Roche cobas e 601 User manual

Type
User manual

This manual is also suitable for

cobas 6000
TraceDocArchiver
Operator´s Manual
Software Version 1.03
Roche Diagnostics
Operator´s Manual · Version 1.3 3
cobas 6000 TraceDocArchiver
Table of contents
Document information .......................................................................................................5
Limited warranty .................................................................................................................5
Welcome to cobas 6000 TraceDocArchiver ....................................................................6
Preface .............................................................................................................................6
Important information .................................................................................................7
System requirements .....................................................................................................8
Package content .............................................................................................................8
Starting the program ...........................................................................................................9
User interface overview ....................................................................................................10
The heading area .........................................................................................................11
The error/information area ........................................................................................12
The tab navigation area ..............................................................................................12
The tab content area. ...................................................................................................12
Import/Drop .......................................................................................................................13
First run ........................................................................................................................13
Import a SVP (backup) file ........................................................................................14
Multiple instruments defined ....................................................................................16
Mass import .................................................................................................................17
Imports history ..................................................................................................................18
Re-import .....................................................................................................................19
Export ..................................................................................................................................20
Optical export ..............................................................................................................20
Network export ............................................................................................................22
Configuration .....................................................................................................................23
Instrument Management ...........................................................................................24
Misc (maintenance) ...........................................................................................................26
Purge old data ..............................................................................................................26
System messages ..........................................................................................................27
Installing the cobas 6000 TraceDocArchiver ................................................................29
Items needed ................................................................................................................29
Installation ....................................................................................................................29
Uninstalling ..................................................................................................................34
Update the program ....................................................................................................34
Appendix .............................................................................................................................35
Appendix A (Issue resolving) ....................................................................................35
Find the debug logfile ...........................................................................................35
Reset user settings to default ................................................................................35
Change debug log level .........................................................................................35
Removing lingering lock file ................................................................................35
Appendix B (System Message messages) .................................................................36
System Message messages ..........................................................................................36
Message reference across application .......................................................................36
Appendix C (Information for IT supporters) .........................................................39
Appendix D (Technical Documentation) ................................................................41
Database File Location .........................................................................................41
TraceDoc structure ...............................................................................................42
Traceability claim ..................................................................................................43
Export data table definition C6kTDocArchiverOutput.db3 ............................ 44
Export data index definition C6kTDocArchiverOutput.db3 .......................... 49
Roche Diagnostics
4 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Roche Diagnostics
Operator´s Manual · Version 1.3 5
cobas 6000 TraceDocArchiver
Document information
Document information
Revision history
Edition notice This Operator´s Manual is for users of the cobas 6000 TraceDocArchiver.
Every effort has been made to ensure that all the information contained in this
document is correct at the time of printing. However,
Roche Diagnostics International Ltd reserves the right to make any changes
necessary without notice as part of ongoing product development.
Any customer modification to the software will render the warranty or service
agreement null and void.
Intended use cobas 6000 TraceDocArchiver (the program) allows a user to process cobas 6000
analytical system *) backup files to derive sample result dependency information to
trace reagent, control and calibration material use as well as time based dependency
of sample results from calibration- and control measurements.
*) Future program updates may add support for more instruments.
Local regulation Regional restrictions and obligations may apply as per contract or license agreement
for the usage the user has agreed to oblige when using this program.
Copyright © 2016 Roche Diagnostics International Ltd. All rights reserved.
Trademarks The following trademarks are acknowledged:
COBAS, COBAS C, COBAS INTEGRA, ELECSYS and LIFE NEEDS ANSWERS are
trademarks of Roche.
All other trademarks are the property of their respective owners.
Limited warranty
For US customers only.
Roche Diagnostics warrants that this product will meet the specifications stated in the
labeling when used in accordance with such labeling and will be free from defects in
material and workmanship until the expiration date printed on the label.
This limited warranty is in lieu of any other warranty, express or implied, including
any implied warranty of merchantability or fitness for particular purpose. In no event
shall Roche Diagnostics be liable for incidental, indirect, special or consequential
damages.
Distribution in USA by:
Roche Diagnostics, Indianapolis, IN,
US Customer Technical Support 1-800-428-2336
Manual Version Software Version Revision date Changes
1.0 1.0.0 November 2013 Initial version
1.1 1.02 September 2015 Update sw version,
add new messages.
1.3 1.03 Jamuar 2016 Update sw version,
add purge icon and
description
Roche Diagnostics
6 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Welcome to cobas 6000 TraceDocArchiver
Welcome to cobas 6000 TraceDocArchiver
Preface
The cobas 6000 TraceDocArchiver (the program) allows a user to process backup
files from one or more cobas 6000 instrument *), to derive sample result dependency
information to trace reagent, control and calibration material use as well as time
based dependency of sample results from calibration- and control measurements.
Regional restrictions and obligations may apply as per contract or license agreement
for the usage the user has agreed to oblige when using this program.
*) Future program updates may add support for more instruments.
Figure 1 Basic workflow
cobas 6000 CU
backup
file
TraceDoc
Base
TraceDoc
cobas 6000 TraceDocArchiver
Daily Essential Data
Backup (Level 4)
Customer PC
S
V
P
_
T
R
A
N
S_
4
_
Y
Y
Y
Y
M
M
D
D
h
h
m
m
.
z
i
p
c
o
b
a
s
6
0
0
0
T
r
a
c
e
D
o
c
d
a
t
a
T
r
a
c
e
D
o
c
V
i
e
w
e
r
f
o
r
c
o
b
a
s
6
0
0
0
Install the program
Once
Define the storage location
Once (or if a storage change is needed)
Define the instruments
Once (or if a new instrument is traced)
Add a backup file
Every day or other interval
Search through traceability information
Whenever needed
Monitor seamless import
At intervals
Archive traceability data
Once per months, quarter (depends on data size)
Roche Diagnostics
Operator´s Manual · Version 1.3 7
cobas 6000 TraceDocArchiver
Welcome to cobas 6000 TraceDocArchiver
Important information
Integrity of input data The program will perform basic checks while backup files are processed, however
there are limitations of the consistency detection by the application.
o Ensure integrity of the data backup files in content and filenames while carrying
them from the instrument to the import function of the program.
Intended usage The program processes data solely for the purpose intended i.e. to derive and
document material use and dependency information.
The only original source of result and measurement data is the fully validated and
qualified IVD device (the instrument).
Dependency tracing The program extracts and stores original and derived data from the backup files.
The dependency of sample results from Calibrations is derived via the timely
sequence of events.
The Last QC measurement before the sample result is derived via the timely sequence
of events.
Completeness The program will only capture information and dependency that is present in the
imported backup file.
o Backup data before deleting data. Otherwise, the information will not be available
in the trace records and the dependency may not be accurate.
Privacy The backup files from the instruments may contain patient privacy information.
Backup files are stored at the designated location.
o Ensure the designated location is adequate to store privacy information.
The derived traceability information carries Operator IDs. It does not contain
patient related information other than the Sample ID.
Roche Diagnostics
8 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Welcome to cobas 6000 TraceDocArchiver
System requirements
The cobas 6000 TraceDocArchiver:
o Windows PC hardware
o Windows 7 operating system
o Microsoft Visual C++ 2010 SP1 Redistributable Package
x86 or x64 version depending on whether the 32bit or 64bit version of Windows
is installed.
o Microsoft .NET Framework 4 (Runtime)
o Microsoft .Net Framework (Web Installer)
o CD/DVD Writer optional for archiving
o Approx. 1 GB harddisk space to archive cobas 6000 analytical system data over
time
Package content
o Software CD-ROM containing
O the cobas 6000 TraceDocArchiver software installation program
O this Operator´s Manual as PDF file
o Installation short guide
Roche Diagnostics
Operator´s Manual · Version 1.3 9
cobas 6000 TraceDocArchiver
Starting the program
Starting the program
Start the program like any other Windows program.
The program will start with the screen shown as below.
e
For information about installing the program, see Installing the cobas 6000
TraceDocArchiver on page 29.
Figure 2 Main screen
Roche Diagnostics
10 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
User interface overview
User interface overview
A Heading area
Shows basic information about the program (user, file locations)
B Message area
Important or error messages are listed here
C Tab selection area
To select from the available functions and features
D Tab content area
Content shown depends on the tab.
e
For a more detailed description, see:
Import/Drop on page 13
Imports history on page 18
Export on page 20
Configuration on page 23
Figure 3 User interface overview
A
B
C
D
Roche Diagnostics
Operator´s Manual · Version 1.3 11
cobas 6000 TraceDocArchiver
User interface overview
The heading area
The heading area shows general information of the program, software version, logged
in user and the storage location of the imported files and the derived (TraceDoc)
information.
The user currently logged in.
The laboratory name can be set by the user in Configuration.
The location of the original backup file archive. Clicking the right icon will open the
location in the Windows file explorer.
The location where the derived information (TraceDoc) is stored. Clicking the right
icon will open the location in the Windows file explorer.
The Grand Total of records collected with this application.
Figure 4 Heading example
Figure 5 User
Figure 6 User lab
Figure 7 Location of the original backup file
Figure 8 Location of the derived information
Figure 9 Total output data
Roche Diagnostics
12 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
User interface overview
The error/information area
Messages as described in Appendix B may be shown here if needed.
e
For more information about the System Messages, see Appendix B (System Message
messages) on page 36.
The tab navigation area
There are 6 tabs to navigate (clicking will change from one to the other):
Import/Drop Primary working area (to import cobas 6000 instrument backup files)
Imports history Review the history of imported backup files. Re-Import a complete section.
Export Export data for archival purposes
Misc General purpose location (browse Audit files and purge old data from the data
storage)
Configuration Setup instruments, locations and some general parameters
Instruments Review the instrument configuration known by the application (derived from already
imported backup files).
The tab content area.
e
For a more detailed description about the various tabs available, see:
Import/Drop on page 13
Imports history on page 18
Export on page 20
Configuration on page 23
Misc (maintenance) on page 26
Figure 10 Error/Information area
Figure 11 Navigation tabs
Roche Diagnostics
Operator´s Manual · Version 1.3 13
cobas 6000 TraceDocArchiver
Import/Drop
Import/Drop
First run
At first run, the user will be asked to provide a location for the application's data store
(Archiver Data Store).
By clicking the Exit button, the application will exit because it cannot run without a
data store. The Provide path button will open a dialog from where the user will be
able to choose the location of a new or an old data store. Several actions are imposed
of a data store like checking the availability of the location, write rights and the
version of the database, if it is present already.
If an action fails, a message appears depending on which one failed (#1001 or #1002
or #1003 or #1004 or #1005 or #1006 or #1007).
After selecting a location for the data store, the application will prepare the location
for proper usage without any additional configuration needed. As all things are now
in place, the application will start.
Figure 12 Data store location is not defined
Figure 13 Select a data store location
Before importing a SVP file for the first time, an instrument must be created. For learning
how to create instruments, check Configuration.
Roche Diagnostics
14 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Import/Drop
Import a SVP (backup) file
A Single Import button
On the Import/Drop tab, the single import will take place by drag and drop of an
SVP file over the import button or by clicking the button and selecting the SVP file
from the dialog (See Figure 15). This dialog contains a filter to help us to find more
easily the files which contain a proper filename for import.
When you drag and drop an SVP file or clicking the import button, the application
will check for the presence of instruments and if the database is not already in use by
other external applications.
Figure 14 Import/Drop tab (Single Import button)
A
Figure 15 Open dialog for a SVP file selection
Roche Diagnostics
Operator´s Manual · Version 1.3 15
cobas 6000 TraceDocArchiver
Import/Drop
As the import starts, several actions are performed by the application. If a validation
fails, a proper message will be shown (#1010 or #1006).
As it can be viewed from Figure 16, the import operation is providing detailed
information along with its progress. Also, the Import button changes into Cancel
button. Import can be canceled at any time during import by clicking the Cancel
button.
In order to import successfully a file it is important to respect a couple of validation
rules like:
The filename must have the following format.
o SVP_TRANS_4_Date (YYYYMMDD) Time (HHMM) (e.g.
SVP_TRANS_4_201302261727.zip)
o The zip must not be archived in another zip
o The zip must contain all mandatory files
In case the file does not pass one of the previous validation rules a specific message
will be shown on the Import/Drop tab.
Figure 16 View during a normal import
Roche Diagnostics
16 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Import/Drop
Multiple instruments defined
A slight change in the flow is when there are more instruments defined. In this case,
another dialog appears after the SVP file was selected, allowing you to select a specific
instrument for import.
When importing for the first time and multiple instruments are defined, no
instrument is pre-selected. If an import was already performed for the module
information contained in the archive then that instrument will be pre-selected in the
dialog (See Figure 17).
If the user imports an SVP file which can easily be associated with an instrument by
the application, by default, the multiple instruments selection doesn't appear. To
make it appear, a change in the Configuration tab must be performed.
e
See Instrument Management on page 24.
Figure 17 Select an instrument when importing
Roche Diagnostics
Operator´s Manual · Version 1.3 17
cobas 6000 TraceDocArchiver
Import/Drop
Mass import
A Mass Import button
After clicking Mass Import button a window appears (See Figure 19). The user
selects a file from a folder. All valid and new SVP files from that folder are imported.
New SVP file means it hasn't been imported before regardless of the instrument. The
valid SVP files existent in the folder will be imported in chronological order.
The validation rules are those presented before.
e
See Import a SVP (backup) file on page 14.
Figure 18 Import/Drop tab (Mass Import button)
A
Figure 19 Mass import folder selection
Roche Diagnostics
18 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Imports history
As it can be viewed from Figure 20, a secondary progress indicator appeared,
specifying the current SVP that the application is importing and, also, the total
number of SVP files to be imported.
Imports history
All the imports for each instrument of a data store are recorded and their outcome
can be viewed in the Imports history tab.
The left panel represents the data regarding all the imports for an instrument. The
right panel is the re-import functionality.
e
For more information about the re-import functionality, see Re-import on page 19.
Figure 20 Import progress during mass import
Figure 21 Imports history tab view
Roche Diagnostics
Operator´s Manual · Version 1.3 19
cobas 6000 TraceDocArchiver
Imports history
To view the status for an imported SVP file, user must first select an instrument and
then select a date in the calendar corresponding to the creation date of the SVP file.
The import status for that import is shown in the review import section.
For example, for instrument 0002, an import had been performed using the SVP file
from 7th of September 2011.
Re-import
Re-import process consists in recreating the TraceDoc files that correspond to SVP
files with creation dates within the selected period.
Important During Re-import process all existing TraceDoc files will be deleted, and only the
TraceDoc files that correspond to SVP files with creation dates within the selected
period will be recreated.
The selected period will be the one from the selected date at 12:00 AM to present. On
the calendar, all dates corresponding to the creation date of the imported SVP files
are greyed, regardless of instrument.
To re-import, user must first select a start date then press the Re-import button. A
warning dialog will be displayed (#1012) and the user will be able to cancel this
action.
If user continues with this action, Import tab will be displayed and all SVP files
within the period will be re-imported.
If there is no SVP file imported within the selected period, an information message is
shown (#1011) and the process doesn't start.
For example, having ten SVP files imported since the selected date until present, for
an instrument, all ten SVP files will be re-imported. And this happens for all
instruments in the data store. The re-import doesn't delete imports history or stored
SVPs.
Figure 22 Imports performed for instrument 0000
Roche Diagnostics
20 Operator´s Manual · Version 1.3
cobas 6000 TraceDocArchiver
Export
Export
Export is a way to free up space from the file system of a specific data store and in the
same time to have the data backed-up on the selected medium. It means moving all
the xmls for the corresponding instruments and TraceDocViewer to a different
location. There are two ways of exporting: optical export (to a CD/DVD and Network
export) to another location in the network.
TraceDoc archive size is shown before and after each export. Press Calculate export
size button to obtain the latest export size. Also, there are zones for selecting dates for
exporting.
Taking the tip in consideration, this means that, by selecting certain dates, only the
data created between the two selected dates will be exported.
Also, each export view has a button for triggering the export, enabled only after some
validations are passed. These validations depend on the export type (CD/DVD or
Network), except the condition regarding Export Size.
This means that the export size must be greater than zero. The user must start the
calculation by click the button Calculate export size. If the size is already calculated
and it does not need to be updated, the button is disabled.
Optical export
A Export to a CD/DVD
B Calculate export size button
For the export - the selected dates in the calendar correspond to the dates specified by the
folder's name from TraceDoc folder and not the creation dates for the SVP files.
Figure 23 Optical export view with size not updated
A
B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Roche cobas e 601 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI