Part numbers:
Fixed:- ADV3KW & ADV4KW
Anti-glare:- ADVAG3KW & ADVAG4KW
Tilt:- ADVT3KW & ADVT4KW
Dia.1
Stage 2 -
These luminaires are suitable for a 30, 60 or 90 minute fire
rated ceiling only.
Cut a suitable hole (sizes shown in the technical
information table overleaf).
Dia.2
Stage 3 -
Press springs back and push luminaire body into aperture.
Connect the luminaire to the supplied driver. As shown
overleaf.
It is recommended that luminaires are installed and fitted
by a qualified electrician ensuring the installation complies
to the current IET wiring regulation.
If replacing existing fitting, please ensure you follow these
instructions and the appropriate wiring regulations. This
product is designed for connection to a 230V AC Mains
supply.
Always switch off mains supply before servicing a fitting.
Special attention should be paid for any installations with
low ceiling voids.
This fitting is compatible with most leading and trailing
edge dimmers for best results use a dimmer designed for
LED drivers.
Please note that many dimmers have a minimum load
requirement which may mean multiple units have to be
connected for the dimmer to function correctly.
Please see GreenBrook website for compatible dimmers -
www.greenbrook.co.uk.
We recommend that a sample hole is cut in some scrap
material to familiarise yourself with the installation.
Once you are completely satisfied, locate the areas
suitable to install these luminaires. Cut a suitable round
hole in the ceiling (see cut out size in table overleaf) and
ensure there is sufficient space in the ceiling void without
infringing on joist, water pipes or electrical cables.
Fit this product as illustrated. Connect this product to a
mains 230V supply only. Connect the Brown feed wire to
“L”, connect the Blue feed wire to “N”. Driver is class 2
and does NOT require an earth connection. However 2
earth connections are provided on the driver to maintain
circuit earth continuity.
Ensure there is adequate free air ventilation around the
fitting. The nearest illuminated surface must be at least
0.5m distance from the front of the fitting. Do not install
this product into new plaster or damp areas.
Stage 1 -
Read instructions and check you have all the tools and
accessories to complete installation correctly.
INSTALLATION INSTRUCTIONS
IMPORTANT INFORMATION
Installation Instructions for:-
‘Vela Advance’ Range
-LED 30, 60 & 90 Mins
Fire Rated Mains Voltage
Dimmable Downlights
Vela Advance Ins July 21.qxp_LED FR 09/08/2021 08:15 Page 1