Wincor Nixdorf BEETLE /NetPOS Operating instructions

Category
Cash registers
Type
Operating instructions
BEETLE NetPOS
Modular POS System
User Guide
Edition January 2000
Copyright© Wincor Nixdorf GmbH & Co. KG, 2000
The reproduction, transmission or use of this document or its contents is not
permitted without express authority.
Media GXm™ is a registered trademark of the National Semiconductor Corporation
Linux™ is a registered trademark of Linus Torvalds
Pentium™ is a registered trademark of the Intel Corporation
MS-DOS™, Windows 95™, Windows 98™, Windows NT™ and Windows CE™ are
registered trademarks of the Microsoft Corporation
BEETLE™ is a registered trademark of Wincor Nixdorf GmbH & Co. KG
Contents
Manufacturers Certification................1
Tested Safety ...............................1
FCC-Class A Declaration .........................1
Important notes ..............................2
Introduction ........................3
About this manual .............................4
Care of the BEETLE NetPOS .......................5
Recycling the BEETLE NetPOS......................6
Warranty..................................7
BEETLE NetPOS .....................8
Overview .................................8
BEETLE NetPOS Peripherals .....................9
BEETLE NetPOS in a network . ...................10
Before switching on the System .....................11
Unpacking and checking the System .................11
Setting up the device .........................11
Cabling of the BEETLE NetPOS ...................11
Disconnecting cables .........................12
Mounting the cable cover .......................13
Connecting to the mains power supply ................13
Basic settings .............................14
Adjusting the loudspeaker.......................14
Light emitting diode (LED) ......................14
Connecting peripherals .........................15
Keyboard (KYBD) ...........................16
Scanners and scales (COM1 - COM4*)................16
Customer display (COM2* or COM4*) ................17
Cashier display (COM3*) .......................17
Monitor ................................17
TFT - LCD display...........................18
Connecting standard PC peripherals (COM1) ............18
Network ................................19
Modular printers ...........................19
Cash drawer (1,2) ...........................20
BEETLE NetPOS - the components...........21
Overview.................................21
Floppy disk drive.............................23
General ................................23
Inserting a disk ............................24
Removing a disk ...........................24
CPU...................................24
General ................................24
Interfaces ...............................25
Loudspeaker .............................25
Nonvolatile RAM (NV-RAM)......................25
Dynamic RAM.............................26
Connection options ..........................26
Power Supply ..............................27
Changing the CMOS battery .....................28
Configuration variants ..................30
Submodules for the CPU.........................30
ASYNC controller ...........................30
LAN controller 10/100 MBit ......................30
CRT- or TFT-adapter .........................30
Installing the submodules when using a TFT/CRT adapter......30
Installing the submodules .......................32
Change of the hard disk .........................33
Software..........................34
Operating system ............................34
Retail device interface ..........................34
Application programs...........................34
Retail presentation manager .......................34
Retail transaction manager .......................35
High frequency table...........................35
Hash file access method .........................35
Starting up the system..................36
Start and runup behaviour ........................36
BIOS Cluster...............................38
BIOS setup ........................39
Notes...................................45
Power On Self Test (POST) .......................51
Output of MS-DOS system error messages .............52
POST extended error messages ...................53
Phoenix BIOS POST and Start Messages ..............54
Additional messages .........................56
Appendix .........................57
Technical data for the BEETLE NetPOS.................57
CPU...................................58
Jumper settings .............................59
Jumper Locations of the Media GXm board .............60
Setting the CPU frequency by Freq ..................60
Setting interrupt for COM3, COM4 ..................61
Setting the non-volatile memory size by NVR.............62
Setting the touch function on the TFT adapter ............62
Glossary .................................64
Abbreviations...............................66
Manufacturers Certification
The device complies with the requirements of the EEC
directive 89/336/EEC with regard to ‘Electromagnetic
compatibility" and 73/23/ECC “Low Voltage Directive”.
Therefore, you will find the CE mark on the device or packaging.
Tested Safety
The POS system has been provided with the symbol for
“Tested Safety”.
In addition, the BEETLE has received the UL symbol and cUL
symbol.
FCC-Class A Declaration
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
Le présent appareil numérique ne génère pas de bruits radioélectriques
dépassant les limites applicable aux appareils numériques de la “Class A”
prescrites dans le Règlement sur le brouillage radioélectrique édicté par le
ministère des Communications du Canada.
1
TESTED SAFETY
geprüfte
Sicherheit
Important notes
The modular POS system BEETLE NetPOS conforms to the current safety
standards for data processing equipment.
If this device is taken from a cold environment into the operating room,
moisture condensation may form. The device must be absolutely dry before
being put into service; an acclimatization period of at least two hours must
therefore be observed.
n
This device is equipped with a safety-tested power cable and may be
connected only to a prescribed grounded-contact power socket.
n
When setting up the device, ensure that the power socket on the device
and the grounded-contact power socket are easily accessible.
n
To disconnect the device from the supply voltage completely, switch off
the device and disconnect the power plug.
n
Ensure that no foreign objects (c.g. office clips) find their way into the
device, as this may lead to electric shocks or short-circuits.
n
Never plug in or unplug data communication lines during
thunderstorms.
n
Protect devices from vibrations, dust, moisture and heat.
n
Always dispose of used parts, such as batteries, in an environmentally
safe manner.
n
The lithium battery must be disposed of in accordance with local
regulations for special waste.
n
In emergencies (e.g. damaged housing or damaged power cable,
penetration by liquids or foreign bodies), the device must be switched
off immediately, the power plug disconnected and the Customer
Service of Wincor Nixdorf (WN) or your dealer must be notified.
n
The device may only be repaired by authorized qualified personnel.
Unauthorized opening of the device and inexpertly carried-out repairs
may not only seriously jeopardize the safety of the user, but also cancel
all warranty and liability agreements.
IMPORTANT NOTES
2
Introduction
The BEETLE NetPOS is the compact, powerful and economical basis for
your POS system.
The BEETLE conforms to the PC/AT industry standard. Powerful
processors ensure a quick processing of all operations.
You can connect a variety of different peripheral devices to your BEETLE
and even the choice of the software is not limited to a certain product.
Optional the BEETLE NetPOS can be equipped with a floppy disk drive or a
memory card adapter, a hard disk or a compact flash.
This provides you with a considerable degree of flexibility when arranging
the configuration of your POS system.
The BEETLE can also be connected to a network once an appropriate
network card has been installed.
In the event of a mains voltage failure, the version with battery and
corresponding software enables you to save the data by means of a
controlled program shutdown.
Whatever configuration you need: Wincor Nixdorf offers the right solution.
So, whenever you want to expand your BEETLE NetPOS, please contact
your Wincor Nixdorf GmbH branch office or your dealer.
3
About this manual
This manual describes the modular POS system BEETLE NetPOS with a
Media GXm processor.
This documentation is intended to help you work with the POS system and
to serve as a reference work. The detailed table of contents help you find
the desired information quickly and easily.
The first section describes
n
everything you need to do before switching on the POS system and
n
how to connect peripherals to the BEETLE NetPOS.
The second section contains
n
a brief overview of the components of your BEETLE POS system.
Here, you will also find a detailed description of recurring actions, for
example, how to use the disks.
The third selection provides
n
a brief overview of the software implemented in the modular system
BEETLE NetPOS.
The fourth section explains
n
the procedure for system starting and setup. This section requires
technical knowledge.
The Appendix
n
contains the most important technical data, a list of possible error
messages, a glossary and a list of abbreviations.
Notes in the manual are marked by this symbol.
This symbol is used for warnings.
The type and scope of application programs depend on the customer’s own
selection; therefore, with the exception of the Setup program and a brief
description of the most important WN programs, software will not be
discussed further in this manual.
Separate manuals are included in the scope of the connectable peripherals.
For this reason, a more detailed description of these devices will not be
provided here. For more information, see the relevant manuals.
About this manual
4
Care of the BEETLE NetPOS
Clean your BEETLE NetPOS at regular intervals with a suitable
plastic-surface cleaner. Make sure that the power plug is disconnected,
connector cables are unplugged and that no liquid finds its way into the
device.
5
CARE OF THE BEETLE NETPOS
Recycling the BEETLE NetPOS
Environmental protection does not begin when
it comes time to dispose of the BEETLE; it
begins with the manufacturer. This product was
designed according to our internal norm
“Environmental conscious product design and
development”
The modular BEETLE NetPOS POS System is manufactured without the
use of CFCs and CCHS and is produced mainly from reusable components
and materials.
The processed plastics can, for the most part, be recycled. Even the
precious metals can be recovered, thus saving energy and costly raw
materials.
Please do not stick labels onto plastic case parts. This would help us to
re-use components and material.
You can protect our environment by only switching on your equipment when
it is actually needed. If possible, even avoid the stand-by-mode as this
wastes energy, too. Also switch your equipment off when you take a longer
break or finish your work.
At this time, there are still some parts that are not reusable. Wincor Nlxdorf
guarantees the environmentally safe disposal of these parts in the
Recycling Center, which is certified pursuant to ISO 9001.
So don’t simply throw your BEETLE POS system on the scrap heap when it
has served its time, but take advantage of the environmentally smart,
up-to-date recycling methods!
Please contact your competent branch or the Recycling Center Paderborn
(for European countries) for information on how to return and re-use
devices and disposable materials under the following telephone/fax
numbers:
Tel.: +49 (0) 5251 8-18010, Fax: +49 (0) 5251 8-18015
is always ready to answer any questions you may have about
Wincor Nixdorf GmbH environmental protection policies. We look forward to
your telephone call or your fax.
RECYCLING THE BEETLE NETPOS
6
Warranty
Wincor Nixdorf guarantees a limited warranty engagement for 12 months
beginning with the date of delivery. This warranty engagement covers all
those damages which occur despite a normal use of the product.
Damages because of
n
Improper or insufficient maintenance,
n
Improper use of the product or unauthorized modifications of the
product,
n
Inadequate location or surroundings
will not be covered by the warranty.
All parts of the product which are subject to wear and tear are not included
in the warranty engagement. Please order spare parts at the Wincor Nixdorf
customer service.
7
WARRANTY
BEETLE NetPOS
Overview
You can connect a variety of peripherals to your modular POS system
BEETLE NetPOS and thus implement a wide range of expansion stages.
You can connect a two or four-line alphanumeric customer display and a
four line cashier display. Alternatively you can connect Flat screens, such
as BA69 (VGA/4), BA70 (b/w) or BA71 and BA72 (color), use various types
of scanners such as distance, touch or stationary scanners, use scales and
scanner scales (please take into account the official certification
regulations), connect various printers, use POS keyboards with or without a
swipecard reader, use different types of cash drawers, connect a monitor,
install the POS workplace SNIkey, integrate the BEETLE NetPOS in a
network.
This means that the BEETLE NetPOS can meet your requirements at all
times, without having to exchange the complete system for a new one, thus
saving you time and money.
The illustration below show you how your modular POS system can grow -
from a scanner to integration in a network.
8
BEETLE NetPOS Peripherals
9
OVERVIEW
PrinterScanner
Cash drawer
Scales
Monitor
Flatscreen
display
Keyboard
BA69
Customer or cashier display
SNIkey
BEETLE NetPOS in a network
OVERVIEW
10
Ethernet 10/100 Base T
Server
BEETLE NetPOS
Beforeswitching on the System
Unpacking and checking the System
Unpack the parts and check to see whether the delivery matches the
information on the delivery note.
The carton contains the basic unit and a country-specific accessories kit.
Some ordered composition may be installed.
If damage has occurred during shipping or if the package contents do not
match the delivery note, promptly inform your Wincor Nixdorf sales outlet.
Transport the device only in its original packaging (to protect it against
impact and shock).
Setting up the device
Set up the BEETLE NetPOS POS system where it will not be exposed to
extreme environmental conditions. Protect the device from vibrations, dust,
moisture, heat and strong magnetic fields.
Make sure that the side ventilation slots on the BEETLE NetPOS POS
system are not obstructed in order to ensure that the device has sufficient
ventilation.
Cabling of the BEETLE NetPOS
Follow the steps below in the order given when installing devices:
n
Make sure that the power switch on the front of the housing is set to
OFF, i.e. that it visibly protrudes.
n
The cable cover must be removed, if present.
n
Plug one end of the power cable into the external power supply and
connect the other end to the main power supply.
n
Plug one end of the other power cable into a grounded-contact power
socket of the external power supply and the other into the socket of the
BEETLE NetPOS.
11
BEFORE SWITCHING ON THE SYSTEM
n
Plug in and secure the data cable.
Always make sure that the system is switched off when you do cabling
works.
Disconnecting cables
Never unplug a cable by pulling on the cable itself; always take hold of the
actual plug. Follow the procedure below when disconnecting cables:
n
Turn off all power and equipment switches.
n
Remove the cable cover.
n
Unplug all data communication cables from the sockets of the data
networks.
n
Unplug all power plugs from the grounded-contact power sockets.
n
Unplug all cables from the devices.
With MINI-DIN plugs, the plug remains inserted
until released.
Pull the plastic covering from the connecting
socket with your thumb. The lock is released.
The metal of the plug is visible.
RJ12 plugs lock in when you insert them. To
release them push the latch under the plug to
the top.
Remove the two screws.
BEFORE SWITCHING ON THE SYSTEM
12
Mounting the cable cover
The scope of supply of your BEETLE NetPOS includes a cable cover.
Before mounting the device, you should first remove the cable openings
where necessary. This depends on the cables which you wish to lay.
Tools are not required as the plastic parts can be removed by hand.
In order to mount the cable cover, insert it in the guide and turn it to the
BEETLE box. Press from the inside against the exterior and pull it to the
rear side until it is fixed in the second pin on the back of the BEETLE
box.
In doing so, ensure that the cable cover does not fit askew.
Connecting to themains power supply
All devices belonging to the modular BEETLE NetPOS system that have a
separate power cable must be connected to the same electric circuit.
n
Make sure that all data cables on the system unit and peripherals are
connected correctly.
n
Make sure that the DC cable is connected to power supply and to
system unit.
n
Plug all power cables belonging to the BEETLE and the peripherals into
the grounded-contact power sockets.
13
BEFORE SWITCHING ON THE SYSTEM
You can now switch on
the BEETLE NetPOS by
means of the switch on
the external power
supply. Push the ON
button at the front of the
box.
The power supply can be connected to all standard power supply networks.
The unit adjusts automatically to the respective voltage. The maximum
output of the power pack is 150 W.
Basic settings
Ex works, the BEETLE NetPOS is configured to your order. Your
configuration must be subsequently adapted to support supplementary
devices such as scanners. For more information, contact the WN branch
office responsible for your area.
Adjusting the loudspeaker
You can set the volume as desired by means of a menu in the BIOS Setup.
Light emitting diode (LED)
The left LED (green) lights when the BEETLE
NetPOS is switched on. The right LED (yellow)
lights up while the hard disk is being accessed.
BEFORE SWITCHING ON THE SYSTEM
14
On button ON/OFF switch
Connecting peripherals
The peripherals mentioned here are available as options and are not part of
the basic configuration. A separate manual is provided for each of the
connectable components. For more detailed information, please consult the
relevant documentation.
The figure shows the back panel of the BEETLE NetPOS with the locations
of the connecting sockets and connecting plugs. If you wish to connect a
monitor, however, you must also have a video board.
CRT and TFT interfaces are used alternatively.
Connecting peripherals with the system switched on is not allowed.
Rear panel of the BEETLE NetPOS
Rear panel of the power supply
15
CONNECTING PERIPHERALS
KYBD COM1
VGA
COM4* COM3* COM2*USB
LAN/ASYN
LPT1
Power Connector
0
I
ON/OFF Cash Drawer 1, 2
POS Printer Power
Mains Socket
Subconnector
Mains
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Wincor Nixdorf BEETLE /NetPOS Operating instructions

Category
Cash registers
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI