Radiant iMODULE User manual

Type
User manual

Radiant iMODULE lets you manage your heating system conveniently via your smartphone or tablet, using the iMODULE app. Its intuitive and user-friendly interface provides remote control over your heating system, allowing you to adjust temperatures, set schedules, and monitor energy consumption. With iMODULE, you can create personalized heating profiles that adapt to your daily routine, ensuring maximum comfort and energy efficiency. Whether you're at home or away, you'll have complete control over your heating system at your fingertips.

Radiant iMODULE lets you manage your heating system conveniently via your smartphone or tablet, using the iMODULE app. Its intuitive and user-friendly interface provides remote control over your heating system, allowing you to adjust temperatures, set schedules, and monitor energy consumption. With iMODULE, you can create personalized heating profiles that adapt to your daily routine, ensuring maximum comfort and energy efficiency. Whether you're at home or away, you'll have complete control over your heating system at your fingertips.

iMODULE - RAD - ING - Manuale - 1507.1
User's manual
iMODULE
Remote Control via Wi-Fi or GSM
2
iMODULE - RAD - ING - Manuale - 1507.1
iMODULE_EN
TABLE OF CONTENTS
TABLE OF CONTENTS
1. INSTALLER SECTION 3
1.0.1. INSTALLER REGISTRATION 4
1.0.2. REGISTERING A NEW USER 4
1.0.3. HOW TO CONFIGURE THE PARAMETERS OF THE NEW UNIT 5
1.0.4. WIRING 7
1.0.5. CONFIGURATION OF IMODULE GSM VERSION 9
1.0.6. CONFIGURATION OF IMODULE WI-FI VERSION 10
2. USER SECTION 11
2.0.1. APP IMODULE 12
2.0.2. LOCAL-CONTROLLER 13
2.0.3. RECEIVER IMODULE 14
The operations of installation, described in this section,
must be performed by qualified personnel only, who has
technical expertise in the field required to installation and
maintenance of the parts of the heating and DHW production
systems for civil and industrial buildings as provided in Art.
3 of Min. Decree no. 37 dated 22.01.2008.
1. INSTALLER SECTION
4
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
1.0.1. INSTALLER REGISTRATION
Open the page ‘http://www.imodule.it/’;
Click on “Registration Form”;
Type in the page the following data:
· Installer's Name;
· Installer's Surname;
· Installer's Email Address;
· Choose a password;
· Installer's Address;
· Installer's mobile phone number (with
international dialling code);
· Country;
· VAT number (11 characters);
· Captcha code.
Press "Send".
To confirm the registration, the installer must
click on the link received by email;
after confirmation, the installer receives a second
email with a summary of login credentials and an
attachment with the instructions for accessing
the technical panel of the iModule APP.
1.0.2. REGISTERING A NEW USER
Open the page ‘http://app.imodule.it/admin’;
Enter the installer login credentials and click on
"Login".
The list of registered users (if any) will be
displayed.
To add a new User click on “New User/Boiler”.
Enter the information regarding the new iModule
unit to register:
· UserName and Password (that will be used by
the user to log in to iMODULE APP);
· Name and Surname of system/iModule owner;
· Serial number of the iModule (without the
zeros before the digit, for a serial number
00000168 you will write 168); the serial number
is specified in the iModule unit, on the label
above connector 'A' and below connector 'C'
(see fig. 3 in chapter 'WIRING' );
· the phone number of the SIM card inserted in
the iModule (only for iModule in GSM version);
· the place (province) of the iModule unit.
Once you have entered the data, click on “Save”.
Return to the home page, in the list of users,
where is displayed the new iModule registered.
INSTALLATION
5
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
1.0.3. HOW TO CONFIGURE THE PARAMETERS OF THE NEW UNIT
To configure the parameters of the new unit click on the adjustable spanner icon (see fig. 1).
fig. 1
fig. 2
6
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
OPEN-THERM PROTOCOL CONFIGURATION
Use the parameter “OT Protocol version” (see fig.2)
to configure the iModule based on the version of
the Open-Therm Protocol used by the boiler:
0 = for boilers with electronic printed circuit
board NORDGAS;
1 = for boilers with electronic printed circuit
board HONEYWELL;
2 = non applicable.
CONFIGURATION OF STANDARD/DST TIME
You can switch from standard time to daylight
saving time (and vice versa), using the parameter
"DST change" (see figure 2) and modify the time of
the iModule by one hour, according to the following
convention:
0 = no change to current iModule time;
1 = add one hour to current iModule time;
255 = remove one hour from current iModule
time.
TIME ZONE CONFIGURATION
You can manage all of the time zones from -12
hours to +14 hours, in relation to UTC coordinated
universal time, with a resolution of half an hour.
The time zone of the iModule is set using the
parameter "Time Zone" (see fig.2), within its his
range [104÷156], according to the following rule:
· value of parameter “Time Zone” = 128 +
difference of iModule time in relation to UTC
time, multiplied by 2.
Examples of Time Zones:
UTC Time (Time Zone 0) = set “Time Zone” = 128;
Western Europe Time (Time one 1) = set "Time
Zone" = 130;
India Time (Time Zone +5.5) = set “Time Zone” =
139;
Examples by City:
Paris/Rome = UTC Time + 1 = set “Time Zone” =
130;
London = UTC Time = set “Time Zone” = 128;
Moscow = UTC Time + 3 = set “Time Zone” = 134;
Kiev = UTC Time +2 = set “Time Zone” = 132;
Tehran = UTC Time +3.5 = set “Time Zone” = 135.
OPEN-THERM (OT) CONFIGURATION OR ROOM
THERMOSTAT (RT)
For iModule systems connected to Open-Therm
boilers (configuration–OT), set the parameter
“Connection Type (OT/RT)” = 0;
For iModule systems connected to Room
Thermostat boilers (configuration–RT), set the
parameter “Connection Type (OT/RT)” = 1;
7
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
1.0.4. WIRING
Install the Local-Controller within the home, for
example in the same position as the previous
programmable thermostat/remote controller.
Install the iModule in any place inside the house
(house, cellar, boiler room, under the stairs… ), with
a good GSM signal (for iModule in GSM version)
or in the vicinity of the WI-FI Router/Switch (for
iModule in Wi-Fi version);
Once you have installed the Local-Controller and
the iModule, carry out the following electrical
connections (see fig.3):
· Open-Therm connection between iModule
and Local-Controller (2 wires);
· Connection between the iModule and the
Boiler (2 wires) via Open-Therm or Room
Thermostat Relay;
· iModule connection to the power supply
network (230VAC).
KEY
Connector A (Power supply):
· N - Neutral point of power cord (mains voltage
230 VAC, 50 Hz);
· L - Phase of power cord (mains voltage 230
VAC, 50 Hz);
· G - Grounding point of power cord (mains
voltage 230 VAC, 50 Hz);
Connector B (for Room Thermostat versions only):
· T1 and T2 should be connected to the boiler
to activate the heating request via the Room
Thermostat relay.
Connector C (Open-Therm connections):
· B1 and B2 should be connected to Open-
Therm bus of the boiler (only for boilers with
Open-Therm configuration);
· R1 and R2 should be connected to the Local
Controller.
fig. 3
8
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
WIRING DIAGRAM OF OPENTHERM BOILER
WIRING DIAGRAM OF ROOM THERMOSTAT BOILER
fig. 4
fig. 5
9
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
1.0.5. CONFIGURATION OF IMODULE GSM VERSION
WARNING
Use only SIM card “2G” type “DATA” or “OPTION + DATA” (the SIM cards “3G” are not supported like
in the case of telephone provider TRE).
To insert the SIM card into the iModule see fig.6.
Send an SMS to the telephone number associated to the SIM card inserted in the iModule with the following
format:
APN:xxx# (instead of ‘xxx’ insert the APN of the operator of the SIM card inserted in the iModule).
Below are some examples of APN for Italian operators:
TIM = ibox.tim.it
VODAFONE = mobile.vodafone.it
WIND = internet.wind
Example of SMS to send to the iModule:
APN:internet.wind#
fig. 6
10
iMODULE - RAD - ING - Manuale - 1507.1
1 Installazione_iMODULE_v.1502_EN
2. INSTALLATION
INSTALLER
1.0.6. CONFIGURATION OF IMODULE
WI-FI VERSION
Power the iModule unit (via connector A, see fig.3 in
chapter ‘WIRING’);
a Wi-Fi network called “iModule_WiFi” will be
activated for 10 minutes; the network can be
accessed without password;
Connect a Wi-Fi device (PC/Laptop/Tablet/
Smartphone) to “iModule_WiFi” network;
Open a Web-Browser in the Wi-Fi device
(recommended Browsers: Internet Explorer
©
,
Mozilla Firefox
©
, Safari
©
) and select the web page:
http://captiveportal.net;
If the web page ‘http://captiveportal.net’ does not
open promptly, we suggest you disable the Proxy
server, where applicable (check the connection
options or browser settings);
Enter the data requested in the following fields
(fig.7):
Insert miniAP PassKey: nordgas
Insert the SSID: name of Wi-Fi network to which
the iModule will connect
Insert the PSK: name of Wi-Fi network to which
the iModule will connect
Ignor the following 4 fields “Insert Static IP
Address”, “Insert Static NetMask”, “Insert Static
GW Address” and “Insert Static DNS Address”
Turn on/off DNS/DHCP: select “ON”
Choose Auth Type: select “Open System”
Choose Auth: select one of the following options
based on the safety protocol of the Wi-Fi network
to which the device will connect:
· “WPA/WPA2” (with password);
· “WEP” (with password);
· “Open” (without password) for free Wi-Fi
networks;
Choose Mode: select Station;
Finally, press Press “GO!”.
After a few seconds, the “iModule_WiFi” network
is disabled by the iModule unit via the dedicated
automatic disable function of the Wi-Fi device;
On the APP iModule, wait for max 3/5 minutes and
check that the room temperature displayed was
updated.
NOTE: should it be necessary to repeat the Wi-
Fi setup (for example when you need to change
one or more parameters of the Wi-Fi network to
connect), cut off power to the iModule and repeat
the configuration procedure.
fig. 7
the operations described in this section are addressed to
all those who will use the machine. The machine must be
used and accessed only by qualified operators that fully
read and understood the User section, paying particular
attention to the warnings.
2. USER SECTION
12
iMODULE - RAD - ING - Manuale - 1507.1
3 APP iMODULE_EN
2. USE
USER
The iModule consists of:
APP iMODULE installed on Smartphone and
Tablet;
Local-Controller (with room temperature
sensor);
Receiver iModule (in GSM or Wi-Fi version).
2.0.1. APP IMODULE
The APP iMODULE allows you to control the boiler
connected to the Receiver iModule via your personal
electronic device (Tablet and Smartphone).
Download the APP iMODULE for iOS (Apple iPhone/
iPad) and Android for free easily, by scanning the
QR (quick response) code below:
Or find the APP “iMODULE” directly in:
· App Store for iOS (Apple iPhone/iPad)
· Google Play for Android.
Once you have installed the APP iMODULE you can
access the DEMO version (username and password
not required), to test the interface and the control
logic of the system without being connected to any
real system.
Log in using the credentials provided by the
Installer of you unit.
In he login page, you can select the application
language from the following:
· English
· Italian
· Czech
· Polish
· Russian
· Ukrainian
You can also use the APP iMODULE from the
browser entering the access credentials in the
web page ‘http://app.imodule.it/home’. For quick
access, scan the QR (quick response) code below:
USE
13
iMODULE - RAD - ING - Manuale - 1507.1
3 Local-Controller_EN
3 Local-Controller_EN
2. USE
USER
2.0.2. LOCAL-CONTROLLER
The Local–Controller unit is equipped with a sensor
that measures the room temperature displayed on
the APP iMODULE.
The Local–Controller allows the User to set, in
MANUAL mode, the desired room temperature
using the adjustment dial.
KEY OF USER INTERFACE (SEE FIG.1)
1. Dial: used to set the room temperature within
the range from 10°C to 30°C, valid fro MANUAL
mode only;
2. Green LED:
· Steadily Lit: MANUAL mode enabled (boiler
controlled by the Local-Controller).
· Flashing Slowly: AUTOMATIC mode enabled
(boiler controlled by the APP iMODULE).
· Flashing Quickly: MANUAL mode enabled
(power has been cut off to Receiver iModul,
the boiler is controlled directly by the Local-
Controller);
3. Push button: hold it down for three seconds
to switch from AUTOMATIC to MANUAL mode
and vice versa;
4. Red LED:
· Steadily Lit: failed communication between
Open-Therm amd Receiver iModule or boiler;
· LED off: no failure;
· Flashing Slowly: Room sensor failure (on
Local-Controller);
· Flashing Quckly: Receiver iModule failure (no
communication to APP iModule).
·
USE
fig. 1
14
iMODULE - RAD - ING - Manuale - 1507.1
3 iModule Ricevitore_EN
2. USE
USER
2.0.3. RECEIVER IMODULE
The Receiver iModule enables, in AUTOMATIC
mode, exchanging data between the boiler and your
personal electronic device (Tablet and Smartphone)
controlled by the APP iMODULE.
KEY OF LED USER INTERFACE ‘1’ (FIG.1)
Green LED Steadily Lit: AUTOMATIC mode
enabled (boiler controlled by the APP iMODULE).
Alternating Red and Green Flashing LED: the
system is not configured (for WI-FI version,
configure the WI-FI network to connect; for GSM
version send an SMS to configure the APN).
Green Slow Flashing LED (1 flash every 2.5
seconds): MANUAL mode enabled, boiler
controlled by Local-Controller.
Green Slow Flashing LED (1 flash every second):
GSM/Wi-Fi communication in progress.
Green Quick Flashing LED (5 flashes every
second): Wi-Fi communication (mini access-
point) in progress.
Red Steadily Lit LED: GSM/Wi-Fi communication
failure.
Red Slow Flashing LED (1 flash every second):
Local-Controller communication failure.
Red Quick Flashing LED (5 flash every second):
boiler communication failure (if configured as
Open-Therm).
LED off: iModule not powered.
If power has been cut off to Receiver iModul, the
boiler is controlled directly by the Local-Controller
in MANUAL mode.
USE
fig. 1
RADIANT BRUCIATORI S.p.A.
Via Pantanelli, 164/166 - 61025 - Montelabbate (PU)
Tel. +39 0721 9079.1 • fax. +39 0721 9079279
e-mail: info@radiant • http://www.radiant.it
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Radiant iMODULE User manual

Type
User manual

Radiant iMODULE lets you manage your heating system conveniently via your smartphone or tablet, using the iMODULE app. Its intuitive and user-friendly interface provides remote control over your heating system, allowing you to adjust temperatures, set schedules, and monitor energy consumption. With iMODULE, you can create personalized heating profiles that adapt to your daily routine, ensuring maximum comfort and energy efficiency. Whether you're at home or away, you'll have complete control over your heating system at your fingertips.