASH TANK AUX HEAT (13 KW)
(1) CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208/60/3
27.0 35 35
240/60/3
25.8 35 35
480/60/3
12.9 20 20
ELECTRIC BOOSTER
(1) 9 KW CONNECTION AS SHOWN BELOW
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
y, safety and plumbing
codes.
Drain and fill line configurations
vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
GENERAL NOTES:
(a)
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
A
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
T
AP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
ALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 40-45 PSI.
RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO
THE DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS T
CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
VENTILATION NOTES:
(e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMO
VED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
ELECTRICAL CONNECTIONS
COMMON ON
ALL MODELS:
E1
ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDER
S
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
E2 ELECTRIC CONNECTION
, VENT FAN CONTROL.
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
ELECTRIC CONNECTION, MOTORS & CONTROLS,
1" CONDUIT. 79-1/8" AFF
E4
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 26KW.
1-1/4" CONDUIT. 79-1/8" AFF
E5
ELECTRIC TANK HEAT CONNECTION, WASH TANK AUX HEAT, 13K
W.
HEAT PUMP COMPRESSOR.
1" CONDUIT. 79-1/8" AFF
E6
ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 13KW.
B
LOWER DRYER BLOWERS.
1" CONDUIT. 79-1/8" AFF
E7
ELECTRIC CONNECTION, BOOSTER, 9KW.
1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, POWER RINSE &
BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED)
.
(TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, B/D BLOWERS, WASH TANK AUX HEAT,
DUAL RINSE HEAT & HEAT PUMP COMPRESSOR (TB2).
2" CONDUIT, 79-1/8" AFF
MODEL:
FT1000
ADVANSYS
ELECTRIC
R-L OPERATIO
N
00-949508
REV A1
VENTILATION REQUIREMENTS:
V1 IF SUPPLEMENTAL VENTILATION IS REQUIRED TO HANDLE MACHINE’S
LATENT & SENSIBLE HEAT:
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF
PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD
SUPPLIED AND INSTALLED BY OTHERS). WHEN VENT HOOD IS INSTALLED,
BACK DRAFT PREVENTER IS REQUIRED (SUPPLIED AND INSTALLED BY OT
HERS).
95-3/8" AFF
PLUMBING CONNECTIONS:
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATE
R
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,
1" FPT, 5-1/2" AFF see notes (c) AND (d).
P3 COMMON DRAIN CONNECTION.
TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END
OF UNIT, PLUG OPPOSITE END.
2" FPT. 7" AFF
MOTORS AND CONTROLS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICE
208-240/60/3
47.2
60 60
480/60/3
32.1
40 40
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 8 of 12 F40352 – FT1000 Flight-Type Dishwasher
FT1000
STEAM L-R
18 3/4"
37 1/2"
55 11/16"
63 3/8"
11 13/16"
2 15/16"
33 3/8"
15 11/16"
9 15/16"
38 1/4"
28 15/16"
21 3/4"
55 3/16"
51 15/16"
44 9/16"
23 3/4"
160 1/16"
P1
V1
P4
P3
V1
E1
E2
E3
P5
P5
P5
P2
P1
P3
E1
E2
E3
P3
E5
E6
E4
P2 P4
E4
E7
E5
E6
E7
DIRECTION OF OPERATION
6"
36 1/2"
36 1/4"
3"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
23 3/4"
FLOOR LINE
43 5/16"
25 9/16"
10 3/8"
3 15/16"
OVER FRAME "A"
7 7/8"
UNLOAD "C"
62 3/4"
LOAD "B"
8' 7/16"
81 7/8"
V1
LOAD
END
UNLOAD
END
ASR
BLOWER/
DRYER
AUX
RNS
FNL
RNS
POWER
WASH
PRE-
WASH
POWER
RINSE
6" AIR
GAP
89 3/8"
SEE NO
TE (f)
HEAT
PUMP
EXHAUST HOOD
SUPPLIED BY OTHERS
IF REQUIRED
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
y, safety and plumbing
codes.
Drain and fill line configurations
vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
6" MINIMUM
WITH DETERGENT DISPENSER
ON THE TOP
44 13/16"
SEE NOTE (a)
FLOOR LINE
35"
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
40 3/8"
NOTE: REFER TO LATEST
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F40352 – FT1000 Flight-Type Dishwasher Page 9 of 12
GENERAL NOTES:
(a)
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
A
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
T
AP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMAT
ION
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
FT1000
STEAM L-R
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULT S.
(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 40-45 PSI.
(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO
THE
DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F
CONTACT SALES ENGINEERING.
(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
WATER SUPPLY LINES AT SERVICE CONNECTION.
(e) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE
AT THE DISHWASHER, CONTACT SALES ENGINEERING.
PLUMBING CONNECTIONS:
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,
1" FPT, 5-1/2" AFF see notes (c) AND (d).
P3 COMMON DRAIN CONNECTION.
TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END
OF UNIT, PLUG OPPOSITE END.
2" FPT. 7" AFF
P4 COMMON STEAM CONNECTION (TANK HEAT)
1-1/2" FPT, 4-3/8"
AFF (10-45 PSI FLOWING PRESSURE) see note (e).
P5 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS.
3/4" FPT, 11" AFF
VENTILATION NOTES:
(f) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
VENTILATION REQUIREMENTS:
V1 IF SUPPLEMENTAL VENTILATION IS REQUIRED TO HANDLE MACHINE’S
LATENT & SENSIBLE HEAT:
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF
PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD
SUPPLIED AND INSTALLED BY OTHERS). WHEN VENT HOOD IS INSTALLED,
BACK DRAFT PREVENTER IS REQUIRED (SUPPLIED AND INSTALLED BY OTHERS)
.
95-3/8" AFF
ELECTRICAL CONNECTIONS
COMMON ON ALL MODELS:
E1 ELECTRIC CONNECTION, DETERGENT
AND RINSE FEEDERS (MACHINE
SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS)
1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AF
F
E4
ELECTRIC CONNECTION, HEAT PUMP COMPRESSOR & WASH TANK
A
UX HEAT (13 KW), 1" CONDUIT. 79-1/8" AFF
E5
ELECTRIC CONNECTION, ELECTRIC BOOSTER, 9KW.
1" CONDUIT. 79-1/8" AFF
MODEL NO.
"A" "B"
"C"
NO
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
FT1023 (7.5'-8'-7.5') 23' 3-1/2"
FT1024 (8.5'-8'-7.5') 24' 3-1/4"
FT1025 (9.5'-8'-7.5') 25' 3-3/32"
FT1025 (7.5'-8'-9') 24' 11-1/4"
FT1026 (8.5'-8'-9')
25' 11"
FT1027 (9.5'-8'-9') 26' 10-27/32"
FT1027 (7.5'-8'-11') 26' 10-7/8"
FT1028 (8.5'-8'-11') 27' 10-5/8"
FT1029 (9.5'-8'-11') 28' 10-15/32"
FT1030 (7.5'-8'-15') 30' 6-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16"
FT1032 (9.5'-8'-15') 32' 5-25/32"
FT1032 (7.5'-8'-17') 32' 5-3/4"
FT1033 (8.5'-8'-17') 33' 5-1/2"
FT1034 (9.5'-8'-17') 34' 5-11/32"
MODEL:
FT1000
ADVANSY
S
STEAM
L-R OPER
ATION
00-949509
REV A1
ELECTRICAL CONNECTIONS
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, 1-1/4" CONDUIT.
79-1/8" AFF
E9 ELECTRIC CONNECTION, HEAT PUMP COMPRESSOR & WASH TANK AUX
HEAT (13 KW), & ELECTRIC BOOSTER (9 KW), 1" CONDUIT, 79-1/8" AFF
SERVICE CONNECTION W/O CIRCUIT BREAKERS
(3) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS AND CONTROLS
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
70 70
480/60/3
45 45
54.5
36.4
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
64.2 80 80
480/60/3
30.0 40 40
HEAT PUMP COMPRESSOR & WASH TANK AUX HEAT (13 KW)
(1) CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
25.8
35 35
480/60/3
12.9 20 20
ELECTRIC BOOSTER
(1) 9 KW CONNECTION AS SHOWN BELOW
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS & CONTROLS
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
70 70
480/60/3
45
45
54.5
36.4
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
91.2 125 125
480/60/3
42.9 60 60
HEAT PUMP COMPRESSOR, WASH TANK AUX HEAT (13 KW)
& ELECTRIC BOOSTER (9 KW)
(1) CONNECTION AS SHOWN BELOW
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 10 of 12 F40352 – FT1000 Flight-Type Dishwasher
FT1000
STEAM R-L
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
y, safety and plumbing
codes.
Drain and fill line configurations
vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
18 3/4"
37 1/2"
55 11/16"
63 3/8"
11 13/16"
15 11/16"
9 15/16"
38 1/4"
28 15/16"
23 3/4"
60"
52"
44 9/16"
160 1/16"
22 5/8"
53 3/8"
P4
P2
V1
P3
V1
P5
P1
P1
P2
P3
E1
E2
E3
P4
P3
E4
E3
E2
E1
E4
P5
P5
E5
E6
E7
E5
E6
E7
DIRECTION OF OPERATION
6"
36 1/2"
36 1/4"
3"
35 7/16"35 7/16"35 7/16"
25 9/16"
5 3/4"
23 3/4"
FLOOR LINE
43 5/16"
25 9/16"
10 3/8"
7 7/8"
OVER FRAME "A"
3 15/16"
UNLOAD "C"
81 7/8"
8' 7/16"
LOAD "B"
62 3/4"
V1
UNLOAD
END
LOAD
END
6" AIR
GAP
ASR
BLOWER/
DRYER
POWER
WASH
PRE-
WASH
POWER
RINSE
AUX
RNS
FNL
RNS
HEAT
PUMP
EXHAUST HOOD
SUPPLIED BY OTHERS
IF REQUIRED
89 3/8"
SEE NO
TE (f)
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
6" MINIMUM
WITH DETERGENT DISPENSER
ON THE TOP
FLOOR LINE
44 13/16"
SEE NOTE (a)
35"
40 3/8"
NOTE: REFER TO LATEST
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F40352 – FT1000 Flight-Type Dishwasher Page 11 of 12
FT1000
STEAM R-L
GENERAL NOTES:
(a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMAT
ION
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULT S.
(b) RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 40-45 PSI.
(c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO
THE
DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F
CONTACT SALES ENGINEERING.
(d) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
WATER SUPPLY LINES AT SERVICE CONNECTION.
(e) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE
AT THE DISHWASHER, CONTACT SALES ENGINEERING.
VENTILATION NOTES:
(f) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
VENTILATION REQUIREMENTS:
V1
IF SUPPLEMENTAL VENTILATION IS REQUIRED TO HANDLE MACHINE’S
LATENT & SENSIBLE HEAT:
M
INIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF
PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD
S
UPPLIED AND INSTALLED BY OTHERS). WHEN VENT HOOD IS INSTALLED,
BACK DRAFT PREVENTER IS REQUIRED (SUPPLIED AND INSTALLED BY OTHERS)
.
95-3/8" AFF
ELECTRICAL CONNECTIONS
COMMON ON ALL MODELS:
E1 ELECTRIC CONNECTION, DETERGENT
AND RINSE FEEDERS (MACHINE
SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS)
1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AF
F
E4
ELECTRIC CONNECTION, HEAT PUMP COMPRESSOR & WASH TANK
A
UX HEAT (13 KW), 1" CONDUIT. 79-1/8" AFF
E5
ELECTRIC CONNECTION, ELECTRIC BOOSTER, 9KW.
1" CONDUIT. 79-1/8" AFF
MODEL NO.
"A" "B"
"C"
NO
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
7' 8-1/2"
8' 8-1/4"
9' 8-3/32"
FT1023 (7.5'-8'-7.5') 23' 3-1/2"
FT1024 (8.5'-8'-7.5') 24' 3-1/4"
FT1025 (9.5'-8'-7.5') 25' 3-3/32"
FT1025 (7.5'-8'-9') 24' 11-1/4"
FT1026 (8.5'-8'-9')
25' 11"
FT1027 (9.5'-8'-9') 26' 10-27/32"
FT1027 (7.5'-8'-11') 26' 10-7/8"
FT1028 (8.5'-8'-11') 27' 10-5/8"
FT1029 (9.5'-8'-11') 28' 10-15/32"
FT1030 (7.5'-8'-15') 30' 6-3/16"
FT1031 (8.5'-8'-15') 31' 5-15/16"
FT1032 (9.5'-8'-15') 32' 5-25/32"
FT1032 (7.5'-8'-17') 32' 5-3/4"
FT1033 (8.5'-8'-17') 33' 5-1/2"
FT1034 (9.5'-8'-17') 34' 5-11/32"
MODEL:
FT1000
ADVANSY
S
STEAM
R-L OPER
ATION
00-949508
REV A1
ELECTRICAL CONNECTIONS
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, 1-1/4" CONDUIT.
79-1/8" AFF
E9 ELECTRIC CONNECTION, HEAT PUMP COMPRESSOR & WASH TANK AUX
HEAT (13 KW), & ELECTRIC BOOSTER (9 KW), 1" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM,
1" FPT, 5-1/2" AFF see notes (c) AND (d).
P3 COMMON DRAIN CONNECTION.
TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END
OF UNIT, PLUG OPPOSITE END.
2" FPT. 7" AFF
P4 COMMON STEAM CONNECTION (TANK HEAT)
1-1/2" FPT, 4-3/8"
AFF (10-45 PSI FLOWING PRESSURE) see note (e).
P5 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS.
3/4" FPT, 11" AFF
SERVICE CONNECTION W/O CIRCUIT BREAKERS
(3) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS AND CONTROLS
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
70 70
480/60/3
45 45
54.5
36.4
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
64.2 80 80
480/60/3
30.0 40 40
HEAT PUMP COMPRESSOR & WASH TANK AUX HEAT (13 KW)
(1) CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
25.8
35 35
480/60/3
12.9 20 20
ELECTRIC BOOSTER
(1) 9 KW CONNECTION AS SHOWN BELOW
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS & CONTROLS
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
70 70
480/60/3
45
45
54.5
36.4
ELEC.
SPECS.
RATED
AMPS
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
208-240/60/3
91.2 125 125
480/60/3
42.9 60 60
HEAT PUMP COMPRESSOR, WASH TANK AUX HEAT (13 KW)
& ELECTRIC BOOSTER (9 KW)
(1) CONNECTION AS SHOWN BELOW
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 12 of 12 F40352 – FT1000 Flight-Type Dishwasher
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
FT1000
FLIGHT-TYPE DISHWASHER
FT1000 Series
(7.5, 9 Load / 8 Center / 7.5, 9, 11 Unload)
Machine Ratings (Mechanical)
Conveyor Speed — Feet per minute 4.0 - 8.5
Dishes per Hour 14,316
Motor — Horsepower ASR Soil -
1
4; ASR Wash -
1
3; Pre-Wash - 3
1
2; Wash - 5; Rinse - 5;
Dual Rinse -
1
6; Final Rinse -
1
2; Conveyor -
1
3; Blower Dryer - (2) 2
Tank Capacity — Gallons ASR - 7.2; Pre-Wash - 40; Wash - 40; Rinse - 40; Dual Rinse - 7.2
Rate of Final Rinse — Gallons per minute
(Pumped rinse) .97
Final Rinse Consumption — Gallons per hour
(Pumped rinse) 58
Exhaust Requirements — Cubic feet per minute
(if supplemental ventilation is required to handle
machine’s latent and sensible heat)
750
(at standard air conditions)
Latent/Sensible Heat — BTU per hour Electric - Latent: 108,300 / Sensible: 46,400
Steam - Latent: 132,100 / Sensible: 56,600
Electric Heat Requirements
Tank Heat - Kilowatt (Regulated)
Electric Booster - Kilowatt
Disconnect switches are recommended for each power circuit connected
to dishwasher. These disconnect switches are NOT furnished by Hobart
and should be installed by the electrical contractor at the time of installation.
Circuit breakers optional at extra cost.
Total tank heat - 43KW (Wash, Rinse, Dual Rinse)
9KW - 150°F incoming water raised to 185°F (35°F rise) (180°F minimum)
Blower Dryer Heat Pump Technology
Steam Heat Requirements
Steam Consumption
Tank Heat - Pounds per hour - maximum
(Regulated) - based on 10 to 45 PSI steam at
the machine
179 lbs./150°F Wash minimum - 160°F Rinse minimum -
160°F Dual Rinse minimum
Peak Rate of Drain Flow — Gallons per minute
Initial rate with full tanks 38
Shipping Weight Crated Varies by individual model - consult your Hobart representative
FT (ight type) Models—many additional variations of
these model specications are available. Engineering
data furnished on request. Numbers in parentheses,
after model number from left to right, represent length
in feet of the following respectively; Loading section,
Washing and Power Rinsing sections, Unloading
section.
F40352 (REV. 02/15) LITHO IN U.S.A. (H-01)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Hobart FT1000 User manual

Type
User manual
This manual is also suitable for

Hobart Dishwasher FT1000 is a flight-type dishwasher that uses a pumped rinse system and has a water usage of 58 gph. It has digital controls with machine diagnostics, a low temperature alert, and a single point vent location. The machine has 31" access on prewash, power wash and power rinse chambers; 20" access on dual rinse and ASR chambers. It also has start and stop switches at both ends, doors open indicator, drains open indicator, and door interlocks. The FT1000 comes with 31⁄2 H.P. prewash, 5 H.P. power wash and power rinse pump motors, all TEFC, and capless Auto Clean wash arms.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI