  • Hello! I am an AI chatbot trained to assist you with the Malco Gutter Outlet Punches Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1. Remove blade assembly mounting bolt to
disconnect blade assembly from drive rod.
(Avoid damaging blades).
2. Pull drive rod out of tool through top.
3. Remove release chocks and drive chock,
(the springs will be loose). Replace drive
chocks and release chock while holding
the springs in position.
4. Insert drive rod through top slot and work
it through the chocks and springs and
through bottom slot.
5. Connect blade assembly to drive rod.
GOT
CHOCK REPLACEMENT INSTRUCTIONS
Top Slot
Release
Chock
Drive Rod
Springs
Drive
Chocks
Bottom
Slot
Blade
Assembly
Mounting
Bolt