Premier Mounts PFC-OMND User guide

Type
User guide
INSTALLATION GUIDE
PFC-OMND
Premier Floor Ceiling Mount
For Samsung OM46N-D and OM55N-D
9500355 v1.2
publ. 07/15/20
Optional Base
premiermounts.com | p. 800.368.9700 | e. [email protected]
500 W Central Ave, Suite A, Brea, CA 92821 USA
Installation Guide
PFC-OMND
Page 2
INCLUDED COMPONENTS:
FLOOR WITH OPTIONAL
BASE
CEILING FLOOR TO CEILING
SUITABLE APPLICATIONS:
M5 Allen Key
(Qty: 1)
5/16 x 3” Hex
Head Lag (Qty: 4)
M8 x 16mm Button
Hex (Qty: 8)
5/16 Flat Washer
(Qty: 4)
Twist Action Finned
Anchor (Qty: 4)
Mounting Template
(Qty: 1)
Cable Management Covers (Qty: 2 Pair)
2000mm Long Bar (Qty: 1 Pair)
M8 x 35mm Button
Hex (Qty: 8)
Snap On Dome
Cap (Qty: 4)
M4 x 10mm Pan
Head (Qty: 2)
End Cap (Qty: 2) Leg (Qty: 2)
premiermounts.com | p. 800.368.9700 | e. [email protected]premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
A
Page 3
CL
CL
Viewing Height is adjustable by installing at
optional fixed mounting location.
Table shown aboved measured from bottom of
the base.
Subtract 1/4” [6.35] if using the dimension to cut
[actual length 78.65” [1997.7] ] long bar.
DETERMINE THE VIEWING HEIGHT
APPLICATIONS:
CEILING
FLOOR TO CEILING
OM46N-D Y-DIM OM55N-D
59-0 [1498.4] A54-1/8[1376.0]
64-1/8 [1628.8] B59-1/2 [1512.5]
65-7/8 [1671.8] C60-0 [1524.5]
72-0 [1828.8] D61-3/4” [1567.5]
75-1/8[1908.4] E67-7/8 [1724.5]
78-7/8[2004.2] F78-7/8[2004.2]
85-1/4” [2165.3] G82-5/8[2099.9]
85-3/4[2177.3] H89-0[2261.0]
87-3/8[2220.3] I91-1/8 [2316.0]
Y-DIM
A”
(Min)
Y-DIM
I
(Max)
From center to bottom edge
21” [532.1] for OM46N-D
24-3/4” [627.9] for OM55N-D
1/4”
[6.35]
See
Table
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
B
Page 4
CL
Viewing height is mounted
at a fixed location and can
only be adjusted by cutting
the bar.
DETERMINE THE VIEWING HEIGHT
APPLICATIONS:
FLOOR
FLOOR TO CEILING
OPTIONAL FLOOR BASE
Table shown aboved measured from bottom of the base.
Subtract 1/4” [6.35] if using the dimension to cut [actual length 78.65[1997.7] ] long bar.
1/4”
[6.35]
Y-DIM
See
Table
78-7/8 [2004.1]
Max Height
OM46N-D Y-DIM OM55N-D
55-3/8[1416.8] Standard 52[1321]
32-3/8 [832.6] Cut to lowest
postion 29[737]
From the top to center
23-1/8 [587.3] for OM46N-D
26-7/8 [683] for OM55N-D
Cut Length
in 1” increment
23.0[584.2] Max
to get to the lowest
position.
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
C
Page 5
DETERMINE THE VIEWING HEIGHT
APPLICATIONS:
FLOOR TO CEILING (USES X2 PFC-OMND).
Cutting only to fit
between the floor
and ceiling.
157-7/8[4008.4]
Max Height
Table shown aboved measured from bottom of
the base.
Subtract 1/4” [6.35] if using the dimension to cut
[actual length 78.65” [1997.7] long bar.
1/4”
[6.35]
If power and data are
routed from the ceiling,
adjustable viewing height
by installing at varies
mounting location. See
table on page 3.
If power and data are
routed from the floor, the
viewing height is mounted
at a fixed location and can
only be adjusted by cutting
the bar. See page 4.
Section Line (center)
78-7/8[2004.2]
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
1
2
Page 6
Center Mark 46
4655
55
For mounting the template
temporary in place.
USE THE TEMPLATE FOR PRE-INSTALLATION
REMOVE THE HANDLES
Finned Anchor
Concrete only
Position the template to the desired location.
Mark the mounting points based of the flat-panel
display sizes, either 46 or 55
Drill into 4 marked mounting points using specific
size bit depending on the application.
Wood Application:
Use 1/4drill bit
Concrete Application:
Make a pilot hole with 1/8
or 7/32drill bit.
Finish with 3/8 drill bit.
Use Drill Bit by
application
Snap-on
Cap
5/16 x 3 Hex Lag
Screw with 5/16
Washer
See OMN (Semi-outdoor installation guide) for further details.
12
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
3
Page 7
1. Remove the handles (if attached on the OMN-D) before proceeding.
2. Carefully transport the flat-panel display to the mount and fasten using
M8 x 35mm Button Hex screws where applicable. A minimum of 4
mounting points (2 per side) must be use to safety secure the display.
INSTALLING THE OMN-D TO THE MOUNT
2 Person
Recommended
Manually operated
material lift
(Recommended)
Floor InstallationCeiling Installation
M5 X 35
Button Hex
Shown using OMN55-D for visual clarity. Mounting location will vary based on the viewing height.
minimum of 2
mounting points
per side
minimum of 2
mounting points
per side
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
4
Page 8
FLOOR INSTALLATION
CEILING INSTALLATION
ROUTE POWER AND DATA CABLE WITHIN THE CHANNEL OF THE MOUNT.
Not to scale
Samsung OMN-D Installation
Guide must be read within
conjuction of all step within
this guide.
Route power and data along the
inner side of the raceway.
Use zip ties to securely hold the
cables inside.
Front Section View
OMN-D
Route power and data through the cable access slot
along the outer side of the bar.
Cable
access
slot
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
5
Page 9
INSTALL THE CABLE MANGEMENT COVERS
THE MOUNT IS READY.
1. Cut the vinyl covers to size if applicable.
2. Make a cutout for the power cable.
3. The endcaps are removable for ease of installation.
4. Slide in or pinch and push the vinyl covers into the raceway.
Pinch and push
into the raceway
PUSH
M4 x 10mm Pan
Head Screw
Endcap
Vinyl covers
Cutout for
the power
cable
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
PFC-OMND
X
Page 10
OPTIONAL: CUT THE BAR WITHIN RANGE
USE METAL CUTTING
SAW BLADE
Minimum Cut Length
@ 1.75” [44.5mm]
1” [25.4mm] increments
Maximum Cut Length @ 23.00 [584.2mm]
premiermounts.com | p. 800.368.9700 | e. [email protected]
Premier Mounts intends to make this manual accurate and complete. However, Premier Mounts makes no claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this
document is subject to change without notice or obligation of any kind. Premier Mounts makes no representation of warranty, expressed or implied, regarding the
information contained herein. Premier Mounts assumes no responsibility for accuracy
PREMIER MOUNTS
LIMITED LIFETIME WARRANTY
What and Who is Covered by this Limited Lifetime Warranty
Premier Mounts warrants all mounting products to be free from defects in material and workmanship for the
lifetime of the original installation of the product.
What Premier Mounts Will Do
At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is
defective. If Premier Mounts chooses to replace a defective product or part, a replacement product or part will
be shipped to you at no charge, but you must pay any related labor costs.
What is Not Covered: Limitations
Premier Mounts disclaims any liability for damage to mounts, adapters, displays, projectors, other property,
products.
NOTWITHSTANDING ANYTHING TO THE CONTRARY IN THIS WARRANTY, THIS WARRANTY IS
LIMITED TO FIVE YEARS FROM THE DATE OF PURCHASE IN THE EVENT THAT THE WARRANT-
ED PRODUCT IS COMMERCIALLY RENTED OUT.
electrical items, are backed by a 3-year warranty.
Premier Mounts disclaims all other warranties, express or implied, including warranties of merchantability and
including but not limited to, inability to use its products or labor costs for removing and replacing defective
products or parts. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.
What Customers Must Do for Warranty Service
If you discover a problem that you think may be covered by the warranty, you must report it in writing to the
address below within thirty (30) days. Proof of purchase (an original sales receipt) from the original consumer
purchaser must accompany all warranty claims. Warranty claims must also include a description of the problem,
the purchasers name, address, and telephone number. General inquiries can be addressed to Premier Mounts
Customer Service at 1-800-368-9700. Warranty claims will not be accepted over the phone or by fax.
How State Law Applies
PREMIER MOUNTS
500 W Central Ave, Suite A
Brea, CA 92821
USA & CANADA
Phone: 800-368-9700
Fax: 800-832-4888
©
PREMIER MOUNTS
ATTN: Warrenty Claims
500 W Central Ave, Suite A
Brea, CA 92821
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Premier Mounts PFC-OMND User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI