Sanyo KMHS0772 User manual

Category
Split-system air conditioners
Type
User manual
KMHS0772
Wall Mounted Indoor Unit - Multi Heat Pump
Power V/P/Hz 230/1/60
Circuit Ampacity
Fuse Size, Max.
Running Amps
Power Input
Indoor Unit Cool/Heat
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Operation Sound
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Refrigerant
Line Size
Line Size
Dimensions
Indoor Unit
Weight
Net Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Moisture Removal (HI)
Heating
Total Capacity
Feature
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Heating/Cooling Automatic Changeover
Self-Diagnosis
Quiet Operation
Air Filter
Ion Generator
Air Clean Apatite Filer
(A) 15
(A) 20
General Data (at 230V)
(W) 25
Cross Flow
D3-11/16 L24-31/32-1
3 & Auto
(RPM, High) 8 - 1050/1100
(W) 1 - 47
(BTU/H) 7,500
(Pint/H) 2.77
(Uncrated) 11-7/32 x 32-15/32 x 7-7/16
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffl ed
(in.) 9/32”
Multi/Split System Submittal Data
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
2 - 19.5
(sq.ft.) 2.02
(lbs.) 19.8
(in. O.D. Discharge) 1/4”(Flare)
(in. O.D. Discharge) 3/8”(Flare)
(A) .11
(HI) 241/271
(HI/Med/Lo/QT* dB-A) 33/30/27/23
(in.) 23/32”
(in.) H x W x D
(Crated) 13-25/32 x 35-7/16 x 10-1/32
Indoor
(cu.ft.) 2.82
Indoor
(lbs.) 24.3
Microprocessor
LCD Wireless Type, Temp. Sensor Built In
(Horizontal) Manual
24 Hr. Program, 1 Hr. Off
IC Thermostat
Built-In
Built-In
-
Standard
Built-In
Built-In
Equipped
R410a
(Vertical) Automatic
Washable, Anti-Mold
(BTU/H) 8,500
Print Form
Dimensions
Option
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removeable Remo-con Bracket
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
(CMH Model)
Heating
(CMH Model)
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 67F DB
Available
N/A
N/A
N/A
Available
Available
Maximum 80F DB/67F WB 75F DB/65F WB
Minimum -DB/-WB 0 DB