![](//vs1.manuzoid.com/store/data-gzf/d49f85a7c4d6d919d29335e3c5bf4252/2/001249852.htmlex.zip/bg2.jpg)
Jun 30/01
38-31-01
Page 201
EFFECTIVITY:
All
z
SD3-60 AIRCRAFT MAINTENANCE MANUAL
AMM38-31-01 2.0.0.0WATER CLOSET - MAINTENANCE PRACTICES
1. Removal/Installation
A. Remove a water closet.
(1) Drain and flush the water closet. Refer to 12-10-38, pb301.
(2) Isolate electrical supply to water closet by opening circuit breaker 129 on Tail Distribution
Panel 3D.
(3) Remove panel 265 DZ, between Stn. 475 and 508, right side.
(4) Disconnect the electrical connections at TB 124 terminals 1 & 2.
(5) Remove screws from base moulding of water closet and remove moulding.
(6) Remove four bolts from support angles of water closet.
(7) Lift water closet up to clear floor fitting.
B. Install a water closet.
NOTE: Operation (1) only applies if unit is that which has been removed. Operation (3) only
applies if unit is not that previously removed.
(1) Clean any residual sealant from around water closet outlet.
(2) Clean any residual sealant from around floor fitting.
(3) Remove screws from base moulding of water closet and remove moulding.
(4) Install water closet in position making sure that it seats into floor fittings.
(5) Install four bolts in water closet support angles and tighten.
(6) Apply sealant PR 1422-B locally, where required.
(7) Fit base moulding to water closet and tighten attachment screws.
(8) Identify and make electrical connections at TB 124 terminals 1 and 2.
(9) Replace panel 265 DZ between Stn. 475 and 508, right side.
(10) Energize electrical circuit by closing circuit breaker 129 on Tail Distribution Panel 3D.
(11) Ensure that drain valve handle at base of water closet is in the closed position and
locked.
(12) Replenish the water closet. Refer to 12-10-38, pb301.