Split System Submittal Data
System: KE36NKU Indoor: CS-KE36NKU Outdoor: CU-36NKU
Wall Mounted Heat Pump
Approval:
Date:
Construction:
Unit#:
Drawing#:
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz) 230/208/1/60
Circuit Ampacity (A) 16.5-18.0
Fuse Size, Max.(A) 45
Compressor DC Twin Rotary (Inverter)
No. Used 1
R.L. Amps - L.R. (A) 20.0-31.0
Outdoor Unit
Fan Type Propeller
Dia (in.) - No. Speeds 19-9/32” Auto (Hi, Me, Lo)
Type Drive Direct / DC Motor
No. Poles (RPM) 8-750
No. Motors (W) 1-142
F.L. Amps (A) 19.6-21.5
Coil Type Aluminum Fin and Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 2-21.2
Rows - F.P.I. 2 - 18.1
Face Area (sq.ft.) 8.05
Tube Size (in.) 3/8”
Indoor Unit
Fan Type Cross Flow
Dia (in.) 3-15/16” x 32”
No. Speeds Auto and 3 steps
No. Poles (RPM (Cool / Heat), High) 8-1,370 / 1,450
No. Motors (W) 47
CFM (Hi/Med/Low) Cooling 630/530/412
CFM (Hi/Med/Low) Heating 671/559/441
Operating Sound-Hi/Me/Lo/ dB-A
(Cool)
49 / 44 / 39
Operating Sound-Hi/Me/Lo/ dB-A
(Heat)
49 / 44 / 39
F.L. Amps 0.4
Coil Type
Aluminum Plate Fin & Copper Tube
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 2-19.5
Face Area (sq. ft.) 4.55
Tube Size (in.) 3/8”
Drain Connection Size (in.) 1-1/4”
Refrigerant R410A
Lbs. - R410a (outdoor unit) 6.5
Refrigerant Control Electronic Expansion Valve
Refrigerant Tubing Connections Flare
Line Length, Max (ft.) 165
Line Difference, Max (ft.) 50 (outdoor lower), 100 (outdoor
higher)
Line Size (in. O.D. Discharge) 3/8”
Line Size (in. O.D. Suction) 5/8”
Pre-charge, tubing length at
shipment
100’
Dimensions (HxWxD)
Indoor Unit (Crated) (in.) 12-7/32 x 44-7/8 x 14-31/32
Indoor Unit (Uncrated) (in.) 11-3/16 x 41-15/16 x 9-1/16
Outdoor Unit (Crated) (in.) 42-3/8 x 40 x 16-3/8
Outdoor Unit (Uncrated) (in.) 35-13/16 x 37-1/32 x 13-3/8
Weight (lbs.)
(Indoor) Net 32.0
(Indoor) Shipping 39.7
(Outdoor) Net 185.2
(Outdoor) Shipping 207.2
(Indoor) Shipping Volume (cu.ft.) 4.59
(Outdoor) Shipping Volume (cu.ft.) 15.88
Features
Controls Microprocessor
Remote Controller LCD Wireless Type, Temp. Sensor
Built In
Temperature Control IC Thermistor
Timer 24 Hour, Single Event, ON/OFF
TIMER
Night Setback Included
Unoccupied Mode Included
High Power Included
One Hour Timer Included
Options
Refrigerant Line Set Available
Fresh Air Intake N/A
Airduct Extension N/A
Hard Wired Remote Control Available / Model Number-CZ-
RD515U
Indoor Frame Extension N/A
Condensate Drain Pump Available
Non-Removable, Locking
Remote-Control Bracket
Available
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67F DB/57F WB 0F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 0F DB
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity (BTU/H) 34,000 (10,900-34,000)
Sensible Capacity (BTU/H) 20,700
Latent Capacity (BTU/H) 13,300
SEER 16
Dehumidification (Pints/H) 10.64
Amps (A) 5-21.9
Power Inputs (W) 4,000
Outdoor Sound Rating (dB-A) 55
Heating
Total Capacity (BTU/H) 36,000 (14,000-36,000)
HSPF 9,0
Amps (A) 5-21.9
Max Amps 18.2/19.9
Power Inputs (W) 3,650/3,650
Outdoor Sounds Rating (dB-A) 56
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Air Louver, Horizontal Manual
Air Louver, Vertical Automatic,Sweep,Step
Power Failure Automatic Restart Included
Heating/Cooling Automatic
Changeover
Included
Self-Diagnosis Included
Air Filter Washable, Anti-Mold
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Indoor Dimensions
Outdoor Dimensions
6-11/6 25-31/32
4-11/32
2-15/16
2-3/8
2-ID:1-1/4 holes (holes for drain)
Of the 4-ID:1-1/4 holes, use 1 of 2 holes
specified for drain use to install the port.
Use rubber plugs to seal the remaining 3 holes.
1/2
1/2
2-15/168-5/8
4-1/8
37-1/32 (940)
Refrigerant tubing joint (Liquid tube)
Flare connection dia.3/8" (9.52)
Refrigerant tubing joint (Gas tube)
Flare connection dia.5/8" (15.88)
2-3/8
3/4
1-15/16
1-27/32
1-3/16
4-11/32
13-9/32
14-11/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
2-25/32
2-5/32
2-17/32
35-13/16 (910)
23/32
1-1/32
13/32
13-3/8 (340)
14-31/32
16-5/32
11-13/32
4-11/32
2-25/32
1-15/16
6-23/32 19/32
31/32
4-3/4
1-3/16
7/16
2-5/32
21/32
1-27/32
1-3/16
2-3/8
3/4
3-3/8
2-17/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
6-11/6 25-31/32
4-11/32
2-15/16
2-3/8
2-ID:1-1/4 holes (holes for drain)
Of the 4-ID:1-1/4 holes, use 1 of 2 holes
specified for drain use to install the port.
Use rubber plugs to seal the remaining 3 holes.
1/2
1/2
2-15/168-5/8
4-1/8
37-1/32 (940)
Refrigerant tubing joint (Liquid tube)
Flare connection dia.3/8" (9.52)
Refrigerant tubing joint (Gas tube)
Flare connection dia.5/8" (15.88)
2-3/8
3/4
1-15/16
1-27/32
1-3/16
4-11/32
13-9/32
14-11/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
2-25/32
2-5/32
2-17/32
35-13/16 (910)
23/32
1-1/32
13/32
13-3/8 (340)
14-31/32
16-5/32
11-13/32
4-11/32
2-25/32
1-15/16
6-23/32 19/32
31/32
4-3/4
1-3/16
7/16
2-5/32
21/32
1-27/32
1-3/16
2-3/8
3/4
3-3/8
2-17/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
41-15/16 (1065)
9-1/16 (230) (3/32)
7-25/32
Wide tube dia. 5/8" (15.88)
Narrow tube dia. 3/8" (9.52)
1-27/32 1-3/32
23/5223/3-2
5-1/2
6-7/32
16-11/32
17-5/16
19-9/16
16-11/32
17-21/32
22-3/8
5-3/16
8/7-74/3-34/3-3
23/32-718/1-51
2-11/16
11-13/16
1-7/8
dia. 3-5/32
23/32
1-15/32
1-7/8
9-3/32
5-27/32
2-3/8
4-9/16
4-9/16
11-13/16 (300)
7-23/32
2-3/4
5-9/16
1-9/32
7/16
2-5/8
2-3/8
3-3/8
2-5/8
dia. 3-5/32
  • Page 1 1
  • Page 2 2
  • Page 3 3

Panasonic KE36NKUA User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI