Lucent Technologies CellPipe IAD 8T Hardware Installation Manual

Category
Serial switch boxes
Type
Hardware Installation Manual

This manual is also suitable for

CellPipe IAD 4A and
CellPipe
™ IAD 8T
Hardware Installation Guide
Part Number: 7820-0791-001
For software version 2.0
January 2001
Lucent Technologies
Copyright © 2001 Lucent Technologies Inc. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or
altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable
agreements, contracts, or licensing, without the express written consent of Lucent Technologies. For permission to reproduce or
distribute, please email your request to [email protected].
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but infor-
mation is subject to change.
Safety, Compliance, and Warranty Information
Before handling any Lucent Access Networks hardware product, read the Edge Access Safety and Compliance Guide included in
your product package. See that guide also to determine how products comply with the electromagnetic interference (EMI) and
network compatibility requirements of your country. See the warranty card included in your product package for the limited
warranty that Lucent Technologies provides for its products.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access
features.
Copyrights for Third-Party Software Included in Lucent Access Networks Software Products
C++ Standard Template Library software copyright© 1994 Hewlett-Packard Company and copyright© 1997 Silicon Graphics.
Permission to use, copy, modify, distribute, and sell this software and its documentation for any purpose is hereby granted without
fee, provided that the above copyright notice appear in all copies and that both that copyright notice and this permission notice
appear in supporting documentation. Neither Hewlett-Packard nor Silicon Graphics makes any representations about the suit-
ability of this software for any purpose. It is provided “as is” without express or implied warranty.
Berkeley Software Distribution (BSD) UNIX software copyright© 1982, 1986, 1988, 1993 The Regents of California. All rights
reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the
following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions, and
the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions, and
the following disclaimer in the documentation and/or other materials provided with the distribution. 3. All advertising materials
mentioning features or use of this software must display the following acknowledgement: This product includes software devel-
oped by the University of California, Berkeley, and its contributors. 4. Neither the name of the University nor the names of its
contributors may be used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBU-
TORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF
USE, DATA OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGE.
Feedback
Lucent Technologies appreciates your comments, either positive or negative, about this manual. Please send them to
Trademarks
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide iii
Trademarks
4ESS, 5ESS, A Network of Expertise, AnyMedia, APX 8000, AqueView, AUDIX,
B-STDX 8000, B-STDX 9000, ...Beyond Compare, CaseView, Cajun, CajunDocs,
CAJUNVIEW, Callmaster, CallVisor, CBX 500, CellPipe, ChoiceNet, ClearReach,
ComOS, cvMAX, DACScan, Dacsmate, Datakit, DEFINITY, Definity One,
DSLMAX, DSLTerminator, DSLPipe, DSLTNT, Elemedia, Elemedia Enhanced,
EMMI, End to End Solutions, EPAC, eSight, ESS, EVEREST,
Gigabit-scaled campus networking, Globalview, GRF, GX 250, GX 550,
HyperPATH, Inferno, InfernoSpaces, Intragy, IntragyAccess, IntragyCentral, Intuity,
IP Navigator, IPWorX, LineReach, LinkReach, MAX, MAXENT, MAX TNT,
Multiband, Multiband PLUS, Multiband RPM, MultiDSL, MultiVoice, MultiVPN,
Navis, NavisAccess, NavisConnect, NavisCore, NavisRadius, NavisXtend, NetCare,
NetLight, NetPartner, OneVision, Open Systems Innovations, OpenTrunk, P550,
PacketStar, PathStar, Pinnacle, Pipeline, PMVision, PortMaster, SecureConnect,
Selectools, Series56, SmoothConnect, Stinger, SYSTIMAX, True Access, WaveLAN,
WaveMANAGER, WaveMODEM, WebXtend, and
Where Network Solutions Never End are trademarks of Lucent Technologies Inc.
Advantage Pak, Advantage Services, AnyMedia, ...Beyond Compare,
End to End Solutions, Inter.NetWorking, MAXENT, and
NetWork Knowledge Solutions are service marks of Lucent Technologies Inc. Other
trademarks, service marks, and trade names mentioned in this publication belong to
their respective owners.
Ordering Information
You can order the most up-to-date product information and computer-based training
online at http://www.lucent.com/ins/bookstore.
Customer Service
To obtain product and service information, software upgrades, and technical
assistance, visit the eSight Service Center at http://www.esight.com. The
center is open 24 hours a day, seven days a week.
Customer Service
iv CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Finding information and software
The eSight Service Center at http://www.esight.com provides technical
information, product information, and descriptions of available services. Log in and
select a service. The eSight Service Center also provides software upgrades, release
notes, and addenda. Or you can visit the FTP site at ftp://ftp.ascend.com for
this information.
Obtaining technical assistance
The eSight Service Center at http://www.esight.com provides access to
technical support. You can obtain technical assistance through email or the Internet,
or by telephone.
If you need to contact Lucent Technologies for assistance, make sure that you have
the following information available:
Active contract number, product name, model, and serial number
Software version
Software and hardware options
If supplied by your carrier, service profile identifiers (SPIDs) associated with
your line
Your local telephone companys switch type and operating mode, such as AT&T
5ESS Custom or Northern Telecom National ISDN-1
Whether you are routing or bridging with your Lucent product
Type of computer you are using
Description of the problem
Obtaining assistance through email or the Internet
If your services agreement allows, you can communicate directly with a technical
engineer through Email Technical Support or eSight Live chat. Select one of these
sites when you log in to http://www.esight.com.
Calling the technical assistance center (TAC)
If you cannot find an answer through the tools and information on eSight or if you
have a very urgent need, contact TAC. Access the eSight Service Center at
Important safety instructions
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide v
http://www.esight.com and click Contact Us below the Lucent
Technologies logo for a list of telephone numbers inside and outside the United
States.
You can alternatively call (800) 272-3634 for a menu of Lucent services, or call
(510) 769-6001 for an operator. If you do not have an active services agreement or
contract, you will be charged for time and materials.
Important safety instructions
1 Read and follow all warning notices and instructions marked on the product or
included in the manual.
2 There are no operator serviceable parts within the unit. Refer all servicing to
trained service personnel.
3 Product installation should be performed by trained service personnel only.
4 Install only in restricted-access areas in accordance with UL1950, C22.2 No. 950,
and IEC60950
5 The maximum recommended operating ambient is 122° F (50° C). Allow
sufficient air circulation or space between units when installed in a closed or
multiple-rack assembly.
6 Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered. Installation without sufficient airflow
can be unsafe.
7 Equipment mounted in a rack should be distributed to prevent a possible
hazardous condition due to uneven loading. The rack should safely support the
combined weight of all equipment. This product weighs 8 lbs.
8 The power source has to be adequately rated to assure safe operation of the
equipment. The building installation and/or power source must provide overload
protection.
9 Protective earth (PE) connection is essential to ensure safe operation before
connecting to the power supply and telecommunication network. Do not defeat
the purpose of the grounding-type plug by modifying the plug or using an
adapter. Use an outlet tester or a voltmeter to check the ac receptacle for the
presence of earth ground. If the receptacle is not properly grounded, the
Important safety instructions
vi CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
installation must not proceed until a qualified electrician has corrected the
problem.
If the power supply is fed from a power source with no protective-earthing path
(such as in certain Nordic countries), connect an earth-grounded copper wire to
the dedicated wiring terminal marked with (PE symbol) on the chassis. The
minimum size of the wire for a Pipeline unit with rated input current not
exceeding 6A is AWG 18 and cross-sectional area 0.75 mm
2
.
Models with ac power inputs are intended for use with a single-phase three-wire
power cord (which includes earthing conductor).
For models with dc power inputs, the protective earth connection must be
established by using the dedicated earthing terminal marked with the PE symbol
or, if provided, the earthing pin of the input terminal block.
10 Models with dc power inputs must be connected to a -48V dc supply source that
is electrically isolated from the ac source in accordance with UL1950, C22.2 No.
950, and IEC60950.
11 For products installed in Nordic countries (except Central Office equipment), a
type B plug or permanent connection must be used for connections to the main
power supply.
12 Before installing wires to the dc power terminal block, verify that these wires are
not connected to any power source. Installing live wires (that is, wires connected
to a power source) is hazardous.
13 Do not allow anything to rest on the power cord, and do not locate the product
where people will walk on the power cord.
14 Do not attempt to service this product yourself. Opening or removing covers can
expose you to dangerous high voltage points or other risks. Refer all servicing to
qualified service personnel.
15 General purpose cables are provided with this product. Special cables, which
might be required by the regulatory inspection authority for the installation site,
are the responsibility of the customer.
16 When installed in the final configuration, the product must comply with the
applicable safety standards and regulatory requirements of the country in which
it is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
17 A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential might cause a hazardous condition. Consult
Important safety instructions
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide vii
a qualified electrical consultant to determine whether or not this phenomenon
exists.
In addition, if the equipment is to be used with telecommunications circuits, take the
following precautions:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
Avoid using equipment connected to telephone lines (other than a cordless
telephone) during an electrical storm. There is a remote risk of electric shock
from lightning.
Do not use a telephone or other equipment connected to telephone lines to report
a gas leak in the vicinity of the leak.
!
Warning: To reduce the risk of fire, communication cable conductors must be
26 AWG (0.13 mm
2
) or larger.
!
Avertissement: Afin de réduire les risques d'incendie, les fils conducteurs du
câble de communication doivent être d'un calibre minimum de 26 AWG
(American Wire Gauge), c'est-à-dire d'un minimum de 0,13 mm².
!
Warnung: Um Feuer-Risiko zu reduzieren, müsssen die Querschnitte der
Kommunikationskabel-Leiter 0,13 mm² oder größer sein.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide ix
Contents
Trademarks .............................................................................................................. iii
Ordering Information ............................................................................................... iii
Customer Service ..................................................................................................... iii
Important safety instructions ..................................................................................... v
Introduction ............................................................................. 1
New CellPipe products .............................................................................................. 1
Lucent TURN-UP ...................................................................................................... 2
Serial connection ....................................................................................................... 2
Configuring your communications software ............................................................. 2
Preparing to upgrade .................................................................................................. 3
Locating the software binary file(s) ......................................................................... 3
Power supply ............................................................................................................. 4
CellPipe IAD 4A ....................................................................... 5
Connecting a CellPipe IAD 4A unit .......................................................................... 5
Checking the activity of CellPipe IAD 4A status lights ............................................ 6
Configuring a CellPipe IAD 4A unit ......................................................................... 8
CellPipe IAD 8T ....................................................................... 9
Connecting a CellPipe IAD 8T unit .......................................................................... 9
Checking the activity of CellPipe IAD 8T status lights .......................................... 10
Configuring a CellPipe IAD 8T unit ....................................................................... 12
Connector Pinouts ................................................................ 15
TERMINAL pinouts ................................................................................................ 15
Contents
x CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
10/100 LAN connector pinouts ............................................................................... 15
T1 Connector pinouts .............................................................................................. 16
ADSL connector pinouts ......................................................................................... 16
FCC Regulations .................................................................. 17
FCC Part 15 Notice .................................................................................................. 17
IC CS-03 Notice ...................................................................................................... 18
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide 1
Introduction
New CellPipe products
The CellPipe IAD 4A and CellPipe IAD 8T are now part of the CellPipe product
line that run the IAD (Integrated Access Device) v. 2.0 software. These are integrated
access devices supporting both voice and data communications.
This Hardware Installation Guide provides information for connecting these new
units to your computer. For additional information, refer to the CellPipe™ IAD Users
Guide.
New CellPipe products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Lucent TURN-UP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Configuring your communications software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Preparing to upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Locating the software binary file(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction
Lucent TURN-UP
2 CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Lucent TURN-UP
The CellPipe IAD 4A and CellPipe IAD 8T units support the Lucent TURN-UP
automated provisioning system. TURN-Up is enabled when a user powers up his unit,
which is then automatically configured via the configuration server located at his
Internet Service Provider (ISP). TURN-UP eliminates the need for user configuration
of units and provides centralized management of configuration information.
!
Caution: If you attempt to manually configure the unit, a Delete Management Port
message will appear. If you select this option, the Lucent TURN-UP feature will be
disabled to enable you to reconfigure the unit.
Serial connection
You need to establish a serial connection to upgrade software and manually configure
the CellPipe units. Connect a serial cable (a serial communication cable designed for
connecting an external device) from your computer to the CellPipe unit. The cable
must be a high-speed cable that supports the hardware handshaking technique used by
almost all recently manufactured modems. The cable must have the appropriate
connector for connection to a serial communication port on your computer and a
DB-9 connector for connection to the TERMINAL port on the CellPipe unit.
Configuring your communications software
Use a communications program (such as HyperTerm, PROCOMM PLUS, Zterm, or
any other program that supports VT100 terminal emulation) to open a session directly
with the port to which the IAD unit is connected.
Configure your communications software with the following settings. If you are not
already familiar with the settings listed, see the documentation that accompanies your
communications software. If you are using the software for the first time, going
through an online or printed tutorial is a good way to get started.
Direct connectionIndicate that a serial cable connects the IAD directly to the
computer.
Introduction
Preparing to upgrade
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide 3
Serial portSpecify which of the computers serial ports the software uses. If the
only serial port available is currently used by an internal modem, you may need
to use your computers setup software to specify an external connector for the
port that will be used in place of the internal modem. In some cases, you also
may need to remove the modem. See the manual for the modem and your
computers user manual for details.
Terminal typeSpecify VT100.
DuplexMost communications software support full-duplex transmission by
default. If given a choice, set Full duplex.
Bits per secondSpecify 9600.
Data bitsSpecify 8.
ParitySpecify None.
Stop bitsSpecify 1.
Flow controlDisable software flow control (XON/XOFF) and, if possible,
hardware flow control (RTS/CTS).
When you establish the connection, the command-line interface appears.
Preparing to upgrade
Set up a TFTP server on the network that is accessible by your CellPipe unit prior to
upgrading the software. Also, configure an IP address on the 10BaseT port of the
CellPipe unit and test the connection to the TFTP server by pinging the server.
Locating the software binary file(s)
!
Caution: Do not upgrade to an earlier software version. Uploading older software
causes the unit to loose configuration, and you will have to return it for replacement.
You can locate the software binary file (or collection of software binary files) for the
IAD CellPipes at
ftp://ftp.ascend.com/pub/Software-Releases/CellPipe.
Introduction
Power supply
4 CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
The software loads for each CellPipe unit are different. Make certain that you
download the correct file. If you use the wrong file to upgrade, your unit will stop
functioning and you will have to restore your configuration from a backup.
Extract and save the appropriate file to the TFTP boot directory from which you will
upgrade your unit.
Power supply
All CellPipe units are shipped with a power supply. However, European users need to
purchase an additional wall outlet cable due to the regional variations in wall outlets.
Please check with your Sales Representative for the power supply and cables required
for your environment. Refer to the illustrations below.
Domestic power supply European power supply
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide 5
CellPipe IAD 4A
The CellPipe IAD 4A supports four POTS (plain old telephone service) lines over
ATM (Asynchronous Transfer Mode), PPP (Point-to-Point Protocol) over ATM,
Frame Relay or HDLC (High-Level Data Link Control) over an ADSL (asymmetrical
digital subscriber line) WAN interface. This unit supports asymmetrical transmission
and receive downstream rates of 64 Kbps to 8.1 Mbps and upstream rates of 64 Kbps
to 800 Kbps.
Connecting a CellPipe IAD 4A unit
The CellPipe IAD box you receive contains the following items:
1 CellPipe IAD unit
2 10BaseT Ethernet crossover cable (yellow)
3 ADSL WAN cable with RJ-11 modular plug connectors (blue)
4 Power supply
5 CellPipe™ IAD Users Guide
6 Hardware Installation Guide
Connecting a CellPipe IAD 4A unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Checking the activity of CellPipe IAD 4A status lights. . . . . . . . . . . . . . . . . . . . . . 6
Configuring a CellPipe IAD 4A unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CellPipe IAD 4A
Checking the activity of CellPipe IAD 4A status lights
6 CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
7 Warranty card
To connect to the CellPipe IAD 4A unit, proceed as follows:
1 Connect one end of the yellow Ethernet cable to the port labeled LAN on your
unit and the other end to the Ethernet adapter on your computer.
Note: To connect the CellPipe unit to an Ethernet hub, use a straight-through
Ethernet cable (not supplied).
2 Connect one end of the blue WAN cable to the port labeled WAN and plug the
other end into the wall jack.
3 Connect up to four telephone lines to the four POTS ports.
4 Connect the power cable to your unit.
5 Plug the other end of the power cable into a wall outlet.
Note: The unit has no power switch and connecting the power cable turns on the
CellPipe IAD unit.
Checking the activity of CellPipe IAD 4A status
lights
Observe the activity pattern of the lights on the front of the CellPipe IAD 4A unit to
verify that the unit is connected properly.
CellPipe IAD 4A
Checking the activity of CellPipe IAD 4A status lights
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide 7
When all the cables are connected, verify that the following status light behavior
takes place:
The pwr light is on initially and remains on. If not on, make sure the power
supply is properly connected.
The act light blinks during any LAN traffic. Otherwise, it remains off.
The lnk light is on if an Ethernet connection is established. If not on, check to
make sure your Ethernet cable is properly connected.
The wan light blinks until a DSL connection is established, and then it remains
on.
The con light is on only during the CellPipe IAD unit self-test and blinks when a
voice port is offhook.
CellPipe IAD 4A
Configuring a CellPipe IAD 4A unit
8 CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Configuring a CellPipe IAD 4A unit
!
Caution: If you attempt to manually configure the unit, a Delete Management Port
message appears. The unit disables Lucent TURN-UP to enable you to manually
configure the unit.
The Main menu items for the CellPipe IAD 4A unit are similar to those of other IAD
CellPipe units. Refer to the CellPipe IAD Users Guide for a discussion of the Main
menu items. The menu exception for the CellPipe IAD 4A can be found in its
Configure WAN menu.
To configure the WAN interface on the CellPipe IAD 4A unit, proceed as follows:
1 Select Configure WAN from the Main Menu.
2 Select Configure Physical Interface under the WAN Configuration
menu.
3 Set the ADSL Standard. See Table 1.
.
Table 1. ADSL ATU-R configuration menu
Menu option Description
Set ADSL Standard Current ADSL Standard: T1.413
Choose an ADSL Standard:
1. T1.413
2. G.Lite
3. G.DMT
4. Alcatel 1.4
5. Multi-Mode
6. ADI
7. Alcatel
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide 9
CellPipe IAD 8T
The CellPipe IAD 8T supports eight POTS lines over ATM, PPP over ATM, Frame
Relay or HDLC (High-Level Data Link Control) over a T1 WAN interface. This
voice-over-T1 solution supports symmetrical transmission and receive rates of 1.544
Mbps.
Connecting a CellPipe IAD 8T unit
The CellPipe IAD box you receive contains the following items:
1 CellPipe IAD unit
2 10BaseT Ethernet crossover cable (yellow)
3 T1 WAN cable (blue)
4 Power supply
5 CellPipe IAD Users Guide
6 Hardware Installation Guide
Connecting a CellPipe IAD 8T unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Checking the activity of CellPipe IAD 8T status lights. . . . . . . . . . . . . . . . . . . . . 10
Configuring a CellPipe IAD 8T unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CellPipe IAD 8T
Checking the activity of CellPipe IAD 8T status lights
10 CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
7 Warranty card
To connect to the CellPipe IAD 8T unit, proceed as follows:
1 Connect one end of the yellow Ethernet cable to the port labeled LAN on your
unit and the other end to the Ethernet adapter on your computer.
Note: To connect the CellPipe unit to an Ethernet hub, use a straight-through
Ethernet cable (not supplied).
2 Connect one end of the blue WAN cable to the port labeled WAN and plug the
other end into the wall jack.
3 Connect up to eight telephone lines to the eight POTS ports.
4 Connect the power cable to your unit.
5 Plug the other end of the power cable into a wall outlet.
Note: The unit has no power switch and connecting the power cable turns on the
CellPipe IAD unit.
Checking the activity of CellPipe IAD 8T status
lights
Observe the activity pattern of the lights on the front of the CellPipe IAD 8T unit to
verify that the unit is connected properly.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Lucent Technologies CellPipe IAD 8T Hardware Installation Manual

Category
Serial switch boxes
Type
Hardware Installation Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI