Panasonic CS-KE18NB4U is a ceiling-recessed multi-system indoor unit with a range of features that ensure efficient and comfortable climate control in your space. With its turbo fan mode, it quickly cools or heats your room, providing rapid relief from extreme temperatures. The unit's quiet operation ensures minimal disturbance, making it suitable for both residential and commercial applications. The built-in self-diagnosis function helps identify any potential issues, ensuring timely maintenance and preventing unexpected breakdowns.

Panasonic CS-KE18NB4U is a ceiling-recessed multi-system indoor unit with a range of features that ensure efficient and comfortable climate control in your space. With its turbo fan mode, it quickly cools or heats your room, providing rapid relief from extreme temperatures. The unit's quiet operation ensures minimal disturbance, making it suitable for both residential and commercial applications. The built-in self-diagnosis function helps identify any potential issues, ensuring timely maintenance and preventing unexpected breakdowns.

Split System Submittal Data
Indoor: CS-KE18NB4UW
Multi System Indoor Units - Ceiling Recessed
Approval:
Date:
Construction:
Unit#:
Drawing#:
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz) 208 - 230/1/60
Circuit Ampacity (A) N/A
Fuse Size, Max.(A) 15
Running Amps (A) (COOL) .16 / .15 (HEAT) .2 / .19
Power Input (W) (COOL) 22 / 22 (HEAT) 27 / 27
Indoor Unit Cool/Heat
Fan type Turbo
Dia & Length (in.) - No. Speeds D12-5/8 L5-3/4 x 1
No. Speeds 3 & Auto
No. Poles (RPM, High) 8 - 650/720
No. Motors (W) 1-(20)
CFM (HI) 341/383
Operation Sound (HI/Med/Lo)
dB-A
44/40/36
Coil Type Aluminum Plate Fin & Copper
Tube
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 2 - 18.1
Face Area (sq.ft.) 2.94
Tube Size (in) N/A
Drain Connection Size 3/4
Refrigerant R410A
Line Size (in. O.D. Discharge) 1/4” (Flare)
Line Size (in. O.D. Suction) 1/2” (Flare)
Dimensions (HxWxD)
Indoor Unit (Crated) (in.) 11-13/32 x 24-13/16 x 28-1/8
Indoor Unit (Uncrated) (in.) 12-5/16 x 24-19/32 x 24-19/32
Weight (lbs.)
Net, Indoor (lbs.) 35.3
Shipping, Indoor (lbs.) 41.9
Shipping Volume (cu.ft.) 4.59
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity (BTU/H) 17,500
Moisture Removal (HI, Pint/H) 4.89
Features
Controls Microprocessor
Remote Control LCD Wireless Type, Temp. Sensor
Built In
Temperature Control IC Thermostat
Timer 24 Hr. Program, 1 Hr. Off
Night Setback Built-In
Air Louver Automatic
Power Failure Automatic Restart Built-In
Self-Diagnosis Built-In
Quiet Operation Built-In
Air Filter Washable, Anti-Mold
Dimensions
Option
Refrigerant Line Set Available
Fresh Air Intake Knock-out
Airduct Extension N/A
Condensate Drain Pump Standard
Hard Wired Remote Controller Available
Non-Removeable Remo-con
Bracket
Available
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67 DB/57F WB 14F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 0F DB
Heating
Total Capacity (BTU/H) 20,400
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Indoor Dimensions
3. DIMENSIONAL DATA
Indoor Unit CS-KS12NB41 & CZ-18BT1U
CS-KS18NB4UW & CZ-18BT1U
6-5/16 6-11/16
1-3/16 (30)
4-19/32
1-25/32
1-25/32
2-3/32
8-15/32
22-5/8 (575)
11-5/32 (283)
3
6
5
Less than 31/32 Less than 31/32
3-5/8
22-5/8 (575)
12-7/8
Suspension bolt pitch
Suspension bolt pitch
21-1/32 (534)
21-1/32
(534)
12-7/16
23-5/8 (600)
Ceiling opening dimensions
23-5/8 (600)
Ceiling opening dimensions
7
Center of
panel
24-19/32 (625)
24-19/32 (625)
13-5/32 (334)
14-3/32 (358)
1
2
2
2
2
7-11/16
4-29/32
A View
8
1-3/16
21/32
3-1/8
The length of the suspension
bolts should be selected so that
there is a gap of 1-3/16" or
the ceiling (21/32" or more
below the lower surface of the
main unit), as shown in the
figure at right. If the suspension
bolts is too long, it will contact
the ceiling panel and the unit
cannot be installed.
AA
Air intake
Discharge outlet
Refrigerant tubing
(liquid tube)
dia.
1/4" (flared)
Refrigerant tubing
(gas tube)
dia. 1/2"
(flared)
Drain tube connection port VP20 (outer dia. 1")
Power supply port
Suspension bolt hole (4 - 1/2" x 1-1/8" hole)
Fresh air intake duct connection port (dia. 3-7/8")
1
2
3
4
5
6
7
8
7-23/32
1-27/32 1-3/32
2-3/32
2-3/4 1-9/32
5-9/16
25/32
Unit : inch (mm)
23
  • Page 1 1
  • Page 2 2

Panasonic CS-KE18NB4U Datasheet

Type
Datasheet
This manual is also suitable for

Panasonic CS-KE18NB4U is a ceiling-recessed multi-system indoor unit with a range of features that ensure efficient and comfortable climate control in your space. With its turbo fan mode, it quickly cools or heats your room, providing rapid relief from extreme temperatures. The unit's quiet operation ensures minimal disturbance, making it suitable for both residential and commercial applications. The built-in self-diagnosis function helps identify any potential issues, ensuring timely maintenance and preventing unexpected breakdowns.