Meiko B-US232, B-US231, B-US233 Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Meiko B-US232 Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
B-US 231/232/233
SERIES
HOT WATER
SANITIZING
FLIGHT-TYPE
WAREWASHERS
Meiko's flight-type conveyors are the ideal choice for high-volume applications. They feature dramatically improved water savings
and Meiko’s exclusive Chemical Savings System (CSS) that reduces detergent consumption from 30-50 percent. As with all products
synonymous with the name “Meiko,” engineering excellence, manufacturing quality and performance come to the forefront in the
B-US 23 Series flight machines.
Model B-US 231 includes: wash section, pumped auxiliary rinse zone, pumped fresh water final rinse.
Model B-US 231 PW includes: prewash section, wash section, pumped auxiliary rinse zone, pumped fresh water final rinse.
Model B-US 231 LPW includes: large prewash section, wash section, pumped auxiliary rinse zone, pumped fresh water final rinse.
Model B-US 232 LPW includes: large prewash section, wash section, recirculating rinse section, pumped auxiliary rinse zone,
pumped fresh water final rinse.
Model B-US 233 LPW includes: large prewash section, two wash sections, recirculating rinse section, pumped auxiliary rinse
zone, pumped fresh water final rinse.
Exclusive Features:
Optional Waste Air Heat Recovery System utilizes heat
generated by the machine to heat the incoming fresh water.
This utilizes “free” energy and allows the machine to use an
incoming water supply with temperatures as low as 50°F.
Insulated double-wall construction on doors, front, top
and back
Pumped auxiliary rinse supplements the pumped fresh
water final rinse
Standard Chemical Savings System (CSS) Basic reduces
detergent consumption by 30% (based on Meiko’s low water
consumption)
Optional CSS Top reduces detergent consumption by 50%
Standard Features:
Low NSF-rated water consumption
High capacity
Built-in booster heater (steam or electric)
Central control panel with simple electro-mechanical controls
Operator-activated start/stop controls at both ends of machine
Two-speed conveyor
Stainless steel wash pump assemblies with vertically-
mounted, self-draining pumps and powerful 3 hp motors
V-shaped wash tanks for faster draining and easier cleaning
Block-manifold wash arms for fast removal and easier cleaning
Tethered or “captivated” wash arm end caps
Slotted, concave, non-clogging wash arm nozzles
Large, balanced front access doors stay open without latching
Contacts for external fan control and external transport control
Options:
Waste Air Heat Recovery System
Single blower dryer (steam or electric)
Dual blower dryer (steam or electric)
CSS Top
Load and unload ends in various lengths
Steam or electric tank/booster heat
Factory-installed external fan controller
B-US 23 Series • Updated 11-04 Meiko • 917 Airpark Center Drive • Nashville, TN 37217 • (800) 55-MEIKO • FAX (615) 399-6620 • www.meiko.us
1' 10-1/8"
(562mm)
door
opening
6' 4-3/4"
(1950mm)
2' 11-3/8"
(900mm)
4' 6-5/8"
(1388mm)
2' 6-1/2"
(775mm)
L1
load section length
Start/stop
controls
6-1/2"
(165mm)
4' 3-1/8" (1300mm)
U1
unload section length
Wash pump
3.0 hp
Final rinse
pump 0.75 hp
Aux. rinse
pump 0.75 hp
Control
panel
Fill vacuum
breaker
Start/stop
controls
6' 2-3/4"
(1900mm)
1' 3-3/4" (400mm)
passing height
1' 11-3/8"
(600mm)
horizontal
clearance
4-7/8"
(125mm)
1' 3-3/8"
(390mm)
2' 6-3/4"
(780mm)
3/4"
(20mm)
3-7/8"
(100mm)
1' 3-3/8"
(390mm)
8-1/4"
(210mm)
8-5/8"
(220mm)
7-7/8"
(200mm)
2' 3/4"
(630mm)
2' 11-3/8"
(900mm)
D
Front
PLAN
VIEW
ELEVATION VIEW
(FRONT)
ELEVATION VIEW (RIGHT)
STANDARD
Load section length (L1) Clear load area (L2)
2' 11-3/8" (900mm) † 1' 11-5/8" (600mm) †
3' 7-1/4" (1100mm) 2' 7-1/2" (800mm)
4' 7-1/8" (1400mm) 3' 7-1/4" (1100mm)
7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
7' 10-1/2" (2400mm)* 6' 10-5/8" (2100mm)*
LOAD SECTIONS
STANDARD
Unl (U1) Clear unload (U2)oad section
6' 2-3/4" (1900mm) † 3' 5-3/8" (1050mm) †
7' 6-1/2" (2300mm) 4' 9-1/8" (1450mm)
8' 6-3/8" (2600mm) 5' 8-7/8" (1750mm)
9' 10-1/8" (3000mm) 7' 5/8" (2150mm)
10' 9-7/8" (3300mm) 8' 1/2" (2450mm)
13' 1-1/2" (4000mm) 10' 4" (3150mm)
16' 7/8" (4900mm) 14' 9-1/8" (4500mm)
UNLOAD SECTIONS
SINGLE BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
3' 7-1/4" (1100mm)-long drying tunnel:
4' 11" (1500mm)-long drying tunnel:
6' 2-3/4" (1900mm)-long drying tunnel:
6' 2-3/4" (1900mm) 2' 7-1/2" (800mm)
7' 6-1/2" (2300mm) † 3' 11-1/4" (1200mm) †
8' 6-3/8" (2600mm) 4' 11" (1500mm)
9' 10-1/8" (3000mm) 6' 2-3/4" (1900mm)
10' 9-7/8" (3300mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) 9' 6-1/8" (2900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
7' 6-1/2" (2300mm) 2' 7-1/2" (800mm)
8' 6-3/8" (2600mm) † 3' 7-1/4" (1100mm) †
9' 10-1/8" (3000mm) 4' 11" (1500mm)
10' 9-7/8" (3300mm) 5' 10-7/8" (1800mm)
13' 1-1/2" (4000mm) 8' 2-1/2" (2500mm)
16' 7/8" (4900mm) 11' 1-7/8" (3400mm)
9' 10-1/8" (3000mm) † 3' 7-1/4" (1100mm) †
10' 9-7/8" (3300mm) 4' 7-1/8" (1400mm)
13' 1-1/2" (4000mm) 6' 10-5/8" (2100mm)
16' 7/8" (4900mm) 9' 10-1/8" (3000mm)
DUAL BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
6' 7/8" (1850mm)-long drying tunnel:
7' 6-1/2" (2300mm)-long drying tunnel:
8' 10-3/8" (2700mm)-long drying tunnel:
10' 2" (3100mm)-long drying tunnel:
9' 10-1/8" (3000mm) 3' 9-1/4" (1150mm)
10' 9-7/8" (3300mm) † 4' 11" (1500mm) †
13' 1-1/2" (4000mm) 6' 2-3/4" (1900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
10' 9-7/8" (3300mm) † 3' 3-3/8" (1000mm) †
13' 1-1/2" (4000mm) 5' 6-7/8" (1700mm)
16' 7/8" (4900mm) 8' 6-3/8" (2600mm)
13' 1-1/2" (4000mm) † 4' 3-1/8" (1300mm) †
16' 7/8" (4900mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) † 2' 11-3/8" (900mm) †
16' 7/8" (4900mm) 5' 10-7/8" (1800mm)
B-US 231
Recommended location
for indirect floor drain
5-3/8"
(135mm)
2' 6-1/8"
(765mm)
2' 11-3/8"
(900mm)
Direction
of conveyor
belt travel
2' 5-1/8"
(740mm)
3' 4-1/8"
(1020mm)
1-5/8"
(40mm)
9-1/2"
(240mm)
2' 2-3/4"
(680mm)
8-7/8"
(225mm)
2' 2-3/4" (680mm)
2' 2-3/4" (680mm)
3' 7-1/4" (1100mm)
3' 7-1/4" (1100mm)
2' 9-1/8"
(840mm)
H
S
CR
11-7/8"
(300mm)
1' 6-7/8"
(480mm)
1' 11-1/4"
(590mm)
C
8-5/8"
(220mm)
3-7/8"
(100mm)
2' 3-1/2"
(700mm)
2' 3-1/2"
(700mm)
U2
clear unload area
6' 6-3/4"
(2000mm)
L2
clear load area
3-7/8"
(100mm)
Drain
3" (76mm) IPS drain. 4" indirect floor drain recommended.
D
Water connection(s)
3/4" NPT. on units that equipped with
optional waste air heat recovery system. Used as single water
connection on all other units.
1/2" NPT. on units equipped with optional
waste air heat recovery system. Not present on other units.
Used only for initial fill
Used only for final rinse
H
Steam connection
Units with steam tank/booster heat only. 1-1/2" NPT.
S
Condensate return connection
Units with steam tank/booster heat only. 1" NPT.
CR
Vent connection
See exhaust vent detail view.
Electrical connection
Units with steam heat: Single terminal block at the location shown.
Units with electric heat: 4 (four) individual terminal blocks, approx.
2-1/2" (64mm) apart, centered on the location shown.
Leads must be appropriate for electrical supply. Maximum wire
gauge #2 AWG. All connection points to be drilled during installation.
C
UTILITY CONNECTIONS
SUPPLIED BY
CUSTOMER:
Vent shroud to be
constructed with 1"
(25mm) trough to
collect condensation,
which can be
drained into machine
SUPPLIED WITH
MACHINE:
Exhaust vent
VENT
DETAIL
VIEW
1' 7-5/8" (500mm) dia.
1' 5-3/4" (450mm) dia.
1' 3-3/4"
(400mm) dia.
Gap permits
room air to
enter vent
shroud
Condensation
can be drained
into machine
(drain supplied
by customer)
Condensation
trough
Vent shroud
(supplied by
customer)
3-1/8"
(80mm)
3-7/8"
(100mm)
* With optional 2' 6-3/8" (770mm) loading height
Recommended standard element. Consult
Meiko for special ware considerations.
Recommended standard element.
Consult Meiko for special ware
considerations.
Left-to-Right machine shown.
Right-to-Left
machine is a
mirror
image.
All
dimensions from floor are
+/-
1/2" due to adjustable feet.
Left-to-Right machine shown.
Right-to-Left machine is a
mirror image.
All dimensions from floor are
+/- 1/2" due to adjustable feet.
B-US 231 Technical Specifications
Machine Electrical Specifications
Total Machine Current Draw: 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph
Electric tank heat, 40°F/22°C rise booster 149.0 A 134.6 A 66.1 A
Electric tank heat, 70°F/39°C rise booster 174.0 A 157.1 A 77.1 A
Electric tank heat, opt. waste air heat recovery (130°F/72°C rise) 174.0 A 157.1 A 77.1 A
Steam tank heat/steam booster 15.0 A 14.6 A 7.1 A
Single blower dryer (electric) Add 26.5 A Add 23.3 A Add 12.3 A
Single blower dryer (steam) Add 1.6 A Add 1.4 A Add 0.9 A
Dual blower dryer (electric) Add 28.0 A Add 24.6 A Add 13.1 A
Dual blower dryer (steam) Add 3.1 A Add 2.7 A Add 1.7 A
Water Specifications
Minimum water temperatures:
Wash tank....................................................... 160°F (72°C)
Auxiliary rinse ................................................. 165°F (77°C)
Final rinse ....................................................... 180°F (82°C)
Water requirements:
Recommended fill temp ..................... 110-140°F (43-60°C)
Minimum incoming water temperature:
For 40°F/22°C minimum rise ...................... 140°F (60°C)
For 70°F/39°C minimum rise ...................... 110°F (43°C)
For 130°F/72°C minimum rise * ................... 50°F (10°C)
* Requires waste air heat recovery option.
Initial fill ................................................. 45 U.S. gals. (250l)
Consumption at 100% cap. ........... 100 U.S. gals. (379
l)/hr.
Minimum incoming water line size:
Initial fill line (units with waste heat
recovery option) or single water
connection (all other units) ....................................... 3/4” NPT
Final rinse line (units with waste heat
recovery option only) ................................................ 1/2” NPT
Minimum final rinse flow rate .................... 1.8 U.S. gals.(6.8l)/min.
Recommended max. water hardness ............ 4 grains/U.S. gal.
Drain ................................................ 3” IPS drain pipe; indirect
connection to 4” (102mm)
floor drain recommended
Tank capacities:
Wash tank ................................................ 31 U.S. gals. (117l)
Auxiliary rinse tank ..................................... 16 U.S. gals. (60
l)
Venting Specifications
Venting requirements (standard) ................ 471 CFM (800m
3
/h)
Venting requirements (with blower dryer) . 706 CFM (1200m
3
/h)
Room air to cool exhaust (recommended) ...... 120 CFM (202m
3
/h)
Waste air temp. (approx.) .................................. 122°F (50°C)
Waste air temp. (with optional waste
air heat recovery option, approx.) ....................... 95°F (35°C)
Operating Capacities (NSF Rated)
Dishes per hour (maximum) ...........................................7,920
Consumption ..................................... 100 U.S. gals. (379
l)/hr.
Conveyor Specifications
Conveyor belt speed:
Minimum ........................................................ 4’ (1.2m)/min.
Maximum ....................................................... 6’ (1.8m)/min.
Horizontal clearance ................................. 1’ 11-3/8” (600mm)
Vertical clearance .......................................1’ 3-3/4” (400mm)
Conveyor belt minimum peg spacing .............. 2-1/8” (55mm)
Component Electrical Specifications
Wash pump motor ........................... 3 hp
Auxiliary rinse pump motor......... 0.75 hp
Final rinse pump motor .............. 0.75 hp
Conveyor motor / min spd ......... 0.17 hp
Conveyor motor / max speed ..... 0.25 hp
Vent motor .................................. 0.21 hp
Blower dryer motors (1x for single blower
dryer, 2x for dual blower dryers):
Electric or steam heat,
208 V or 240 V .......................... 0.5 hp
Electric or steam heat,
460 V ......................................... 0.6 hp
Motors:
Electric Heating Elements (electrically-
heated units only):
Wash tank .................................... 27 kW
Auxiliary rinse tank ......................... 9 kW
Booster heater / 40°F rise ........... 12 kW
Booster heater / 70°F rise ........... 21 kW
Booster heater / Waste heat
recovery option, 130°F rise ......... 21 kW
Blower dryer heater (single
or dual blower dryers ) ............. 1 x 9 kW
Steam Specifications (steam-heated units only)
Steam line connection ........................................... 1-1/2” NPT
Condensate return connection .................................... 1” NPT
Recommended steam pressure .............. 15-30 psi (1-2 bars)
Consumption
Incoming water temp. 110°F/43°C........... 216 lbs./hr. (57 kW)
Incoming water temp. 140°F/60°C .......... 182 lbs./hr. (48 kW)
Incoming water temp. 50°F/10°C (with
optional waste air heat recovery sys.) ..... 216 lbs./hr. (57 kW)
Optional steam blower dryer ................ Add 34 lbs./hr. (9 kW)
6' 4-3/4"
(1950mm)
L1
load section length
Start/stop
controls
6-1/2"
(165mm)
4' 3-1/8" (1300mm)
6' 2-3/4" (1900mm)
1' 11-5/8"
(600mm)
U1
unload section length
Wash pump
3.0 hp
Final rinse
pump 0.75 hp
Aux. rinse
pump 0.75 hp
Prewash pump
1.0 hp
Control
panel
Fill vacuum
breaker
Start/stop
controls
6' 2-3/4"
(1900mm)
4-7/8"
(125mm)
1' 3-3/8"
(390mm)
2' 6-3/4"
(780mm)
3/4"
(20mm)
3-7/8"
(100mm)
1' 3-3/8"
(390mm)
8-1/4"
(210mm)
8-5/8"
(220mm)
7-7/8"
(200mm)
2' 3/4"
(630mm)
2' 11-3/8"
(900mm)
D
Front
PLAN
VIEW
ELEVATION VIEW
(FRONT)
STANDARD CSS BASIC
Load section length (L1) Clear load area (L2)
2' 11-3/8" (900mm) † 1' 11-5/8" (600mm) †
3' 7-1/4" (1100mm) 2' 7-1/2" (800mm)
4' 7-1/8" (1400mm) 3' 7-1/4" (1100mm)
7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
7' 10-1/2" (2400mm)* 6' 10-5/8" (2100mm)*
LOAD SECTIONS
STANDARD
Unl (U1) Clear unload (U2)oad section
6' 2-3/4" (1900mm) 3' 5-3/8" (1050mm)
7' 6-1/2" (2300mm) † 4' 9-1/8" (1450mm) †
8' 6-3/8" (2600mm) 5' 8-7/8" (1750mm)
9' 10-1/8" (3000mm) 7' 5/8" (2150mm)
10' 9-7/8" (3300mm) 8' 1/2" (2450mm)
13' 1-1/2" (4000mm) 10' 4" (3150mm)
16' 7/8" (4900mm) 14' 9-1/8" (4500mm)
UNLOAD SECTIONS
SINGLE BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
3' 7-1/4" (1100mm)-long drying tunnel:
4' 11" (1500mm)-long drying tunnel:
6' 2-3/4" (1900mm)-long drying tunnel:
7' 6-1/2" (2300mm) 3' 11-1/4" (1200mm)
8' 6-3/8" (2600mm) † 4' 11" (1500mm) †
9' 10-1/8" (3000mm) 6' 2-3/4" (1900mm)
10' 9-7/8" (3300mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) 9' 6-1/8" (2900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
7' 6-1/2" (2300mm) 2' 7-1/2" (800mm)
8' 6-3/8" (2600mm) † 3' 7-1/4" (1100mm) †
9' 10-1/8" (3000mm) 4' 11" (1500mm)
10' 9-7/8" (3300mm) 5' 10-7/8" (1800mm)
13' 1-1/2" (4000mm) 8' 2-1/2" (2500mm)
16' 7/8" (4900mm) 11' 1-7/8" (3400mm)
9' 10-1/8" (3000mm) † 3' 7-1/4" (1100mm) †
10' 9-7/8" (3300mm) 4' 7-1/8" (1400mm)
13' 1-1/2" (4000mm) 6' 10-5/8" (2100mm)
16' 7/8" (4900mm) 9' 10-1/8" (3000mm)
DUAL BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
6' 7/8" (1850mm)-long drying tunnel:
7' 6-1/2" (2300mm)-long drying tunnel:
8' 10-3/8" (2700mm)-long drying tunnel:
10' 2" (3100mm)-long drying tunnel:
9' 10-1/8" (3000mm) † 3' 9-1/4" (1150mm) †
10' 9-7/8" (3300mm) 4' 11" (1500mm)
13' 1-1/2" (4000mm) 6' 2-3/4" (1900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
10' 9-7/8" (3300mm) † 3' 3-3/8" (1000mm) †
13' 1-1/2" (4000mm) 5' 6-7/8" (1700mm)
16' 7/8" (4900mm) 8' 6-3/8" (2600mm)
13' 1-1/2" (4000mm) † 4' 3-1/8" (1300mm) †
16' 7/8" (4900mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) † 2' 11-3/8" (900mm) †
16' 7/8" (4900mm) 5' 10-7/8" (1800mm)
B-US 231 PW
Recommended location
for indirect floor drain
5-3/8"
(135mm)
2' 6-1/8"
(765mm)
2' 11-3/8"
(900mm)
1' 3-3/4" (400mm)
passing height
1' 11-3/8"
(600mm)
horizontal
clearance
ELEVATION VIEW (RIGHT)
Direction
of conveyor
belt travel
2' 5-1/8"
(740mm)
3' 4-1/8"
(1020mm)
1-5/8"
(40mm)
9-1/2"
(240mm)
2' 2-3/4"
(680mm)
8-7/8"
(225mm)
2' 2-3/4" (680mm)
2' 2-3/4" (680mm)
3' 7-1/4" (1100mm)
3' 7-1/4" (1100mm)
2' 9-1/8"
(840mm)
H
S
CR
11-7/8"
(300mm)
1' 6-7/8"
(480mm)
1' 11-1/4"
(590mm)
C
8-5/8"
(220mm)
3-7/8"
(100mm)
2' 3-1/2"
(700mm)
2' 3-1/2"
(700mm)
U2
clear unload area
6' 6-3/4"
(2000mm)
L2
clear load area
Drain
3" (76mm) IPS drain. 4" indirect floor drain recommended.
D
Water connection(s)
3/4" NPT. on units that equipped with
optional waste air heat recovery system. Used as single water
connection on all other units.
1/2" NPT. on units equipped with optional
waste air heat recovery system. Not present on other units.
Used only for initial fill
Used only for final rinse
H
Steam connection
Units with steam tank/booster heat only. 1-1/2" NPT.
S
Condensate return connection
Units with steam tank/booster heat only. 1" NPT.
CR
Vent connection
See exhaust vent detail view.
Electrical connection
Units with steam heat: Single terminal block at the location shown.
Units with electric heat: 4 (four) individual terminal blocks, approx.
2-1/2" (64mm) apart, centered on the location shown.
Leads must be appropriate for electrical supply. Maximum wire
gauge #2 AWG. All connection points to be drilled during installation.
C
UTILITY CONNECTIONS
SUPPLIED BY
CUSTOMER:
Vent shroud to be
constructed with 1"
(25mm) trough to
collect condensation,
which can be
drained into machine
SUPPLIED WITH
MACHINE:
Exhaust vent
VENT
DETAIL
VIEW
1' 7-5/8" (500mm) dia.
1' 5-3/4" (450mm) dia.
1' 3-3/4"
(400mm) dia.
Gap permits
room air to
enter vent
shroud
Condensation
can be drained
into machine
(drain supplied
by customer)
Condensation
trough
Vent shroud
(supplied by
customer)
3-1/8"
(80mm)
3-7/8"
(100mm)
* With optional 2' 6-3/8" (770mm) loading height
Recommended standard element. Consult
Meiko for special ware considerations.
Recommended standard element.
Consult Meiko for special ware
considerations.
3-7/8"
(100mm)
Left-to-Right machine shown.
Right-to-Left
machine is a
mirror
image.
All
dimensions from floor are
+/-
1/2" due to adjustable feet.
Left-to-Right machine shown.
Right-to-Left machine is a
mirror image.
All dimensions from floor are
+/- 1/2" due to adjustable feet.
1' 10-1/8"
(562mm)
door
opening
2' 11-3/8"
(900mm)
4' 6-5/8"
(1388mm)
2' 6-1/2"
(775mm)
B-US 231 PW Technical Specifications
Machine Electrical Specifications
Total Machine Current Draw: 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph
Electric tank heat, 40°F/22°C rise booster 151.8 A 137.5 A 67.5 A
Electric tank heat, 70°F/39°C rise booster 176.8 A 160.0 A 78.5 A
Electric tank heat, opt. waste air heat recovery (130°F/72°C rise) 176.8 A 160.0 A 78.5 A
Steam tank heat/steam booster 17.8 A 17.5 A 8.5 A
Single blower dryer (electric) Add 26.5 A Add 23.3 A Add 12.3 A
Single blower dryer (steam) Add 1.6 A Add 1.4 A Add 0.9 A
Dual blower dryer (electric) Add 28.0 A Add 24.6 A Add 13.1 A
Dual blower dryer (steam) Add 3.1 A Add 2.7 A Add 1.7 A
Water Specifications
Minimum water temperatures:
Prewash tank .................................................. 110°F (43°C)
Wash tank....................................................... 160°F (72°C)
Auxiliary rinse ................................................. 165°F (77°C)
Final rinse ....................................................... 180°F (82°C)
Water requirements:
Recommended fill temp ..................... 110-140°F (43-60°C)
Minimum incoming water temperature:
For 40°F/22°C minimum rise ...................... 140°F (60°C)
For 70°F/39°C minimum rise ...................... 110°F (43°C)
For 130°F/72°C minimum rise * ................... 50°F (10°C)
* Requires waste air heat recovery option.
Initial fill ................................................. 66 U.S. gals. (250l)
Consumption at 100% cap. ........... 100 U.S. gals. (379
l)/hr.
Minimum incoming water line size:
Initial fill line (units with waste heat
recovery option) or single water
connection (all other units) ....................................... 3/4” NPT
Final rinse line (units with waste heat
recovery option only) ................................................ 1/2” NPT
Minimum final rinse flow rate .................... 1.8 U.S. gals.(6.8l)/min.
Recommended max. water hardness ............ 4 grains/U.S. gal.
Drain ................................................ 3” IPS drain pipe; indirect
connection to 4” (102mm)
floor drain recommended
Tank capacities:
Prewash tank ............................................. 19 U.S. gals. (72l)
Wash tank ................................................ 31 U.S. gals. (117l)
Auxiliary rinse tank ..................................... 16 U.S. gals. (60
l)
Venting Specifications
Venting requirements (standard) ................ 471 CFM (800m
3
/h)
Venting requirements (with blower dryer) . 706 CFM (1200m
3
/h)
Room air to cool exhaust (recommended) ...... 120 CFM (202m
3
/h)
Waste air temp. (approx.) .................................. 122°F (50°C)
Waste air temp. (with optional waste
air heat recovery option, approx.) ....................... 95°F (35°C)
Operating Capacities (NSF Rated)
Dishes per hour (maximum) ...........................................7,920
Consumption ..................................... 100 U.S. gals. (379
l)/hr.
Conveyor Specifications
Conveyor belt speed:
Minimum ........................................................ 4’ (1.2m)/min.
Maximum ....................................................... 6’ (1.8m)/min.
Horizontal clearance ................................. 1’ 11-3/8” (600mm)
Vertical clearance .......................................1’ 3-3/4” (400mm)
Conveyor belt minimum peg spacing .............. 2-1/8” (55mm)
Component Electrical Specifications
Prewash pump motor ................. 0.75 hp
Wash pump motor ........................... 3 hp
Auxiliary rinse pump motor......... 0.75 hp
Final rinse pump motor .............. 0.75 hp
Conveyor motor / min spd ......... 0.17 hp
Conveyor motor / max speed ..... 0.25 hp
Vent motor .................................. 0.21 hp
Blower dryer motors (1x for single blower
dryer, 2x for dual blower dryers):
Electric or steam heat,
208 V or 240 V .......................... 0.5 hp
Electric or steam heat,
460 V ......................................... 0.6 hp
Motors:
Electric Heating Elements (electrically-
heated units only):
Wash tank .................................... 27 kW
Auxiliary rinse tank ......................... 9 kW
Booster heater / 40°F rise ........... 12 kW
Booster heater / 70°F rise ........... 21 kW
Booster heater / Waste heat
recovery option, 130°F rise ......... 21 kW
Blower dryer heater (single
or dual blower dryers ) ............. 1 x 9 kW
Steam Specifications (steam-heated units only)
Steam line connection ........................................... 1-1/2” NPT
Condensate return connection .................................... 1” NPT
Recommended steam pressure .............. 15-30 psi (1-2 bars)
Consumption
Incoming water temp. 110°F/43°C........... 216 lbs./hr. (57 kW)
Incoming water temp. 140°F/60°C .......... 182 lbs./hr. (48 kW)
Incoming water temp. 50°F/10°C (with
optional waste air heat recovery sys.) ..... 216 lbs./hr. (57 kW)
Optional steam blower dryer ................ Add 34 lbs./hr. (9 kW)
6' 4-3/4"
(1950mm)
L1
load section length
Start/stop
controls
6-1/2"
(165mm)
4' 3-1/8" (1300mm)
7' 2-5/8" (2200mm)
2' 11-3/8" (900mm)
U1
unload section length
Wash pump
3.0 hp
Final rinse
pump 0.75 hp
Aux. rinse
pump 0.75 hp
Prewash pump
3.0 hp
Control
panel
Fill vacuum
breaker
Start/stop
controls
6' 2-3/4"
(1900mm)
4-7/8"
(125mm)
1' 3-3/8"
(390mm)
2' 6-3/4"
(780mm)
3/4"
(20mm)
3-7/8"
(100mm)
1' 3-3/8"
(390mm)
8-1/4"
(210mm)
8-5/8"
(220mm)
7-7/8"
(200mm)
2' 3/4"
(630mm)
2' 11-3/8"
(900mm)
D
Front
PLAN VIEW
ELEVATION VIEW
(FRONT)
STANDARD CSS BASIC
Load section length (L1) Clear load area (L2)
2' 11-3/8" (900mm) † 1' 11-5/8" (600mm) †
3' 7-1/4" (1100mm) 2' 7-1/2" (800mm)
4' 7-1/8" (1400mm) 3' 7-1/4" (1100mm)
7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
7' 10-1/2" (2400mm)* 6' 10-5/8" (2100mm)*
OPTIONAL CSS TOP
4' 7-1/8" (1400mm) † 1' 11-5/8" (600mm) †
5' 6-7/8" (1700mm) 2' 11-3/8" (900mm)
7' 10-1/2" (2400mm) 5' 3" (1600mm)
8' 10-3/8" (2700mm)* 6' 2-3/4" (1900mm)*
10' 2" (3100mm)* 7' 6-1/2" (2300mm)*
11' 5-3/4" (3500mm)* 8' 10-3/8" (2700mm)*
LOAD SECTIONS
STANDARD
Unl (U1) Clear unload (U2)oad section
6' 2-3/4" (1900mm) 3' 5-3/8" (1050mm)
7' 6-1/2" (2300mm) † 4' 9-1/8" (1450mm) †
8' 6-3/8" (2600mm) 5' 8-7/8" (1750mm)
9' 10-1/8" (3000mm) 7' 5/8" (2150mm)
10' 9-7/8" (3300mm) 8' 1/2" (2450mm)
13' 1-1/2" (4000mm) 10' 4" (3150mm)
16' 7/8" (4900mm) 14' 9-1/8" (4500mm)
UNLOAD SECTIONS
SINGLE BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
3' 7-1/4" (1100mm)-long drying tunnel:
4' 11" (1500mm)-long drying tunnel:
6' 2-3/4" (1900mm)-long drying tunnel:
7' 6-1/2" (2300mm) 3' 11-1/4" (1200mm)
8' 6-3/8" (2600mm) † 4' 11" (1500mm) †
9' 10-1/8" (3000mm) 6' 2-3/4" (1900mm)
10' 9-7/8" (3300mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) 9' 6-1/8" (2900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
7' 6-1/2" (2300mm) 2' 7-1/2" (800mm)
8' 6-3/8" (2600mm) † 3' 7-1/4" (1100mm) †
9' 10-1/8" (3000mm) 4' 11" (1500mm)
10' 9-7/8" (3300mm) 5' 10-7/8" (1800mm)
13' 1-1/2" (4000mm) 8' 2-1/2" (2500mm)
16' 7/8" (4900mm) 11' 1-7/8" (3400mm)
9' 10-1/8" (3000mm) 3' 7-1/4" (1100mm)
10' 9-7/8" (3300mm) † 4' 7-1/8" (1400mm) †
13' 1-1/2" (4000mm) 6' 10-5/8" (2100mm)
16' 7/8" (4900mm) 9' 10-1/8" (3000mm)
DUAL BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
6' 7/8" (1850mm)-long drying tunnel:
7' 6-1/2" (2300mm)-long drying tunnel:
8' 10-3/8" (2700mm)-long drying tunnel:
10' 2" (3100mm)-long drying tunnel:
9' 10-1/8" (3000mm) 3' 9-1/4" (1150mm)
10' 9-7/8" (3300mm) † 4' 11" (1500mm) †
13' 1-1/2" (4000mm) 6' 2-3/4" (1900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
10' 9-7/8" (3300mm) 3' 3-3/8" (1000mm)
13' 1-1/2" (4000mm) † 5' 6-7/8" (1700mm) †
16' 7/8" (4900mm) 8' 6-3/8" (2600mm)
13' 1-1/2" (4000mm) † 4' 3-1/8" (1300mm) †
16' 7/8" (4900mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) † 2' 11-3/8" (900mm) †
16' 7/8" (4900mm) 5' 10-7/8" (1800mm)
B-US 231 LPW
Recommended location
for indirect floor drain
5-3/8"
(135mm)
2' 6-1/8"
(765mm)
2' 11-3/8"
(900mm)
ELEVATION VIEW (RIGHT)
1' 3-3/4" (400mm)
passing height
1' 11-3/8"
(600mm)
horizontal
clearance
ELEVATION VIEW (RIGHT)
Direction
of conveyor
belt travel
2' 5-1/8"
(740mm)
3' 4-1/8"
(1020mm)
1-5/8"
(40mm)
9-1/2"
(240mm)
2' 2-3/4"
(680mm)
8-7/8"
(225mm)
2' 2-3/4" (680mm)
2' 2-3/4" (680mm)
3' 7-1/4" (1100mm)
3' 7-1/4" (1100mm)
2' 9-1/8"
(840mm)
H
S
CR
11-7/8"
(300mm)
1' 6-7/8"
(480mm)
1' 11-1/4"
(590mm)
C
8-5/8"
(220mm)
3-7/8"
(100mm)
2' 3-1/2"
(700mm)
2' 3-1/2"
(700mm)
U2
clear unload area
6' 6-3/4"
(2000mm)
3-7/8"
(100mm)
L2
clear load area
Drain
3" (76mm) IPS drain. 4" indirect floor drain recommended.
D
Water connection(s)
3/4" NPT. on units that equipped with
optional waste air heat recovery system. Used as single water
connection on all other units.
1/2" NPT. on units equipped with optional
waste air heat recovery system. Not present on other units.
Used only for initial fill
Used only for final rinse
H
Steam connection
Units with steam tank/booster heat only. 1-1/2" NPT.
S
Condensate return connection
Units with steam tank/booster heat only. 1" NPT.
CR
Vent connection
See exhaust vent detail view.
Electrical connection
Units with steam heat: Single terminal block at the location shown.
Units with electric heat: 4 (four) individual terminal blocks, approx.
2-1/2" (64mm) apart, centered on the location shown.
Leads must be appropriate for electrical supply. Maximum wire
gauge #2 AWG. All connection points to be drilled during installation.
C
UTILITY CONNECTIONS
SUPPLIED BY
CUSTOMER:
Vent shroud to be
constructed with 1"
(25mm) trough to
collect condensation,
which can be
drained into machine
SUPPLIED WITH
MACHINE:
Exhaust vent
VENT
DETAIL
VIEW
1' 7-5/8" (500mm) dia.
1' 5-3/4" (450mm) dia.
1' 3-3/4"
(400mm) dia.
Gap permits
room air to
enter vent
shroud
Condensation
can be drained
into machine
(drain supplied
by customer)
Condensation
trough
Vent shroud
(supplied by
customer)
3-1/8"
(80mm)
3-7/8"
(100mm)
* With optional 2' 6-3/8" (770mm) loading height
Recommended standard element. Consult
Meiko for special ware considerations.
Recommended standard element.
Consult Meiko for special ware
considerations.
Left-to-Right machine shown.
Right-to-Left
machine is a
mirror
image.
All
dimensions from floor are
+/-
1/2" due to adjustable feet.
Left-to-Right machine shown.
Right-to-Left machine is a
mirror image.
All dimensions from floor are
+/- 1/2" due to adjustable feet.
1' 10-1/8"
(562mm)
door
opening
2' 11-3/8"
(900mm)
4' 6-5/8"
(1388mm)
2' 6-1/2"
(775mm)
B-US 231 LPW Technical Specifications
Machine Electrical Specifications
Total Machine Current Draw: 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph
Electric tank heat, 40°F/22°C rise booster 157.5 A 142.9 A 69.7 A
Electric tank heat, 70°F/39°C rise booster 182.5 A 165.4 A 80.7 A
Electric tank heat, opt. waste air heat recovery (130°F/72°C rise) 182.5 A 165.4 A 80.7 A
Steam tank heat/steam booster 23.5 A 22.9 A 10.7 A
Single blower dryer (electric) Add 26.5 A Add 23.3 A Add 12.3 A
Single blower dryer (steam) Add 1.6 A Add 1.4 A Add 0.9 A
Dual blower dryer (electric) Add 28.0 A Add 24.6 A Add 13.1 A
Dual blower dryer (steam) Add 3.1 A Add 2.7 A Add 1.7 A
CSS Top Add 3.9 A Add 3.9 A Add 2.3 A
Water Specifications
Minimum water temperatures:
Prewash tank .................................................. 110°F (43°C)
Wash tank....................................................... 160°F (72°C)
Auxiliary rinse ................................................. 165°F (77°C)
Final rinse ....................................................... 180°F (82°C)
Water requirements:
Recommended fill temp ..................... 110-140°F (43-60°C)
Minimum incoming water temperature:
For 40°F/22°C minimum rise ...................... 140°F (60°C)
For 70°F/39°C minimum rise ...................... 110°F (43°C)
For 130°F/72°C minimum rise * ................... 50°F (10°C)
* Requires waste air heat recovery option.
Initial fill ................................................. 76 U.S. gals. (288
l)
Consumption at 100% cap. ........... 100 U.S. gals. (379
l)/hr.
Minimum incoming water line size:
Initial fill line (units with waste heat
recovery option) or single water
connection (all other units) ....................................... 3/4” NPT
Final rinse line (units with waste heat
recovery option only) ................................................ 1/2” NPT
Minimum final rinse flow rate .................... 2.1 U.S. gals.(8.0l)/min.
Recommended max. water hardness ............ 4 grains/U.S. gal.
Drain ................................................ 3” IPS drain pipe; indirect
connection to 4” (102mm)
floor drain recommended
Tank capacities:
Prewash tank ........................................... 29 U.S. gals. (110l )
Wash tank ................................................ 31 U.S. gals. (117l)
Auxiliary rinse tank ..................................... 16 U.S. gals. (60l)
Venting Specifications
Venting requirements (standard) ................ 471 CFM (800m
3
/h)
Venting requirements (with blower dryer) . 706 CFM (1200m
3
/h)
Room air to cool exhaust (recommended) ...... 120 CFM (202m
3
/h)
Waste air temp. (approx.) .................................. 122°F (50°C)
Waste air temp. (with optional waste
air heat recovery option, approx.) ....................... 95°F (35°C)
Operating Capacities (NSF Rated)
Dishes per hour (maximum) ........................................ 10,560
Consumption ..................................... 100 U.S. gals. (379
l)/hr.
Conveyor Specifications
Conveyor belt speed:
Minimum .................................................... 5’ 4” (1.6m)/min.
Maximum ....................................................... 8’ (2.4m)/min.
Horizontal clearance ................................. 1’ 11-3/8” (600mm)
Vertical clearance .......................................1’ 3-3/4” (400mm)
Conveyor belt minimum peg spacing .............. 2-1/8” (55mm)
Component Electrical Specifications
Prewash pump motor ...................... 3 hp
Wash pump motor ........................... 3 hp
Auxiliary rinse pump motor......... 0.75 hp
Final rinse pump motor .............. 0.75 hp
Conveyor motor / min spd ......... 0.17 hp
Conveyor motor / max speed ..... 0.25 hp
Vent motor .................................. 0.21 hp
CSS Top pump motor ...................... 1 hp
Blower dryer motors (1x for single blower
dryer, 2x for dual blower dryers):
Electric or steam heat,
208 V or 240 V .......................... 0.5 hp
Electric or steam heat,
460 V ......................................... 0.6 hp
Motors:
Electric Heating Elements (electrically-
heated units only):
Wash tank .................................... 27 kW
Auxiliary rinse tank ......................... 9 kW
Booster heater / 40°F rise ........... 12 kW
Booster heater / 70°F rise ........... 21 kW
Booster heater / Waste heat
recovery option, 130°F rise ......... 21 kW
Blower dryer heater (single
or dual blower dryers ) ............. 1 x 9 kW
Steam Specifications (steam-heated units only)
Steam line connection ........................................... 1-1/2” NPT
Condensate return connection .................................... 1” NPT
Recommended steam pressure .............. 15-30 psi (1-2 bars)
Consumption
Incoming water temp. 110°F/43°C........... 216 lbs./hr. (57 kW)
Incoming water temp. 140°F/60°C .......... 182 lbs./hr. (48 kW)
Incoming water temp. 50°F/10°C (with
optional waste air heat recovery sys.) ..... 216 lbs./hr. (57 kW)
Optional steam blower dryer ................ Add 34 lbs./hr. (9 kW)
6' 4-3/4"
(1950mm)
L1
load section length
Start/stop
controls
6-1/2"
(165mm)
4' 3-1/8" (1300mm)
10' 2" (3100mm)
2' 11-3/8" (900mm)2' 11-3/8" (900mm)
U1
unload section length
Wash pump
3.0 hp
Final rinse
pump 0.75 hp
Aux. rinse
pump 0.75 hp
Wash pump
3.0 hp
Prewash pump
3.0 hp
Control
panel
Fill vacuum
breaker
Start/stop
controls
6' 2-3/4"
(1900mm)
4-7/8"
(125mm)
1' 3-3/8"
(390mm)
2' 6-3/4"
(780mm)
3/4"
(20mm)
3-7/8"
(100mm)
1' 3-3/8"
(390mm)
8-1/4"
(210mm)
8-5/8"
(220mm)
7-7/8"
(200mm)
2' 3/4"
(630mm)
2' 11-3/8"
(900mm)
D
Front
ELEVATION VIEW (FRONT)
STANDARD CSS BASIC
Load section length (L1) Clear load area (L2)
2' 11-3/8" (900mm) † 1' 11-5/8" (600mm) †
3' 7-1/4" (1100mm) 2' 7-1/2" (800mm)
4' 7-1/8" (1400mm) 3' 7-1/4" (1100mm)
7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
**7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
OPTIONAL CSS TOP
4' 7-1/8" (1400mm) † 1' 11-5/8" (600mm) †
5' 6-7/8" (1700mm) 2' 11-3/8" (900mm)
7' 10-1/2" (2400mm) 5' 3" (1600mm)
**
**
**
8' 10-3/8" (2700mm) 6' 2-3/4" (1900mm)
10' 2" (3100mm) 7' 6-1/2" (2300mm)
11' 5-3/4" (3500mm) 8' 10-3/8" (2700mm)
LOAD SECTIONS
STANDARD
Unl (U1) Clear unload (U2)oad section
6' 2-3/4" (1900mm) 3' 5-3/8" (1050mm)
7' 6-1/2" (2300mm) 4' 9-1/8" (1450mm)
8' 6-3/8" (2600mm) † 5' 8-7/8" (1750mm) †
9' 10-1/8" (3000mm) 7' 5/8" (2150mm)
10' 9-7/8" (3300mm) 8' 1/2" (2450mm)
13' 1-1/2" (4000mm) 10' 4" (3150mm)
16' 7/8" (4900mm) 14' 9-1/8" (4500mm)
UNLOAD SECTIONS
SINGLE BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
3' 7-1/4" (1100mm)-long drying tunnel:
4' 11" (1500mm)-long drying tunnel:
6' 2-3/4" (1900mm)-long drying tunnel:
7' 6-1/2" (2300mm) 3' 11-1/4" (1200mm)
8' 6-3/8" (2600mm) † 4' 11" (1500mm) †
9' 10-1/8" (3000mm) 6' 2-3/4" (1900mm)
10' 9-7/8" (3300mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) 9' 6-1/8" (2900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
7' 6-1/2" (2300mm) 2' 7-1/2" (800mm)
8' 6-3/8" (2600mm) 3' 7-1/4" (1100mm)
9' 10-1/8" (3000mm) † 4' 11" (1500mm) †
10' 9-7/8" (3300mm) 5' 10-7/8" (1800mm)
13' 1-1/2" (4000mm) 8' 2-1/2" (2500mm)
16' 7/8" (4900mm) 11' 1-7/8" (3400mm)
9' 10-1/8" (3000mm) † 3' 7-1/4" (1100mm) †
10' 9-7/8" (3300mm) 4' 7-1/8" (1400mm)
13' 1-1/2" (4000mm) 6' 10-5/8" (2100mm)
16' 7/8" (4900mm) 9' 10-1/8" (3000mm)
DUAL BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
6' 7/8" (1850mm)-long drying tunnel:
7' 6-1/2" (2300mm)-long drying tunnel:
8' 10-3/8" (2700mm)-long drying tunnel:
10' 2" (3100mm)-long drying tunnel:
9' 10-1/8" (3000mm) 3' 9-1/4" (1150mm)
10' 9-7/8" (3300mm) † 4' 11" (1500mm) †
13' 1-1/2" (4000mm) 6' 2-3/4" (1900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
10' 9-7/8" (3300mm) † 3' 3-3/8" (1000mm) †
13' 1-1/2" (4000mm) 5' 6-7/8" (1700mm)
16' 7/8" (4900mm) 8' 6-3/8" (2600mm)
13' 1-1/2" (4000mm) † 4' 3-1/8" (1300mm) †
16' 7/8" (4900mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) † 2' 11-3/8" (900mm) †
16' 7/8" (4900mm) 5' 10-7/8" (1800mm)
B-US 232 LPW
Recommended location
for indirect floor drain
5-3/8"
(135mm)
2' 6-1/8"
(765mm)
2' 11-3/8"
(900mm)
PLAN VIEW
Direction
of conveyor
belt travel
1' 3-3/4" (400mm)
passing height
1' 11-3/8"
(600mm)
horizontal
clearance
ELEVATION VIEW (RIGHT)
Drain
3" (76mm) IPS drain. 4" indirect floor drain recommended.
D
Water connection(s)
3/4" NPT. on units that equipped with
optional waste air heat recovery system. Used as single water
connection on all other units.
1/2" NPT. on units equipped with optional
waste air heat recovery system. Not present on other units.
Used only for initial fill
Used only for final rinse
H
Steam connection
Units with steam tank/booster heat only. 1-1/2" NPT.
S
Condensate return connection
Units with steam tank/booster heat only. 1" NPT.
CR
Vent connection
See exhaust vent detail view.
Electrical connection
Units with steam heat: Single terminal block at the location shown.
Units with electric heat: 4 (four) individual terminal blocks, approx.
2-1/2" (64mm) apart, centered on the location shown.
Leads must be appropriate for electrical supply. Maximum wire
gauge #2 AWG. All connection points to be drilled during installation.
C
UTILITY CONNECTIONS
SUPPLIED BY
CUSTOMER:
Vent shroud to be
constructed with 1"
(25mm) trough to
collect condensation,
which can be
drained into machine
SUPPLIED WITH
MACHINE:
Exhaust vent
VENT
DETAIL
VIEW
1' 7-5/8" (500mm) dia.
1' 5-3/4" (450mm) dia.
1' 3-3/4"
(400mm) dia.
Gap permits
room air to
enter vent
shroud
Condensation
can be drained
into machine
(drain supplied
by customer)
Condensation
trough
Vent shroud
(supplied by
customer)
3-1/8"
(80mm)
3-7/8"
(100mm)
* With optional 2' 6-3/8" (770mm) loading height
Recommended standard element. Consult
Meiko for special ware considerations.
Recommended standard element.
Consult Meiko for special ware
considerations.
2' 5-1/8"
(740mm)
3' 4-1/8"
(1020mm)
1-5/8"
(40mm)
9-1/2"
(240mm)
2' 2-3/4"
(680mm)
8-7/8"
(225mm)
2' 2-3/4" (680mm)
2' 2-3/4" (680mm)
3' 7-1/4" (1100mm)
3' 7-1/4" (1100mm)
2' 9-1/8"
(840mm)
H
S
CR
11-7/8"
(300mm)
1' 6-7/8"
(480mm)
1' 11-1/4"
(590mm)
C
8-5/8"
(220mm)
3-7/8"
(100mm)
2' 3-1/2"
(700mm)
2' 3-1/2"
(700mm)
U2
clear unload area
6' 6-3/4"
(2000mm)
3-7/8"
(100mm)
L2
clear load area
Left-to-Right machine shown.
Right-to-Left
machine is a
mirror
image.
All
dimensions from floor are
+/-
1/2" due to adjustable feet.
Left-to-Right machine shown.
Right-to-Left machine is a
mirror image.
All dimensions from floor are
+/- 1/2" due to adjustable feet.
1' 10-1/8"
(562mm)
door
opening
2' 11-3/8"
(900mm)
4' 6-5/8"
(1388mm)
2' 6-1/2"
(775mm)
B-US 232 LPW Technical Specifications
Machine Electrical Specifications
Total Machine Current Draw: 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph
Electric tank heat, 40°F/22°C rise booster 175.0 A 166.0 A 80.8 A
Electric tank heat, 70°F/39°C rise booster 200.0 A 188.5 A 91.8 A
Electric tank heat, opt. waste air heat recovery (130°F/72°C rise) 200.0 A 188.5 A 91.8 A
Steam tank heat/steam booster 32.0 A 31.2 A 14.3 A
Single blower dryer (electric) Add 26.5 A Add 23.3 A Add 12.3 A
Single blower dryer (steam) Add 1.6 A Add 1.4 A Add 0.9 A
Dual blower dryer (electric) Add 28.0 A Add 24.6 A Add 13.1 A
Dual blower dryer (steam) Add 3.1 A Add 2.7 A Add 1.7 A
CSS Top Add 3.9 A Add 3.9 A Add 2.3 A
Water Specifications
Minimum water temperatures:
Prewash tank .................................................. 110°F (43°C)
Wash tank....................................................... 150°F (66°C)
Recirculating rinse tank .................................. 160°F (72°C)
Auxiliary rinse ................................................. 165°F (77°C)
Final rinse ....................................................... 180°F (82°C)
Water requirements:
Recommended fill temp ..................... 110-140°F (43-60°C)
Minimum incoming water temperature:
For 40°F/22°C minimum rise ...................... 140°F (60°C)
For 70°F/39°C minimum rise ...................... 110°F (43°C)
For 130°F/72°C minimum rise * ................... 50°F (10°C)
* Requires waste air heat recovery option.
Initial fill ............................................... 109 U.S. gals. (413
l)
Consumption at 100% cap. ........... 121 U.S. gals. (458
l)/hr.
Minimum incoming water line size:
Initial fill line (units with waste heat
recovery option) or single water
connection (all other units) ....................................... 3/4” NPT
Final rinse line (units with waste heat
recovery option only) ................................................ 1/2” NPT
Minimum final rinse flow rate .................... 2.1 U.S. gals.(8.0l)/min.
Recommended max. water hardness ............ 4 grains/U.S. gal.
Drain ................................................ 3” IPS drain pipe; indirect
connection to 4” (102mm)
floor drain recommended
Tank capacities:
Prewash tank ........................................... 29 U.S. gals. (110l )
Wash tank ................................................ 31 U.S. gals. (117l)
Recirculating rinse tank ........................... 33 U.S. gals. (125l)
Auxiliary rinse tank ..................................... 16 U.S. gals. (60l)
Venting Specifications
Venting requirements (standard) ............... 648 CFM (1100m
3
h)
Venting requirements (with blower dryer) .. 883 CFM (1500m
3
h)
Room air to cool exhaust (recommended) ...... 120 CFM (202m
3
/h)
Waste air temp. (approx.) .................................. 122°F (50°C)
Waste air temp. (with optional waste
air heat recovery option, approx.) ....................... 95°F (35°C)
Operating Capacities (NSF Rated)
Dishes per hour (maximum) ........................................ 13,200
Consumption ..................................... 121 U.S. gals. (458
l)/hr.
Conveyor Specifications
Conveyor belt speed:
Minimum .................................................... 6’ 8” (2.0m)/min.
Maximum ..................................................... 10’ (3.0m)/min.
Horizontal clearance ................................. 1’ 11-3/8” (600mm)
Vertical clearance .......................................1’ 3-3/4” (400mm)
Conveyor belt minimum peg spacing .............. 2-1/8” (55mm)
Component Electrical Specifications
Prewash pump motor ...................... 3 hp
Wash pump motor ........................... 3 hp
Recirculating rinse pump motor ...... 3 hp
Auxiliary rinse pump motor......... 0.75 hp
Final rinse pump motor .............. 0.75 hp
Conveyor motor / min spd ......... 0.17 hp
Conveyor motor / max speed ..... 0.25 hp
Vent motor .................................. 0.21 hp
CSS Top pump motor ...................... 1 hp
Blower dryer motors (1x for single blower
dryer, 2x for dual blower dryers):
Electric or steam heat,
208 V or 240 V .......................... 0.5 hp
Electric or steam heat,
460 V ......................................... 0.6 hp
Motors:
Electric Heating Elements (electrically-
heated units only):
Wash tank .................................... 12 kW
Recirculating rinse tank ............... 18 kW
Auxiliary rinse tank ......................... 9 kW
Booster heater / 40°F rise ........... 15 kW
Booster heater / 70°F rise ........... 24 kW
Booster heater / Waste heat
recovery option, 130°F rise ......... 24 kW
Blower dryer heater (single
or dual blower dryers ) ............. 1 x 9 kW
Steam Specifications (steam-heated units only)
Steam line connection ........................................... 1-1/2” NPT
Condensate return connection .................................... 1” NPT
Recommended steam pressure .............. 15-30 psi (1-2 bars)
Consumption
Incoming water temp. 110°F/43°C........... 239 lbs./hr. (63 kW)
Incoming water temp. 140°F/60°C .......... 205 lbs./hr. (54 kW)
Incoming water temp. 50°F/10°C (with
optional waste air heat recovery sys.) ..... 239 lbs./hr. (63 kW)
Optional steam blower dryer ................ Add 34 lbs./hr. (9 kW)
6' 4-3/4"
(1950mm)
L1
load section length
Start/stop
controls
6-1/2"
(165mm)
2' 11-3/8" (900mm) 4' 3-1/8" (1300mm)
13' 1-1/2" (4000mm)
2' 11-3/8" (900mm)2' 11-3/8" (900mm)
U1
unload section length
U2
clear unload area
Wash pump
3.0 hp
Recirculating
rinse pump
3.0 hp
Final rinse
pump 0.75 hp
Aux. rinse
pump 0.75 hp
Wash pump
3.0 hp
Prewash pump
3.0 hp
Control
panel
Fill vacuum
breaker
Start/stop
controls
5-3/8"
(135mm)
2' 6-1/8"
(765mm)
2' 11-3/8"
(900mm)
6' 2-3/4"
(1900mm)
6' 6-3/4"
(2000mm)
3-7/8"
(100mm)
4-7/8"
(125mm)
1' 3-3/8"
(390mm)
2' 6-3/4"
(780mm)
3/4"
(20mm)
3-7/8"
(100mm)
1' 3-3/8"
(390mm)
8-1/4"
(210mm)
8-5/8"
(220mm)
7-7/8"
(200mm)
2' 3/4"
(630mm)
2' 11-3/8"
(900mm)
2' 5-1/8"
(740mm)
3' 4-1/8"
(1020mm)
1-5/8"
(40mm)
9-1/2"
(240mm)
2' 2-3/4"
(680mm)
D
8-7/8"
(225mm)
Direction of
conveyor belt
travel
Front
PLAN VIEW
ELEVATION VIEW (FRONT)
2' 2-3/4" (680mm)
2' 2-3/4" (680mm)
3' 7-1/4" (1100mm)
3' 7-1/4" (1100mm)
STANDARD CSS BASIC
Load section length (L1) Clear load area (L2)
2' 11-3/8" (900mm) † 1' 11-5/8" (600mm) †
3' 7-1/4" (1100mm) 2' 7-1/2" (800mm)
4' 7-1/8" (1400mm) 3' 7-1/4" (1100mm)
7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
**7' 10-1/2" (2400mm) 6' 10-5/8" (2100mm)
OPTIONAL CSS TOP
4' 7-1/8" (1400mm) † 1' 11-5/8" (600mm) †
5' 6-7/8" (1700mm) 2' 11-3/8" (900mm)
7' 10-1/2" (2400mm) 5' 3" (1600mm)
**
**
**
8' 10-3/8" (2700mm) 6' 2-3/4" (1900mm)
10' 2" (3100mm) 7' 6-1/2" (2300mm)
11' 5-3/4" (3500mm) 8' 10-3/8" (2700mm)
LOAD SECTIONS
STANDARD
Unl (U1) Clear unload (U2)oad section
6' 2-3/4" (1900mm) 3' 5-3/8" (1050mm)
7' 6-1/2" (2300mm) 4' 9-1/8" (1450mm)
8' 6-3/8" (2600mm) 5' 8-7/8" (1750mm)
9' 10-1/8" (3000mm) 7' 5/8" (2150mm)
10' 9-7/8" (3300mm) † 8' 1/2" (2450mm) †
13' 1-1/2" (4000mm) 10' 4" (3150mm)
16' 7/8" (4900mm) 14' 9-1/8" (4500mm)
UNLOAD SECTIONS
SINGLE BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
3' 7-1/4" (1100mm)-long drying tunnel:
4' 11" (1500mm)-long drying tunnel:
6' 2-3/4" (1900mm)-long drying tunnel:
7' 6-1/2" (2300mm) 3' 11-1/4" (1200mm)
8' 6-3/8" (2600mm) 4' 11" (1500mm)
9' 10-1/8" (3000mm) 6' 2-3/4" (1900mm)
10' 9-7/8" (3300mm) † 7' 2-5/8" (2200mm) †
13' 1-1/2" (4000mm) 9' 6-1/8" (2900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
7' 6-1/2" (2300mm) 2' 7-1/2" (800mm)
8' 6-3/8" (2600mm) 3' 7-1/4" (1100mm)
9' 10-1/8" (3000mm) 4' 11" (1500mm)
10' 9-7/8" (3300mm) † 5' 10-7/8" (1800mm) †
13' 1-1/2" (4000mm) 8' 2-1/2" (2500mm)
16' 7/8" (4900mm) 11' 1-7/8" (3400mm)
9' 10-1/8" (3000mm) 3' 7-1/4" (1100mm)
10' 9-7/8" (3300mm) † 4' 7-1/8" (1400mm) †
13' 1-1/2" (4000mm) 6' 10-5/8" (2100mm)
16' 7/8" (4900mm) 9' 10-1/8" (3000mm)
DUAL BLOWER DRYER
Unl (U1) Clear unload (U2)oad section
6' 7/8" (1850mm)-long drying tunnel:
7' 6-1/2" (2300mm)-long drying tunnel:
8' 10-3/8" (2700mm)-long drying tunnel:
10' 2" (3100mm)-long drying tunnel:
9' 10-1/8" (3000mm) 3' 9-1/4" (1150mm)
10' 9-7/8" (3300mm) † 4' 11" (1500mm) †
13' 1-1/2" (4000mm) 6' 2-3/4" (1900mm)
16' 7/8" (4900mm) 12' 5-5/8" (3800mm)
10' 9-7/8" (3300mm) 3' 3-3/8" (1000mm)
13' 1-1/2" (4000mm) † 5' 6-7/8" (1700mm) †
16' 7/8" (4900mm) 8' 6-3/8" (2600mm)
13' 1-1/2" (4000mm) † 4' 3-1/8" (1300mm) †
16' 7/8" (4900mm) 7' 2-5/8" (2200mm)
13' 1-1/2" (4000mm) † 2' 11-3/8" (900mm) †
16' 7/8" (4900mm) 5' 10-7/8" (1800mm)
B-US 233 LPW
Recommended location
for indirect floor drain
1' 3-3/4" (400mm)
passing height
1' 11-3/8"
(600mm)
horizontal
clearance
ELEVATION VIEW (RIGHT)
Drain
3" (76mm) IPS drain. 4" indirect floor drain recommended.
D
Water connection(s)
3/4" NPT. on units that equipped with
optional waste air heat recovery system. Used as single water
connection on all other units.
1/2" NPT. on units equipped with optional
waste air heat recovery system. Not present on other units.
Used only for initial fill
Used only for final rinse
H
Steam connection
Units with steam tank/booster heat only. 1-1/2" NPT.
S
Condensate return connection
Units with steam tank/booster heat only. 1" NPT.
CR
Vent connection
See exhaust vent detail view.
Electrical connection
Units with steam heat: Single terminal block at the location shown.
Units with electric heat: 4 (four) individual terminal blocks, approx.
2-1/2" (64mm) apart, centered on the location shown.
Leads must be appropriate for electrical supply. Maximum wire
gauge #2 AWG. All connection points to be drilled during installation.
C
UTILITY CONNECTIONS
SUPPLIED BY
CUSTOMER:
Vent shroud to be
constructed with 1"
(25mm) trough to
collect condensation,
which can be
drained into machine
SUPPLIED WITH
MACHINE:
Exhaust vent
VENT
DETAIL
VIEW
1' 7-5/8" (500mm) dia.
1' 5-3/4" (450mm) dia.
1' 3-3/4"
(400mm) dia.
Gap permits
room air to
enter vent
shroud
Condensation
can be drained
into machine
(drain supplied
by customer)
Condensation
trough
Vent shroud
(supplied by
customer)
3-1/8"
(80mm)
3-7/8"
(100mm)
2' 9-1/8"
(840mm)
H
S
CR
11-7/8"
(300mm)
1' 6-7/8"
(480mm)
1' 11-1/4"
(590mm)
C
8-5/8"
(220mm)
3-7/8"
(100mm)
2' 3-1/2"
(700mm)
2' 3-1/2"
(700mm)
* With optional 2' 6-3/8" (770mm) loading height
Recommended standard element. Consult
Meiko for special ware considerations.
Recommended standard element.
Consult Meiko for special ware
considerations.
L2
clear load area
Left-to-Right
machine
shown.
Right-
to-Left
machine
is a
mirror
image.
All
dimensions
from
floor are
+/-
1/2" due to
adjustable
feet.
Left-to-Right
machine
shown. Right-
to-Left
machine is a
mirror image.
All dimensions
from floor are
+/- 1/2" due to
adjustable feet.
1' 10-1/8"
(562mm)
door
opening
2' 11-3/8"
(900mm)
4' 6-5/8"
(1388mm)
2' 6-1/2"
(775mm)
Machine Electrical Specifications
Total Machine Current Draw: 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph
Electric tank heat, 40°F/22°C rise booster 227.5 A 205.0 A 99.4 A
Electric tank heat, 70°F/39°C rise booster 267.5 A 242.0 A 117.9 A
Electric tank heat, opt. waste air heat recovery (130°F/72°C rise) 267.5 A 242.0 A 117.9 A
Steam tank heat/steam booster 40.5 A 39.5 A 17.9 A
Single blower dryer (electric) Add 26.5 A Add 23.3 A Add 12.3 A
Single blower dryer (steam) Add 1.6 A Add 1.4 A Add 0.9 A
Dual blower dryer (electric) Add 28.0 A Add 24.6 A Add 13.1 A
Dual blower dryer (steam) Add 3.1 A Add 2.7 A Add 1.7 A
CSS Top Add 3.9 A Add 3.9 A Add 2.3 A
Water Specifications
Minimum water temperatures:
Prewash tank .................................................. 110°F (43°C)
Wash tank 1 ................................................... 150°F (66°C)
Wash tank 2 ................................................... 150°F (66°C)
Recirculating rinse tank .................................. 160°F (72°C)
Auxiliary rinse ................................................. 165°F (77°C)
Final rinse ....................................................... 180°F (82°C)
Water requirements:
Recommended fill temp ..................... 110-140°F (43-60°C)
Minimum incoming water temperature:
For 40°F/22°C minimum rise ...................... 140°F (60°C)
For 70°F/39°C minimum rise ...................... 110°F (43°C)
For 130°F/72°C minimum rise * ................... 50°F (10°C)
* Requires waste air heat recovery option.
Initial fill ............................................... 141 U.S. gals. (534
l)
Consumption at 100% cap. ........... 137 U.S. gals. (519
l)/hr.
Minimum incoming water line size:
Initial fill line (units with waste heat
recovery option) or single water
connection (all other units) ....................................... 3/4” NPT
Final rinse line (units with waste heat
recovery option only) ................................................ 1/2” NPT
Minimum final rinse flow rate .................... 2.4 U.S. gals.(9.1
l)/min.
Recommended max. water hardness ............ 4 grains/U.S. gal.
Drain ................................................ 3” IPS drain pipe; indirect
connection to 4” (102mm)
floor drain recommended
Tank capacities:
Prewash tank ........................................... 29 U.S. gals. (110l )
Wash tank 1 ............................................. 31 U.S. gals. (117l )
Wash tank 2 ............................................. 33 U.S. gals. (125l)
Recirculating rinse tank ........................... 33 U.S. gals. (125l)
Auxiliary rinse tank ..................................... 16 U.S. gals. (60l)
Venting Specifications
Venting requirements (standard) ............... 824 CFM (1400m
3
h)
Venting requirements (with blower dryer) 1060 CFM (1800m
3
h)
Room air to cool exhaust (recommended) ...... 120 CFM (202m
3
/h)
Waste air temp. (approx.) .................................. 122°F (50°C)
Waste air temp. (with optional waste
air heat recovery option, approx.) ....................... 95°F (35°C)
Operating Capacities (NSF Rated)
Dishes per hour (maximum) ........................................ 15,840
Consumption ..................................... 137 U.S. gals. (519
l)/hr.
Conveyor Specifications
Conveyor belt speed:
Minimum ........................................................ 8’ (2.4m)/min.
Maximum ..................................................... 12’ (3.7m)/min.
Horizontal clearance ................................. 1’ 11-3/8” (600mm)
Vertical clearance .......................................1’ 3-3/4” (400mm)
Conveyor belt minimum peg spacing .............. 2-1/8” (55mm)
B-US 233 LPW Technical Specifications
Component Electrical Specifications
Prewash pump motor ...................... 3 hp
Wash pump motors ................... 2 x 3 hp
Recirculating rinse pump motor ...... 3 hp
Auxiliary rinse pump motor......... 0.75 hp
Final rinse pump motor .............. 0.75 hp
Conveyor motor / min spd ......... 0.17 hp
Conveyor motor / max speed ..... 0.25 hp
Vent motor .................................. 0.21 hp
CSS Top pump motor ...................... 1 hp
Blower dryer motors (1x for single blower
dryer, 2x for dual blower dryers):
Electric or steam heat,
208 V or 240 V .......................... 0.5 hp
Electric or steam heat,
460 V ......................................... 0.6 hp
Motors:
Electric Heating Elements (electrically-
heated units only):
Wash tanks ............................. 2 x 12 kW
Recirculating rinse tank ............... 18 kW
Auxiliary rinse tank ......................... 9 kW
Booster heater / 40°F rise ........... 15 kW
Booster heater / 70°F rise ........... 30 kW
Booster heater / Waste heat
recovery option, 130°F rise ......... 30 kW
Blower dryer heater (single
or dual blower dryers ) ............. 1 x 9 kW
Steam Specifications (steam-heated units only)
Steam line connection ........................................... 1-1/2” NPT
Condensate return connection .................................... 1” NPT
Recommended steam pressure .............. 15-30 psi (1-2 bars)
Consumption
Incoming water temp. 110°F/43°C........... 307 lbs./hr. (81 kW)
Incoming water temp. 140°F/60°C .......... 250 lbs./hr. (66 kW)
Incoming water temp. 50°F/10°C (with
optional waste air heat recovery sys.) ..... 307 lbs./hr. (81 kW)
Optional steam blower dryer ................ Add 34 lbs./hr. (9 kW)
Equipment Specification:
B-US 23 Series Rackless Conveyor Dishwasher - Item No. _______________
Item will be a:
____ B-US 231 flight-type dishmachine. The dishmachine will consist of a wash compartment with 3 hp pump motor
and a final rinse compartment. Final rinse compartment will consist of a pumped auxiliary rinse and a pumped final
rinse, each with a 3/4 hp pump motor. Total length of the tank section will be 4’ 3-1/8” (1300mm), to which a load
and unload end will be added (various sizes are available - see below).
____ B-US 231 PW flight-type dishmachine. The dishmachine will consist of a prewash compartment with 3/4 hp pump
motor, a wash compartment with 3 hp pump motor, and a final rinse compartment. Final rinse compartment will
consist of a pumped auxiliary rinse and a pumped final rinse, each with a 3/4 hp pump motor. Total length of the
tank section will be 6’ 2-3/4” (1900mm), to which a load and unload end will be added (various sizes are avail-
able - see below).
____ B-US 231 LPW flight-type dishmachine. The dishmachine will consist of a prewash compartment with 3 hp pump
motor, a wash compartment with 3 hp pump motor, and a final rinse compartment. Final rinse compartment will
consist of a pumped auxiliary rinse and a pumped final rinse, each with a 3/4 hp pump motor. Total length of the
tank section will be 7’ 2-5/8” (2200mm), to which a load and unload end will be added (various sizes are available -
see below).
____ B-US 232 LPW flight-type dishmachine. The dishmachine will consist of a prewash compartment with 3 hp pump
motor, a wash compartment with 3 hp pump motor, a recirculating rinse compartment with 3 hp pump motor, and
a final rinse compartment. Final rinse compartment will consist of a pumped auxiliary rinse and a pumped final
rinse, each with a 3/4 hp pump motor. Total length of the tank section will be 10’ 2” (3100mm), to which a load and
unload end will be added (various sizes are available - see below).
____ B-US 233 LPW flight-type dishmachine. The dishmachine will consist of a prewash compartment with 3 hp pump
motor, two wash compartments (each with one 3 hp pump motor), a recirculating rinse compartment with 3 hp
pump motor, and a final rinse compartment. Final rinse compartment will consist of a pumped auxiliary rinse and
a pumped final rinse, each with a 3/4 hp pump motor. Total length of the tank section will be 13’ 1-1/2” (4000mm),
to which a load and unload end will be added (various sizes are available - see below).
The dishmachine will be NSF, UL and CUL listed.
Electrical characteristics:
____ 208V/60 Hz/3 Ph
____ 230V/60 Hz/3 Ph
____ 460V/60 Hz/3 Ph
____ Other (specify)
Wash tank temperature will be maintained at a minimum of 160°F/72°C. Tank heating will be accomplished by:
____ Thermostatically-controlled electric heating elements
____ Thermostatically-controlled stainless steel steam coils
Built-in booster heater (for units without the optional Waste Air Heat Recovery System) will be:
____ Electric
____ Steam - specify steam pressure: ____ PSI.
NOTE: 15-30 PSI (1.0-2.0 bars) steam pressure is REQUIRED. Consult the factory if pressure is below 15
PSI/1.0 bars. If pressure is above 30 PSI/2.0 bars, use of a regulator (supplied by the customer) is REQUIRED.
____ Sized for a minimum 40°F (22°C) rise and 140°F (60°C) minimum incoming water temperature
____ Sized for a minimum 70°F (39°C) rise and 110°F (43°C) minimum incoming water temperature
Direction of conveyor travel will be:
____ Right-to-Left
____ Left-to-Right
Unit will have the following size load end (for units without the optional CSS Top system):
____ 2’ 11-3/8” (900mm) with 1’ 11-5/8” (600mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 3’ 7-1/4” (1100mm) with 2’ 7-1/2” (800mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 4’ 7-1/8” (1400mm) with 3’ 7-1/4” (1100mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 7’ 10-1/2” (2400mm) with 6’ 10-5/8” (2100mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 7’ 10-1/2” (2400mm) with 6’ 10-5/8” (2100mm) clear loading area and 2’ 6-3/8” (770mm) loading height
Unit will have the following size unload end (for units without an optional blower dryer system):
____ 6’ 2-3/4” (1900mm) with 3’ 5-3/8” (1050mm) clear unloading area
____ 7’ 6-1/2” (2300mm) with 4’ 9-1/8” (1450mm) clear unloading area
____ 8’ 6-3/8” (2600mm) with 5’ 8-7/8” (1750mm) clear unloading area
____ 9’ 10-1/8” (3000mm) with 7’ 5/8” (2150mm) clear unloading area
____ 10’ 9-7/8” (3300mm) with 8’ 1/2” (2450mm) clear unloading area
____ 13’ 1-1/2” (4000mm) with 10’ 4” (3150mm) clear unloading area
____ 16’ 7/8” (4900mm) with 14’ 9-1/8” (4500mm) clear unloading area
Unit will have the following standard features:
High temperature sanitizing final rinse.
Pumped final rinse and auxiliary rinse to eliminate pressure fluctuations, improve machine performance, and improve
cleaning results and consistency.
Heated auxiliary rinse zone utilizes fresh water a second time as a pre-rinse to provide pristine results.
Horizontal clearance of 1’ 11-3/8” (600mm) and a vertical clearance of 1’ 3-3/4” (400mm) throughout the machine.
Double-wall insulated construction to reduce heat loss, outside surface temperatures, and noise pollution.
Flush stainless steel exterior panels on front, top and back.
Front-sloping, V-shaped wash tank design to increase visibility and accessibility for cleaning as well as ensure complete
tank draining.
CSS Basic (Chemical Savings System) reduces detergent consumption by 30% by diverting used rinse water into the
prewash section, reducing food debris contamination in the wash tank. NOTE: CSS Basic is not used on Model
B-US 231 because the unit is not equipped with a prewash section.
Vertically-installed self-draining stainless steel pumps, impellers and housings are readily accessible for preventative
maintenance.
Easily-removable block manifold wash arms with tethered (or “captivated”) end caps and non-clogging concave nozzles
to aid cleanability.
Large, easily-removable, front-sloping stainless steel scrap screens. For units equipped with a prewash, the prewash
scrap screen will have a separate removable scrap basket for easier cleaning.
Dual-speed conveyor drive for flexibility. Drive is protected by an overload safety device and automatic shutdown
actuator.
Large, insulated front access doors have counterbalanced springs to permit single-handed operation and to eliminate
latches.
Operator-activated start-stop switches on both load and unload ends.
Automated timer switching ensures that the final rinse activates only when ware is in place.
Single-point drain and vent connections.
Potential free contacts for controlling 1 or 2 external fan contactors.
Potential free contacts for controlling a contactor for an external transport delivery system.
Unit will have the following rated capacities:
Single-tank rackless conveyor models B-US 231 and B-US 231 PW shall have a maximum capacity of 7,920 dishes
per hour at an NSF-rated belt speed of 6 feet (1.8m) per minute, with minimum conveyor peg spacing of 2-1/8”
(54mm), while consuming an NSF-rated 100 U.S. gallons (379l) per hour.
Single-tank rackless conveyor model B-US 231 LPW shall have a maximum capacity of 10,560 dishes per hour at an
NSF-rated belt speed of 8 feet (2.4m) per minute, with minimum conveyor peg spacing of 2-1/8” (54mm), while
consuming an NSF-rated 100 U.S. gallons (379l) per hour.
Multiple-tank rackless conveyor model B-US 232 LPW shall have a maximum capacity of 13,200 dishes per hour at an
NSF-rated belt speed of 10 feet (3.0m) per minute, with minimum conveyor peg spacing of 2-1/8” (54mm), while
consuming an NSF-rated 121 U.S. gallons (458l) per hour.
Multiple-tank rackless conveyor model B-US 233 LPW shall have a maximum capacity of 15,840 dishes per hour at an
NSF-rated belt speed of 12 feet (3.7m) per minute, with minimum conveyor peg spacing of 2-1/8” (54mm), while
consuming an NSF-rated 137 U.S. gallons (519l) per hour.
Unit will have these optional features:
____ Meiko’s exclusive “Waste Air Heat Recovery System” which utilizes the heat generated by (and normally exhausted
from) the machine as free energy to preheat the incoming rinse water. In addition to saving energy, this feature
allows the use of incoming rinse water with temperatures as low as 50°F (10°C).
____ Meiko’s exclusive CSS Top (Chemical Savings System) - a dedicated pre-flushing system located prior to the
prewash that receives cooled water directly from the auxiliary rinse zone. CSS Top flushes food debris directly
from the ware and removes food soil by filtering the water through two cyclone separators. This reduces wash
water contamination, reducing detergent consumption by 50%.
NOTE: The CSS Top option is not available on Models B-US 231 and B-US 231 PW.
Unit will have the following size load end with CSS Top option:
____ 4’ 7-1/8” (1400mm) with 1’ 11-5/8” (600mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 5’ 6-7/8” (1700mm) with 2’ 11-3/8” (900mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 7’ 10-1/2” (2400mm) with 5’ 3” (1600mm) clear loading area and 3’ 1/4” (920mm) loading height
____ 8’ 10-3/8” (2700mm) with 6’ 2-3/4” (1900mm) clear loading area and 2’ 6-3/8” (770mm) loading height
____ 10’ 2” (3100mm) with 7’ 6-1/2” (2300mm) clear loading area and 2’ 6-3/8” (770mm) loading height
____ 11’ 5-3/4” (3500mm) with 8’ 10-3/8” (2700mm) clear loading area and 2’ 6-3/8” (770mm) loading height
____ A blower dryer option as described below:
____ Unit will have an unload end with a built-in single blower dryer for complete drying of all dishes, crockery
and silverware.
Blower dryer will be:
____ Steam-heated ____ Electrically heated
Blower dryer tunnel length will be:
____ 3’ 7-1/4” (1100mm). Length of unload end will be:
____ 6’ 2-3/4” (1900mm) with 2’ 7-1/2” (800mm) clear unloading area. NOTE: Available with
Model B-US 231 only.
____ 7’ 6-1/2” (2300mm) with 3’ 11-3/4” (1200mm) clear unloading area.
____ 8’ 6-3/8” (2600mm) with 4’ 11” (1500mm) clear unloading area.
____ 9’ 10-1/8” (3000mm) with 6’ 2-3/4” (1900mm) clear unloading area.
____ 10’ 9-7/8” (3300mm) with 7’ 2-5/8” (2200mm) clear unloading area.
____ 13’ 1-1/2” (4000mm) with 9’ 6-1/8” (2900mm) clear unloading area.
____ 16’ 7/8” (4900mm) with 12’ 5-5/8” (3800mm) clear unloading area.
____ 4’ 11” (1500mm). Length of unload end will be:
____ 7’ 6-1/2” (2300mm) with 2’ 7-1/2” (800mm) clear unloading area.
____ 8’ 6-3/8” (2600mm) with 3’ 7-1/4” (1100mm) clear unloading area.
____ 9’ 10-1/8” (3000mm) with 4’ 11” (1500mm) clear unloading area.
____ 10’ 9-7/8” (3300mm) with 5’ 10-7/8” (1800mm) clear unloading area.
____ 13’ 1-1/2” (4000mm) with 8’ 2-1/2” (2500mm) clear unloading area.
____ 16 7/8” (4900mm) with 11’ 1-7/8” (3400mm) clear unloading area.
____ 6’ 2-3/4” (1900mm). Length of unload end will be:
____ 9’ 10-1/8” (3000mm) with 3’ 7-1/4” (1100mm) clear unloading area.
____ 10’ 9-7/8” (3300mm) with 4’ 7-1/8” (1400mm) clear unloading area.
____ 13’ 1-1/2” (4000mm) with 6’ 10-5/8” (2100mm) clear unloading area.
____ 16’ 7/8” (4900mm) with 9’ 10-1/8” (3000mm) clear unloading area.
____ Unit will have an unload end with built-in dual blower dryers, incorporating low-humidity, low-temperature
drying, for complete drying of all plastics and trays, as well as all dishes, crockery and silverware.
Blower dryer will be:
____ Steam-heated ____ Electrically heated
Blower dryer tunnel length will be:
____ 6’ 7/8” (1850mm). Length of unload end will be:
____ 9’ 10-1/8” (3000mm) with 3’ 9-1/4” (1150mm) clear unloading area.
____ 10’ 9-7/8” (3300mm) with 4’ 9-1/8” (1450mm) clear unloading area.
____ 13’ 1-1/2” (4000mm) with 7’ 5/8” (2150mm) clear unloading area.
____ 16’ 7/8” (4900mm) with 10’ 1/8” (3050mm) clear unloading area.
____ 7’ 6-1/2” (2300mm). Length of unload end will be:
____ 10’ 9-7/8” (3300mm) with 3’ 3-3/8” (1000mm) clear unloading area.
____ 13’ 1-1/2” (4000mm) with 5’ 6-7/8” (1700mm) clear unloading area.
____ 16’ 7/8” (4900mm) with 8’ 6-3/8” (2600mm) clear unloading area.
____ 8’ 10-3/8” (2700mm). Length of unload end will be:
____ 13’ 1-1/2” (4000mm) with 4’ 3-1/8” (1300mm) clear unloading area.
____ 16’ 7/8” (4900mm) with 7’ 2-5/8” (2200mm) clear unloading area.
____ 10’ 2” (3100mm). Length of unload end will be:
____ 131-1/2” (4000mm) with 2’ 11-3/8” (900mm) clear unloading area.
____ 16’ 7/8” (4900mm) with 5’ 10-7/8” (1800mm) clear unloading area.
____ A factory-installed external fan control option as described below:
____ One contactor for controlling an external fan. Replaces one set of potential free contacts (see Standard
Features). Maximum 600VAC, 35A, 3 Ph.
____ Two contactors for controlling external fan(s). Replaces both sets of potential free contacts (see Standard
Features). Maximum 600VAC, 35A, 3 Ph.
Note: Consult the factory for more options, systems and accessories. Some available items include:
Low ceiling height option.
Special conveyor belt and peg configurations for a variety of ware and flexibility.
Conveyor belt with a cutlery track combined with special wash arms to provide pristine results for all flatware.
Lateral wash arm systems for machines primarily intended to wash partitioned, compartmentalized, or insulated trays.
Complete customized systems consisting of soiled and clean ware conveyors to transport trays and loose ware to and
from the dishmachine as well as accumulators, stackers, etc.
B-US 23 Series • Updated 11-04 Meiko • 917 Airpark Center Drive • Nashville, TN 37217 • (800) 55-MEIKO • FAX (615) 399-6620 • www.meiko.us
Meiko’s flight conveyors use
double stainless steel walls, with
a layer of insulation between them.
This keeps heat inside the
machine, reducing energy
consumption while improving the
working environment by reducing
noise and heat dissipation into the
dishroom.
Prewash and wash arms are assembled into easily-removed
block manifolds, simplifying cleaning. The arms are also fitted
with tethered (or “captivated”) end caps to prevent their loss
during cleaning. Large, front-sloping stainless steel scrap screens
are easily removed for cleaning.
Now you have a choice!
Compare, and the
choice is obvious!
Meiko’s optional Waste Air Heat
Recovery System uses the waste
heat generated by the machine to
pre-heat the incoming rinse water.
In addition to saving energy, the
system allows the use of incoming
water as cool as 50°F/10°C!
Meiko’s flight conveyors have a pumped final
rinse to eliminate pressure fluctuations and
ensure consistent, pristine results.
Used rinse water, instead of cascading directly
into the wash tank, is regenerated and diverted
to a pumped, heated auxiliary rinse.
Water and chemical consumption can be significant long-term expenses
when operating a warewasher. Meiko’s B-US Series has the lowest water
consumption rate in the industry. Our exclusive CSS (Chemical Savings
System) reduces detergent consumption by 30%-50%.
Note: All specifications are subject to change without notice
based on Meiko’s dedicated product improvement program.
/