Machine Electrical Specifications
Total Machine Current Draw: 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph
Electric tank heat, 40°F/22°C rise booster 227.5 A 205.0 A 99.4 A
Electric tank heat, 70°F/39°C rise booster 267.5 A 242.0 A 117.9 A
Electric tank heat, opt. waste air heat recovery (130°F/72°C rise) 267.5 A 242.0 A 117.9 A
Steam tank heat/steam booster 40.5 A 39.5 A 17.9 A
Single blower dryer (electric) Add 26.5 A Add 23.3 A Add 12.3 A
Single blower dryer (steam) Add 1.6 A Add 1.4 A Add 0.9 A
Dual blower dryer (electric) Add 28.0 A Add 24.6 A Add 13.1 A
Dual blower dryer (steam) Add 3.1 A Add 2.7 A Add 1.7 A
CSS Top Add 3.9 A Add 3.9 A Add 2.3 A
Water Specifications
Minimum water temperatures:
Prewash tank .................................................. 110°F (43°C)
Wash tank 1 ................................................... 150°F (66°C)
Wash tank 2 ................................................... 150°F (66°C)
Recirculating rinse tank .................................. 160°F (72°C)
Auxiliary rinse ................................................. 165°F (77°C)
Final rinse ....................................................... 180°F (82°C)
Water requirements:
Recommended fill temp ..................... 110-140°F (43-60°C)
Minimum incoming water temperature:
For 40°F/22°C minimum rise ...................... 140°F (60°C)
For 70°F/39°C minimum rise ...................... 110°F (43°C)
For 130°F/72°C minimum rise * ................... 50°F (10°C)
* Requires waste air heat recovery option.
Initial fill ............................................... 141 U.S. gals. (534
l)
Consumption at 100% cap. ........... 137 U.S. gals. (519
l)/hr.
Minimum incoming water line size:
Initial fill line (units with waste heat
recovery option) or single water
connection (all other units) ....................................... 3/4” NPT
Final rinse line (units with waste heat
recovery option only) ................................................ 1/2” NPT
Minimum final rinse flow rate .................... 2.4 U.S. gals.(9.1
l)/min.
Recommended max. water hardness ............ 4 grains/U.S. gal.
Drain ................................................ 3” IPS drain pipe; indirect
connection to 4” (102mm)
floor drain recommended
Tank capacities:
Prewash tank ........................................... 29 U.S. gals. (110l )
Wash tank 1 ............................................. 31 U.S. gals. (117l )
Wash tank 2 ............................................. 33 U.S. gals. (125l)
Recirculating rinse tank ........................... 33 U.S. gals. (125l)
Auxiliary rinse tank ..................................... 16 U.S. gals. (60l)
Venting Specifications
Venting requirements (standard) ............... 824 CFM (1400m
3
h)
Venting requirements (with blower dryer) 1060 CFM (1800m
3
h)
Room air to cool exhaust (recommended) ...... 120 CFM (202m
3
/h)
Waste air temp. (approx.) .................................. 122°F (50°C)
Waste air temp. (with optional waste
air heat recovery option, approx.) ....................... 95°F (35°C)
Operating Capacities (NSF Rated)
Dishes per hour (maximum) ........................................ 15,840
Consumption ..................................... 137 U.S. gals. (519
l)/hr.
Conveyor Specifications
Conveyor belt speed:
Minimum ........................................................ 8’ (2.4m)/min.
Maximum ..................................................... 12’ (3.7m)/min.
Horizontal clearance ................................. 1’ 11-3/8” (600mm)
Vertical clearance .......................................1’ 3-3/4” (400mm)
Conveyor belt minimum peg spacing .............. 2-1/8” (55mm)
B-US 233 LPW Technical Specifications
Component Electrical Specifications
Prewash pump motor ...................... 3 hp
Wash pump motors ................... 2 x 3 hp
Recirculating rinse pump motor ...... 3 hp
Auxiliary rinse pump motor......... 0.75 hp
Final rinse pump motor .............. 0.75 hp
Conveyor motor / min spd ......... 0.17 hp
Conveyor motor / max speed ..... 0.25 hp
Vent motor .................................. 0.21 hp
CSS Top pump motor ...................... 1 hp
Blower dryer motors (1x for single blower
dryer, 2x for dual blower dryers):
• Electric or steam heat,
208 V or 240 V .......................... 0.5 hp
• Electric or steam heat,
460 V ......................................... 0.6 hp
Motors:
Electric Heating Elements (electrically-
heated units only):
Wash tanks ............................. 2 x 12 kW
Recirculating rinse tank ............... 18 kW
Auxiliary rinse tank ......................... 9 kW
Booster heater / 40°F rise ........... 15 kW
Booster heater / 70°F rise ........... 30 kW
Booster heater / Waste heat
recovery option, 130°F rise ......... 30 kW
Blower dryer heater (single
or dual blower dryers ) ............. 1 x 9 kW
Steam Specifications (steam-heated units only)
Steam line connection ........................................... 1-1/2” NPT
Condensate return connection .................................... 1” NPT
Recommended steam pressure .............. 15-30 psi (1-2 bars)
Consumption
Incoming water temp. 110°F/43°C........... 307 lbs./hr. (81 kW)
Incoming water temp. 140°F/60°C .......... 250 lbs./hr. (66 kW)
Incoming water temp. 50°F/10°C (with
optional waste air heat recovery sys.) ..... 307 lbs./hr. (81 kW)
Optional steam blower dryer ................ Add 34 lbs./hr. (9 kW)