Samsung OM55N-D Installation guide

Type
Installation guide

This manual is also suitable for

OMN(OM46N OM55N)
OMN-D(OM46N-D OM55N-D)
Follow the instructions provided in this guide when installing the product.
Samsung will not provide warranty coverage for problems that may arise as a result of failure to follow the guide.
The color and shape of the product may vary. In addition, instructions in the installation guide may change without prior notice when
necessary to improve the product.
Semi-Outdoor
Installation Guide
English - 2
English
Contents
OM46N / OM55N
01 Prior to Installation
Precautions for installation ------------------------------------------------------------------------------------------------------------------------ 3
Rotation and tilt angle
------------------------------------------------------------------------------------------------------------------------ 3
Clearance for installation
------------------------------------------------------------------------------------------------------------------------ 4
Air ow direction
------------------------------------------------------------------------------------------------------------------------ 5
02 Enclosure unit design guide
Inlet and outlet types ------------------------------------------------------------------------------------------------------------------------ 5
Vent opening design guide
------------------------------------------------------------------------------------------------------------------------ 6
Partition design guide
------------------------------------------------------------------------------------------------------------------------ 6
OM46N-D / OM55N-D
01 Prior to Installation
Precautions for installation ------------------------------------------------------------------------------------------------------------------------ 9
Rotation and tilt angle
------------------------------------------------------------------------------------------------------------------------ 9
Clearance for installation
------------------------------------------------------------------------------------------------------------------------ 10
Air ow direction
------------------------------------------------------------------------------------------------------------------------ 10
02 Bracket types and installation guide
Before installing brackets ------------------------------------------------------------------------------------------------------------------------ 11
Bracket types
------------------------------------------------------------------------------------------------------------------------ 13
Bracket installation
------------------------------------------------------------------------------------------------------------------------ 17
03 Enclosure unit design guide
Inlet and outlet types ------------------------------------------------------------------------------------------------------------------------ 18
Vent opening design guide
------------------------------------------------------------------------------------------------------------------------ 18
01 Prior to Installation
Precautions for installation
Semi-outdoor units are not intended for outdoor use.
Applying additional means of waterproong and cooling does not prevent
the product from overheating and malfunctioning when used in an
outdoor environment, which will not be covered by the warranty.
Do not install this product near machinery that works with oil. Oil mist may
cause fans to malfunction.
Rotation and tilt angle
Contact Samsung Customer Service Centre for further details.
15°
The product can be used in landscape or portrait orientations, at tilting
angles up to 15°from a wall surface.
OM46N / OM55N
English - 3
OM46N / OM55N
Clearance for installation
Clearance for installation by windows
When installing a semi-outdoor unit near windows, maintain the clearance in order to secure air flow.
Clearance from windows (A): 100 mm or more
Clearance from the ceiling (B): 300 mm or more
Clearance from the floor (C): 100 mm or more
Keep the ambient temperature at 0 - 30 °C, clear of obstacles that may affect air flow.
If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be
covered by the warranty.
The product may overheat when used with an enclosure unit. Make sure to contact Samsung for guidance in
using enclosure units.
A
C
B
Air-conditioner
Clearance for wall mounting
Contact Samsung Customer Service Centre for further details.
Installation requirements for wall mounting
A - at least 60 mm
B (ambient temperature measuring point) - below 30 °C
When mounting to a wall surface, the clearance between the product and the wall should
be at least 60 mm at all times and the ambient temperature should not be exceed 30 °C.
A
B
English - 4
OM46N / OM55N
Air flow direction
The semi-outdoor unit uses cooling fans to take in outside air to lower the internal temperature and discharge the hot air.
When installing a semi-outdoor unit, remove any obstacles near the air inlet and outlet that may affect air flow.
Back
Side view
Air inlet
Air outlet
02 Enclosure unit design guide
Inlet and outlet types
Air inlet and outlet should be grid or mesh types.
Do not use the louver type as it has a limited intake size.
Grid type
Mesh type
Louver type
English - 5
OM46N / OM55N
Vent opening design guide
Follow the guide when combining the semi-outdoor unit with the enclosure unit.
If the instructions provided in this guide are not observed, the cooling system may not work properly and may cause
a malfunction, which will not be covered by warranty.
The ventilation opening ratio should be minimum 50 %.
Calculating the total area of the ventilation and ventilation opening ratio
Total area of the ventilation: 181 x 89 = 16,109 mm⁲
Total open area of the ventilation holes: 20 x 20 x 32 = 12,800 mm⁲
181 mm
3 mm
20 mm
89 mm
Ventilation opening ratio:
Total open area of the ventilation holes
=
12,800 mm⁲
x 100 = 79 %
Total area of the ventilation 16,109 mm⁲
Partition design guide
For semi-outdoor units, add partitions between the inlet and outlet to keep air paths separated.
Partitions should fit perfectly inside the enclosure unit, with no gap between the semi-outdoor unit and enclosure
unit. If there is a gap, use a foam tape to fill it.
Partition
Foam tape
English - 6
OM46N / OM55N
Single enclosure unit
When using with the enclosure unit, design the semi-outdoor unit according to the following specifications to prevent
discharged hot air from flowing back into the inlet.
Design the locations of the enclosure unit inlet and outlet to match the locations of the semi-outdoor unit inlet and outlet.
Allow clearance of 60 mm or more between the product and the enclosure unit.
Total open area of the ventilation holes
OM46N OM55N
Air outlet
x 1
14,560 mm² or more each 14,560 mm² or more each
x 2
32,172 mm² or more each 42,840 mm² or more each
Air inlet
x 3
13,650 mm² or more each 13,650 mm² or more each
x 2
40,180 mm² or more each 57,120 mm² or more each
Minimum ventilation opening ratio (%): 50 % or more
Example 1 Example 2
Allow suggested clearance when designing the inlet and outlet.
OM46N OM55N
At least 100 mm At least 120 mm
At least 80 mm At least 90 mm
At least 130 mm
At least 160 mm
At least 150 mm
English - 7
OM46N / OM55N
1 x N one-side unit design
When designing the 1 x N one-side enclosure unit, add partitions between the products to keep the air paths separated.
Refer to the Vent opening design guide”. (Page 6)
Make sure there is no gap between the partitions and the enclosure unit.
Contact Samsung and guide when designing an N x M one-side enclosure unit.
Product 1
Product 2
Product 3
Partition
At least 50 mm
English - 8
OM46N / OM55N
01 Prior to Installation
Precautions for installation
Semi-outdoor units are not intended for outdoor use.
Applying additional means of waterproong and cooling does not prevent
the product from overheating and malfunctioning when used in an outdoor
environment, which will not be covered by the warranty.
Do not install this product near machinery that works with oil. Oil mist may
cause fans to malfunction.
Rotation and tilt angle
Contact Samsung Customer Service Centre for further details.
This model does not support landscape orientation.
OM46N-D / OM55N-D
English - 9
OM46N-D / OM55N-D
Clearance for installation
Clearance for installation by windows
When installing a semi-outdoor unit near windows, maintain the clearance in order to secure air flow.
Clearance from windows (A): 100 mm or more
Clearance from the ceiling (B): 300 mm or more
Clearance from the floor (C): 100 mm or more
Keep the ambient temperature at 0 - 30 °C, clear of obstacles that may affect air flow.
If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be
covered by the warranty.
The product may overheat when used with an enclosure unit. Make sure to contact Samsung for guidance in
using enclosure units.
A
C
B
Air-conditioner
Air flow direction
The semi-outdoor unit uses cooling fans to take in outside air to lower the internal temperature and discharge the hot air.
When installing a semi-outdoor unit, remove any obstacles near the air inlet and outlet that may affect air flow.
Back Side view
Air inlet
Air outlet
English - 10
OM46N-D / OM55N-D
02 Bracket types and installation guide
Before installing brackets
Perform the below steps before installing the product.
Installing the top cover
1
Install HOLDER-GUIDE x 2.
4
Place the top cover.
2
Insert the power cord into
the power IN rubber and
connect the power cord.
5
Securely position the
external IR cable and the
external ambient light
sensor at the specied
location.
3
Connect cables, e.g.
external IR cable, power
cord, HDMI cable, and
organize them as shown
in the image.
Removing handles
1
Remove the handles from
both sides of the product.
Remove the screw caps
found at the marked
locations before
installing on the ceiling
or with the stand.
2
Place the screws back into
the screw holes and fasten
them.
English - 11
OM46N-D / OM55N-D
Checking the display direction
Make sure that the “OUTDOOR” mark is facing the window.
A
The outdoor display may not be able to connect to your wired network when used alone with the indoor display
turned off. Turn the indoor display on or set the Network Standby of the indoor display to On before use.
The protruded part of the Wifi-Module (A) indicates the display direction. (INDOOR direction: left, OUTDOOR
direction: right)
Setting up Device ID
OMN-D model has separate remote sensors on the front and back sides.
Depending on the distance from the remote control or other surrounding conditions, it is possible both front and back
displays respond to the remote control signal. You can assign IDs to displays (INDOOR: 1, OUTDOOR: 2) and follow the
steps below to restrict remote control to one selected display only.
To reverse the remote controlled display after setting otherwise, first cancel the existing ID settings for the INDOOR
and OUTDOOR displays by pressing the UNSET button.
To select the INDOOR display only
1) Position the remote control facing the INDOOR IR sensor and press SET1 E on the control.
2) Position the remote control facing the OUTDOOR IR sensor and press SET1 E on the control.
To select the OUTDOOR display only
1) Position the remote control facing the INDOOR IR sensor and press SET2 E on the control.
2) Position the remote control facing the OUTDOOR IR sensor and press SET2 E on the control.
English - 12
OM46N-D / OM55N-D
Bracket types
See below images for installation examples.
Refer to Ceiling bracket specification / Stand bracket specification when designing the bracket.
The stand and bolts are not included with the product.
Example 1) Ceiling type
Securely fasten the bracket to the ceiling to prevent the product from falling.
Bracket
Example 2) Stand type
Securely fasten the bracket to the floor to prevent the product from falling.
Bracket
English - 13
OM46N-D / OM55N-D
Ceiling bracket specification
B side
(outward)
Product Bracket
2 ~ Φ10 mm
Clearance from the
ceiling
20 mm
(Space for cable
insertion)
200 mm
58 mm
69.5 mm
A-A
Cable cover
55 mm
A side
(inner)
A side
(inner)
Including the cable cover
A side
(inner)
B side
(outward)
A-A’ one side
Recommended structure thickness:
3.0 t ~ 4.0 t
Set
Φ10 mm
External Φ 20 mm
(Screw head size ↑)
Cable space
(10 mm or more)
English - 14
OM46N-D / OM55N-D
Stand bracket specification
4 ~ Φ10 mm
69.5 mm
20 mm
(Space for cable
insertion)
20 mm
(Space for cable
insertion)
OM46N-D: 548.5 mm
OM55N-D: 740 mm
50 mm
55 mm
58 mm
A-A
Product Bracket
B side
(outward)
A side
(inner)
A side
(inner)
A side
(inner)
B side
(outward)
A-A’ one side
Recommended structure thickness:
3.0 t ~ 4.0 t
Set
Φ10 mm
External Φ 20 mm
(Screw head size ↑)
Cable space
(10 mm or more)
English - 15
OM46N-D / OM55N-D
Screws for bracket installation
Use screws appropriate for the material and thickness of the bracket.
Thickness Screw Length (A)
2.0 t M8 x L18 5.9 mm
2.5 t ~ 4.0 t M8 x L20 5.5 ~ 7.0 mm
Bracket material thicknessInner structure of the product
Thickness
M8 x L18
(Thickness 1.6 t ~ 2.0 t)
10.5 mm (Cut-thru space)
34.75 mm 34.75 mm
58 mm
200 mm
Length (A): 7.0 mm
Side view
Product Bracket
English - 16
OM46N-D / OM55N-D
Bracket installation
Ceiling installation
Brackets to hold the product must be custom-designed following specific guidelines.
1
Check the display
directions (INDOOR and
OUTDOOR) to attach the
ceiling bracket sides to
the product in the right
direction.
3
Close the ceiling bracket
cover (in yellow) to hide
cables.
2
Place cables inside the
ceiling bracket.
Stand installation
Brackets to hold the product must be custom-designed following specific guidelines.
1
Check the display
directions (INDOOR and
OUTDOOR) to attach the
stand bracket sides to
the product in the right
direction.
3
Close the stand bracket
cover to hide cables.
2
Place cables inside the
stand bracket.
English - 17
OM46N-D / OM55N-D
03 Enclosure unit design guide
Inlet and outlet types
Air inlet and outlet should be grid or mesh types.
Do not use the louver type as it has a limited intake size.
Grid type
Mesh type
Louver type
Vent opening design guide
Follow the guide when combining the semi-outdoor unit with the enclosure unit.
If the instructions provided in this guide are not observed, the cooling system may not work properly and may cause
a malfunction, which will not be covered by warranty.
The ventilation opening ratio should be minimum 50 %.
Calculating the total area of the ventilation and ventilation opening ratio
Total area of the ventilation: 181 x 89 = 16,109 mm⁲
Total open area of the ventilation holes: 20 x 20 x 32 = 12,800 mm⁲
181 mm
3 mm
20 mm
89 mm
Ventilation opening ratio:
Total open area of the ventilation holes
=
12,800 mm⁲
x 100 = 79 %
Total area of the ventilation 16,109 mm⁲
English - 18
OM46N-D / OM55N-D
Single enclosure unit
When using with the enclosure unit, design the semi-outdoor unit according to the following specifications to prevent
discharged hot air from flowing back into the inlet.
Air inlet( )
Total open area of the ventilation holes: 67,000 mm⁲ or more
Minimum ventilation opening ratio (%): 50 % or more
Air outlet( )
Total open area of the ventilation holes: 67,000 mm⁲ or more
Minimum ventilation opening ratio (%): 50 % or more
Design the locations of the enclosure unit inlet and outlet to match the locations of the semi-outdoor unit inlet and
outlet.
The front and back sides of the enclosure unit must be open without glass.
Keep clear around the product and the openings on the top and bottom to ensure good air flow.
Back Side view
Air inlet
Air outlet
English - 19
OM46N-D / OM55N-D
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

Samsung OM55N-D Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI