F-500BAF

Hoshizaki F-500BAF User manual

  • Hello! I am an AI chatbot trained to assist you with the Hoshizaki F-500BAF User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Hoshizaki
“A Superior Degree
of Reliability”
www.hoshizaki.com
Model
F-500BAF
Self-Contained Flaker
Hoshizaki America, Inc.
Number: 73074
Issued: 3-2-1999
Revised: 12-26-2003
SERVICE MANUAL
2
IMPORTANT
Only qualified service technicians should attempt to service or maintain this
icemaker. No service or maintenance should be undertaken until the technician
has thoroughly read this Service Manual.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the
service and maintenance of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call or write to the HOSHIZAKI Technical Support Department for
assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
Web Site: www.hoshizakiamerica.com
Note: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
3
Please review this manual. It should be read carefully before the icemaker is serviced or
maintenance operations are performed. Only qualified service technicians should service and
maintain the icemaker. This manual should be made available to the technician prior to service
or maintenance.
CONTENTS
I. Specifications .................................................................................................................... 5
F-500BAF ........................................................................................................................5
F-500BAF-C..................................................................................................................... 6
II. General Information .......................................................................................................... 7
1. Construction .................................................................................................................7
F-500BAF, F-500BAF-C ............................................................................................. 7
2. Ice Making Unit ............................................................................................................. 8
3. Control Box Layout ....................................................................................................... 9
F-500BAF, F-500BAF-C ............................................................................................. 9
4. Timer Board ................................................................................................................ 10
[a] Solid-State Control .............................................................................................. 10
[b] Timer Board ......................................................................................................... 10
[c] Sequence ............................................................................................................ 11
III. Technical Information ..................................................................................................... 14
1. Water Circuit and Refrigerant Circuit........................................................................... 14
F-500BAF, F-500BAF-C ........................................................................................... 14
2. Wiring Diagram ........................................................................................................... 15
F-500BAF, F-500BAF-C ........................................................................................... 15
3. Sequence of Electrical Circuit .................................................................................... 16
F-500BAF, F-500BAF-C ......................................................................................... 16
4. Timing Chart ............................................................................................................... 21
5. Performance Data ....................................................................................................... 24
F-500BAF ................................................................................................................ 24
F-500BAF-C ............................................................................................................. 25
IV. Service Diagnosis .......................................................................................................... 26
1. No Ice Production ....................................................................................................... 26
2. Low Ice Production ..................................................................................................... 29
3. Other ........................................................................................................................... 30
V. Removal and Replacement of Components .................................................................. 31
1. Service for Refrigerant Lines ...................................................................................... 31
[a] Refrigerant Recovery........................................................................................... 31
[b] Evacuation and Recharge [R-404A] .................................................................... 31
2. Brazing ....................................................................................................................... 32
3. Removal and Replacement of Compressor ................................................................ 33
4. Removal and Replacement of Drier ........................................................................... 34
5. Removal and Replacement of Expansion Valve......................................................... 35
6. Removal and Replacement of Evaporator Assembly ................................................ 36
7. Removal and Replacement of Fan Motor ................................................................... 40
8. Removal and Replacement of Control Water Valve .................................................... 40
4
VI. Cleaning and Maintenance .......................................................................................... 41
1. Preparing the Icemaker for Long Storage ................................................................... 41
2. Cleaning and Sanitizing Instructions .......................................................................... 42
[a] Cleaning Solution ................................................................................................ 42
[b] Cleaning Procedure ............................................................................................ 42
[c] Sanitizing Solution............................................................................................... 43
[d] Sanitizing Procedure - Initial................................................................................ 44
[e] Sanitizing Procedure - Final ................................................................................ 44
3. Maintenance Instructions ............................................................................................ 46
5
I. Specifications
F-500BAF
AC S UP P LY VOLTAG E 115/60/1
COMP R E S S OR 120 V 7.9 R LA 51 L R A
G E AR MOTOR 120 V 1.6 F LA 1/6 HP
F AN MOTOR 120 V 0.85 F LA 1/15 HP
OTHE R 120 V 0.03 A
MAXIMUM F US E S IZE 20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIR C. BR E AKE R (CANADA ONLY) 20 A
MINIMUM CIR CUIT AMP ACITY 20 A
AP P R OXIMATE ICE P R ODUCTION Ambient W ATE R TE MP . (F)
P E R 24 HR . Temp.(F ) 50 70 90
lbs./day ( kg/day ) 70 * 478 (217) 458 (208) 438 (199)
R eference without *marks 80 419 (190) 400 (182) 383 (174)
90 366 (166) * 359 (163) 335 (152)
100 320 (145) 306 (139) * 287 (130)
SHAPE OF ICE Flake
ICE QUALITY Approx. 70% , Ice (90/70F , C onductivity 200 s/cm)
AP P R OX IMATE S TOR AG E CAP AC ITY 250 lbs.
ELECTRIC & WATER CONSUMPTION 90/70F 70/50F
E LE CTR IC W (kW H/100 lbs.) 900 (6.0) 854 (4.3)
P OTAB LE W ATE R 43 (12) 57 (12)
gal./24HR (gal./100 lbs.)
E X TE R IOR DIME NS IONS (W xDxH) 38" x 29" x 36" (965 x 735 x 915 mm)
EXTE RIOR FINISH PVC Coated Galvanized S teel; Galvanized Steel (Rear);
S tainless S teel (Top)
WEIGHT
Net 210 lbs. ( 95 kg ), Shipping 245 lbs. ( 111 kg )
CONNECTIONS - ELECTRIC Permanent Connection
- W ATE R S UP P LY Inlet 1/2" F P T
- DR AIN Drain P an 3/4" F P T
B in Drain 3/4" F P T
ICE MAKING SYSTEM Auger type
HAR VE S TING S YS TE M Direct Driven Auger ( 1/6 HP G ear Motor )
ICE MAKING W ATE R CONTR OL F loat S witch
COOLING WATER CONTROL N/A
B IN CONTR OL S YS TE M Mechanical B in Control ( P roximity S w. )
COMP R E S S OR Hermetic, Model R S 43C 1E -CAA
CONDE NS E R Air-cooled, F in and tube type
E VAP OR ATOR Copper Tube on Cylinder
R E F R IG E R ANT CONTR OL Thermostatic E xpansion Valve
R E F R IG E R ANT CHAR G E R -404A, 1 lb. (470 g)
DE S IG N P R E S S U R E High 460 P S IG , Low 290 P S IG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRE S S OR PROTECTION Auto-reset Overload Protector
G E AR MOTOR P R OTE CTION Manual reset Circuit B reaker
RE FRIGE RANT CIRCUIT PROTE CTION Auto-reset High Pressure Control S witch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop, Spare Fuse
- R E QUIR E D Legs
OP E R ATING CONDITIONS VOLTAG E R ANG E 104 - 127 V
AMB IE NT TE MP . 45 - 100 F
W ATE R S UP P LY TE MP . 45 - 90 F
WATER SUPPLY PRESSURE 10 - 113 PSIG
DR AW ING NO. (DIME NS IONS ) 339850---
We reserve the right to make changes in specifications and design without prior notice.
6
F-500BAF-C
AC S UP P LY VOLTAG E 115/60/1
COMP R E S S OR 120 V 7.9 R LA 51 LR A
G E AR MOTOR 120 V 1.6 F LA 1/6 HP
F AN MOTOR 120 V 0.85 F LA 1/15 HP
OTHE R 120 V 0.03 A
MAXIMUM FUS E S IZE 20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIR C. BR E AKE R (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMP ACITY 20 A
AP P R OXIMATE ICE P RODUCTION Ambient W ATE R TE MP . (F)
P E R 24 HR . Temp.(F ) 50 70 90
lbs./day ( kg/day ) 70 * 431 (196) 415 (188) 398 (181)
R eference without *marks 80 381 (173) 365 (166) 350 (159)
90 336 (152) * 333 (151) 308 (140)
100 295 (134) 283 (128) * 263 (119)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80% , Ice (90/70F , C onductivity 200 s/cm)
AP P R OX IMATE S TOR AG E C AP AC ITY 250 lbs.
E L E C TR IC & W ATE R C ONS U MP TION 90/70F 70/50F
E L E C TR IC W (kW H/100 lbs.) 903 (6.5) 864 (4.8)
P OTAB LE W ATE R 40 (12) 52 (12)
gal./24HR (gal./100 lbs.)
E X TE R IOR DIME NS IONS (W xDxH) 38" x 29" x 36" (965 x 735 x 915 mm)
EXTE RIOR FINISH P VC Coated Galvanized Steel; Galvanized Steel (Rear);
Stainless Steel (Top)
WEIGHT
Net 210 lbs. ( 95 kg ), Shipping 245 lbs. ( 111 kg )
CONNECTIONS - ELECTRIC Permanent Connection
- W ATE R S UP P LY Inlet 1/2" F P T
- DR AIN Drain P an 3/4" F P T
Bin Drain 3/4" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING W ATE R CONTROL Float Switch
COOLING W ATER CONTROL N/A
BIN CONTROL S YSTE M Mechanical Bin Control ( Proximity Sw. )
COMP R E S S OR Hermetic, Model RS 43C1E -CAA
CONDE NS E R Air-cooled, F in and tube type
E VAP ORATOR Copper Tube on Cylinder
R E F R IG E R ANT CONTR OL Thermostatic E xpansion Valve
R E F R IG E R ANT CHAR G E R -404A, 1 lb. (470 g)
DE S IG N P R E S S UR E High 460 P S IG , Low 290 P S IG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRES S OR PROTE CTION Auto-reset Overload Protector
G E AR MOTOR P R OTE CTION Manual reset Circuit B reaker
RE FRIGE RANT CIRCUIT P ROTE CTION Auto-reset High Pressure Control S witch
LOW W ATE R PROTE CTION Float S witch and Timer
ACCESSORIES - SUPPLIED Ice Scoop, Spare Fuse
- R E QUIR E D Legs
OP E R ATING CONDITIONS VOLTAG E R ANG E 104 - 127 V
AMB IE NT TE MP . 45 - 100 F
W ATE R S UP P LY TE MP . 45 - 90 F
W ATE R S UP P LY P R E S S U R E 10 - 113 P S IG
DR AW ING NO. (DIME NS IONS ) 339850---
We reserve the right to make changes in specifications and design without prior notice.
7
II. General Information
1. Construction
F-500BAF, F-500BAF-C
Top Panel
Side Panel
Sliding Door
Water Supply Inlet
Control Water Valve
Reservoir
Evaporator
Condenser
Condenser Fan
Spout
Gear Motor
Access Valve
Compressor
Control Box
Side Panel
Front Panel
8
2. Ice Making Unit
9
CONTROL
TIMER
CONNECTOR
PRESSURE
SWITCH
TRANSFORMER
WATER CONTROL
RELAY
FLUSH
FLUSH SWITCH
ICE
FUSE
CIRCUIT
BREAKER
OFF
ON
POWER SWITCH
CIRCUIT PROTECT
RELAY
GEAR MOTOR
PROTECT RELAY
CAPACITOR FOR
GEAR MOTOR
CAPACITOR FOR
FAN MOTOR
START
CAPACITOR
RUN
CAPACITOR
STARTER
FLUSH VALVE
CONTROL RELAY
Note: The above component names are identical with the wiring label, but not with the parts list.
3. Control Box Layout
F-500BAF, F-500BAF-C
10
4. Timer Board
[a] Solid-State Control
1) A HOSHIZAKI exclusive solid-state control is employed in the self-contained flaker
icemakers.
2) A printed circuit board (hereafter called “timer board”) includes a stable and high quality
control system.
3) All models are pre-tested and factory adjusted.
[b] Timer Board
CAUTION
1. Fragile, handle very carefully.
2. A timer board contains CMOS (Complementary Metal-Oxide
Semiconductor) integrated circuits, which are susceptible to failure due to
static discharge. It is especially important to use an anti-static wrist strap
when handling or replacing the board.
3. Do not touch the electronic devices on the board or the back of the board to
prevent damage to the board.
4. Do not change wiring and connections. Especially, never misconnect
terminals.
5. Do not fix the electronic devices or parts on the board in the field. Always
replace the whole board assembly when it goes bad.
The icemaker is controlled by the timer board for the following purposes:
1) To prevent the gear motor and the compressor from starting or stopping simultaneously.
2) To reduce remaining ice in the refrigeration casing.
3) To protect the unit in case of low water and low water pressure.
4) To protect the unit in case the bin control causes chattering.
11
Fig. 1
[c] Sequence
Fig. 2
Gear Motor Relay
Compressor Relay
12
Fig. 3
EDOCTRAP10-503734
LEDOM10C441AA2H
GNITARzH06/05CAV42
1T.ces51±06
2T.ces22±09
3T.ces54±051
4Tsselro.ces1
5T%07±.ces7.
6
6T%07±.ces7.6
13
Functions of Terminals
1) Terminals 1, 2
Power supply AC 24V.
2) Terminals 3, 4
Control X1 (GM) and X2 (CM) Relays.
When closed, energize X1 (GM) in 1 sec. and X2 (CM) in 60 sec.
When opened, de-energize X1 (GM) in 150 sec. and X2 (CM) in 90 sec.
3) Terminals 5, 6
Control X1 (GM) and X2 (CM) Relays.
When opened, de-energize X1 (GM) and X2 (CM) immediately.
When closed again, energize X1 (GM) in 1 sec. and X2 (CM) in 60 sec.
4) Terminals 7, 8, 9
X1 (GM) contacts.
8 is a movable contact, 7 is a make contact, and 9 is a break contact.
5) Terminals 10, 11
Control X2 (CM) Relays.
When opened, de-energize X2 (CM) immediately.
When closed, energize X2 (CM) immediately.
Note: 1. X2 Relay is a single pole, normally open relay, and its terminals are mounted
on the relay itself.
2. The above operation times are median. See Fig. 3 for details.
14
III. Technical Information
1. Water Circuit and Refrigerant Circuit
F-500BAF, F-500BAF-C
SPOUT
CONTROL
WATER
VALVE
FLOAT
SWITCH
RESERVOIR
OVERFLOW
GEAR
MOTOR
WATER LEVEL
EVAPORATOR
WATER
INLET
DRIER
CONDENSER
CONDENSER
FAN MOTOR
PRESSURE
SWITCH
COMPRESSOR
WATER CIRCUIT
REFRIGERANT CIRCUIT
ACCESS
VALVE
DRAIN
OUTLET
DRAIN PAN
DRAIN PAN
FLUSH
WATER
VALVE
ACCESS
VALVE
EXPANSION
VALVE
15
2. Wiring Diagram
F-500BAF, F-500BAF-C
16
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
3. Sequence of Electrical Circuit
F-500BAF, F-500BAF-C
[a] When power switch is moved to "ON" position and flush switch to "ICE"
position, water starts to be supplied to reservoir.
17
[b] When reservoir has been filled up, gear motor starts immediately.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
18
[c] Compressor starts about 60 sec. after gear motor starts.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
19
[d] Compressor stops about 90 sec. after bin control operates. Gear motor stops about
60 sec. later, and water is drained from the water circuit. Water can be also drained by
moving flush switch to "FLUSH" position.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
20
[e] When 208 - 230V are supplied to the power supply due to miswiring, circuit protect
relay operates, and the icemaker does not run.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
/