Lenze Global Drive 9321 Servo PLC Mounting instructions

Category
Supplementary music equipment
Type
Mounting instructions
Mounting Instructions
EDS9300OUEI
00411918
Global Drive
9300 Servo PLC
Show/Hide Bookmarks
These Instructions are valid for 93XXcontrollers as of version:
33.93XX- EI 2x. 0x (9321 - 9332)
33.93XX- CI 2x. 0x (9321 - 9328)
Type
Design:
Ex = Enclosure IP20
Cx = Cold Plate
xI = Servo PLC
xK = Cam profiler
xP = Position controller
xR = Register controller
xS = Servo inverter
Hardware version and index
Software version and index
Version
Explanation
What is new / what has changed?
Material No. Version Important Contents
411918 1.0 10/99 TD06 1st edition
9
8
1.4 05/01 TD02 2nd edition
E2001 Lenze GmbH & Co KG
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze GmbH & Co KG.
AllindicationsgivenintheseOperatinginstructionshavebeenselectedcarefullyandcomplywiththehardware andsoftware described.Nevertheless, devia-
tions cannot be ruled out. We do not take any responsibility or liability for damages which might possibly occur. We will include necessary correctionsin
subsequent editions.
Show/Hide Bookmarks
P E
M a i n s c o n n e c t i o n
a n d D C c o n n e c t i o n
D e t a c h a b l e o p e r a t i n g m o d u l e
a l t e r n a t i v e l y
F i e l d b u s e s
I N T E R B U S
S y s t e m b u s ( C A N )
D i g i t a l f r e q u e n c y i n p u t
E n c o d e r i n p u t
R e s o l v e r i n p u t
D i g i t a l f r e q u e n c y o u t p u t
M o t o r c o n n e c t i o n
U V W
R D Y I M P I m a x M m a x F a i l
1
2
7
6 2
3
4
7
6 3
A 4
S T 2
5 9
S T 1
A 3
A 2
A 1
E 3
E 5
3 9 E 4 E 2 E 1 2 8
G N D
L O
H I
M C T R L - N - A C T
X 4
X 5
X 6
X 8
X 9
P E
P T C
U V W
L 1
L 2
L 3
+ U G
- U G
X 1 0
T 1 T 2
1
5
5
1
5
1
1
5
S h i e l d c o n n e c t i o n
1 2 5 0
r p m
X 7
S h i e l d p l a t e m o t o r c a b l e s
S h i e l d p l a t e c o n t r o l c o n n e c t i o n
s
S h i e l d p l a t e m a i n s c o n n e c t i o n
X 1 ( h i d d e n ) :
A u t o m a t i o n i n t e r f a c e
X 1
P T C c o n n e c t i o n
C o n t r o l t e r m i n a l s
Show/Hide Bookmarks
Contents
i
LMA9300PLC EN 1.4
1 Preface and general information 1-1...........................................
1.1 The 9300 Servo PLC 1-1..............................................................
1.2 About these Instructions 1-2............................................................
1.2.1 Terminology used 1-2.........................................................
1.3 Packing list 1-2.....................................................................
1.4 Legal regulations 1-3.................................................................
2 Safety instructions 2-1......................................................
2.1 General safety and application notes for Lenze controllers 2-1...................................
2.2 Layout of the safety instructions 2-2......................................................
2.3 Residual hazards 2-2.................................................................
3 Technical data 3-1.........................................................
3.1 Features 3-1.......................................................................
3.2 General data/operating conditions 3-2....................................................
3.3 PLC functionality 3-3.................................................................
3.4 Rated data 3-4......................................................................
3.4.1 Types 9321 to 9325 3-4........................................................
3.4.2 Types 9321 to 9324 with 200 % overcurrent 3-5.....................................
3.4.3 Types 9326 to 9332 3-6........................................................
3.4.4 Fuses and cable cross-sections 3-7...............................................
3.4.5 Mains filter 3-8..............................................................
3.5 Dimensions 3-8.....................................................................
Show/Hide Bookmarks
Contents
ii L
MA9300PLC EN 1.4
4 Installation 4-1............................................................
4.1 Mechanical installation 4-1.............................................................
4.1.1 Important notes 4-1...........................................................
4.1.2 Standard mounting with fixing rails or mounting brackets 4-2............................
4.1.3 Mounting with thermally separated power stage
(push-through technique) 4-3..................................................
4.1.4 Variant mounting 4-6..........................................................
4.2 Electrical installation 4-9..............................................................
4.2.1 Protection of persons 4-9.......................................................
4.2.1.1 Residual-current circuit breakers 4-9....................................
4.2.1.2 Isolation 4-10.......................................................
4.2.1.3 Replacement of defective fuses 4-10.....................................
4.2.1.4 Mains disconnection 4-10..............................................
4.2.2 Controller protection 4-11.......................................................
4.2.3 Motor protection 4-11..........................................................
4.2.4 Mains types/conditions 4-12.....................................................
4.2.5 Interaction with compensation equipment 4-12........................................
4.2.6 Specification for all cables used 4-12...............................................
4.2.7 Power connections 4-13........................................................
4.2.7.1 Mains connection 4-13................................................
4.2.7.2 Motor connection 4-15................................................
4.2.7.3 Connection of a brake unit 4-17.........................................
4.2.7.4 DC-bus connection of several drives 4-18..................................
4.2.8 Control connections 4-20........................................................
4.2.8.1 Control cables 4-20..................................................
4.2.8.2 Assignment of control terminals 4-20.....................................
4.2.8.3 Connection diagrams 4-22.............................................
4.2.9 Motor temperature monitoring 4-28................................................
4.2.9.1 User-specific characteristic for a PTC thermistor 4-29.........................
4.2.10 Feedback systems 4-30.........................................................
4.3 Installation of a CE-typical drive system 4-33................................................
5 Commissioning 5-1........................................................
5.1 General 5-1........................................................................
5.2 Before switching on 5-1...............................................................
5.3 Initial switch-on 5-4..................................................................
5.4 Switch-on sequence 5-4...............................................................
5.5 Input of motor data 5-6...............................................................
5.6 Motor selection list 5-7...............................................................
5.6.1 Keypad 5-10.................................................................
5.6.2 Parameter change 5-12.........................................................
5.6.3 Parameter saving 5-13.........................................................
5.6.4 Load parameter 5-13...........................................................
6 Troubleshooting and fault elimination 6-1.......................................
6.1 Troubleshooting 6-1..................................................................
6.2 Reset of error messages 6-2...........................................................
6.3 Error messages 6-3..................................................................
Show/Hide Bookmarks
Contents
iii
LMA9300PLC EN 1.4
7 Appendix 7-7.............................................................
7.1 Table of keywords 7-7................................................................
Show/Hide Bookmarks
Contents
iv L
MA9300PLC EN 1.4
Show/Hide Bookmarks
Preface and general information
1-1
LMA9300PLC EN 1.4
1 Preface and general information
1.1 The 9300 Servo PLC
We would like to congratulate you to the 9300 PLC.
For the first time in drive technology, the 9300 Servo PLC by Lenze integrates PLC technology into
a controller - and all that without additional hardware.
In addition to drive control it is now possible to load and execute PLC programs because the PLC
functionality is integrated into the operating system of the 9300 Servo PLC.
ItispossibletoprogramthecontrollerinthesamewayasyouareusedtofromyourPLCenvironment
because programming is based on the IEC1131-3 standard.
Together with the program package “Drive PLC Developer Studio” (DDS) we provide a very
comfortable PLC development system. Among others it includes the following:
Editors for the five IEC1131-3 programming languages
Extensive monitoring and debugging functions
Commissioning visualisation
Your automation tasks can now be solved where they occur.
The 9300 Servo PLC offers a highly dynamic and precise servo controller for the following motors
Synchronous servo motors
Asynchronous servo motors
Standard asynchronous motors
Select one of the following feedback systems
Resolver
Incremental encoder
SinCos encoder
Absolute value encoder
Additional components like the low-backlash gearbox, optimized motors and fieldbus and drive
connections offer complete drive solutions.
Show/Hide Bookmarks
Preface and general information
1-2 L
MA9300PLC EN 1.4
1.2 About these Instructions
These Instructions help to mount and test the 93XXServo PLC. The default setting for the
controller is configuration 1010. The chapter Commissioning (^5-1) gives instructions how to
easily and quickly test the 93XXServo PLC and the connected motor.
Please observe the safety notes given in these Instructions.
All persons working on and with the Servo PLC must have the Instructions available and must
observe the information and notes relevant for their work.
The Mounting Instructions must always be in a complete and perfectly readable state.
Further information about the controller can be obtained from the Catalog and the Manual.
1.2.1 Terminology used
Term In the following text used for
93XX Any servo controller of type 9321 ... 9332
Controller 93XX Servo PLC
Drive system Drive systems with Servo PLC 93XX and other Lenze drive components
DDS Drive PLC Developer Studio, software tool for the development of PLC programs
GDC Global-Control (software tool for parameter setting of drives)
1.3 Packing list
Packing list Important
1 93XX Servo PLC
1 Mounting Instructions
1 accessory kit (bits and pieces for
mechanical and electrical
installation)
After receipt of the delivery, check immediately whether the items delivered match the
accompanying papers.Lenze does not accept any liability for deficiencies claimed subsequently.
Claim
visible transport damage immediately to the forwarder.
visible deficiencies/incompleteness immediately to your Lenze representative.
àThe following is required for programming the 93XX Servo PLC
– DDS (Drive PLC Developer Studio)
– 1 System bus adapter
These tools are not included in the packing list.
Show/Hide Bookmarks
Preface and general information
1-3
LMA9300PLC EN 1.4
1.4 Legal regulations
Labelling Nameplate CE-identification Manufacturer
g
Lenze controllers are unambiguously
designated by the contents of the nameplate. Conforms to the EC Low-Voltage Directive Lenze GmbH & Co KG
Postfach 101352
D-31763 Hameln
Application as
directed 93XX Servo PLC
must only be operated under the conditions prescribed in these Instructions.
are components
– for open and closed loop control of variable speed drives with PM synchronous motors, asynchronous servo motors or asynchronous
standard motors.
– for installation in a machine
– used for assembly together with other components to form a machine.
are electric units for the installation into control cabinets or similar enclosed operating housing.
comply with the requirements of the Low-Voltage Directive.
are not machines for the purpose of the Machinery Directive.
are not to be used as domestic appliances, but only for industrial purposes.
Drive systems with 93XX Servo PLC
comply with the EMC Directive if they are installed according to the guidelines of CE-typical drive systems.
can be used
– for operation on public and non-public mains
– for operation in industrial premises and residential areas.
The user is responsible for the compliance of his application with the EC directives.
Any other use shall be deemed as inappropriate!
Liability The information, data, and notes in these instructions met the state of the art at the time of printing. Claims on modifications referring to
controllers which have already been supplied cannot be derived from the information, illustrations, and descriptions.
The specifications, processes, and circuitry described in these instructions are for guidance only and must be adapted to your own specific
application. Lenze does not take responsibility for the suitability of the process and circuit proposals.
The specifications in these Instructions describe the product features without guaranteeing them.
Lenze does not accept any liability for damage and operating interference caused by:
– disregarding the operating instructions
– unauthorized modifications to the controller
– Operating errors
– improper working on and with the controller
Warranty Warranty conditions: see Sales and Delivery Conditions of Lenze GmbH & Co KG.
Warranty claims must be made to Lenze immediately after detecting the deficiency or fault.
The warranty is void in all cases where liability claims cannot be made.
Disposal Material recycle dispose
p
Metal D-
Plastic D-
Assembled PCBs -D
Show/Hide Bookmarks
Preface and general information
1-4 L
MA9300PLC EN 1.4
Show/Hide Bookmarks
Safety instructions
2-1
LMA9300PLC EN 1.4
2 Safety instructions
2.1 General safety and application notes for Lenze controllers
(according to Low-Voltage Directive 73/23/EWG)
1. General
Lenze controllers (frequency inverters, servo inverter, DC controllers) can carry a voltage or parts of the controllers can rotate during operation. Surfaces can be hot.
If the required cover is removed, the controllers are used inappropriately or installed or operated incorrectly, severe damage to persons or material assets can occur.
For more information please see the documentation.
All operations concerningtransport, installation, and commissioning as well as maintenance must be carried out by qualified, skilled personnel (IEC 364 and CENELEC HD
384 or DIN VDE 0100 and IEC report 664 or DIN VDE 0110 and national regulations for the prevention of accidents must be observed).
According to this basic safety information qualified, skilled personnel are persons who are familiar with the assembly, installation, commissioning, and operation of the
product and who have the qualifications necessary for their occupation.
2. Application as directed
Drive controllers are components which are designed for the installation into electrical systems or machinery. They are not to be used as domestic appliances, but only
for industrial purposes according to EN 61000-3-2. The documentation contains information about the compliance of the limit values to EN 61000-3-2.
When installing controllers into machines, commissioning of the drive controllers (i.e. the starting of operation as directed)is prohibited until it is proven that the machine
corresponds to the regulations of the EC Directive 98/37/EG (Machinery Directive); EN 60204 (VDE 0113) must be observed.
Commissioning (i.e. starting of operation as directed) is only allowed when there is compliance with the EMC Directive (89/336/EWG).
The drive controllers meet the requirements of the Low-Voltage Directive 73/23/EWG. The harmonised standards EN 50178/DIN VDE 0160 apply to the controllers.
The technical data as well as the connection conditions can be obtained from the nameplate and the documentation. The instructions given must be strictly observed.
Warning: Controllers are products with restricted availability according to EN 61800-3. These products can cause interferences in residential premises. If controllers are
used in residential premises, corresponding measures are required.
3. Transport, storage
The notes on transport, storage and appropriate handling must be observed.
Climatic conditions according to EN 50178 apply.
4. Installation
The controllers must be installed and cooled according to the regulations given in the corresponding Instructions.
Ensure careful handling and avoid mechanical overload. Do not bend any components and do not change the insulation distances during transport and storage. Electronic
components and contacts must not be touched.
Controllers contain electrostatically sensitive components which can easily be damaged by inappropriate handling. Do not damage or destroy any electrical components
since this could mean hazards for your health!
5. Electrical connection
When working on live controllers, the valid national regulations for the prevention of accidents (e. g. VBG 4) must be observed.
The electrical installation must be carried out in compliance with the corresponding regulations (e.g. cable cross-sections, fuses, PE connection). Additional notes and
information can be obtained from the corresponding Instructions.
The Instructions contain notes concerning wiring according to EMC regulations (shielding, earthing, filters and cable routing). These notes must also be observed when
using CE-marked controllers. The compliance with limit values required by the EMC legislation is the responsibility of the manufacturer of the machine or syst
6. Operation
If necessary, systems including controllers must be equipped with additional monitoring and protection devices according to the applying safety regulations (e.g. regulation
for technical equipment, regulation for the prevention of accidents). The controller can be adapted to your application. Please observe the corresponding information given
in the Instructions.
After a controller has been disconnected from the voltage supply, all live components and power connections must not be touched immediately because capacitors can
still be charged. Please observe the corresponding stickers on the controller.
All protection covers and doors must be shut during operation.
Note for UL-approved systems with integrated controllers: UL warnings are notes which only apply to UL systems. The Instructions give UL-related information.
7. Safe standstill
The variant V004 of 9300 and 9300 vector, and the variant Bx4x of 8200 vector controllers support the function ”Safe standstill”, protection against unintended start,
according to the requirements of Appendix I No. 1.2.7 of the EC Directive ”Machinery” 98/37/EG, DIN EN 954-1 category 3 and DIN EN 1037. Please observe the notes
on the function ”Safe standstill” given in the corresponding Instructions.
8. Maintenance and service
Please observe the Instructions given by the manufacturer,
and the product-specific safety and application notes in these Instructions.
Show/Hide Bookmarks
Safety instructions
2-2 L
MA9300PLC EN 1.4
2.2 Layout of the safety instructions
All safety instructions have a uniform layout:
The icon characterizes the type of danger.
The signal word characterizes the severity of danger.
The note text describes the danger and gives information on how to prevent dangerous
situations.
Signal word
Note
Icons used Signal words
Warning of
damage to
persons
Warning of
hazardous electrical
voltage
Danger! Warns of impending danger.
Consequences if disregarded:
Death or severe injuries.
Warning of a general
danger Warning! Warns of potential, very hazardous situations.
Possible consequences if disregarded:
Death or severe injuries.
Caution! Warns of potential, hazardous situations.
Possible consequences if disregarded:
Light or minor injuries.
Warning of
damage to
material
Stop! Warns of potential damage to material.
Possible consequences if disregarded:
Damage of the controller/drive system or its environment.
Other notes Tip! This note designates general, useful notes.
If you observe it, handling of the controller/drive system is made easier.
2.3 Residual hazards
Protection of
persons After mains voltage disconnection the power terminals U, V, W and +UG,-U
Gcarry hazardous voltages at least 3 minutes
after mains disconnection.
Before working on the controller, check that no voltage is applied to the power terminals.
Protection of
devices Cyclic connection and disconnection of the controller supply voltage at L1, L2, L3 or +UG,+U
Gmay overload the internal
input current load:
Allow at least 3 minutes between disconnection and reconnection.
Overspeeds Drive systems can reach dangerous overspeeds (e.g. setting high field frequencies for motors and machines which are
not suitable):
The controllers do not offer any protection against these operating conditions. Use additional components for this.
Parameter set
transfer During parameter set transfer, the control terminals of the 9300 servo can have undefined states!
Therefore the plugs X5 and X6 must be removed before transfer. Thus it is ensured that the controller is inhibited and all
control terminals have the defined state ”LOW.
Show/Hide Bookmarks
Technical data
3-1
LMA9300PLC EN 1.4
3 Technical data
3.1 Features
Suitable for the following motors (with corresponding power)
– Synchronous servo motors
– Asynchronous servo motors
– Asynchronous servo motors
Resolver feedback (factory setting)
Encoder feedback
– Incremental encoder TTL
– Sin/cos encoder
– Sin/cos encoder with serial communication (single turn)
– Sin/cos encoder with serial communication (multi turn)
Single axis in narrow design
– space-saving installation
Power range: 370 W to 75 kW
– Uniform control module and thus uniform connection for the control cables over the
complete power range.
Heat sink can be separated
– Cooling is possible outside the control cabinet
(punching or ”Cold Plate”)
Power connections from the top (supply)or from the bottom (motor)
– simple connection for multi-axis applications
Direct connection of resolver or encoder feedback
– Easy connection because of prefabricated system cables (accessories)
– Connecting cables can be plugged
Programmable user configuration through the Lenze ’Drive Developer Studio (DDS)based on
IEC 1131-3.
System bus (CANopen)for
– communication with DDS and GDC
– the expansion of the controller terminals by means of decentralized inputs and outputs
– the connection of a hand terminal or a keypad
– for diagnostics and optimization
– the connection of other controllers
Integrated automation interface for fieldbus systems such as
–INTERBUS
–PROFIBUSetc.
Approval of standard devices UL 508, File No. 132659 (listed)
Approval 9371 BB (BAE)UL 508, File No. 132659 (listed)
Show/Hide Bookmarks
Technical data
3-2 L
MA9300PLC EN 1.4
3.2 General data/operating conditions
Field Values
Vibration resistance Germanischer Lloyd, general conditions
Permissible moisture Humidity class F without condensation
(average relative humidity 85 %)
Permissible temperature ranges during transport: -25 °C ... + 70 °C
during storage of the controller: -25 °C ... + 55 °C
during operation of the controller: 0 °C ... +40 °C without derating
+40 °C ... +55 °C with power derating (controllers 9321-9326)
+40 °C ... +50 °C with power derating (controllers 9327-9332)
Permissible installation height h h1000 m a.m.s.l. without derating
1000 m a.m.s.l. < h 4000 m a.m.s.l. with derating
Permissible pollution VDE 0110 part 2 pollution degree 2
Noise emission Requirements to EN 50081-2, EN 50082-1, EN 61800-3
Limit value class A to EN 55011 (industrial area) with mains filter A
Limit value class B acc. to EN 55022 (residential area) with mains filter B and installation in control cabinet
Noise immunity Limit values maintained using mains filter.
Requirements to EN 50082-2, EN 61800-3
Requirements Standard Severity
Running time EN61000-4-2 3, i.e. 8 kV at air discharge and 6 kV at contact discharge
RF interference
(enclosure) EN61000-4-3 3, i.e. 10 V/m; 27 to 1000 MHz
Burst EN61000-4-4 3/4, i.e. 2 kV/5 kHz
Surge IEC 1000-4-5 3, i.e. 1.2/50 µs, 1 kV phase-phase, 2 kV phase-PE
Insulation strength Overvoltage category III to VDE 0110
Packaging to DIN 4180
9321 to 9332: Delivery packing
Type of protection IP20
IP41 on the heat-sink side for thermal separation (punching)
NEMA 1: Protection against contact
Approvals CE: Low-Voltage Directive
UL508: Industrial Control Equipment
UL508C: Power Conversion Equipment
Show/Hide Bookmarks
Technical data
3-3
LMA9300PLC EN 1.4
3.3 PLC functionality
Field Numbe
rDescription
Inputs digital 1
3
2
Input for controller enable
Free inputs (interruptable, response time 250µs)
Free inputs
24V DC / 8mA per input
analog 2Free inputs (11 bit + sign) ñ10V
Outputs digital 4Free outputs 24V DC / max. 50mA per output
O
u
t
p
u
t
s
analog 2Free outputs (9 bit + sign) ñ10V / max. 2mA
Expandability of digital inputs/outputs Up to 8 system bus modules (9374) with 8 configurable inputs/outputs
Counter/times According to IEC1131-3, depending on the data memory available
Label 1000 label words
Fast counter 10...500 kHz
Program memory ca. 600 kB for approx. 150k instructions
Data memory 16 kB
Processing time 0.7ms (per 1000 binary instructions)
Task 8
1EVENT or INTERVAL tasks (1ms-16s)
Cyclic task
Functions PID control functions
Synchro system
Positioning function
Mains failure control
Brake control
Flow point arithmetik
Networking INTERBUS
PROFIBUS
RS232/RS485
System bus (CANopen)
Others in preparation
E2PROM buffered memory 8kbyte, of which 52 byte in the remanent range
Show/Hide Bookmarks
Technical data
3-4 L
MA9300PLC EN 1.4
3.4 Rated data
3.4.1 Types 9321 to 9325
Type EVS9321-EI EVS9322-EI EVS9323-EI EVS9324-EI EVS9325-EI
Order no. EVS9321-EI EVS9322-EI EVS9323-EI EVS9324-EI EVS9325-EI
Type EVS9321-CI EVS9322-CI EVS9323-CI EVS9324-CI EVS9325-CI
Order no. EVS9321-CI EVS9322-CI EVS9323-CI EVS9324-CI EVS9325-CI
Mains voltage Vr[V] 320 V - 0 % Vr528V+0%; 45Hz-0%... 65Hz+0%
Alternative DC supply VDC [V] 460 V - 0 % VDC 740 V + 0 %
Mains current with mains filter
Mains current without mains filter Ir[A] 1.5
2.1 2.5
3.5 3.9
5.5 7.0
-12.0
16.8
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM) Pr[kW] 0.37 0.75 1.5 3.0 5.5
p
(
p
)
Pr[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8kHz*) Sr8 [kVA] 1.0 1.7 2.7 4.8 9.0
Output power + UDC,-U
DC 2) PDC [kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) Ir8 [A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) Ir16 [A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)1) Imax8 [A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)1) Imax16 [A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I08 [A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I016 [A] 1.7 2.7 4.4 7.8 14.6
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM) Pr[kW] 0.37 0.75 1.5 3.0 5.5
p
(
p
)
Pr[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8kHz*) Sr8 [kVA] 1.2 2.1 3.2 5.8 10.8
Output power + UDC,-U
DC 2) PDC [kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) Ir8 [A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) Ir16 [A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)1) Imax8 [A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)1) Imax16 [A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I08 [A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I016 [A] 1.7 2.7 4.4 7.8 14.6
Motor voltage VM[V] 0-3×VMains
Power loss (operation with Iratedx ) Ploss [W] 100 110 140 200 260
Power derating [%/K]
[%/m] 40 °C < Tamb < 55 °C: 2%/K (not UL approved)
1000 m amsl < h 4000 m amsl: 5%/1000m
Weight m[kg] 3.5 3.5 5.0 5.0 7.5
1) The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% Iratedx
2) When operated under rated load, the controller can supply this power additionally.
*Chopper frequency of the inverter (C0018)
Show/Hide Bookmarks
Technical data
3-5
LMA9300PLC EN 1.4
3.4.2 Types 9321 to 9324 with 200 % overcurrent
Type EVS9321-EI EVS9322-EI EVS9323-EI EVS9324-EI
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM) Pr[kW] 0.37 0.75 1.5 3.0
p
(
p
)
Pr[hp] 0.5 1.0 2.0 4.0
Output power U, V, W (8 kHz) Sr8 [kVA] 1.0 1.7 2.7 4.8
Output current (8 kHz) 2) Ir8 [A] 1.5 2.5 3.9 7.0
Output current (16 kHz) 2) Ir16 [A] 1.1 1.8 2.9 5.2
max output current (8 kHz)1) Imax8 [A] 3.0 5.0 7.8 14.0
max output current (16 kHz)1) Imax16 [A] 2.2 3.6 5.8 10.4
max. standstill current (8 kHz) I08 [A] 3.0 5.0 7.8 14.0
max. standstill current (16 kHz) I016 [A] 2.2 3.6 5.8 10.4
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM) Pr[kW] 0.37 0.75 1.5 3.0
p
(
p
)
Pr[hp] 0.5 1.0 2.0 4.0
Output power U, V, W (8 kHz) Sr8 [kVA] 1.2 2.1 3.2 5.8
Output current (8 kHz) 2) Ir8 [A] 1.5 2.5 3.9 7.0
Output current (16 kHz) 2) Ir16 [A] 1.1 1.8 2.9 5.2
max output current (8 kHz)1) Imax8 [A] 3.0 5.0 7.8 14.0
max output current (16 kHz)1) Imax16 [A] 2.2 3.6 5.8 10.4
max. standstill current (8 kHz) I08 [A] 3.0 5.0 7.8 14.0
max. standstill current (16 kHz) I016 [A] 2.2 3.6 5.8 10.4
1) The currents apply to a periodical load cycle with 10 seconds overcurrent with the current mentio-
ned here and 50 seconds base load with 44 % Irx
Majority in indiv.
cases Settings under
code C0022 Thermal
continuous current Max. current phase Recovery phase
Continuous power Imax 150 % IrX 100 % IrX 150 % IrXfor 60 s 75 % IrX for 120 s
Peak power Imax >150 % IrX 70 % IrX 200 % IrX for 10 s 44 % IrX r 50 s
2) This output current Irx applies for a maximum current to be set under C022 which has not excee-
ded 150% of the rated controller current (nameplate).
If the maximum current is higher than this value, the continuous current reduces automatically to
70% of the original value.
All other data: ^3-4
Tip!
You can change to Imax > 150% IrX only when the controller is inhibited.
Show/Hide Bookmarks
Technical data
3-6 L
MA9300PLC EN 1.4
3.4.3 Types 9326 to 9332
Type EVS9326-EI EVS9327-EI EVS9328-EI EVS9329-EI EVS9330-EI EVS9331-EI EVS9332-EI
Order no. EVS9326-EI EVS9327-EI EVS9328-EI EVS9329-EI EVS9330-EI EVS9331-EI EVS9332-EI
Type EVS9326-CI EVS9327-CI EVS9328-CI
Order no. EVS9326-CI EVS9327-CI EVS9328-CI
Mains voltage Vr[V] 320 V - 0 % Vr528V+0%;45Hz-0%...65Hz+0%
Alternative DC supply VDC [V] 460 V - 0 % VDC 740 V + 0 %
Mains current with mains filter
Mains current without mains filter Ir[A] 20.5
-27.0
43.5 44.0
-53.0
-78.0
-100
-135
-
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM) Pr[kW] 11.0 15.0 22.0 30.0 45.0 55.0 75.0
p
(
p
)
Pr[hp] 15.0 20.5 30.0 40.0 60.0 73.5 100.0
Output power UVW (8 kHz*) Sr8 [kVA] 16.3 22.2 32.6 40.9 61.6 76.2 100.5
Output power + UDC,-U
DC 2) PDC [kW] 010 40500
Output current (8 kHz*) 1) Ir8 [A] 23.5 32.0 47.0 59.0 89.0 110.0 145.0
Output current (16 kHz*) 1) Ir16 [A] 15.3 20.8 30.6 38.0 58.0 70.0 90.0
Max. output current (8 kHz*) Imax8 [A] 35.3 48.0 70.5 88.5 133.5 165.0 217.5
Max. output current (16 kHz*) Imax16 [A] 23.0 31.2 45.9 57.0 87.0 105.0 135.0
Max. standstill current (8 kHz*) I08 [A] 23.5 32.0 47.0 52.0 80.0 110.0 126.0
Max. standstill current (16 kHz*) I016 [A] 15.3 20.8 30.6 33.0 45.0 70.0 72.0
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM) Pr[kW] 11.0 18.5 30.0 37.0 45.0 55.0 90.0
p
(
p
)
Pr[hp] 15.0 25.0 40.0 49.5 60.0 73.5 120.0
Output power UVW (8 kHz*) Sr8 [kVA] 18.5 25.0 37.0 46.6 69.8 87.3 104.0
Output power + UDC,-U
DC 2) PDC [kW] 012 4.8 0 6 0 6
Output current (8 kHz*) Ir8 [A] 22.3 30.4 44.7 56.0 84.0 105.0 125.0
Output current (16 kHz*) Ir16 [A] 14.5 19.2 28.2 35.0 55.0 65.0 80.0
Max. output current (8 kHz*)1) Imax8 [A] 33.5 45.6 67.1 84.0 126.0 157.5 187.5
Max. output current (16 kHz*)1) Imax16 [A] 21.8 28.8 42.3 52.5 82.5 97.5 120.0
Max. standstill current (8 kHz*) I08 [A] 22.3 30.4 44.7 49.0 72.0 105.0 111.0
Max. standstill current (16 kHz*) I016 [A] 14.5 19.2 28.2 25.0 36.0 58.0 58.0
Motor voltage aM[V] 0-3×VMains
Power loss Ploss [W] 360 430 640 810 1100 1470 1960
Power derating [%/K]
[%/K]
[%/m]
9326: at 40 °C < Tamb < 55 °C: 2%/K (not UL approved)
9327 - 9332: at 40 °C < Tamb < 50 °C: 2.5%/K (not UL approved)
1000 m amsl < h 4000 m amsl: 5%/1000m
Weight m[kg] 7.5 12.5 12.5 12.5 36.5 59 59
1) The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% Iratedx
2) When operated under rated load, the controller can supply this power additionally.
*Chopper frequency of the inverter (C0018)
Show/Hide Bookmarks
Technical data
3-7
LMA9300PLC EN 1.4
3.4.4 Fuses and cable cross-sections
Type Mains input L1, L2, L3, PE/motor connection U, V, W Input +UG, -UG
p
Operation without mains filter Operation with mains filter
Fuse E.l.c.b. Cable cross-section
2) Fuse E.l.c.b. Cable
cross-section 2) Fuse Cable
cross-section 2)
VDE UL VDE mm2AWG VDE UL VDE mm2AWG mm2AWG
9321 M6A 5A B6A 117 M6A 5A B6A 117 6.3A 117
9322 M6A 5A B6A 117 M6A 5A B6A 117 6.3A 117
9323 M 10A 10A B 10A 1.5 15 M 10A 10A B 10A 1.5 15 8A 1.5 15
9324 --- --M 10A 10A B 10A 1.5 15 12A 1.5 15
9325 M 32A 25A B 32A 6 9 M 20A 20A B 20A 411 20A 411
9326 --- --M 32A 25A B 32A 6 9 40A 6 9
9327 M 63A 63A -16 635A 35A -10 750A 10 7
9328 --- --50A 50A -16 580A 16 5
9329 --- --80A 80A -25 3100A 25 3
9330 --- --100A 100A -50 02 * 80A 1) 2*16 2*5
9331 --- --125A 125 A -70 2/0 2 *100A 1) 2*25 2*3
9332 --- --160A 175 A -95 3/0 3 *80A 1) 3*16 3*5
1) The DC bus fuses are connected in parallel
2) The valid local regulations must be observed
For operation of the controllers in UL-approved systems:
Use only UL-approved fuses and fuse holders:
– 500 V to 600 V in the mains input (AC)
– 700 V in DC-bus voltage (DC)
The activation characteristic is defined by ”H” or ”K5”.
Use only UL-approved cables.
Tip!
UL-approved fuses and fuse holders can be obtained from, e.g. Bussmann or Ferraz.
Connection of the motor cables
The protection of the motor cables is not necessary for functional reasons.
Refer to the data listed in the table ”Operation with mains filter.
Show/Hide Bookmarks
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79

Lenze Global Drive 9321 Servo PLC Mounting instructions

Category
Supplementary music equipment
Type
Mounting instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI