ZTE ZXSDR BS8900 User manual

Type
User manual
ZXSDR
BS8900
CDMA
Outdoor Basestation-8900
Hardware Manual
ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
LEGAL INFORMATION
Copyright © 2006 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of
this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO-
RATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION
or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory
warranties,
representations
or conditions are dis-
claimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-in-
fringement. ZTE
CORPORATION
and
its licensors shall not be liable for damages resulting from the use of or reliance on the
information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject
matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,
the user of this document shall not acquire any license to the subject matter herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision
History
Revision No. Revision Date Revision Reason
R1.1 03/20/2009 Add information of outdoor BBU and RSU
R1.0 11/30/2008 First Edition
Serial Number: sjzl20085453
Contents
Preface
...............................................................
i
Cabinet..............................................................
1
Cabinet Technique
Feature
...............................................
1
Baseband Power Cabinet Outer Structure........................... 1
Baseband Power Cabinet Inner
Structure
........................... 2
Heat Exchanger.......................................................... 3
Transmission Equipment
(Optional)
............................... 4
Baseband
Subrack
......................................................
4
Cable Tray
.................................................................
6
Lightning Subrack....................................................... 6
Power Supply Subrack................................................. 7
Smog
Sensor .............................................................
8
RF Cabinet Outer
Structure
..............................................
8
RF Cabinet Inner Structure
..............................................
9
RF
Subrack
...............................................................11
Lightning Filter
(Optional)
...........................................12
Storage Battery Cabinet .................................................13
Modules...........................................................
15
BBU Modules.................................................................15
Control and Clock Module
(CC)
....................................15
Channel Processing Module (CH)..................................19
Fabric Switch Module (FS)...........................................23
Site Alarm Module (SA) ..............................................28
Fan Array Module (FA)................................................30
Power Module
(PM)
....................................................31
RRU Modules ................................................................34
Fan Subrack..............................................................34
Power Distribution Subrack .........................................34
Radio System Unit
(RSU)
............................................35
Power Distribution Module
(PDM)
.................................39
Fan Control Module (FCE) ...........................................40
External Cables
...............................................
43
External Cable Layout ....................................................43
Baseband Power Cabinet Input Power
Cable
......................44
Baseband Power Cabinet Grounding Cable ........................45
Baseband Cabinet and Storage Battery Connecting
Cable
...................................................................46
Baseband Subrack DC Input Power Cable..........................46
Serial Port Monitoring Cable from Power Subrack to
Baseband
Subrack
.................................................47
Baseband Subrack and RF Cabinet Connecting
Fiber
...........48
External Dry Contact of Baseband Subrack........................49
Baseband Subrack and Lightning Subrack Connecting
Cable
...................................................................53
Baseband Subrack Ethernet Cable....................................54
GPS Arrester and CC Module Connecting RF Cable..............55
Storage Battery Door Control Cable .................................55
Storage Battery Temperature Monitoring
Cable
..................56
Storage Battery Water Monitoring Cable ...........................56
E1/T1 Cable on Lightning Subrack LPU .............................56
RF Cabinet DC Input Power Cable ....................................59
GPS Antenna Feeder System
...........................
61
GPS Antenna Feeder System
Structure
.............................61
GPS Antenna ................................................................62
GPS Feeder...................................................................63
GPS Arrester.................................................................64
GPS Feeder Connector....................................................65
GPS Grounding
Kit
.........................................................66
Main Antenna Feeder
System ..........................
69
Main Antenna Feeder System
Structure
............................69
Antenna
.......................................................................75
Feeder Structure ...........................................................75
Outdoor BBU+RSU
Cabinet
..............................
77
Cabinet
........................................................................77
Outdoor BBU+RSU Cabinet Technique
Feature
...............77
Cabinet Outer Structure .............................................77
Cabinet Inner
Structure
..............................................79
Outdoor BBU Cabinet.........................................80
Outdoor RSU Cabinet.........................................81
Fan
Box
...........................................................82
Heater
.............................................................83
Heat Exchanger ................................................83
Modules .......................................................................84
Control and Clock Module
(CC)
....................................84
Channel Processing Module (CH)..................................88
Fabric Switch Module (FS)...........................................92
Site Alarm Module (SA) ..............................................97
Fan Array Module
(FA)..............................................
102
Power Module
(PM)
..................................................
103
Fan Control Module (FCE)
.........................................
106
LPU
.......................................................................
107
PSU
.......................................................................
108
APM.......................................................................
109
DPM
......................................................................
110
1X Channel Process Module with Optical Interface
(CVI)
.............................................................
112
External
Cables
...........................................................
116
External Cable Layout
..............................................
116
DC Power Cable between PSU and BBU/FCE
(PWR-91238–001)
...........................................
120
Equipment AC Input Power
Cable...............................
120
Grounding
Cable......................................................
122
Data Cable
.............................................................
122
75–ohm E1
Cable ....................................................
127
120–ohm E1 Cable
..................................................
129
100–ohm T1 Cable
..................................................
133
RSU DC Input Power Cable
.......................................
134
High-speed Cable Connecting BBU and RSU
................
135
GPS
Jumper............................................................
136
RF
Jumper
..............................................................
136
Figures
..........................................................
139
Tables
...........................................................
143
List of
Glossary..............................................
147
Preface
Confidential and Proprietary Information of ZTE CORPORATION i
ZXSDR BS8900 Hardware Manual
This page is intentionally blank.
ii Confidential and Proprietary Information of ZTE CORPORATION
C
h a p t e r 1
Cabinet
Table of Contents
Cabinet Technique
Feature
...................................................
1
Baseband Power Cabinet Outer Structure............................... 1
Baseband Power Cabinet Inner
Structure
............................... 2
RF Cabinet Outer
Structure
..................................................
8
RF Cabinet Inner Structure
..................................................
9
Storage Battery
Cabinet
.....................................................13
Cabinet
Technique Feature
ZXSDR BS8900 is featured by the following items:
1. The cabinet is painted in light grey, pleasant to eyes.
2. The
cabinet design
is
technique oriented
with
reasonable
layout
and color arrangement.
3. The cabinet is waterproof treated, equipped with a heat-dis-
sipation window, a sun shield and a base against theft and
overall sealed for dust-proof.
4. The equipments all adopt bolts connection with lap seams filled
by shielding material to make every component well contacted
and spray coated after conduction oxidation.
5. Special requirements are made on the package of important
components. Prior protection should be taken to connectors
during overall cabinet transportation.
Baseband
Power Cabinet
Outer
Structure
Figure 1 shows the baseband power cabinet outer structure.
Confidential and Proprietary Information of ZTE CORPORATION 1
ZXSDR BS8900 Hardware Manual
FIGURE 1 BASEBAND POWER CABINET OUTER
S
TRUCTURE
Cabinet dimension: 900 mm× 600
mm× 600 mm (height × width ×
depth)
Note:
It is common to place the baseband power cabinet on a storage
battery cabinet or an RF cabinet, in which case a sun shield is
needed but the base is not necessary.
Table 1 describes the components outer the baseband power cab-
inet.
TABLE 1 BASEBAND POWER CABINET OUTER COMPONENTS
D
ESCRIPTION
Component
Description
Lifting Eyes
Used in cabinet installation or removal.
Sun Shield
Prevents the equipments from sunshine.
Handle
Used to open and close the cabinet door.
Equipped with alarm lock.
Vent
Helps cabinet heat-dissipation.
Baseband
Power Cabinet
Inner
Structure
Figure 2 shows the baseband power cabinet inner structure.
2 Confidential and Proprietary Information of ZTE CORPORATION
Chapter 1
Cabinet
FIGURE 2 BASEBAND POWER CABINET INNER
S
TRUCTURE
1. Heat exchanger
2. Reserved space
3. Baseband subrack
4. Cable tray
5. Lightning subrack
6. Power supply subrack
7. File box
8. Cabinet door
Table 2
describes
the configuration inside the
baseband
power cab-
inet.
TABLE 2 BASEBAND POWER CABINET INNER STRUCTURE
D
ESCRIPTION
Unit
Height
Configuration
Heat exchanger
4 U
Compulsory
Transmission
subrack
4 U reserved
Optional
Baseband subrack
2 U
Compulsory
Cable tray
1 U
Optional
Lightning subrack
1 U
Optional
Power supply subrack
6 U
Compulsory
1 U = 4.44 cm
Heat
Exchanger
The heat exchanger has been installed inside baseband power cab-
inet before equipment consignment.
Judging from the feedback indices from temperature sensor, the
heat exchanger provides cooling or heating function to keep a sta-
ble temperature inside the cabinet and ensure the normal opera-
tion of equipments.
Confidential and Proprietary Information of ZTE CORPORATION 3
ZXSDR BS8900 Hardware Manual
The heat exchanger consists of extracting core, heater, external
ventilation fan, internal ventilation fan and control panel. Two air
channels (inner and outer) are set to implement air convection.
Figure 3 shows the heat exchanger structure.
FIGURE 3 HEAT
E
XCHANGER
S
TRUCTURE
Transmission
Equipment (Optional)
Transmission equipment is an optional configuration. The base-
band power cabinet reserves a space of 19" wide and 4 U high for
its installation.
The transmission equipment adopts - 48 V DC supply with 200 W
power consumption.
The transmission equipment completes transmission signals con-
version. ZXSDR BS8900 supports various types of transmis- sion
equipments, such as SDH, microwave, PDH optical transmis- sion
and HDSL.
Caution:
The transmission equipment demands a relatively small working
temperature range. Pay attention to the temperature in local en-
vironment for inside transmission equipment configuration since it
will decrease the BBU working temperature range.
Baseband
Subrack
Figure 4 shows the ZXSDR BS8900 baseband subrack.
4 Confidential and Proprietary Information of ZTE CORPORATION
Chapter 1
Cabinet
FIGURE 4 BASEBAND
S
UBRACK
1.
CHV
2.
CHD
3.
FA
4.
SA
5. CC
6. FS
7. PM
Table 3 describes the modules configured in the baseband subrack
slots.
TABLE 3 BASEBAND SUBRACK MODULES
D
ESCRIPTION
Module
Meaning
Quantity
Description
CHV
Channel
Processing
Module
(1x
service)
CHD
Channel
Processing
Module
(DO
service)
1~4
A single module can
support 6 CS, Their
amounts are determined
by service demands.
FA
Fan Array Module
1
SA
Site Alarm
Module
1
Supports 8 E1/T1
interfaces, 8 dry
contacts (6 outputs
and 2 two-ways), 1
expanded RS232/RS485
communication interface
and fan monitor.
CC
Control
and
Clock
Module
1~2
Supports 1+1
active/standby mode.
Both are configured only
upon specific request.
FS
Network Switch
Module
1~2
1 module is configured
as default. Supports load
sharing. Not support
active/standby mode.
PM
Power Module
1~2
1 module is configured as
default. 2 are configured
upon
specific
request.
Confidential and Proprietary Information of ZTE CORPORATION 5
ZXSDR BS8900 Hardware Manual
Cable
Tray
The cable tray locates in the baseband power cabinet and takes
up a 1 U high space.
The cable tray is used for cable wiring, management, supporting
and protection. Figure 5 shows its structure.
FIGURE 5 CABLE
T
RAY
S
TRUCTURE
Lightning
Subrack
The lightning subrack prevents the external RS232/RS485, dry
contact, E1/T1 and FE/GE interfaces of ZXSDR BS8900 out- door
transmission equipment from lightning and avoids damages to
the equipment caused by lightning induction and static electric-
ity.
The lightning subrack fulfills the following functions:
Supports lightning protection of 8 dry contacts.
Supports lightning protection of one RS232 channel and one
RS485 channel.
Supports lightning protection of 8 E1 channels.
Supports lightning protection of 2 FE/GE electrical interfaces.
The lightning subrack locates in the baseband power cabinet, an
option for configuration. Figure 6 shows the lightning subrack
panel.
FIGURE 6 LIGHTNING
S
UBRACK
P
ANEL
1. RS232/RS485_EM
2. MON_IN/OUT_GO
3. BSC_E1_GO
4. ABIS_1/ABIS_0
5. BBU_A1/BBU_A0
6.
BBU
6 Confidential and Proprietary Information of ZTE CORPORATION
Chapter 1
Cabinet
Note:
The lightning subrack configuration is unnecessary when external
dry contact and external monitor are not required for GE optical
access to Abis interface.
Power
Supply Subrack
Composed
of AC
distribution
unit, DC
distribution
unit, rectifier and
monitoring unit, the power supply subrack adopts a standard 19
inch structure with a 6 U height.
Figure 7 shows the structure of power supply subrack.
FIGURE 7 POWER SUPPLY
S
UBRACK
S
TRUCTURE
1. DC distribution unit
2. Monitoring unit
3. Rectifier
4. AC distribution unit
Table 4 lists the description of each composition unit of power sup-
ply subrack.
TABLE 4 POWER SUPPLY SUBRACK COMPOSITION UNIT
D
ESCRIPTION
Unit
Quantity
Description
AC
distribution
unit
1
Provides 2 sets of
standby
outputs
in
standard
configuration.
DC
distribution
unit
1
Provides overload protection for DC
output branch and battery branch.
Confidential and Proprietary Information of ZTE CORPORATION 7
ZXSDR BS8900 Hardware Manual
Unit
Quantity
Description
Rectifier
<=4
Adopts drawer structure with AC
single-phase 220 V input and DC -48
V/30 A output.
Monitoring unit
1
Adopts drawer structure. In charge
of integral
management
of
power
distribution
unit,
rectifier
module and
storage battery.
Smog
Sensor
The smog sensor lies in the left top corner of the RF cabinet for
detection of smog inside the cabinet.
The smog sensor is 104 mm in diameter and 47 mm in depth.
Figure 8 shows the structure of the smog sensor.
FIGURE 8 SMOG
S
ENSOR
S
TRUCTURE
The smog sensor with a ±12 V DC supply is connected to the smog
sensor interface on the panel of FCE that manages the smog alarm
and report.
RF
Cabinet Outer Structure
RF cabinet outer structure consists of the cabinet proper, cabinet
door, sun shield and the base, as is shown in Figure 9.
The cabinet dimension is 850 mm × 600 mm × 600 mm (height
× width × depth).
8 Confidential and Proprietary Information of ZTE CORPORATION
Chapter 1
Cabinet
FIGURE 9 RF CABINET OUTER
S
TRUCTURE
1. Sun shield
2. Lifting eye
3. Heat-dissipation window
4. Base
5. Handle
6. Rear cover plate
Note:
Both the sun shield and base are required when the RF cabinet is
installed alone. When the cabinets are installed in heap, the sun
shield is needed for RF cabinet in the upper layer and teh base is
needed for RF cabinet in the lower layer.
Table 5 lists the description of RF cabinet outer components.
TABLE 5 RF CABINET OUTER COMPONENTS
D
ESCRIPTION
Component
Description
Sun shield
Prevents direct sun shine.
Lifting eye
Used during cabinet installation and removal.
Heat-dissipation
window
Helps cabinet heat-dissipation.
Base
Used for cabinet fixation. Provides guard
against theft.
Handle
Used to open and close the cabinet door.
Equipped with alarm lock against theft.
Rear cover plate
Able to be disassembled and convenient for
cable connection.
RF
Cabinet Inner Structure
Figure 10 shows the RF cabinet inner structure.
Confidential and Proprietary Information of ZTE CORPORATION 9
ZXSDR BS8900 Hardware Manual
FIGURE 10 RF CABINET INNER
S
TRUCTURE
1. Fan subrack
2. Power distribution subrack
3. RF subrack
4. Base
5. Reserved for lightning filter
6. Air intake vent
7. Sun shield
10 Confidential and Proprietary Information of ZTE CORPORATION
Chapter 1
Cabinet
Table 6 describes the inner configuration of RF cabinet.
TABLE 6 RF CABINET INNER CONFIGURATION
D
ESCRIPTION
Unit
Configuration
Fan subrack
Compulsory
Power distribution subrack
Compulsory
RF subrack
Compulsory
Lightning Filter
Optional
Sun shield
Optional
Base
Optional
Note:
The RF cabinet should be equipped with both sun shield and base
when placed alone. If installed in heap with other cabinet, it needs
sun shield for upper layer and base for lower layer.
RF Subrack
Figure 11 illustrates the ZXSDR BS8900 RF subrack.
FIGURE 11 RF
S
UBRACK
1. RSU
Confidential and Proprietary Information of ZTE CORPORATION 11
ZXSDR BS8900 Hardware Manual
Table 7 describes the module configured in RF subrack slots.
TABLE 7 RF SUBRACK MODULE
D
ESCRIPTION
Module
Meaning
Quan-
tity
Description
RSU
Radio System
Unit
1~6
A single RSU supports 4
carriers. RSU number is the
same with sector number if
the carrier number <=4 and
twice the sector number if 4
<
carrier
number <=6.
Lightning
Filter (Optional)
The lightning filter locates in the RF cabinet below RSU, an option
configuration.
The lightning filter consists of 2 DC lightning protection units
(LPUs), 1 air break switch (ABS) and 2 DC filters. Figure 12 shows
its structure.
FIGURE 12 LIGHTNING
F
ILTER
S
TRUCTURE
Note:
1. Lightning filter needs to be configured when one RF cabinet is
installed alone or with a storage battery cabinet in heap or with
another RF cabinet in heap.
2. Lightning filter is unnecessary when one RF cabinet is installed
with a baseband power cabinet in heap.
12 Confidential and Proprietary Information of ZTE CORPORATION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155