Harris Maxiva ULX Technical Manual

  • Hello! I am an AI chatbot trained to assist you with the Harris Maxiva ULX Technical Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Maxiva ULX COFDM
Series Digital Transmitter
This manual applies to the following modulation types:
DVB-T/H
ISDB-T/H
FLO
CTTB
CMMB
TECHNICAL MANUAL
888-2629-200
Maxiva ULX COFDM Series
Digital Transmitter
Oct. 5, 2010
Rev: B
T.M. No. 888-2629-200
© Copyright Harris Corporation 2010
All rights reserved
ii 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
10/6/10 888-2629-200 iii
WARNING: Disconnect primary power prior to servicing.
Technical Assistance
Technical and troubleshooting assistance for HARRIS Transmission products is available from
HARRIS Field Service (factory location: Quincy, Illinois, USA) during normal business hours (8:00
AM - 5:00 PM Central Time). Telephone +1-217-222-8200 to contact the Field Service Department;
FAX +1-217-221-7086; or E-mail questions to [email protected].
Emergency service is available 24 hours a day, seven days a week, by telephone only.
Online assistance, including technical manuals, white papers, software downloads, and service
bulletins, is available at http://support.broadcast.harris.com/eservice_enu.
Address written correspondence to Field Service Department, HARRIS Broadcast Communications
Division, P.O. Box 4290, Quincy, Illinois 62305-4290, USA. For other global service contact
information, please visit: http://www.broadcast.harris.com/contact.
NOTE: For all service and parts correspondence, you will need to provide the Sales Order number, as
well as the Serial Number for the transmitter or part in question. For future reference, record those
numbers here: ___________________/____________________
Please provide these numbers for any written request, or have these numbers ready in the event you
choose to call regarding any Service, or Parts requests. For warranty claims it will be required, and for
out of warranty products, this will help us to best identify what specific hardware was shipped.
Replaceable Parts Service
Replacement parts are available from HARRIS Service Parts Department 7:00 AM to 7:00 PM
Central Time, Monday through Friday, and 8:00 AM to 1:00 PM Central Time on Saturday.
Telephone +1-217-222-8200 or email [email protected] to contact the Service Parts Dept.
Emergency replacement parts are available by telephone only, 24 hours a day, seven days a week
by calling +1-217-222-8200.
Unpacking
Carefully unpack the equipment and perform a visual inspection to determine if any apparent damage
was incurred during shipment. Retain the shipping materials until it has been verified that all
equipment has been received undamaged. Locate and retain all PACKING CHECK LISTs. Use the
PACKING CHECK LIST to help locate and identify any components or assemblies which are
removed for shipping and must be reinstalled. Also remove any shipping supports, straps, and
packing materials prior to initial turn on.
Returns And Exchanges
No equipment can be returned unless written approval and a Return Authorization is received from
HARRIS Broadcast Communications Division. Special shipping instructions and coding will be
provided to assure proper handling. Complete details regarding circumstances and reasons for return
are to be included in the request for return. Custom equipment or special order equipment is not
returnable. In those instances where return or exchange of equipment is at the request of the customer,
or convenience of the customer, a restocking fee will be charged. All returns will be sent freight
prepaid and properly insured by the customer. When communicating with HARRIS Broadcast
Communications Division, specify the HARRIS Order Number or Invoice Number
iv 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
10/6/10 888-2629-200 MRH-1
WARNING: Disconnect primary power prior to servicing.
Manual Revision History
Maxiva ULX COFDM Series Digital Transmitter Manual
REV. DATE ECN Pages Affected
A 2010 Mar 15 Created
B 2010 Oct 5 59529 Update multiple sections. Corrected PS numbering in Sec. 5
MRH-2 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
10/6/10 888-2629-200 vii
WARNING: Disconnect primary power prior to servicing.
Guide to Using Harris Parts List Information
The Harris Replaceable Parts List Index portrays a tree structure with the major items being leftmost in the index.
The example below shows the Transmitter as the highest item in the tree structure. If you were to look at the bill
of materials table for the Transmitter you would find the Control Cabinet, the PA Cabinet, and the Output
Cabinet. In the Replaceable Parts List Index the Control Cabinet, PA Cabinet, and Output Cabinet show up one
indentation level below the Transmitter and implies that they are used in the Transmitter. The Controller Board is
indented one level below the Control Cabinet so it will show up in the bill of material for the Control Cabinet.
The tree structure of this same index is shown to the right of the table and shows indentation level versus tree
structure level.
Example of Replaceable Parts List Index and equivalent tree structure:
Replaceable Parts List Index Part Number Page
Table 7-1. Transmitter 994 9283 001 7-2
Table 7-2. Control Cabinet 992 9244 002 7-3
Table 7-3. Controller Board 992 8344 002 7-6
Table 7-4. PA Cabinet 992 9400 002 7-7
Table 7-5. PA Amplifier 994 7894 002 7-9
Table 7-6. PA Amplifier Board 992 7904 002 7-10
Table 7-7. Output Cabinet 992 9450 001 7-12
The part number of the item is shown to the right of the description as is the page in the manual where the bill for
that part number starts. Inside the actual tables, four main headings are used:
Table #-#. ITEM NAME - HARRIS PART NUMBER - this line gives the information that corresponds
to the Replaceable Parts List Index entry;
HARRIS P/N column gives the ten digit Harris part number (usually in ascending order);
DESCRIPTION column gives a 25 character or less description of the part number;
REF. SYMBOLS/EXPLANATIONS column 1) gives the reference designators for the item (i.e., C001,
R102, etc.) that corresponds to the number found in the schematics (C001 in a bill of material is equiva
-
lent to C1 on the schematic) or 2) gives added information or further explanation (i.e., “Used for 208V
operation only,” or “Used for HT 10LS only,” etc.).
NOTE: Inside the individual tables some standard conventions are used:
A # symbol in front of a component such as #C001 under the REF. SYMBOLS/EXPLANATIONS col-
umn means that this item is used on or with C001 and is not the actual part number for C001.
In the ten digit part numbers, if the last three numbers are 000, the item is a part that Harris has pur-
chased and has not manufactured or modified. If the last three numbers are other than 000, the item is
either manufactured by Harris or is purchased from a vendor and modified for use in the Harris product.
The first three digits of the ten digit part number tell which family the part number belongs to - for
example, all electrolytic (can) capacitors will be in the same family (524 xxxx 000). If an electrolytic
(can) capacitor is found to have a 9xx xxxx xxx part number (a number outside of the normal family of
numbers), it has probably been modified in some manner at the Harris factory and will therefore show
up farther down into the individual parts list (because each table is normally sorted in ascending order).
Most Harris made or modified assemblies will have 9xx xxxx xxx numbers associated with them.
The term “SEE HIGHER LEVEL BILL” in the description column implies that the reference designated part
number will show up in a bill that is higher in the tree structure. This is often the case for components
that may be frequency determinant or voltage determinant and are called out in a higher level bill
structure that is more customer dependent than the bill at a lower level.
Transmitter
994 9283 001
Control Cabinet
992 9244 002
Controller Board
992 8344 002
PA Cabinet
992 9400 002
PA Amplifier
992 7894 002
PA Amplifier Board
992 7904 002
Output Cabinet
992 9450 001
viii 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
10/6/10 888-2629-200 ix
WARNING: Disconnect primary power prior to servicing.
x 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
10/6/10 888-2629-200 xi
WARNING: Disconnect primary power prior to servicing.
!
WARNING:
TTHE CURRENTS AND VOLTAGES IN THIS EQUIPMENT ARE DANGEROUS.
PERSONNEL MUST AT ALL TIMES OBSERVE SAFETY WARNINGS, INSTRUC
-
TIONS AND REGULATIONS.
This manual is intended as a general guide for trained and qualified personnel who are aware
of the dangers inherent in handling potentially hazardous electrical/electronic circuits. It is not
intended to contain a complete statement of all safety precautions which should be observed
by personnel in using this or other electronic equipment.
The installation, operation, maintenance and service of this equipment involves risks both to
personnel and equipment, and must be performed only by qualified personnel exercising due
care. HARRIS CORPORATION shall not be responsible for injury or damage resulting from
improper procedures or from the use of improperly trained or inexperienced personnel
performing such tasks. During installation and operation of this equipment, local building
codes and fire protection standards must be observed.
The following National Fire Protection Association (NFPA) standards are recommended as
reference:
- Automatic Fire Detectors, No. 72E
- Installation, Maintenance, and Use of Portable Fire Extinguishers, No. 10
- Halogenated Fire Extinguishing Agent Systems, No. 12A
!
WARNING:
ALWAYS DISCONNECT POWER BEFORE OPENING COVERS, DOORS, ENCLO-
SURES, GATES, PANELS OR SHIELDS. ALWAYS USE GROUNDING STICKS
AND SHORT OUT HIGH VOLTAGE POINTS BEFORE SERVICING. NEVER MAKE
INTERNAL ADJUSTMENTS, PERFORM MAINTENANCE OR SERVICE WHEN
ALONE OR WHEN FATIGUED.
Do not remove, short-circuit or tamper with interlock switches on access covers, doors,
enclosures, gates, panels or shields. Keep away from live circuits, know your equipment and
don’t take chances.
!
WARNING:
IN CASE OF EMERGENCY ENSURE THAT POWER HAS BEEN DISCONNECTED.
!
WARNING:
IF OIL FILLED OR ELECTROLYTIC CAPACITORS ARE UTILIZED IN YOUR
EQUIPMENT, AND IF A LEAK OR BULGE IS APPARENT ON THE CAPACITOR
CASE WHEN THE UNIT IS OPENED FOR SERVICE OR MAINTENANCE, ALLOW
THE UNIT TO COOL DOWN BEFORE ATTEMPTING TO REMOVE THE DEFEC
-
TIVE CAPACITOR. DO NOT ATTEMPT TO SERVICE A DEFECTIVE CAPACITOR
WHILE IT IS HOT DWHILE IT IS HOT DUE TO THE POSSIBILITY OF A CASE RUP
-
TURE AND SUBSEQUENT INJURY.
xii 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
10/6/10 888-2629-200 xiii
WARNING: Disconnect primary power prior to servicing.
FIRST-AID
Personnel engaged in the installation, operation, maintenance or servicing of this equipment
are urged to become familiar with first-aid theory and practices. The following information is
not intended to be complete first-aid procedures, it is a brief and is only to be used as a
reference. It is the duty of all personnel using the equipment to be prepared to give adequate
Emergency First Aid and there by prevent avoidable loss of life.
Treatment of Electrical Burns
1. Extensive burned and broken skin
a. Cover area with clean sheet or cloth. (Cleanest available cloth
article.)
b. Do not break blisters, remove tissue, remove adhered particles of
clothing, or apply any salve or ointment.
c. Treat victim for shock as required.
d. Arrange transportation to a hospital as quickly as possible.
e. If arms or legs are affected keep them elevated.
NOTE:
If medical help will not be available within an hour and the victim is conscious and
not vomiting, give him a weak solution of salt and soda: 1 level teaspoonful of salt
and 1/2 level teaspoonful of baking soda to each quart of water (neither hot or
cold). Allow victim to sip slowly about 4 ounces (a half of glass) over a period of
15 minutes. Discontinue fluid if vomiting occurs. (Do not give alcohol.)
2. Less severe burns - (1st & 2nd degree)
a. Apply cool (not ice cold) compresses using the cleanest available
cloth article.
b. Do not break blisters, remove tissue, remove adhered particles of
clothing, or apply salve or ointment.
c. Apply clean dry dressing if necessary.
d. Treat victim for shock as required.
e. Arrange transportation to a hospital as quickly as possible.
f. If arms or legs are affected keep them elevated.
REFERENCE:
ILLINOIS HEART ASSOCIATION
AMERICAN RED CROSS STANDARD FIRST AID AND PERSONAL SAFETY
MANUAL (SECOND EDITION)
xiv 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
Table of Contents
1
Section 1
Introduction
Purpose of This Manual . . . . . . . . . . . . . . . . . . . . 1-1
General Description. . . . . . . . . . . . . . . . . . . . . . . . 1-2
Maxiva COFDM Series Transmitter Models . . . 1-4
System Block Diagram. . . . . . . . . . . . . . . . . . . . 1-4
Transmitter Control System . . . . . . . . . . . . . . . . 1-5
Transmitter RF Power Control . . . . . . . . . . . . . . 1-7
Graphical User Interface . . . . . . . . . . . . . . . . . 1-7
Control System Communications. . . . . . . . . . . . 1-7
Software Updates. . . . . . . . . . . . . . . . . . . . . . . 1-8
Remote Control . . . . . . . . . . . . . . . . . . . . . . . . 1-8
PA Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Module Control . . . . . . . . . . . . . . . . . . . . . . . 1-12
Transmitter Power Supplies . . . . . . . . . . . . . . . 1-13
Cooling System. . . . . . . . . . . . . . . . . . . . . . . . . 1-13
Cooling System Control Panel. . . . . . . . . . . . 1-15
Pump Module/Heat Exchanger . . . . . . . . . . . 1-18
Heat Exchanger Fan Control. . . . . . . . . . . . 1-19
Pump Operation/Control Logic. . . . . . . . . . 1-19
PA Module and Combiner Cold Plates . . . . . 1-20
M2X Multimedia Exciter . . . . . . . . . . . . . . . . . 1-22
General Specifications. . . . . . . . . . . . . . . . . . . . . 1-23
Section 2
Installation
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installation Drawings . . . . . . . . . . . . . . . . . . . . . 2-2
Installation Steps. . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Transmitter Cabinet Placement. . . . . . . . . . . . . . . 2-6
Cooling System Installation . . . . . . . . . . . . . . . . . 2-6
Heat Exchanger and Pump Module
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Calculation of Cooling System Capacities. . . . . 2-9
Rigging Heat Exchanger & Pump Module. . . . 2-11
Initial Inspection. . . . . . . . . . . . . . . . . . . . . . . . 2-11
Placement of Heat Exchanger and Pump
Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Liquid Cooling System Plumbing Installation . 2-14
Pump Module & Heat Exchanger Electrical . . 2-16
Transmitter AC Connection . . . . . . . . . . . . . . . . 2-20
Safety Ground. . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
AC Connections Procedure . . . . . . . . . . . . . . . .2-22
Checking AC Configuration. . . . . . . . . . . . . . . .2-24
TB1 TB2 Jumpers 1 Cabinet 10 -16 Modules.2-24
TB1 TB2 Jumpers 1 Cabinet 1 - 8 Modules . .2-24
Signal and Ground Connections . . . . . . . . . . . . . .2-29
Intercabinet Connections . . . . . . . . . . . . . . . . . . .2-32
External Interlock Connections. . . . . . . . . . . . . . .2-32
Interlock Connector on Customer I/O Panel . . .2-32
Fault-Off Interlocks (Safety Interlocks). . . . . . .2-32
RF Mute External Interlock Connections (J2) . .2-33
3 Port Patch Panel Connections . . . . . . . . . . . . . .2-34
Initial Cooling System Turn ON. . . . . . . . . . . . . .2-34
Heat Exchanger & Pump Module
Start-up and Maintenance . . . . . . . . . . . . . . . .2-36
Starting Pumps & Checking Pump Rotation. .2-38
Starting Fans & Checking Fan Rotation . . . . .2-40
Initial System Leak Tests . . . . . . . . . . . . . . . . . .2-41
Initial System Cleaning . . . . . . . . . . . . . . . . . . .2-42
System Flushing. . . . . . . . . . . . . . . . . . . . . . . . .2-43
Final Cooling System Fill . . . . . . . . . . . . . . . . .2-44
Install PA Modules . . . . . . . . . . . . . . . . . . . . . . . .2-45
Initial Turn-On . . . . . . . . . . . . . . . . . . . . . . . . . . .2-47
Final Cooling System Turn ON . . . . . . . . . . . . . .2-50
Setting the Transmitter Flow Rate . . . . . . . . . . .2-51
Heat Exchanger Fan Turn ON Temperatures. .2-52
Verify Pump Switching (Dual Pumps Only) . .2-52
Normal Pump and Fan Operation . . . . . . . . . .2-53
Operational Pressure Values (typical) . . . . . . .2-53
Setting Exciter Parameters. . . . . . . . . . . . . . . . .2-54
RF Initial Turn ON. . . . . . . . . . . . . . . . . . . . . . .2-54
Individual Transmitter Parallel Remote Control
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-57
Individual Transmitter Commands J3, J4
and J5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-58
Individual Transmitter Outputs J6, J7& J8 . . . .2-59
Individual Transmitter Metering, J9. . . . . . . . . .2-62
External RF Switch . . . . . . . . . . . . . . . . . . . . . .2-62
Install Battery in TCU PCM Card . . . . . . . . . . . .2-63
Section 3
Operation
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Transmitter Control Panel. . . . . . . . . . . . . . . . . . . .3-1
Hardware Control Buttons . . . . . . . . . . . . . . . . . .3-2
Table of Contents (Continued)
2
Graphical User Interface (GUI). . . . . . . . . . . . . . . 3-4
Global Status and Navigation . . . . . . . . . . . . . . . 3-4
GUI Home Screen . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Drive Chain Main Menu . . . . . . . . . . . . . . . . . . . . 3-9
Drive Chain Faults . . . . . . . . . . . . . . . . . . . . . . 3-10
Drive Chain Meters. . . . . . . . . . . . . . . . . . . . . . 3-11
Power Amp Main Menu . . . . . . . . . . . . . . . . . . . 3-13
PA Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
Output Main Screen. . . . . . . . . . . . . . . . . . . . . . . 3-15
Output Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Power Supply Main Menu. . . . . . . . . . . . . . . . . . 3-17
PS Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
System Main Menu . . . . . . . . . . . . . . . . . . . . . . . 3-19
System Faults . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
System Fault Log . . . . . . . . . . . . . . . . . . . . . . . 3-20
System Service . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
Admin Setup (Local GUI Only). . . . . . . . . . . 3-23
System Setup . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
Cabinet Setup . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
System and Cabinet Power Calibrate. . . . . . . 3-27
System Version Screen . . . . . . . . . . . . . . . . . . 3-28
System Network Screen . . . . . . . . . . . . . . . . . 3-28
GUI Menu Structures. . . . . . . . . . . . . . . . . . . . . . 3-29
Section 4
Theory of Operation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Active Logic Symbols. . . . . . . . . . . . . . . . . . . . . 4-1
Block Diagram Descriptions . . . . . . . . . . . . . . . . . 4-2
AC Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Transmitter Control System. . . . . . . . . . . . . . . . . . 4-4
Graphical User Interface (GUI) . . . . . . . . . . . . . 4-4
Transmitter RF Power Control . . . . . . . . . . . . . . 4-5
TCU Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
MCM Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
PCM Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
RF Detector/Pump Control/Interlocks Card. . 4-10
PA Interface Card . . . . . . . . . . . . . . . . . . . . . . 4-13
Predriver and IPA Drive A and B Busses . . 4-13
PA BP (Backplane) Busses 1 Through 4. . . 4-14
Customer I/O Card . . . . . . . . . . . . . . . . . . . . . 4-15
Exciter Switcher Card. . . . . . . . . . . . . . . . . . . 4-16
PS Monitor Card. . . . . . . . . . . . . . . . . . . . . . . 4-18
CPLD (Complex Programmable Logic
Device) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Life Support Functions . . . . . . . . . . . . . . . . . . . 4-22
Controller Area Network (CAN) Bus. . . . . . . . 4-24
System Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
Cabinet Bus. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26
Parallel Control Lines. . . . . . . . . . . . . . . . . . . . 4-27
Customer I/O Board . . . . . . . . . . . . . . . . . . . . . . 4-28
Transmitter RF System . . . . . . . . . . . . . . . . . . . . 4-29
Apex M2X Exciter(s) . . . . . . . . . . . . . . . . . . . . 4-29
Predriver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
IPA (driver) and PA Module. . . . . . . . . . . . . . . 4-33
AC Distribution Board. . . . . . . . . . . . . . . . . . 4-35
AC/DC Converter Interface Board. . . . . . . . . 4-35
PA PS (AC/DC) Voltage Select Path . . . . . . . 4-36
PA Monitor Board . . . . . . . . . . . . . . . . . . . . . 4-38
J1 - PA or IPA Connector I/O Board . . . . . . . 4-39
Signal Distribution Board. . . . . . . . . . . . . . . . 4-41
PA Module Phase Alignment . . . . . . . . . . . . 4-41
PA Module Splitter. . . . . . . . . . . . . . . . . . . . . 4-41
PA Module Pallet Combiner. . . . . . . . . . . . . . 4-41
RF Pallets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
FET Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-43
Module Combiner. . . . . . . . . . . . . . . . . . . . . . . 4-43
Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44
Heat Exchanger/Pump Module Diagrams . . . . 4-44
Leak Detector and Cabinet Drains . . . . . . . . . . 4-48
Maxiva 16 Module Transmitter Diagrams . . . . . 4-49
RF Block Diagram . . . . . . . . . . . . . . . . . . . . . . 4-49
Section 5
Maintenance and Alignments
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
PA Module Removal and Replacement. . . . . . . . . 5-1
PA Slot Locations . . . . . . . . . . . . . . . . . . . . . . . . 5-2
PA Module Removal. . . . . . . . . . . . . . . . . . . . . . 5-3
PA Module Installation . . . . . . . . . . . . . . . . . . . . 5-4
Operation With Inoperative PA Modules . . . . . . 5-6
PA Module/Rack Alignment. . . . . . . . . . . . . . . . 5-6
PA Module Bias. . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
PA Module Phasing. . . . . . . . . . . . . . . . . . . . . . . . 5-9
PA Module Component ID . . . . . . . . . . . . . . . . . . 5-9
PA and IPA (driver) Pallet Replacement . . . . . . . 5-11
PA Module AC/DC Converter (PS) Board . . . . . 5-13
PS Board Removal and Replacement. . . . . . . . 5-13
Table of Contents
3
AC/DC Converter (PS) Board Output Voltage. 5-14
Setting Voltage: . . . . . . . . . . . . . . . . . . . . . . . 5-14
Power Calibrations . . . . . . . . . . . . . . . . . . . . . . . 5-15
Forward Power Calibration . . . . . . . . . . . . . . . 5-15
Calibrate Forward Total Power . . . . . . . . . . . 5-16
Calibrate Forward Cabinet Power:. . . . . . . . . 5-18
Reflected Power Calibrate . . . . . . . . . . . . . . . . 5-18
Calibrate Reflected Total Power . . . . . . . . . . 5-19
Calibrate Reflected Cabinet Power . . . . . . . . 5-20
Exciter Output Calibration . . . . . . . . . . . . . . . . 5-21
PDU Calibration . . . . . . . . . . . . . . . . . . . . . . . . 5-21
Threshold Settings . . . . . . . . . . . . . . . . . . . . . . 5-22
Exciter A & B Threshold Settings. . . . . . . . . 5-23
Cabinet Reject Load Thresholds . . . . . . . . . . 5-24
System Reflected Thresholds. . . . . . . . . . . . . 5-24
System Foldback Power. . . . . . . . . . . . . . . . . 5-24
FWD Pwr Warn . . . . . . . . . . . . . . . . . . . . . . . 5-24
Fwd Pwr Flt . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
PA Cabinet Fan Replacement . . . . . . . . . . . . . . . 5-25
Cabinet Fan Removal . . . . . . . . . . . . . . . . . . . . 5-25
PA Cabinet RF System Removal. . . . . . . . . . . . . 5-27
RF System Removal. . . . . . . . . . . . . . . . . . . . . 5-27
Miscellaneous Maintenance . . . . . . . . . . . . . . . . 5-34
Cooling System Checks . . . . . . . . . . . . . . . . . . 5-34
Heat Exchanger Cleaning . . . . . . . . . . . . . . . 5-34
Alternate Pumps. . . . . . . . . . . . . . . . . . . . . . . 5-34
Pump Module Strainer Cleaning . . . . . . . . . . 5-34
Coolant Level Management: . . . . . . . . . . . . . 5-36
Cooling System Maintenance Notes . . . . . . . 5-37
Coolant Checks: . . . . . . . . . . . . . . . . . . . . . 5-37
Changing Pumps: . . . . . . . . . . . . . . . . . . . . 5-37
Pump Module Operation Without
Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . 5-38
Air Filter Replacement . . . . . . . . . . . . . . . . . . . 5-38
LCD Screen Adjustments. . . . . . . . . . . . . . . . . 5-39
LCD Screen Contrast. . . . . . . . . . . . . . . . . . . 5-39
Touch Screen Calibration. . . . . . . . . . . . . . . . 5-39
Date and Time Settings . . . . . . . . . . . . . . . . . 5-40
Changing the Battery on the PCM Card. . . . . . 5-40
PCM Battery Installation Instructions: . . . . . 5-41
TCU Card Replacement . . . . . . . . . . . . . . . . . . 5-45
MCM Card Replacement. . . . . . . . . . . . . . . . 5-46
Typical Test Equipment. . . . . . . . . . . . . . . . . . . . 5-47
Section 6
Diagnostics
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
GUI System Log. . . . . . . . . . . . . . . . . . . . . . . . . . .6-2
Maxiva Three-Strike Fault Actions. . . . . . . . . . . . .6-3
Reflected Power Faults. . . . . . . . . . . . . . . . . . . . .6-3
Module Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . .6-4
Fault Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-5
Section 7
Parts List
Replaceable Parts List. . . . . . . . . . . . . . . . . . . . . . .7-1
Heat Exchanger/Pump Module Replacement Parts7-13
Appendix-A
Cutting & Soldering Transmission Line. . . . .A-1
Appendix-B
Cooling System Help . . . . . . . . . . . . . . . . . . .B-1
Appendix-C
Grounding Considerations,
Surge & Lightning Protection . . . . . . . . . . . .C-1
Appendix-D
Lightning Protection Recommendation . . . . .D-1
Table of Contents (Continued)
4
10/6/10 888-2629-200 1-1
WARNING: Disconnect primary power prior to servicing.
Maxiva ULX COFDM Series
Section 1
Introduction
1
1.1 Purpose of This Manual
This technical manual contains the information pertaining to the Maxiva ULX Series,
solid-state, UHF, COFDM digital TV transmitter. The various sections of this technical
manual provide the following types of information.
Section 1, Introduction, provides general manual layout, photos, equipment descrip-
tion, block diagram and general specifications.
Section 2, Installation/Initial Turn-On, provides physical and electrical installation
procedures for the transmitter, cooling and RF systems and basic remote control con-
nections.
Section 3, Operation, provides operation and navigation information for the Graphi-
cal User Interface or GUI as well as identification and functions of all external panel
controls and indicators.
Section 4, Theory of Operation, provides detailed theory of operation for the trans-
mitter and sub-assemblies.
Section 5, Maintenance and Alignments, provides preventative and corrective main-
tenance information and all field alignment procedures.
Section 6, Diagnostics, provides detailed fault information and diagnostic procedures
to the board level.
Section 7, Parts List, provides a parts list for the overall transmitter as well as indi-
vidual modules.
1-2 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
Maxiva ULX COFDM Series
1.2 General Description
This section contains a general description of the Maxiva ULX Series COFDM digital
television transmitters. Included in this section will be descriptions of the control
system, power amplifier, block diagrams of the different models and system
specifications.
Figure 1-1 ULX-8700** Front View
Redundant Drivers
Redundant Pre-Driver A
Apex M2X Exciter B
PA Slots 11-18
Apex M2X Exciter A
Redundant Pre-Driver B
PA Slots 1-8
TCU System Controller
IPA A (slot 10)
11
18
A
B
8
1
IPA B (slot 9)
/