Installation Instructions for Atlas Sound M1000 Speakers
1. Afterremovingspeakersfrombox,liftthehangbracketsupwardandtogether.
2. EACHSPEAKERHASASTEPPEDVOLUMECONTROL.TURNTHEVOLUMECONTROL
(Wattage)TO1.0ONEVERYSPEAKERUNLESSOTHERWISENOTEDONDRAWINGS.THISISVERYIMPORTANT.
3. Theperforatedsideoftheenclosurefacesthestructuralceiling.
4. Hangthespeakerssothebottomoftheenclosureisapproxima tely6”to1footabovetheacoustictile.Thisis
standardforplenumsupto4’inheight,butmayvarywithdifferentplenumcharacteristics.For
higherplenums
oruniqueplenums,desiredhanginglevelwillbenotedondrawings.Chain(supplied)willberequiredinmany
casestoreachthedesiredhanginglevel.
5. Speakersmustallbehungtothesamelevelunlessnotedonthedrawings.
6. Speakersmustbeanchoreddirectlyto
theconcreteceilingorq‐deck.
7. Speakersmusthangbalancedsospeakerfaceisstraightupnotatanangle.
8. Ifthereareplenum"obstacles"inyourwaymovethespeakerabittotheleftorrighttoallowforproper
hangingandsounddispersion.
9.
Theclearertheplenumareaabovethespeakerthebetterthesounddispersion.
10. Speakersareinstalledona15footgridsoifyouadjusttheinstallationlocationforonespeaker,trytobalance
thenext.Pleasenotechangesonthedrawing.
11. Ifbalancingthedistancebetween
speakersisnotpossible,dothebestyoucan.
12. FT4,2conductor,nonshielded18gaugewiremustbeusedunlesstheinstallisininnerVancouverorOntario,in
whichcaseFT6,2conductor,nonshielded18gaugewiremustbeused.NOEXCEPTIONS
13. Wirethespeakersinparallel,asshownonthedrawing.
Allwiringmustberunneatly,noslackwiring.Thefinal
homerungoestotheelectrical/telephone/communicationroom(wherethesoundequipmentwillbeinstalled)
asshownonthedrawing.Speakersmustbecontinuouslywiredinadaisychainprocess.
14. Runthewiresdownthewalltothehead
equipment,attachingwirestothewallorrunningdownthroughthe
wall.
15. Ifwiringisalteredfromlayoutsupplied,pleasesendas‐builtstoVibra‐Sonic
16. LabelwireendsSoundMasking,Floor&Zone(accordingtothedrawing)foreasyconnectiontothehead
equipment.(ie.
SM,F10,Z5).Leaveaminimumof25’ofhomerunslackwireneatlycoiledfor termination.