ZTE Q78-R8964S26H, Q78-R8964S2600 User manual

  • Hello! I am an AI chatbot trained to assist you with the ZTE Q78-R8964S26H User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ZXSDRR8964
TD-LTERemoteRadioUnit
UserManual
Version:V5.00
ZTECORPORATION
No.55,Hi-techRoadSouth,ShenZhen,P .R.China
Postcode:518057
Tel:+86-755-26771900
Fax:+86-755-26770801
URL:http://support.zte.com.cn
LEGALINFORMATION
Copyright©2013ZTECORPORATION.
Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor
distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten
consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby
contractualcondentialityobligations.
Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE
CORPORATIONoroftheirrespectiveowners.
Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions
aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,
titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe
useoforrelianceontheinformationcontainedherein.
ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications
coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE
CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter
herein.
ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.
UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation.
TheultimaterighttointerpretthisproductresidesinZTECORPORATION.
RevisionHistory
RevisionNo.RevisionDateRevisionReason
R1.02013–09–12Firstedition
SerialNumber:SJ-20110921170448-002
PublishingDate:2013-09-12(R1.0)
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
AboutThisManual
Purpose
ThismanualdescribesZXSDRR8964devicedescription,technicalspecications,and
maintenance.
IntendedAudience
Thisdocumentisintendedfor:
lCommissioningandmaintenanceengineer
lHardwareinstallationandsitetestingengineer
PrerequisiteSkillandKnowledge
Tousethisdocumenteffectively,usersshouldhaveageneralunderstandingofwireless
telecommunicationstechnology.FamiliaritywithLTEsystemanditsvariouscomponents
ishelpful.
WhatIsinThisManual
Thismanualcontainsthefollowingchapters:
ChapterSummary
Chapter1FCCStatementDescribestheFCCstatementrelatedtothe
device.
Chapter2ProductOverviewDescribesproductfunction,typicalapplication,
networkingmode,technicalindices,etc.
Chapter3TechnicalSpecicationDescribesproductindices.
Chapter4ProductDescriptionDescribesproductinterfaces,indicatorsand
cables.
Chapter5ProductMaintenanceDescribesproductcablereplacement.
I
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
II
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter1
FCCStatement
Note:
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigital
device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedin
acommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradio
frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,
maycauseharmfulinterferencetoradiocommunications.Operationofthisequipment
inaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwillbe
requiredtocorrecttheinterferenceathisownexpense.
Cablelossbetweentransmitterandantennais1dB.
Note:
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferencein
whichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
Note:
FCCRadiationExposureStatement:ThisequipmentcomplieswithFCCradiation
exposurelimitssetforthforanuncontrolledenvironment.Thisequipmentshouldbe
installedandoperatedwithminimumdistance8mbetweentheradiator&yourbody.
1-1
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
Thispageintentionallyleftblank.
1-2
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter2
ProductOverview
TableofContents
ZTEDistributedBaseStationSolution........................................................................2-1
RRULocationinLTEWirelessNetwork......................................................................2-2
RRUTypicalApplication.............................................................................................2-2
DeviceAppearance....................................................................................................2-3
DeviceFunctions........................................................................................................2-4
DeviceFeatures.........................................................................................................2-4
DeviceInstallationScenarios......................................................................................2-5
DeviceNetworking.....................................................................................................2-5
OperationandMaintenanceIntroduction....................................................................2-5
2.1ZTEDistributedBaseStationSolution
Tosupplythecustomerwithmorecompetitivecommunicationequipmentandsolutionin
themarket,ZTEdevelopsandpromotesZTESDRBBU(basebandunit)+RRU(remote
RFunit)distributedBSsolutiontimely,whichjointlyperformLTEBSservice.
ZTE'sLTEBBU+RRUdistributedBSsolutionhasthefollowingpredominance:
1.ClearerandSimplerNetwork
Insteadofrunninghardwareindependentplatformsforeachtechnology,operatorscan
havevariouswirelesstechnologiesimplementedinsoftwareonthesamehardware
platform.
2.LowerTCO(T otalCostofOwnership)
Fewerengineersarerequiredsincethereisasingleplatformtomanageandmaintain.
Theoperationalexpendituresarekepttominimumcomparedtorunningseveral
hardwareplatforms.
TheTCOforamobilenetworkismuchlowerinperformingupgradesforthenew
wirelesstechnologyduetomulti-technologydeploymentsupportedbySDR-platform.
3.LowerInvestmentRisk
Sincehardwareplatformscanbereused,thereissignicantlylessinvestmentrisk
fordeployinghardware.Wirelesstechnologiesdevelopsofast,andinvestingonone
technologyonlymaybringrisktooperators.SDR-basedsolutionswilldecreasethe
investmentrisksinceSDRplatformcansupportvarioustechnologies.
2-1
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
2.2RRULocationinLTEWirelessNetwork
ZXSDRR8964isacompactLTEremoteradiofrequencyunit,whichadoptsthedigital
pre-distortiontechnology,high-efciencypowerampliertechnologyandSDRtechnology.
ZXSDRR8964andBBUformanintegratedeNodeBtoaccomplishradiotransmission
withinitscoverageandcontrolradiochannels.
Figure2-1illustratesthepositionofZXSDRR8964(RRU)innetwork.
Figure2-1DeviceLocationinNetwork
2.3RRUTypicalApplication
Figure2-2illustratesthetypicalapplicationofZXSDRR8964.
2-2
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter2ProductOverview
Figure2-2RRUTypicalApplication
2.4DeviceAppearance
TheappearanceofZXSDRR8964isshowninFigure2-3.
Figure2-3DeviceAppearance
2-3
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
2.5DeviceFunctions
ZXSDRR8964hasfollowingmainfunctions:
lSupportschannelbandwidth10MHzand20MHz.
lSupportsfrequency:
à2300MHz~2400MHz
à2496MHz~2690MHz
à3400MHz~3600MHzS3500–supportedband
à3600MHz~3700MHzS3600–supportedband
lSupports2x2MIMO,4x4MIMO.
lSupportsOpticalinterface.
lSupportstimeslotswitchingpointcongurationofuplinkanddownlink.
lSupportsmeasurementandcompensationfunctionofthebertoBBU.
lSupportspowermeasurementofcarrier.
lSupportsversionmanagementfunction.
lSupportsperformancemanagementfunction.
lSupportsmalfunctionmanagementfunction.
lSupportssecuritymanagementfunction.
lSupportsoperation&maintenancefunction.
lSupportspowermanagementfunction.
lSupportstransparentchannelfunction.
lSupportsLMT.
2.6DeviceFeatures
ZXSDRR8964isasingle-modeoutdoorRRUbasedonZTESDRplatform,whichcanbe
usedwithZTE'sBBUseriesproducttoformadistributedbasestation.
ThemaincharacteristicsofZXSDRR8964aredescribedasfollows:
lUniedPlatform
ZXSDRR8964adoptsuniedSDRplatformtoprotectoperators'investmentand
supportsmoothevolution.
lHigherEfciencyforEnergySaving
àMultiplehigh-efciencypowerampliertechnologieswereused,likeCFR,DPD
andDoherty.
àZXSDRR8964adoptsnaturalcoolingdesignwithoutnoise.Atthesametime,it
cansavepowerconsumptioncomparewithtraditionalair-conditionsystem.
àUsing"BBU+RRU"solutiontoreducefeederlossandlowerpowerrequirements
ofPAtorealizegreennetwork.
lCompactDesign,EasyDeployment
àThevolumeofZXSDRR8964is17.1liters.
2-4
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter2ProductOverview
àZXSDRR8964canbeinstalledtopoleandmountedonthewall.Theexibility
ofinstallationbenetstoreducecostforoperators.
lMulti-antennaCapability
ZXSDRR8964supportsmultipleMIMOsolution.Itcanimprovedfrequencyefciency
greatlyandbringsexcellentuserexperience.
2.7DeviceInstallationScenarios
ZXSDRR8964supportswall-mountedinstallationandpole-mountedinstallation..
2.8DeviceNetworking
ZXSDRR8964isconnectedtoBBUthroughopticalberport.Itsupportsstarnetworking
mode.
TheZXSDRR8964typicalstarnetworkingtopologyisshowninFigure2-4.
Figure2-4StartNetworkingMode
2.9OperationandMaintenanceIntroduction
LMTMode
UserscanuseaLMTtoaccomplishtheoperation,maintenanceandmanagementof
ZXSDRR8964,asshowninFigure2-5.
2-5
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
Figure2-5LMTMode
NetworkManagementMode
UserscanuseNetNumenTMnetworkmanagementsystemdevelopedbyZTEto
accomplishtheoperation,maintenanceandmanagementofZXSDRR8964.NEsare
connectedtothenetworkmanagementsystemthroughTCP/IP,asshowninFigure2-6.
Figure2-6NetworkManagementMode
2-6
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter3
TechnicalSpecication
TableofContents
DimensionandWeight...............................................................................................3-1
SystemIndices...........................................................................................................3-1
PowerSupply.............................................................................................................3-2
GroundingIndex.........................................................................................................3-2
PowerConsumption...................................................................................................3-2
Reliability....................................................................................................................3-2
WorkingEnvironment.................................................................................................3-3
3.1DimensionandWeight
Table3-1liststhedimensionandweightofZXSDRR8964.
Table3-1DimensionandWeight
ItemIndex
Dimensions440mmx290mmx134mm(HxWxD)
Weight17kg
Colorlightgray
3.2SystemIndices
Table3-2liststhecapacityspecicationofZXSDRR8964.
Table3-2DeviceCapacityIndex
ItemIndex
Maximumoutputpower
S3500
l4x15W@DL:UL=2:2
l4x10W@DL:UL=3:1
S2300/S2600
l4x20W
S3600
l4x10W@DL:UL=3:1
3-1
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
ItemIndex
Frequencyband
l2300MHz~2400MHz
l2496MHz~2690MHz
l3400MHz~3600MHz(S3500)
l3600MHz~3700MHz(S3600)
Channelraster100KHz
Channelbandwidth10MHz,20MHz
PhysicalInterfaces
l2opticalinterfaces
l4antennainterfaces
l1powerinterface
l1LMTEthernetinterface
l1AISG/drycontactinterface
Antennatype4-antenna
ProtectionIP65
3.3PowerSupply
ZXSDRR8964supports-48VDC(-57VDC~-37VDC)powerinput.
3.4GroundingIndex
ThegroundingrequirementsofZXSDRR8964shouldbelessthanorequalto5Ω.The
groundingresistancecanbelessthan10Ωintheareaswherethenumberofthunderstorm
daysislessthan20ayear.
3.5PowerConsumption
ZXSDRR8964S3500TypicalPowerConsumption:
l270W:(4*10W@DLUL=3:1).
l240W:(4*15W@DLUL=2:2).
ZXSDRR8964S2300/S2600TypicalPowerConsumption:
l170W:(DL:UL=2:2).
l260W:(DL:UL=3:1).
ZXSDRR8964S3600TypicalPowerConsumption:
l260W:(4*10W@DLUL=3:1)
3.6Reliability
Table3-3liststhereliabilityindexofZXSDRR8964.
3-2
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter3TechnicalSpecication
Table3-3DeviceReliability
ItemIndex
MTBF>180,000hours
MTTR<60minutes
Systemserviceinterruptiontime<3minutes/year
Availability99.9994%
3.7WorkingEnvironment
Table3-4describesthetemperatureandhumidityrequirementsofZXSDRR8964.
Table3-4TemperatureandHumidityRequirements
WorkEnvironmentRegularUseinPlacewithoutClimaticProtection
(Outdoor)4K4/4Z5/4Z7/4B1/4C2/4S3/4M5
EnvironmentRequirement4B1
ChemicalEnvironment4C2
Storagetemperature-55to+70
Normaloperationghumidity4%to100%
Storagehumidity10%to100%
LowerTemperature-40
UpperTemperature+50
TemperatureChangerate0.5/min
AirPressure70~106kPa
Solarradiation1120W/m2
GelconditionsYes
3-3
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
Thispageintentionallyleftblank.
3-4
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter4
ProductDescription
TableofContents
DeviceInterfaces.......................................................................................................4-1
IndicatorDescription...................................................................................................4-2
Cables........................................................................................................................4-4
4.1DeviceInterfaces
TheexternalinterfacesofZXSDRR8964areshowninFigure4-1andFigure4-2.
Figure4-1ExternalInterfaces1
4-1
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
Figure4-2ExternalInterfaces2
1.AISGstandardinterface
anddrycontactinput
2.Antennainterfaces
3.Opticalinterfaces
4.Localmaintenance
interface
5.–48VDCpowerinterface
4.2IndicatorDescription
ZXSDRR8964cabinetindicatorsareshowninFigure4-3.
4-2
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
Chapter4ProductDescription
Figure4-3ZXSDRR8964Indicators
IndicatorsdescriptionsareshowninT able4-1.
Table4-1IndicatorDescriptions
IndicatorColorStatus
RUNGreenlOFF:IndicatespoweroffortheRRHisinfaultstate.
lON:IndicatespoweronbuttheRRHisinfaultstate.
lSlowblinking(1.5son,1.5soff):Indicatesthatitisinthe
initializationprocess.
lFastblinking(0.07son,0.07soff):IndicatesthattheRUDP
(TCP)isnotestablished.
lNormalblinking(0.3son,0.3soff):IndicatesthattheRRHis
runningnormally.
ALMRedlOFF:NoAlarm(notincludingVSWR,OPTalarm)
lON:Alarm(notincludingVSWR,OPTalarm)
4-3
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
ZXSDRR8964UserManual
IndicatorColorStatus
OPT1~OPT2GreenlOFF:Theopticalmodulehasnotreceivedopticalsignal,or
opticalmoduleisnotexistedetc.
lON:Theopticalmodulehasreceivedopticalsignal,but
opticallinkisnotestablished.
lBlinking(0.3son,0.3soff):Theopticallinkisestablished.
VSWRRedlOFF:NoVSWRAlarm
lON:VSWRAlarm
ACTGreenlOFF:Cellisnotestablished.
lON:Cellisestablished.
4.3Cables
4.3.1PowerCable
ZXSDRR8964adopts–48VDCpowerinput.
TheDCpowersupplycableappearanceisshowninFigure4-4.
Figure4-4DCPowerCableAppearance
4.3.2PECable
ThePEcablesofZXSDRR8964ismadeof16mm2yellow-greenwires.Thetwoendsof
thewiresarecrimpedtonakedroundterminals.
PEcableisshowninFigure4-5.
Figure4-5PECable
4.3.3OpticalFiber
OpticalberisusedtoconnectBBUandZXSDRR8964,asshowninFigure4-6.
Figure4-6OpticalFiberCable
4-4
SJ-20110921170448-002|2013-09-12(R1.0)ZTEProprietaryandCondential
/