American Standard 3351.001 User manual

Category
Sanitary ware
Type
User manual
N63
© 2011 AS America Inc.
Revised 11/11
AFWALL
®
1.6 GPF
FLUSHOMETER TOILET SYSTEM
with EVERCLEAN
®
MANUAL FLUSH VALVE
AFWALL
®
1.6 GPF
FLUSHOMETER TOILET SYSTEM with EVERCLEAN
®
2856.0161.6gpfExposedTopSpudBowl
and Manual Flush Valve
BOWL:
•Wall-mountelongatedushometervalvetoilet
•Vitreouschina
•HighEfficiency,LowConsumption.Operatesinthe
rangeof1.1gpfto1.6gpf(4.2Lpfto6.0Lpf)
•MeetsdenitionofHET(HighEfficiencyToilet)when
usedwithahighefficiencyushvalve(1.28gpfor
1.6/1.1gpfDualFlush)
•PermanentEverClean
®
surface inhibits the growth of
stain-andodor-causingbacteria,mold,andmildewon
the surface
•Condensationchanel
•Direct-fedsiphonjetaction
•1-1/2"inletspud
•Fullyglazed2-1/8"trapway
•10"x12"watersurfacearea
•100%factoryushtested
•Boltcapsandseatnotincluded
•Model3351.001
MANUAL FLUSH VALVE:
•ManualPiston-TypeWaterClosetFlushValvefor
oor-mountedorwall-hung1-1/2"topspudbowls
•Self-cleaningbrasspistonwithintegralwiperspring
prevents clogging and reduces maintenance
•Pistonoperationdeliverssuperiorushaccuracy
andrepeatability
•Pistonvalveremainsclosedanddoesnotneed
to be reset after loss of water pressure
•Non-holdopenhandle
•Positivesealensuresleak-freeperformance
•Noexternalvolumeadjustment
•Durablechrome-platedcastbrassconstruction
is ideal for commercial applications
•Chloramine-resistantEPDMseals
•Adjustabletailpieceforrough-inexibility
•Canbeinstalledleftorrighthanded
•Model6047.161.002
Includes:
•047007-0070AInletspud(furnishedwithbowl)
•1"I.P.S.anglestopwithback-owpreventionand
vandal-resistant cap
•Sweatsolderkitincludingcovertubeandwallange
•Highbackpressurevacuumbreakerwithdowntube
•Spudcoupling&angefor1-1/2"topspud
SEEREVERSEFORROUGHING-INDIMENSIONS
System MaP* Score:
1,000gramsofmiso@1.6gpf
* MaximumPerformance(MaP)testingperformedbyIAPMO
R&TLab.MaPReportconductedbyVeritecConsulting,
Inc.andKoellerandCompany.
Operating Pressure:
OverallRange:20-125psi**
Recommended:25psi(owing)-80psi(static)
**Waterpressureover80psiisnotrecommended
formostplumbingxtures.
Flow Requirement:
25gpm(94.6L/min.)
Nominal Fixture Dimensions:
635x375x381mm(25"x14-3/4"x15")
Fixture Compliance Certications -
Meets or Exceeds the Following Specications:
•ASMEA112.19.2-2008/CSAB45.1-08for
VitreousChinaFixtures
Valve Listings:
•ASSE1037
•ANSI/ASMEA112.19.2
•ADACompliant
BARRIER FREE
To Be Specied:
Color:White
Seat:5901.100AmericanStandardSeat
5901.110 American Standard Seat withEverClean
®
AlternateSeat:5905.100HeavyDuty
American Standard Seat
5905.110HeavyDutyAmerican Standard Seat
withEverClean
CarrierFitting(byothers):
N64
© 2011 AS America Inc.
Revised 11/11
NOTES:
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING
NOT RECOMMENDED).
SUGGESTED2mm(1/16)CLEARANCEBETWEENFACEOFWALLANDBACKOFBOWL.
TOCOMPLYWITHAREACODEGOVERNINGTHEHEIGHTOFVACUUMBREAKERON
THEFLUSHOMETERVALVE,THEPLUMBERMUSTVERIFYDIMENSIONSSHOWNFOR
SUPPLYROUGHING.
CARRIERFITTINGASREQUIREDTOBEFURNISHEDBYOTHERS.
PROVIDESUITABLEREINFORCEMENTFORALLWALLSUPPORT.
IMPORTANT:Dimensionsofxturesarenominalandmayvarywithintherangeof
tolerancesestablishedbyANSIStandardA112.19.2.
Thesemeasurementsaresubjecttochangeorcancellation.Noresponsibilityisassumedfor
use of superseded or voided pages
AFWALL
®
1.6 GPF
FLUSHOMETER TOILET SYSTEM
with EVERCLEAN
®
MANUAL FLUSH VALVE
FINISHED WALL
470mm
(18-1/2")
C/L OF SEAT POST
HOLES 140 mm
(5-1/2") CENTER
660mm
(26")
133mm
(5-1/4")
191mm
(7-1/2")
(4x)
22mm
(7/8")
HOLES
C/L OF
OUTLET
FINISHED
FLOOR
32 mm
(1-1/4")
381mm
(15")
330mm
(13")
133mm
(5-1/4")
95mm
(3-3/4")
19mm
(3/4")
70mm
(2-3/4")
229mm
(9")
Valve Left or Right Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be a minimum of 6" (152mm) above
fixture. Consult Codes for details.
73mm
(2-7/8")
356mm
(14")
*CRITICAL
LEVEL
SUPPLY
DN 25mm
(1" I.P.S.)
-C-L-
108 -133mm
(4-1/4" to 5-1/4")
293mm
(11-1/2")
ROUGH-IN
DIMENSION
343mm
(13-1/2")
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so that top of seat is 432 to 483mm (17" to 19") from the finished floor.
BARRIER FREE
  • Page 1 1
  • Page 2 2

American Standard 3351.001 User manual

Category
Sanitary ware
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI