HIGH PRESSURE DUCT SERIE H7
www.mundoclima.com
Thank you very much for purchasing our products.
Please read this manual carefully before installing
and using the unit.
Service manual
MUCHR-96-H7T
MCAC-UTSM-201503
1
Content
Part. 1 General information ............................ 2
Part. 2 Outdoor Unit ........................................ 5
Part. 3 Indoor Unit ......................................... 11
Part. 4 Installation & Troubleshooting ........ 23
Service manual
MUCHR-96-H7T
2
Part. 1 General information
1. Model Names of Indoor/Outdoor Units .................................. 3
2. External Appearance ............................................................. 3
3. Nomenclature ....................................................................... 4
Service manual
MUCHR-96-H7T
3
1. Model Names of Indoor/Outdoor Units
Type
Indoor unit
Outdoor unit
Model
Power supply
Model
Hi-static pressure
duct type
220-240V~, 1Ph,
50Hz
2. External Appearance
2.1 Indoor units
2.2 Outdoor unit
MUCHR-96-H7T (UE20259)
MUCHR-96-H7T (UI20259)
MUCHR-96-H7T
(UI20259)
MUCHR-96-H7T
(UE20259)
Service manual
MUCHR-96-H7T
4
3. Nomenclature
MU
R
C4
8H6T
--
T
: 380-415Vac, 3 Fases, 50 Hz
-
: 220-230Vac, 1 Fase, 50 Hz
T
: 380-415Vac, 3 Fases, 50 Hz
-
: 220-230Vac, 1 Fase, 50 Hz
H:
Bomba de Calor
C
: Solo Frío
Capacidad
Nominal (kBTU)
MUNDOCLIMA
R:
Super DC Inverter
X
: Multi Split Super DC Inverter
- : ON-OFF
P
: Pared
C
: Conducto
CH:
Conducto Alta Capacidad
C
S: Cassette
ST
: Suelo Techo
CO:
Columna
CN
: Consola
PO:
Portátil
V
: Ventana
E:
Ud. Exterior Multi
6:
Serie 6
5A
: Serie 5A
6M:
Ud. Interior Multi Split Serie 6
6.2:
Ud. Exterior Multi Split 2x1 Serie 6
6.3:
Ud. Exterior Multi Split 3x1 Serie 6
6.4:
Ud. Exterior Multi Split 4x1 Serie 6
6.5:
Ud. Exterior Multi Split 5x1 Serie 6
7: Serie 7
Service manual
MUCHR-96-H7T
5
Part. 2 Outdoor Unit
1. Specifications ...................................................................... 6
2. Dimension (Unit:mm) ........................................................... 7
3. Refrigerant circuit ................................................................ 8
4. Wiring Diagrams .................................................................. 9
5. Electric Characteristics ........................................................ 9
6. Sound Levels ..................................................................... 10
7. Accessories ....................................................................... 10
Service manual
MUCHR-96-H7T
6
1. Specifications
Model
Power supply
V, Ph, Hz
380-415V~, 3Ph, 50Hz
Ambient temp in cooling
°C
-1548
Ambient temp in heating
°C
-15~24
Rated input (Whole units)
W
11,700
Rated current (Whole units)
A
16
Compressor
Model
LNB53FCAMC
Type
Rotary
Brand
MITSUBISHI
Quantity
1
Capacity
kW
16.86
Input
kW
5.2
Crankcase heater
W
25
Refrigerant oil type
FV50S
Refrigerant oil charge
ml
1700+1500
Outdoor fan motor
Model
WZDK170-38G-1
Type
DC
Quantity
2
Brand
Panasonic
Insulation class
E
Safe class
IP×4
Input
W
250(up)/185(down)
Output
W
200(up)/150(down)
Rated current
A
1.7(up)/1.4(down)
Outdoor fan
Material
Plastic
Type
Axial fan
Quantity
mm
2
Diameter
mm
560
Height
170
Outdoor coil
Number of rows
2
Tube pitch(a)×
row pitch(b)
mm
21×19.4
Fin spacing
mm
1.5
Fin type
Hydrophilic fin
Tube outside diameter
mm
Ф7
Tube type
Inner groove tube
Coil length×height
mm
1080 x 756
Number of circuits
18
Outdoor air flow
m3/h
9800
Sound pressure level
dB(A)
59
Outdoor uint
Net dimension
(W×D)
mm
1120×1558×528
Packing
(W×D)
mm
1270×1720×565
Net/Gross weight
mm
147/163
Refrigerant
Type
R410A
Factory charged
kg
7.2
Throttle type
Electronic expansion valve
Design pressure (Hi/Lo)
MPa
4.4/2.6
Refrigerant piping
Liquid pipe
mm
Ф9.53
Gas pipe
mm
Ф25.4
Note:
1. The nominal cooling capacity is based on the following conditons.
Indoor temperature: 27°CDB, 19°CWB; Outdoor temperature: 35°CDB, 24°CWB.
2. The nominal heating capacity is based on the following conditons.
Indoor temperature: 20°CDB, 15°CWB; Outdoor temperature: 7°CDB, 6°CWB
3. The noise is measured in the semi noise suppression lab.
4. Specifications are subject to change without prior notice for product improvement.
MUCHR-96-H7T (UE20259)
Service manual
MUCHR-96-H7T
7
2. Dimension (Unit:mm)
1558
1120
668 206
440
400
528
494
Service manual
MUCHR-96-H7T
8
3. Refrigerant circuit
High
pressure
switch
Oi
l seperator
Oil return
capilary
Compressor
Low pressure
switch
Low pressure
liquid
accumulator can
Condensor
High pressure
liquid
accumulator
can
Electronic
expansion
valve
Evaporator
SV5
SV6
Service manual
MUCHR-96-H7T
9
4. Wiring Diagrams
5. Electric Characteristics
Model
Outdoor Unit
Power Supply
Compressor
OFM
Hz
Voltage
Min.
Max.
MCA
TOCA
MFA
MSC
RLA
KW
FLA
50
380-415V
342V
440V
/
23
40
/
15.4
0.17
1.7
Remark:
MCA: Min. Current Amps. (A) TOCA: Total Over-current Amps. (A)
MFA: Max. Fuse Amps. (A) MSC: Max. Starting Amps. (A)
RLA: Rated Locked Amps. (A) OFM: Outdoor Fan Motor.
FLA: Full Load Amps. (A) KW: Rated Motor Output (kW)
MUCHR-96-H7T (UE20259)
MUCHR-96-H7T (UE20259)
Service manual
MUCHR-96-H7T
10
6. Sound Levels
Unit Number
Model
Noise level under three speeds of fan (dB(A))
1
59
7. Accessories
Accessory name of outdoor unit
Qty.
Purpose
Connection pipe
1
Connecting pipe of system
Curved connection pipe
1
1m
1
.3m
Front
MUCHR-96-H7T (UE20259)
Service manual
MUCHR-96-H7T
Part. 3 Indoor Unit
1. Features ............................................................................ 12
2. Specifications .................................................................... 13
3. Dimensions (Unit: mm) ...................................................... 14
4. Wiring Diagrams ................................................................ 15
5. Capacity Table ................................................................... 18
6. Static Pressure Curve ........................................................ 19
7. Electric Characteristics ...................................................... 21
8. Sound Levels ..................................................................... 21
9. Accessories ......................................................................... 22
Service manual
MUCHR-96-H7T
12
I
NDOOR UNIT
A
ir supply
Air return
1. Features
1.1 Compace design & Convenient installation
Convenient installation, hidden in the ceiling, unit installation is not hindered by the location of
lighting fixtures or room structure.
Air inlet and outlet flanges are standard and easy for duct connection.
1.2 External static pressure
Three speed fan motor.
External static pressure is up to 150Pa.
The indoor air flow is up to 4800m3/h.
1.3 Flexible duct design for different room styles
Multi diffusers from one indoor unit supply airflow to multi rooms at the same time. The unit is suitable for
various applications, such as restaurants, connect halls and hotels
1.4 High efficient DC fan motor
High energy efficient thanks to the DC fan motor.
Contrast with the AC fan motor, the power consumption of DC fan
motor can reduce up to 50%.
1.5 Optimized electronic control board
Equipped with remote ON/OFF and remote Alarm connection
terminal.
Compatible with central controller CCM03/CCM30.
Equipped with a fresh air fan motor joint control terminal.
i
nspection port
indoor unit
Service manual
MUCHR-96-H7T
13
2. Specifications
Model
Power supply
V, Ph, Hz
220~240V,1Ph,50Hz
Cooling
Capacity
W
28,000
Input
W
9,000
EER
W/W
3.11
Heating
Capacity
W
31,500
Input
W
8,500
COP
W/W
3.71
Rated input
W
850
Rated current
A
4.5
Indoor fan motor
Model
\
WZDK750-38GS-W
Brand
\
Panasonic
Quantity
\
1
Speed
r/min
1200/1160/1090
Indoor coil
Number of rows
\
4
Tube pitch(a)×row pitch(b)
mm
25.4×22
Fin spacing
mm
1.5
Fin type
\
Hydrophilic aluminum fin
Tube size
mm
Ф9.52
Tube type
\
Inner grooved copper pipe
Coil(W×H)
mm
1,202×457.2
Number of circuits
\
18
Indoor air flow
m3/h
3000~4800
External static pressure
Pa
0~150
Indoor noise level
dB(A)
49~52
Refrigerant
\
R410A
Design pressure
MPa
4.4/2.6
Refrigerant pipe
Liquid side/ Gas side
mm
Ф9.52/Ф25.4
Max. refrigerant pipe length
m
50
Max. difference in level (Outdoor upper)
m
25
Max. difference in level (Outdoor lower)
m
30
Connection wire
Power wire
\
4.0mm2(outdoor) 2.5mm2(indoor)
Signal wire
\
0.75mm
2
Drain pipe size (OD)
mm
Ф31(outdoor) Ф33(indoor)
Controller
\
KJR-29B1/BK-E (Wired controller)
Operation temperature
°C
1730
Indoor unit
Dimension (WxHxD)
mm
1,470×512×775
Packing (WxHxD)
mm
1,555×545×875
Net/Gross weight
kg
83/92
Note:
1. The nominal cooling capacity is based on the following conditons.
Indoor temperature: 27°CDB, 19°CWB; Outdoor temperature: 35°CDB, 24°CWB.
2. The nominal heating capacity is based on the following conditons.
Indoor temperature: 20°CDB, 15°CWB; Outdoor temperature: 7°CDB, 6°CWB
3. The noise is measured in the semi noise suppression lab.
4. Specifications are subject to change without prior notice for product improvement.
MUCHR-96-H7T (UI20259)
Service manual
MUCHR-96-H7T
14
3. Dimensions (Unit:mm)
Air outlet duct connection screw hole location diagram
Return air duct rivet screw hole location diagram
122
194
194
272
272
254
390
1138
Service manual
MUCHR-96-H7T
15
4. Wiring Diagrams
MUCHR-96-H7T (UI20259)
Service manual
MUCHR-96-H7T
16
Service manual
MUCHR-96-H7T
17
Service manual
MUCHR-96-H7T
18
5. Capacity Table
Cooling mode:
Indoor temperature
Outdoor temperature (DB °C)
DB (°C )
WB (°C )
21.0
28.0
35.0
43.0
46.0
52.0
54.0
21.0
15.0
Tcc(kW)
28.84
27.44
26.04
24.92
24.08
22.68
21.00
Scc(kW)
21.34
21.13
20.83
20.93
20.47
19.96
18.90
S/T
0.74
0.77
0.80
0.84
0.85
0.88
0.90
PW(kW)
7.47
8.10
8.46
8.73
9.09
9.72
10.17
24.0
17.0
Tcc(kW)
29.68
28.28
26.88
25.20
24.64
23.24
21.84
Scc(kW)
22.26 22.06 21.77
21.17
20.94
20.45
19.66
S/T
0.75 0.78 0.81
0.84
0.85
0.88
0.90
PW(kW)
7.92 8.46 8.82
9.27
9.63
10.17
10.62
27.0
19.0
Tcc(kW)
30.24 28.84 28.00
26.04
25.48
24.08
22.68
Scc(kW)
22.38 22.21 21.84
21.35
21.15
20.71
19.73
S/T
0.74 0.77 0.78
0.82
0.83
0.86
0.87
PW(kW)
8.10 8.55 9.00
9.45
9.81
10.08
10.80
29.0
19.0
Tcc(kW)
30.52 29.12 28.56
26.32
25.62
24.36
22.96
Scc(kW)
25.64 24.75 24.56
23.95
24.08
23.39
22.27
S/T
0.84
0.85
0.86
0.91
0.94
0.96
0.97
PW(kW)
8.28
8.73
9.09
9.63
10.17
10.62
11.07
32.0
23.0
Tcc(kW)
30.80
29.68
29.12
26.88
26.04
25.20
23.52
Scc(kW)
26.18
25.82
25.63
25.00
25.00
24.44
23.28
S/T
0.85
0.87
0.88
0.93
0.96
0.97
0.99
PW(kW)
8.46
8.82
9.45
9.81
10.35
11.07
11.34
Notes:
1. DB = Dry Bulb Temperature (°C), WB = Wet Bulb Temperature (°C)
2. TC = Total Capacity (kW)
3. SC = Sensible Capacity (kW)
Heat pump mode:
Indoor
temperature
Outdoor temperature (DB °C / WB °C)
24/18
7/6
2/1
-5/-6
-7/-8
DB (°C)
TC(KW)
PW(kW)
TC(KW)
PW(kW)
TC(KW)
PW(kW)
TC(KW)
PW(kW)
TC(KW)
PW(kW)
15
40.95
9.18
33.08
7.91
27.09
6.80
24.57
6.38
23.00
6.04
20
39.69
10.03
31.50
8.50
25.52
7.48
23.94
6.89
22.05
6.46
27
37.17
10.63
29.61
9.18
23.94
8.08
23.31
7.48
20.79
6.97
Notes:
1. DB = Dry Bulb Temperature (°C)
2. TC = Total Capacity (kW)
3. SC = Sensible Capacity (kW)
Service manual
MUCHR-96-H7T
19
6. Static Pressure Curve
The corresponding table of electronic control dial code and static pressure range is shown below.
Before starting the operation, the installer must set the electronic control dial code based on the actual
value of the static pressure of the product .Otherwise, there will be problems.
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
ENC2
0
1
2
3
High s
tatic pressure
Code
0~50
51~80
81~120
121~150
F
actory Setting
For Se
tting Static pressure
3200 3400 3600 3800 4000 4200 4400 4600 4800
0
20
40
60
80
100
airflow(m
3
/h)
S
taticpressure
(
Pa
)
0 1
0
1
High air
Mediumair
Lowair
Static curve (ENC2)1
Service manual
MUCHR-96-H7T
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

mundoclima Series MUCHR-H7 “Duct Inverter Great Capacity” User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI