Coyote C2C34NG Installation guide

Category
Barbecues & grills
Type
Installation guide

This manual is also suitable for

www.coyoteoutdoor.com
DIMENSIONAL RENDERINGS
Model No. Gas Supply BTU's Regulator WC Pressure Max PSI Electrical Requirements
C2C34LP Propane 60,000
1/2" Female Pipe
11" .5 PSI Qty 1 - 120 VAC 60 Hz Grounded Plug
C2C34NG Natural Gas 60,000
20 lb Tank Regulator
4" .5 PSI Qty 1 - 120 VAC 60 Hz Grounded Plug
Model No. Height Width Depth
Model No. Height Width Depth
C2C34
31"
C2C34
23" 34"
CJAKTCC3
11"
CJAKTCC3
23"
Cutout Dimensions for Island
Overall Product Dimensions
When using a Coyote insulated jacket, you will want to build your island to the jackets Cutout and Overall Dimensions
listed above (detailed on 2nd page). Once the jacket is installed, the grill will rest on/inside the insulated jacket
34
1
/4"
20
1
/2"
25
1
/2"
10
1
/4"
11"
36
1
/8"
22
1
/8"
Important Note to Installer: This file is not intended to replace your Owners' Manual which contains specific safety
requirements and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in grill.
C2C34 INSTALL GUIDE
11"
23"
34
1
/4"
11"
36
1
/8"
22
1
/8"
www.coyoteoutdoor.com
C2C34 INSTALL GUIDE
10
1
/4"
OPENING
HEIGHT
DOORS / DRAWERS
OPENING WIDTH
20
1
/2"
OPENING
DEPTH
OPENING
HEIGHT
GRILL
OPENING
GRILL
OVERHANG
TOP VIEW
31"
OPENING WIDTH
2
1
/2"
OPENING
HEIGHT
DOORS / DRAWERS
OPENING WIDTH
OPENING
DEPTH
OPENING
HEIGHT
24"
LINER
OPENING
7
/8"
JACKET
OVERHANG
TOP VIEW
OPENING WIDTH
24"
FRONT VIEW
FRONT VIEW
1
1
/2" MIN
INCLUDING
COUNTERTOP
Combustible material can not be within 24" of the grills frame
This applies to all directions - horizontal & vertical
Shaded area above on "TOP VIEW" illustrates the 24" minimum
requirement (not to scale for rendering purposes)
The grill is designed to hang from the counter top with no support
underneath
Minimum rear clearance for the hood to open is 2"
If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust
24"
If using combustible material within 24" of the grill frame, you MUST use
the corresponding Coyote Insulated Jacket
Using a insulated jacket, does not waive any other standard installation
procedure (ventilation, connections, etc)
The jacket is designed to hang from the counter top with no support
underneath
Minimum clearance for hood to open is 2"
If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust
Ventilation Requirements:
Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within
the island.
These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.
For a propane setup, the vents should be installed lower as propane is heavier than air.
For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.
Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped
gas to dissipate.
1
1
/2"
1
5
/8"
1
1
/2"
22
1
/8"
1
1
/2" MIN
7
/8"
11"
INCLUDING
COUNTERTOP
34
1
/4"
1
3
/4"
2
1
/2"
2
1
/2"
2"
G
GAS
CONNECTION
G
4
1
/8"
4
1
/8"
G
GAS
CONNECTION
4
1
/8"
G
2
3
/4"
Important
Note to
Installer:
This file is
not intended to replace your Owners' Manual which contai
ns specific safety
requirements and consumer guidelines. Please refer to your
Owners' Manual prior to installing or operating your built-in grill.
NON-COMBUSTIBLE CONSTRUCTION
Insulated Jacket NOT Required
COMBUSTIBLE CONSTRUCTION
Insulated Jacket Required - Model # CJAKTCC3
  • Page 1 1
  • Page 2 2