Pitco Frialator ME2 User manual

Category
Deep fryers
Type
User manual

This manual is also suitable for

L22-233 Rev 1 (04/03)
Technical Service and Exploded Parts
For Electric Fryers
Covering Models
MEII, ME2 Full and Split
Pitco Frialator, Inc., P.O. Box 501, Jct I-89 & I-93 Concord, NH 03302-0501 • 509 Route 3A, Bow, NH 03304
(800) 258-3708 • (603) 225-6684 • FAX (603) 225-8497
www.pitco.com
FRANCAIS
US
CAN
GB
L22-233 Rev 1 (04/03)
WARNING! FIRE HAZARD
THE OIL LEVEL SHOULD NOT FALL BELOW THE MINIMUM INDICATED LEVEL AT ANY TIME.
THE USE OF OLD OIL CAN BE DAGEROUS AS IT WILL HAVE A REDUCED FLASH-POINT
AND BE MORE PRONE TO SURGE BOILING.
WARNING
INSTALLATION AND ALL CONNECTIONS MUST BE MADE ACCORDING TO NATIONAL AND
LOCAL REGULATIONS AND CODES IN FORCE.
WARNING
A COUNTRY APPROVED ALL POLE CIRCUIT BREAKER WITH A MINIMUM OPEN CONTACT
GAP OF 3mm MUST BE USED FOR PROPER INSTALLATION.
WARNING
THE FRYER IS NOT JET STREAM APPROVED. DO NOT CLEAN THE APPLIANCE WITH A
WATER JET.
NOTICE
INSTALLATION SHOULD ONLY BE DONE BY A COMPETENT SERVICE TECHNICIAN. THE
MODEL & SERIAL NUMBER, AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA
PLATE, LOCATED ON THE INSIDE PANEL OF THE DOOR.
NOTICE
THIS APPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY, AND AS SUCH, SHOULD
BE OPERATED BY FULLY TRAINED PERSONNEL.
NOTICE
IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BY A QUALIFIED TECHNICIAN
ON A YEARLY BASIS.
WARNING
THE POWER SUPPLY MUST BE DISCONNECTED SERVICING OR CLEANING THE UNIT.
WARNING
SHORTENING, WHEN IT IS AT OPERATING TEMPERATURES, IS VERY HOT AND
DANGEROUS! USE EXTREME CAUTION WHEN HANDLING! USE PROPER PROTECTIVE
GEAR SUCH AS INSULATED GLOVES, APRONS, FACE SHIELD, AND SLEEVES WHEN
HANDLING HOT SHORTENING. DO NOT ATTEMP TO MOVE MACHINE THAT HAS HOT OIL IN
IT. ALLOW TO COOLTO ROOM TEMPERATURE OR DRAIN THE OIL INTO A SUITABLE
CONTAINER BEFORE MOVING THE FRYER.
L22-233 Rev 1 (04/03)
Table of Contents
How Does It Work? ........................................................... 4
Component Troubleshooting.............................................. 4
Temperature Probe Resistance Chart ................................. 4
Basic Trouble Shooting ...................................................... 6
Relay Board Component Explanation ................................ 8
Ladder Diagram .................................................................. 11
Schematics ......................................................................... 12-21
Basic Parts List................................................................... 23
Exploded Drawings ............................................................ 24-33
Element and Tank Components ......................................... 24
Pump Box and Drain Manifold........................................... 26
Main Entrance Box ............................................................. 28
Pump Assembly and Filter Pan ..........................................30
Wire Harness’..................................................................... 32
US
CAN
GB
4L22-233 Rev 1 (04/03)
Chapter 1: HOW DOES IT WORK?
The McDonalds Electric II fryer components function
in specific order of operation. Knowing and understand-
ing the sequence of fryer and components operation will
enable you to diagnose equipment failure more
accurately.
Heating System
Power to the machine is turned ON:
• If Fuse F1 on the Relay board is good, the A.C.
light will illuminate. The computer is supplied with
24VAC and, if the drain valve handle is closed, the
proximity switch will supply 24 VAC to the DVI
(drain valve interlock) Input at the computer.
• The computer is turned ON:
• The side on relay will be energized, closing the
circuit and the S.O. light on the Relay Board will
illuminate. If the hi limit is NOT tripped the safety
(side on) contactor will energize.
• Computer calls for heat:
• The 24 VDC "heat demand" relay will energize
supplying the heat demand contactor with 24 VAC
and the H.D. light on the Relay Board will
illuminate. This will also supply the computer with a
heat feedback signal.
Hi Limit System:
• If the hi limit trips, it causes the side on and heat
demand contactors to lose 24VAC supply and the
heat feed back loses 24VAC. The computer will
display IGNITION FAILURE or HEAT FAIL.
After the hi limit resets (unit cools to 375°F + 20°F)
the computer will have to be turned off and back
on for the unit to heat.
Hood Relay System: U.S./Canada units only
• There is one Hood Relay (K6) per "battery" of
fryers (located on rear bottom brace of left hand
fryer), it is wired in parallel to every computer (both
sides of a twin). When any side of any computer is
turned on this relay energizes (turning on the hood)
and will stay energized until all of the computers are
turned off.
Filter System:
• Opening the RED return valve handle will close the
proximity switch causing the "pump run" relay to
be energized. The pump motor will begin to run.
Closing the return valve handle will de-energize the
relay and the pump motor will stop running.
• The pump system is equipped with a circuit breaker
which will de-energize the system and the heat tape
in the event of overcurrent. The circuit breaker
switch must be in the ON position for the pump and
heat tape to operate.
• The return piping system may be provided with op-
tional heat tape to prevent solidification of solid
shortening. The heat tape is low wattage and is on
constantly to maintain liquid shortening in the line.
Chapter 2: COMPONENT
TROUBLESHOOTING:
Probe:
The resistance of the probe will change as the tempera-
ture changes. The resistance will decrease as the tem-
perature rises. The lower the temperature the greater
the resistance change will be per degree of temperature
change, as the temperature approaches the working
range of the probe, the resistance change will become
more linear.
If the probe is suspect, check its resistance and the oil/
air temperature at which it was taken. Compare these
5
L22-233 Rev 1 (04/03)
US
CAN
GB
values on the chart below.
If the probe returns an open circuit or 0 Ohms reading it
should be replaced. If the resistance varies more than
30 Ohms when being checked between 325-375°F the
probe will give a false temperature reading on the com-
puter and should be calibrated (up to 10°F) or replaced.
However, it will continue to operate at a slightly higher
or lower temperature.
Allow the oil to cool and check the probe resistance at a
lower temperature. As can be seen from the chart a
greater variation can be tolerated at a lower tempera-
ture.
Heat Demand Contactor:
The heat demand contactor has a 24VAC coil and will
energize when the correct voltage is supplied to the
coil. When energized, the contacts will close, allowing
current to flow through the elements. The coil
resistance is 192 ohms out of circuit.
Hi Limits:
The hi - limit switch is a normally closed switch until
the temperature at the hi-limit bulb reaches 425°F ±
20°F.
In order to test this switch it will be necessary to utilize
the temperature control hi-limit feature. Refer to PM
Card FR015 for instructions on how to perform this
test.
WARNING
During this test monitor the fryer closely. This test
will cause the oil to heat past the normal operating
temperature and can cause damage to the machine
and its operator if care is not taken.
If the switch does not trip between the prescribed
limits it is defective and should be replaced. Once
tripped, the switch cannot be reset until the oil has
cooled to approximately 375°F + 20°F. If the switch
does not reset after oil has cooled it is defective.
Once the oil has cooled the hi-limit reset button must
be pressed to reset the hi-limit relay on CE and export
units only.
Drain Valve & Return Valve Switches:
These switches are a magnetically operated proximity
switches. When the Drain Valve handle is moved to
the open position, the Actuator will move away from
the switch causing the switch to open. When the Drain
Valve is closed the switch will close.
Opening the RED return valve handle will close the
proximity switch causing the "pump on" relay to be
energized. The pump will begin to pump. Closing
the return valve handle will de-energize the relay and
the pump will stop pumping. These switches can also
be checked with an Ohm meter. The normal gap
between the Actuator and the Sensor switch on the
valve handle is
1
/
8
" -
1
/
4
" (3 - 6mm).
Transformer:
Transformers are multiple input voltage 24 volt output
voltage and can be checked by reading the input and
output voltages. A quick check for 24VAC can be done
at the relay board behind the computer. The AC led will
be lit if the F1 fuse is good and the board is receiving
24VAC
Elements:
Each Element has three coils inside it, check all element
coils out of circuit with an Ohm Meter, the resistance
should correspond to the chart below, if the resistance
varies more than 5 Ohm the element will need to be
changed. Also check for continuity to ground on each
end of the suspect element, there should be no continuity
to ground.
208 volt elements 18.5 Ohms
220 volt elements 20.7 Ohms
240 volt elements 24.6 Ohms
Safety (Side On) Contactor:
Check the coil with an Ohm Meter, the resistance should
be approximately 3 - 6 Ohms out of circuit. If it does
not have this resistance it should be changed.
6L22-233 Rev 1 (04/03)
Fryer Trouble Shooting
PROBLEM POSSIBLE CAUSE ACTION
Computer will N O T turn O N
Display does NOT light
A. No power to the machine
B. F1 Fuse blown
C. T1A Transformer
A. Check building circuit breaker, verify
power cord is plugged in
B. Check F1A Fuse. Replace if defective
C. Check voltage in and out of T1A
Computer shows "IGNITION
FAILURE" or "HEAT FAIL" and
machine does NOT heat.
A. Hi limit tripped
B. Heat demand relay
C. Relay board
A. Once the oil temp has gone below
375°F +
20°, the Hi- limit should reset
automatically, if not, replace Hi- limit
B. Check & replace if defective
C. Check & replace if defective
Machine is heating slowly A. Side On contactor
B. Heat Demand contactor
C. Element
D. Loss of power on one leg of 3
phase input power
A. Check & replace if defective
B. Check & replace if defective
C. Check & replace if defective
D. Check input power. Repair or call a
qualified electrician
Oil is hotter or colder than computer
/controller displays
A. Temperature calibration
B. Probe
C. Probe wiring terminals
A. Adjust temperature offset up to +
10°F
B. Check & replace if defective
C. Clean or repair terminals
Computer displays "DRAINING" or
"TURN OFF"
A. Blue drain valve not fully closed
B. Sensor switch
C. Incorrect switch gap/alignment
A. Check position of handle
B. Switch may be loose or have loose
wires, replace if defective
C. Check gap/alignment, replace if defective
Computer heat demand lights are lit,
machine does not heat. HD & SO
lights on relay board are lit.
A. Side on contactor
B. Heat demand contactor
C. Unit not getting 3 phase power
A. Check & replace if defective
B. Check & replace if defective
C. Check circuit breaker, is 3 phase power
cord plugged in all the way
Computer displays "PROBE
FAILURE"
A. Shorted probe
B. Open probe
C. Probe wiring terminals
A. Check probe & replace if defective
B. Check probe & replace if defective
C. Clean or repair terminals
7
L22-233 Rev 1 (04/03)
US
CAN
GB
Filter Trouble Shooting
PROBLEM POSSIBLE CAUSE ACTION
Red return handle is pulled out, but no
pump sound can be heard
A. Red return handle not completly
open
B. Filter circuit breaker may be tripped
or in the off position
C. Filter motor thermal overload may
be tripped
D. Sensor switch may be loose or
defective
E. Power cord unplugged or loose
A. Pull on red return handle to make sure
valve is completly open
B. Reset the circuit breaker or press it to
the on position
C. Push the red reset button on the end of
the motor
D. Check that the switch is tight and that it
has the correct gap. Replace if defective
E. Check the power cord at the fryer
entrance box and at the pump box and
make sure that the power cords are plugged
in and /or pushed in all the way
Drain valve is closed, computer has
been reset, but computer still displays
"DRAIN IN G"
A. Blue drain valve not fully closed
B. Sensor switch
C. Incorrect switch gap/alignment
A. Check position of handle
B. Switch may be loose or have loose
wires, replace if defective
C. Check gap/alignment, replace if defective
Oil is returning to the vat slowly or not
at all
A. Dirty filter paper
B. Strainer cap dirty
C. Filter pan not pushed in completely
D. O-rings not sealing on pick up tube
A. Change filter paper
B. Remove strainer cap and clean it
C . Push filter pan in
D. Check & replace if defective
Air bubbles are in the o il being returned
to the vat
A. Strainer cap not tight
B. Stainer cap not in pick up tube
C. Filter pan not pushed in completely
D. O-rings not sealing on pick up tube
A. Tighten strainer cap
B. Install strainer cap
C . Push filter pan in
D. Check & replace if defective
Drain valve is open, the oil is draining
slowly or not at all
A. Drain valve is not fully open
B. Drain line is plugged with debris
A. Apply a little more pressure to the drain
valve handle to check that the drain valve is
fully open
B. Use the clean out rod to clear the drain
valve opening. If this does not clear the
blockage, close the drain valve, and call for
service
8L22-233 Rev 1 (04/03)
10
1
6
1
12
1
PITCO# 60127301A
DATE: MMDDYY
A.C.
H.D.
S.O.
F1 FUSE
1
5
7
1
K1
HEAT
DEM ON
SIDE
K3
J32
J34
J35
J31
J33
Fuse:
F1 -
Trouble Shooting Lights:
A
.C. -
S.O. -
H.D. -
Relays:
K1 -
K3 -
Connectors:
J31 -
J32 -
J33 -
J34 -
J35 -
If fuse is blown, A.C. will not be lit.
When lit, F1 Fuse and T1 Transformer are good.
When lit, A1 Computer is on and K10 Contactor should be energized.
When lit, A1 Computer is on and calling for heat, K11 Contactor should be energized
Heat Demand Relay, will be energized when A1 Computer calls for heat and when H.D. is lit.
Side On Relay, will be energized when A1 Computer is on and A.C. is lit.
Connects to A1 Computer
To Side On and Heat Demand Contactors and Heat Feed Back.
To 24VAC jumper harness.
To Drain Switch and optional Basketlifts
Input voltage from transformer
Relay Board Component Explanation
9
L22-233 Rev 1 (04/03)
US
CAN
GB
OR FLOAT
TO DRAIN
SWITCH
2
1
5
6
3
4
LIFT OPTION
TO BASKET
J34
1
AC POWER
6
4
5
3
HEAT DEM
K1
2
1
K3
SIDE ON
4
24VAC
F1
3
21
24VCOM
5
TRANSFORMER
24VA
C
FR
O
M A
C
LA
S
S
2
2
3
7
5
4
8
9
6
12
10
11
HEAT FEED BACK
TO RESET SWITCH IF REQUIRED
24VAC RETURN
TO HIGH LIMIT
BACK-UP
HEAT DEMAND ENABLE
HEAT DEMAND
TO
DRAIN OR
FLOAT SWITCH
24VACH
1
3
NONE
BASKET LIFT R
BASKET LIFT L
SIDE ON (DC)
HEAT DEMAND
24VDC RETURN
24VAC RETURN
HEAT FEEDBACK
6
2
4
5
7
8
10
9
TEMPERATURE
TO
PRIMARY
COOKING
CONTROLLER
FUSE
SIDE ON
K3
K1
HEAT
DEMAND
HEAT FEED BACK
24VACH POWER
24VACN RETURN
DRAIN OR FLOAT SWITCH
24VAC POWER SWITCHED
HEAT DEMAND
NONE
NONE
SIDE ON
DC RETURN
NONE
NONE
7
DC COMMON
BASKET LIFT LEFT
BASKET LIFT RIGHT
(DC)(DC)
CONTROL (OPT
)
OR NO OPTION
JUMPER BLOCK
J31
J34
60127301
J35
J32
J34
J33
Relay Board
10
L22-233 Rev 1 (04/03)
Schematics
1
2
3
4
6
7
5
1
2
3
4
6
7
5
ABC
DE
FGH
I
J
11
L22-233 Rev 1 (04/03)
DVI
INPUT
24 VDC
COMMON
PROBE
INPUT
ON/OFF
(SIDE ON)
OUTPUT
HEAT DEMAND
OUTPUT
HEAT
FEEDBACK
INPUT
24 VAC
INPUT
24 VAC
COMMON
24 VAC +
RELAY BOARD
SIDE ON
HEAT
DEMAND
HEAT
DEMAND
CONTACTOR
SIDE ON
CONTACTOR
F1 FUSE
TRANSFORMER
AC
SO HD
24 VAC
COMMON
HI LIMIT
SWITCH
(DOMESTIC
ONLY)
DRAIN
SWITCH
NO
NC
NO
NC
HI LIMIT
RESET
24 VAC
COMMON
24 VAC +
TO TRANSFORMER
TO HI LIMIT
SWITCH
CONNECTOR
CE/EXPORT ONLY
12
L22-233 Rev 1 (04/03)
18AWG UNLESS NOTED.
LEFT SIDE OF SPLIT VAT, OR SINGLE VAT CONTROL CIRCUIT SHOWN.
OPTIONAL BACKUP T-STAT (A3) NOT AVAILABLE. JUMPER WIRE
P33-10 TO P33-2 IS REQUIRED (B6747001).
CONTROL WIRING IS UL TYPE AWM, 300V, COLOR SHOWN. ALL WIRE IS
DRAIN VALVE SWITCH IS CLOSED WHEN VALVE IS CLOSED.
LINE CORD CABLES ARE TYPE SJTO. AMERICAN WIRE GAUGE (AWG) AS SHOWN.
RIGHT SIDE OF SPLIT VAT IS IDENTICAL UP TO P1. SEE TABLE 2.
FILTER PUMP (M1), AND PUMP BOX (A5), ARE POWERED BY SEPARATE SINGLE
PHASE POWER SOURCE (J102). VOLTAGE DEPENDS ON CORD BOX OPTION (A11)
INSTALLED. ONE CORD BOX PER FRYER BATTERY. SEE SHEET 3.
CONTROL TRANSFORMER IS POWERED BY SEPARATE SINGLE
INSTALLED. ONE CORD BOX PER FRYER BATTERY. SEE SHEET 3.
PHASE POWER SOURCE (J101). VOLTAGE DEPENDS ON CORD BOX OPTION (A11)
7.
4.
5.
6.
2.
3.
1.
11
12
3
8
7
10
9
5
4
6
2
1
NONE
SIDE ON
24VDC OUT
SIDE ON
NONE
PROBE +
PROBE -
DC RETURN
HEAT DEMAND
DRAIN VALVE(DVI)
HEAT FEED BACK
NONE
NONE
24VDC COM
24VDC OUT
24VAC INPUT
TEMPERATURE
24VAC INPUT
24VACH
24VAC COM
AC POWER
(FRAME GND)
PROBE +
DC RETURN
HEAT DEMAND
NONE
NONE
DRAIN VALVE(DVI)
HEAT FEED BACK
PROBE -
NONE
NONE
PIN#
I/O TYPE LEFT SIDE RIGHT SIDE
TABLE 2: (A1) McDONALDS CONTROLLER CONNECTIONS
NOTES:
Schematic 700338 Sheet
1
SWITCH, HIGH LIMIT SELF RESET
XFMR, 120-208-240V/24VAC 80VA CLASS 2
PROBE, NTC THERMISTOR GAS
COMPUTER COOKING CNTRL SINGLE/DUAL McDS
SWITCH ACTUATOR MAGNETIC
SWITCH PROXIMITY MAGNETIC
FUSE 1.5A 250V TIME DELAY CERAMICF1
RT1
T1A
LS1
HL1
A1
PP10263
60132702
PP10429
60141201
B5305001
B6700605-C
60137701
CORD BOX DOMESTIC WITH NEMA L21-20P PLUG MDG B1824301
A11
CORD BOX EXPORT CE W/IEC1302 PLUG MDG B1824302
CORD BOX EXPORT NO PLUG B1824303
A4 CNTRL, RELAY BOARD 24V CLASS 2 60127301
K4 RELAY, 3PDT, 10A, 24VAC W/MNTG TABS 60126001
CORD BOX DOMESTIC NO HOOD CNTRL 115V MDG B1824304
A5
CNTRL, PUMP BOX ASSY 115V/50-60HZ B6673001
CNTRL, PUMP BOX ASSY 208V/50-60HZ B6673005
CNTRL, PUMP BOX ASSY 230V/50-60HZ
B6673002
CNTRL, PUMP BOX ASSY 240V/50HZ
K6
RELAY SPST-NO 30A/250VAC, 24VDC COIL 60137301
K10 CONTACTOR, 3P, 40A, 24VAC DEF PURPOSE PP10560
K11
60139201CONTACTOR, 3P, 50A, 24VAC IEC
REF
DESCRIPTION
PART NO.
FRYER REPLACEMENT PARTS
LOCATION
SHEET 2, J6
SHEET 2, F4
SHEET 4, F4
SHEET 6, F4
SHEET 6, F4
SHEET 6, F4
SHEET 8, B4
SHEET 8, I4
SHEET 8, I4
SHEET 8, E5
SHEET 2, H2
SHEET 2, G3
SHEET 2, DOM C5, CE C2
SHEET 2, G6
SHEET 2, I4
SHEET 2, I4
SHEET 2, B3
SHEET 8, B3
SHEET 2, A5
SHEET 2, A4
1
2
3
4
6
7
5
1
2
3
4
6
7
5
ABC
DE
FGH
I
J
13
L22-233 Rev 1 (04/03)
NON CE
BLU
K4A
J/P47
HIGH LIMIT OK
K4C
FROM OTHER
21
P28
BOX J28
TO PUMP
HIGH LIMIT OK
8
K4B
YEL
1
5
RED
9
GRY
12
P47
CIRCUITS OR
HIGH LIMIT
JUMPER
2
6
GRY
HIGH LIMIT
MANUAL RESET (OPT)
CE EXPORT ONLY
HIGH LIMIT OK
HL1
LIMIT
HIGH
PB1 RESET
OK
HIGH LIMIT
WHT
1
YEL
RED
SIDE ON
4
*
HFB
24VACH
24VAC
COM
2
1
*
*
6
VIOL
RED
WHT
BLU/W
ORG
7
RED/W
CONTROL BOX
21
VIOL/W
Sheet 8
B1824301 ONLY
RED
BRN/W
WHT
ORG
J12
3
J/P34
3
W/BRN
AC
HFB
COM
5
6
TO HOOD
4
K3
K1
3
2
AB
HEAT FEED BACK
A2
BRN/W
K10
K11
A1
AC COM
HEAT DEM
3
J/P33
J/P32
24VAC
AC COM
3
2
B6747001
7
5
4
1
10
6
NOTE 2
GRN
FRAME
3
J/P5
12
12
3
4
5
YEL
RED
BRN/W
WHT
ORG
HIGH
LIMIT
HL1
7
J50
4
ORG
ORG
1
1
P5
2
3
2
3
10 11
K4
J/P48
21
12
J/P48
P49
12
CONNECT TO P5
OF S PLIT VAT
SAME AS BELOW
HIGH LIMIT CKT
TO RIGHT SIDE
(CE ONLY)
BLU
WHT
PART OF
ENTRANCE
BOX
T1A
TEMPERATURE CONTROL (LEFT SIDE CONNECTIONS)
A1
A4
RELAY BOARD
PART OF
ENTRANCE BOX
CONTROL
ENCLOSURE
LEFT CONNECTION ONLY
PROBE
2
2
WIRE HARNESS B6750801 LEFT
B6750701 RIGHT
J/P41
J/P31
10
YEL
9
PROBE+
PROBE-
3
4
SIDE ON
10
12
11
BLK
1
D5
NONE
VIOL/W
NONE
HEAT DEM
DC COM
8
7
BLK
J/P7
1
9
8
RT1
TEMP
657
6
5
K1
D4
AC
COM
HFB
4
3
2
K3
24VAC
DRAIN VALVE
NOT USED
G
FRYER
TO NEXT
N
J106
J107
N
LL
G
J/P34
J/P4
SWITCH
INPUT
J/P1
5
LS1
BRN
1
2
BRN
BLU
DRAIN
P101
CORD BOX
FROM A11
SHEET 3
1
1
2
(60127301)
24VAC
FUSE
1.5 A TD
F1
J/P35
24VAC COM
AC POWER
12
5
4
80VA
EQUIPMENT OR JUMPER
FROM FIRE SUPRESSION
4
GRN
WHT
2
BLK
3
1
BLU
FRAME
5
120V
BLK
2
1
240
3
208
BS3
10
WHT
1
6
24 VAC
VIOL
2
BLU
TO RIGHT SIDE
CONTROL CKT
SAME AS BELOW
OF SPLIT VAT
J/P2
ORG
S
chematic 7
00338
S
heet 2
S.O.
H.D.
A.C.
14
L22-233 Rev 1 (04/03)
Schematic 700338 Sheet 3
120V-50/60Hz
120V-50/60Hz RELAY, 24VAC, 30A SPST
FUSE 0.2A 250V TIME DELAY CERAMIC
RELAY, 24VAC, 30A DPST
230V-50/60Hz
F2
ALL
K5
240V-50Hz
60132701
60104701
MOTOR AND PUMP 1/3HP 5GPM
XFMR, 240/24 VAC 5VA
XFMR, 120/24VAC 5VA
MOTOR AND PUMP 1/3HP 5GPM
CKT BRKR,10 AMP SINGLE POLE
CKT BRKR, 5 AMP TWO POLE
230V-50/60Hz
120V-50/60Hz
T3
240V-50Hz
240V/50Hz
120V-50/60Hz
230V-50/60Hz
230V-50/60Hz
240V/50Hz
CB1
M1
60078502
PP11058
60130302
60130301
60130807
60077901
60130806
FH2 FUSE HOLDER, IN LINE, .25 X 1.25 PP10765
208V-50/60Hz
60130810MOTOR AND PUMP 1/3HP 5GPM
ITEM VOLTAGE DESCRIPTION PART NO.
FILTER PUMP REPLACEMENT PARTS
120-50/60Hz
HEATER TAPE 1/2X 72", 50W
HEATER TAPE 1/2X 33", 25W
HEATER TAPE 1/2X 33", 25W
HEATER TAPE 1/2X 72", 50W
240/50Hz
120-50/60Hz
240/50Hz
230-50/60Hz
230-50/60Hz
HTR2,3
HTR1
60133501
60133502
60133503
60133504
ITEM VOLTAGE
DESCRIPTION
PART NO.
SHORTENING HEATER OPTIONS REPLACEMENT PARTS
LOCATION
SHEET 4, B6
SHEET 4, E7
SHEET 6, E7
SHEET 4, G4
SHEET 6. F4
MOTOR AND PUMP 1/3HP 5GPM
60130806
SHEET 6, B6
SHEET 4, H3
SHEET 6, G3
SHEET 4, E3
SHEET 6, E3
SHEET 6, H3
SHEET 6, H3
LOCATION
SHEET 4, C4
SHEET 6, B4
SHEET 4, E1, B1
SHEET 4, E1, B1
1
2
3
4
6
7
5
1
2
3
4
6
7
5
ABC
DE
FGH
I
J
15
L22-233 Rev 1 (04/03)
*ADD .3 AMPS PER HEAT TAPE
115VAC 50-60 Hz/7.3 FLA*
IS SUPPLIED.
IF SHORTENING OPTION
16/3 AWG SJTO CORD
GRN-16
G
T
5
115V 50/60HZ
P1
WHT-16
BLK-16
P
2
T
3
T4T8 T2
PUMP MOTOR
FRAME
WHT
WHT
115 V
RUN
SHORTENING HEATER OPTIONS
WHT-18
WHT-16
BLK-16
BLK-16
BLK
ON/OFF
(RESET) BLK-18
N01
C1
5VA
1
J/P30
BLU
212
W/BRN
YEL
J/P29
VIOL
AS SHOWN.
VALVE OPEN
OR FLUSH HOSE.
RETURN VALVE
TYPICAL
VALVE
TO NEXT
21
VIOL
WHT
VIOL
WHT
115V/ 25W
HEATER OPTION
FLUSH HOSE 2
P19
2
1
3
1
2
3
P18
115V/ 25W
HEATER OPTION
FLUSH HOSE 1
3
2
1
J52
J51
3
2
1
2
3
1
115V/ 50W
PUMP RETURN
LINE
P51
1
B6748101
B6748102
B6748103
B6748104
P52 P52
321 321
B6748001
23
J18
213
J19 J18
123
J/P22
12
G
GL
N
LN
16 AWG
SJTO
N
J71
GND
L
SJTO
16 AWG
J72
L N
GND
J20
24V
P102
CORD BOX
FROM A11
SHEET 8
CONSTRUCTION),
JUMPER IF
ALT. HIGH LIMIT
(BULK OIL OR
PUMP DISABLE
12
NOT USED
BLU
P28 J28
A5 PUMP BOX
M1
LS4
CB1
T3
K5
115V
/
60HZ
(
D
O
ME
S
TI
C)
HTR3HTR2
HTR1
208V 50-60HZ
PUMP MOTOR
WHT-16
GRN-16
BLK-16
T1
T
5
G
T3
T8 T4
T2
M1
Schematic 700
33
8 Sheet 4
16
L22-233 Rev 1 (04/03)
Schematic 700338 Sheet5
120V-50/60Hz
120V-50/60Hz RELAY, 24VAC, 30A SPST
FUSE 0.2A 250V TIME DELAY CERAMIC
RELAY, 24VAC, 30A DPST
230V-50/60Hz
F2
ALL
K5
240V-50Hz
60132701
60104701
MOTOR AND PUMP 1/3HP 5GPM
XFMR, 240/24 VAC 5VA
XFMR, 120/24VAC 5VA
MOTOR AND PUMP 1/3HP 5GPM
CKT BRKR,10 AMP SINGLE POLE
CKT BRKR, 5 AMP TWO POLE
230V-50/60Hz
120V-50/60Hz
T3
240V-50Hz
240V/50Hz
120V-50/60Hz
230V-50/60Hz
230V-50/60Hz
240V/50Hz
CB1
M1
60078502
PP11058
60130302
60130301
60130807
60077901
60130806
FH2 FUSE HOLDER, IN LINE, .25 X 1.25 PP10765
208V-50/60Hz
60130810MOTOR AND PUMP 1/3HP 5GPM
ITEM VOLTAGE DESCRIPTION PART NO.
FILTER PUMP REPLACEMENT PARTS
120-50/60Hz
HEATER TAPE 1/2X 72", 50W
HEATER TAPE 1/2X 33", 25W
HEATER TAPE 1/2X 33", 25W
HEATER TAPE 1/2X 72", 50W
240/50Hz
120-50/60Hz
240/50Hz
230-50/60Hz
230-50/60Hz
HTR2,3
HTR1
60133501
60133502
60133503
60133504
ITEM VOLTAGE
DESCRIPTION
PART NO.
SHORTENING HEATER OPTIONS REPLACEMENT PARTS
LOCATION
SHEET 4, B6
SHEET 4, E7
SHEET 6, E7
SHEET 4, G4
SHEET 6. F4
MOTOR AND PUMP 1/3HP 5GPM
60130806
SHEET 6, B6
SHEET 4, H3
SHEET 6, G3
SHEET 4, E3
SHEET 6, E3
SHEET 6, H3
SHEET 6, H3
LOCATION
SHEET 4, C4
SHEET 6, B4
SHEET 4, E1, B1
SHEET 4, E1, B1
1
2
3
4
6
7
5
1
2
3
4
6
7
5
ABC
DE
FGH
I
J
17
L22-233 Rev 1 (04/03)
WHT-16
WHT-16
BLK-16
BLK-16
P1
GRN-16
IF SHORTENING OPTION IS SUPPLIED.
*ADD .15 AMPS PER HEAT TAPE
230 VAC/ 50-60Hz / 3.6-4.2 FLA *
240 VAC/ 50HZ / 4.3 FLA *
16/3 AWG SJTO CORD
WHT-16
BLK-16
240V
FRAME
(RESET)
ON/OFF
BLK
ORG
0.2A TD
BLU
F2
BLU
5VA
21
J/P30
J/P29
12
VIOLWHT
21
J/P22
AS SHOWN.
VALVE OPEN
OR FLUSH HOSE.
TYPICAL
RETURN VALVE
VALVE
TO NEXT
VIOL
WHT
2
1
J20
VIOL
WHT
G
T
5
GRN-16
G
T
5
T
2
T
3
T4T8 P2
P1
WHT-16
BLK-16
T4T8
PUMP MOTOR
230V 50/60HZ
PUMP MOTOR
240V 50HZ
RUN
N02
C2
N01
C1
W/BRN
YEL
240V/ 25W
FLUSH HOSE 2
HEATER OPTION
240V/ 25W
FLUSH HOSE 1
HEATER OPTION
P18
3
2
1
3
1
2
P19
J18
213 213 1
J18 J19
23
P51
1
3
2
LINE
PUMP RETURN
240V/ 50W
B6748001
12
P52
B6748103
B6748102
B6748101
3 1
P52
SHORTENING HEATER OPTIONS
B6748104
23
1
2
3
J52
1
2
3
J51
WHT-18
BLK-18
L
L GN
NG
J71
L
GND
SJTO
16 AWG
N
N
L
GND
16 AWG
SJTO
J72
T1
24V
P102
SHEET 8
FROM A11
CORD BOX
208 VAC/ 50-60Hz / 3.1-3.8 FLA *
1 2
PUMP DISABLE
(BULK OIL OR
CE HIGH LIMIT
CONSTRUCTION),
JUMPER IF
NOT USED
P28 J28
A5
PUMP BOX
208, 220-230V/50-60HZ OR 240V/50HZ (EXPORT AND CE)
CB1
T3
LS4
M1 M1
K5
HTR3HTR2
HTR1
Schematic 700338 Sheet
6
18
L22-233 Rev 1 (04/03)
LBL, CORD BOX DOM W/HOOD CNTRL 208V MG2, MEII USE 700334-4
USE 700334-5
USE 700334-6
LBL, CORD BOX EXPORT 230V MG2, MEII
LBL, CORD BOX NO HOOD CNTRL 115V MG2, MEII
USE 700334-2
USE 700334-3
10952
SEE TITLE BLOCK
10952
10952
10952
10952
LBL, WIRING FLTR PUMP 208/230V/240V MG2, MEII
LBL, WIRING FLTR PUMP 115V/50-60HZ MG2, MEII
LBL, 3PH WYE SINGLE TYPICAL MEII
SCHEM. ELEC McDONALDS SV OR FV ALL MEII
LBL, 3PH DELTA DUAL TYPICAL MEII
LBL, 3PH DELTA SINGLE TYPICAL MEII
LBL, WIRING CNTRL TYPICAL 24V MEII
LBL, 3PH WYE DUAL TYPICAL MEII
700338-4
700338-3
700338-5
700338
700338-2
700338-1
A
A
A
A
A
P/N ECN
DESCRIPTIONPART NO.
P/N REV
TABLE 1
Schematic 700338 Sheet
7
SWITCH, HIGH LIMIT SELF RESET
XFMR, 120-208-240V/24VAC 80VA CLASS 2
PROBE, NTC THERMISTOR GAS
COMPUTER COOKING CNTRL SINGLE/DUAL McDS
SWITCH ACTUATOR MAGNETIC
SWITCH PROXIMITY MAGNETIC
FUSE 1.5A 250V TIME DELAY CERAMICF1
RT1
T1A
LS1
HL1
A1
PP10263
60132702
PP10429
60141201
B5305001
B6700605-C
60137701
CORD BOX DOMESTIC WITH NEMA L21-20P PLUG MDG B1824301
A11
CORD BOX EXPORT CE W/IEC1302 PLUG MDG B1824302
CORD BOX EXPORT NO PLUG B1824303
A4 CNTRL, RELAY BOARD 24V CLASS 2 60127301
K4
RELAY, 3PDT, 10A, 24VAC W/MNTG TABS 60126001
CORD BOX DOMESTIC NO HOOD CNTRL 115V MDG B1824304
A5
CNTRL, PUMP BOX ASSY 115V/50-60HZ B6673001
CNTRL, PUMP BOX ASSY 208V/50-60HZ B6673005
CNTRL, PUMP BOX ASSY 230V/50-60HZ
B6673002
CNTRL, PUMP BOX ASSY 240V/50HZ
K6
RELAY SPST-NO 30A/250VAC, 24VDC COIL 60137301
K10 CONTACTOR, 3P, 40A, 24VAC DEF PURPOSE PP10560
K11 60139201CONTACTOR, 3P, 50A, 24VAC IEC
REF
DESCRIPTION
PART NO.
FRYER REPLACEMENT PARTS
LOCATION
SHEET 2, J6
SHEET 2, F4
SHEET 4, F4
SHEET 6, F4
SHEET 6, F4
SHEET 6, F4
SHEET 8, B4
SHEET 8, I4
SHEET 8, I4
SHEET 8, E5
SHEET 2, H2
SHEET 2, G3
SHEET 2, DOM C5, CE C2
SHEET 2, G6
SHEET 2, I4
SHEET 2, I4
SHEET 2, B3
SHEET 8, B3
SHEET 2, A5
SHEET 2, A4
1
2
3
4
6
7
5
1
2
3
4
6
7
5
ABC
DE
FGH
I
J
19
L22-233 Rev 1 (04/03)
230VAC/1PH/10A MIN SERVICE
J103
P104
J101
CORDSET
#60137401
L
G/Y-14
BRN-14
BLU-14
N
G
G
WHT-14
G/Y-14
L
N
BLK-14
12 3
NOT USED
J102
CORDSET
#60137402
PLUG
SUPPLIED
BY OTHERS
EXPORT
CE
EXPORT
NON CE
B1824302 OR B1824303
L- BRN
N- BLUE
G- G/Y
TO PUMP BOX
SEE SHEET 4
208, 220-240V
MG2 AND MEII
ENTRANCE BOX
TO FIRST FRYER
CORD BOX EXPORT
CORD BOX EXPORT
A11
NO HOOD CONTROL
INSTALLED WITH
HOOD OPTION ONLY
J103
J103
13
W/VIOL
RED
W/VIOL
RED
N01
C1
YEL
HOOD
W/BRN
2
TO NEXT
FRYER
OR
J103
P12
TO NEXT
FRYER
231
RED
W/VIOL
RED
W/VIOL
321
P103
P12
P12L
CORD BOX
12 3
IN FAR
LEFT CABINET
P104
GW Z XY
GRN WHT ORG RED BLK
TO HOOD MOTOR
CONTROL CKT.
20A/208VAC MAX
GNEUT L
120VAC/15A
CORDSETP#6013
7201
CUSTOMER SUPPLIED EQUIPMENT
NEMA L21-20P120/208
VACP3PHASE
GND NEUT L1 L2 LOAD
J102
L
BLK-14
WHT-14
GRN-14
SEE SHEET 2
TO PUMP BOX
N
G
BLK-12
RED-12
ORG-12
WHT-12
GRN-12
L
J101
G
N
RELAY
B1824301
B6748901 SINGLE
115V
MG2 AND MEII
ENTRANCE BOX
TO FIRST FRYER
123
123 213
312
P103
123
DUAL SINGLE
A11
DOMESTIC ONLY
CORD BOX WITH HOOD CONTROL
J12LJ12R J12L
K6
CORD AND HOOD RELAY BOX
115 V
SEE SHEET 4
TO PUMP BOX
MG2 A ND MEII
ENTRANCE BOX
TO FIRST FRYER
DOMESTIC ONLY
CORD BOX NO HOOD CONTROL
A11
CORD BOX DOMESTIC
115VAC/1PH/50-60Hz/15A MIN SERVICE
PLUG
NEMA 5-15P
J102
GRN-14
BLU-14
BRN-14
L
N
G
G
WHT-14
GRN-14
L
N
BLK-14
J101
J103
NOT USED
12 3
B1824304
Schematic 700338 Sheet
20
L22-233 Rev 1 (04/03)
WIRE
OPTION
14.0 KWL2-33.7 A
10 AWG
10 AWG
14.0 KW
550006613
CONNECT
VOLTAGE/ AMPS
B6730806
P/N
FILTER PUMP
CONNECT-(TAP)
BLK-(2) WHT-(5)
TAP VOLTS
PP10429
NOTE 6
P/N
TRANSFORMER
OPTION
WIRE
TOTAL HEAT KW
1B-6D WIRE SIZE
14.0 KW
10 AWG
550006612
550006609
HTR1-HTR6 P/N
SINGLE VAT
8.5 KW 8.5 KW
14 AWG
14 AWG
8.5 KW
550006613
14 AWG
14 AWG
8.5 KW
550006613
SPLIT VAT
HEAT KW
8.5 KW
14 AWG
1B-6D WIRE SIZE
550006612
550006609
HTR1-HTR3 P/N
LEFT SIDE
HEAT KW
1B-6D WIRE SIZE
14 AWG
8.5 KW
550006612
550006609
RIGHT SIDE
HTR4-HTR6 P/N
LINE
3 PHASE ELECTRICAL SERVICE REQUIREMENTS
FOR MODEL MEII
115V 1PH 50/60Hz
J102 (A11)
3
3
3
480
240
208
TABLE 3A: LINE CONNECTION OPTIONS FOR U.S. AND CANADA
1
1
1
3 WIRE & GND
3 WIRE & GND
3 PHASE
DELTA
DELTA
WIRES & GND
LOAD TYPE
3 WIRE & GND
3 PHASE
3 PHASE
DELTA
VOLTAGE
CONNECTION
SEE NOTE 7
115V 5.6A 50/60Hz
L3-33.7 A
L3-16.8 A
L2-16.8 A
L1-16.8 A
TOTAL HEATER
L2-38.9 A
L1-38.9 A
L3-38.9 A
L1-33.7 A
LESS OPTIONS
LINE AMPS
10 AWG
L3-21.3 A
L3-19.5 A
L3-15.4 A
L2-15.4 A
L1-15.4 A
10 AWG
11.8 KW
14 AWG
50006613
L1-20.2 A
L1-19.5 A
L2-19.5 A
L2-20.2 A
L3-20.2 A
50006611
14.0KW
14.0 KW
10 AWG
50006612
L1-21.6 A
L2-21.6 A
L3-21.6 A
L1-21.3 A
L2-21.3 A
12.9 KW
10 AWG
50006609
14.0 KW
50006610
L2-36.7 A
L3-36.7 A
L3-37.4 A
L1-36.7 A
L2-37.4 A
L1-37.4 A
14.0 KW
10 AWG
12.9 KW
10 AWG
50006610
50006609
CONNECTION
LINE
RIGHT SIDE
HTR4-HTR6 P/N
1A-6D WIRE SIZE
FILTER PUMP
P/N
TAP VOLTS
TRANSFORMER
HTR1-HTR6 P/N
TOTAL HEAT KW
1A-6D WIRE SIZE
WIRE
OPTION
SINGLE VAT
HTR1-HTR3 P/N
HEAT KW
1A-6D WIRE SIZE
WIRE
OPTION
LEFT SIDE
SPLIT VAT
HEAT KW
14 AWG
5.9 KW
14 AWG
7.0 KW
7.0 KW
14 AWG
6.4 KW
14 AWG
6.5 KW
14 AWG
14 AWG
7.0 KW
6.4 KW
14 AWG
208V 4A 50Hz
60130810
NOTE 7
50006609
50006610
50006609
50006610
50006611
50006612
50006613
14 AWG
5.9 KW
6.4 KW
50006612
50006613
7.0 KW
14 AWG
14 AWG
50006610
50006611
7.0 KW
14 AWG
14 AWG
14 AWG
50006610
50006609
7.0 KW
6.5 KW
14 AWG
50006609
6.4 KW
208V 1PH 50/60Hz
BLK-(2) WHT-(5)
J102 (A11)
NOTE 6
PP10429
J102 (A11)
240V 1PH 50/60Hz
BLK-(1) WHT-(5)
PP10429
NOTE 6
1
2
2
2
2
1
1
TABLE 3B: LINE CONNECTION OPTIONS FOR INTERNATIONAL SERIVCES
4
3
4
4
4
3
3
440
400Y/230
415Y/240
380Y/220
346Y/200
200
220
4 WIRE & GND
3 WIRE & GND
WYE
3 PHASE
DELTA
4 WIRE & GND
3 PHASE
3 PHASE
WYE
WYE
60130807
NOTE 7
NOTE 7
60130806
240V 3.5A 50Hz
230V 3.8A 50/60Hz
230V 3.8A 50/60Hz
NOTE 7
60130806
DELTA
4 WIRE & GND
4 WIRE & GND
3 PHASE
3 PHASE
WYE
3 WIRE & GND
3 WIRE & GND
3 PHASE
3 PHASE
DELTA
NOTE 7
60130806
NOTE 7
60130810
230V 3.4A 50/60Hz
208V 4A 50Hz
VOLTAGE
WIRES & GND
LOAD TYPE
TOTAL HEATER
LESS OPTIONS
LINE AMPS
CONNECT-(TAP)
P/N
CONNECT
VOLTAGE/ AMPS
S
c
h
e
m
a
t
i
c
7
0
0
3
3
8
S
h
e
e
t
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Pitco Frialator ME2 User manual

Category
Deep fryers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI