Direktronik Pro Managerad 8xPoE + 2xSFP
User Guide
Direktronik Pro Managerad 8xPoE + 2xSFP
This document applies to 20117394.20117394 is used as an example in the product figure
unless otherwise specified.
Direktronik Pro Managerad 8xPoE + 2xSFP
Packing List
When using the Switch for the first time, carefully open the packing box. The packing
box should contain the following items:
Switch *1
User Manual *1
Power Cord *1
Console Line *1
Accessories(Rack Mount Kit *2,Feet *4,Screw *8)
Note: Precision devices are built in the device, please handle them carefully to avoid
violent vibration, which may affect the performance of the device. If you find that the
equipment is damaged or any parts are lost in the process of transportation,
please inform us, we will give you a proper solution as soon as possible.
1
Chapter 1 Product Introduction
1.1 Product Overview
20117394 is a Managed PoE Switch independently developed by our company. Provides
8*10/100/1000Mbps adaptive RJ45 ports and 2*1000Mbps SFP slots, each supporting
MDI/MDIX automatic flip and wire-speed forwarding. Ports 1-8 support PoE power
supply. PoE ports automatically detect PD devices and supply power to PD devices that
comply with IEEE 802.3af/at standards. Each port has a maximum of 30W.
Direktronik Pro Managerad 8xPoE + 2xSFP
Chapter 2 Product Appearance Description
2.1 Front Panel
The front panel consists of 8*10/100/1000Mbps adaptive RJ45 ports and 2*1000Mbps
SFP slots and related indicators, as shown in the following figure:
Figure 2-1 Front panel of the 20117394
20117394 Port description:
10/100/1000Mbps RJ45 Ports
Supports 10Mbps, 100Mbps, or 1000Mbps rate adaptation, auto-DI /MDIX, and each port
has a corresponding indicator, that is, port indicators 1-8 as shown on the panel in the figure
above
1000Mbps SFP Slots
SFP slots are independent SFP slots on the right of the panel. Each port has a corresponding
indicator, that is, the indicator 9-10 on the panel in the figure above
Console Port
The Console port is used to connect to the serial port of a computer or other terminal
device and manage or configure Switches.
Reset Switch
Reset Switch is simply a Switch that can reset automatically. After long pressing for 5s, the
initial state will be restored when the hand is released.
LED Indicator
The LED indicator is used to indicate the different working status of the Switch, so that we
can check whether the Switch is working properly in time
2
Direktronik Pro Managerad 8xPoE + 2xSFP
2.2 LED Indicator
The LED indicators of the Switch are shown in the following table. Users can monitor
the work and running status of the Switch conveniently and quickly through the
following indicators:
LED
Color
Function
PWR
Green
Off:
No Power supply.
Light:
Indicates the switch has power.
SYS
Green
Off:
the system is starting or has no power.
Blink:
the system works.
PoE
Orange
Off:
No PoE powered device (PD) connected.
Light:
There is a PoE PD connected to be port, which
supply power successfully.
LNK/ACT
Green
Off:
The network is not connected
Light:
A 10/100/1000Mbps network device is connected
Blinking:
Data is being transferred
2.3 Rear panel
The rear panel of a PoE Switch shows the AC power port. The power input ranges from 100
240V AC at 50/60 Hz.
Figure -2 Rear panel of the 8-Port Gigabit+2G SFP Switch
AC power port
This is an AC power socket, connect the negative plug of the power cord to this
interface, and connect the positive plug to the AC power supply.
Lightning protection grounding pole
It is located to the left of the power interface. Please use wire grounding to prevent lightning
strike.
3
Direktronik Pro Managerad 8xPoE + 2xSFP
Chapter Installation Guide
This chapter helps users correctly install and safely use Switches.
1. Installation Precautions
Precautions: To avoid equipment damage and personal injury, observe the following
precautions:
The Switch room should be dry and ventilated, free from corrosive gases and strong
electromagnetic interference.
The humidity of the Switch equipment room should be lower than 90%. Install proper
devices when possible.
The grounding of the Switch shall comply with the grounding requirements
described in this manual, and shall be separately and well grounded.
The Switch voltage should be stable to prevent abnormal operation of the Switch
caused by power supply voltage mutation, fluctuation and other
phenomena;
Keep a proper distance between the Switch and other devices. Do not stack other
devices with the Switch.
The connection cable between the Switch and the distribution frame should be
standardized and reasonable, and the distribution frame (box) jumper wire should
be concise and clear to prevent the phenomenon of parallel lines and wires;
To avoid the danger of electric shock, do not open the chassis without
authorization; If any fault occurs, contact professional maintenance personnel.
Safety Tips:
Use a three-hole socket with safe grounding, and ensure that the PGND cable of the power socket is
properly grounded.
Ensure sufficient space for heat dissipation and ventilation of the Switch. Do not place heavy objects on
the Switch.
4
Direktronik Pro Managerad 8xPoE + 2xSFP
3.2 Installation Environment
Before installation, make sure that the proper working environment is available, including
power requirements, adequate space, proximity to other equipment to be connected, and
other equipment in place. Please confirm the following installation requirements:
Ensure the stability of the workbench and good grounding;
Check whether cables and connectors required for installation are in place (less than
100m).
Environment requirements: The operating temperature ranges from 0°Cto 40°C
and the relative humidity ranges from 5% to 90%.
.3 Installation
Desktop installation
Place the bottom of the Switch face up on a large enough stable desktop;
Tear off the attached sticky paper on the surface of the footpad and paste the footpad
into the groove at the bottom of the chassis of the Switch to prevent external
vibration;
Carefully position the Switch upright on the workbench;
Figure -Desktop Installation Diagram
Rack mounted
Check the grounding and stability of the EIA-19inch cabinet;
Fix mounting ears to both sides of the front panel of the Switch using screws. Place
the Switch on a bracket of the cabinet and move the Switch along the guide rails of
the cabinet to a proper position;
5
Direktronik Pro Managerad 8xPoE + 2xSFP
Use screws to fix mounting ears to the guide rails at both ends of the cabinet to
ensure that the Switch is securely installed on the brackets in the cabinet slots. The
mounting ear of the device is not used for weight bearing, it is only used for fixation;
When installing devices in a cabinet, brackets (fixed on the cabinet) are provided
below the device chassis to support devices.
Figure 3-2 Diagram 1 of rack installation
Figure 3-3 Diagram 2 of rack installation
3.4 Enabling the Switch
Connect the power cord, plug in, and turn on the power. After the Switch is started, the
Switch automatically initializes. If all port indicators are on and off, the system is successfully
reset. The power LED indicator is steady on.
Note: Before powering on the device, ensure that the voltage is correct; otherwise, the
device may be damaged. (Power input range: 100-240VAC 50/60Hz).
6
Direktronik Pro Managerad 8xPoE + 2xSFP
Appendix: Technical Specifications
7
Model
Direktronik Pro
Managerad 8xPoE + 2xSFP
Standard
IEEE
802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE802.3x, IEEE
802.1X,
IEEE 802.1q, IEEE 802.1p, IEEE 802.1d, IEEE 802.1w, IEEE
802.3ad,
IEEE802.3af, IEEE802.3at
Network
Media(Cable)
10BASE
-T: UTP category 3,4,5 cable (≤100m)
100BASE
-TX: UTP category 5 cable (≤100m)
1000BASE
-T: UTP category 5e,6 cable (≤100m)
1000Base
-X: MMF or SMF SFP Module (optional)
MAC
Address Table
8K,
Auto-learning, Auto-updating
Jumbo
Frame
9216Bytes
Packet
Buffer
4.1Mbit
Transfer
Mode
Store
-and-Forward
Switching
Capacity
12Gbps
Packet
Forward Speed
14.88Mpps
PoE
Port
Port
1~8
PoE
Power on RJ45
1/
2+3/6-
PoE
Power Output
Voltage:
55V Power: 30W(Max)
Input
Power Supply
100~240V
AC50/60Hz
PoE
Power Budget
140W
Power
Supply
150W
Fan
Quantity
Fanless
Dimensions
(L*W*H)
280*180*44mm
Temperature
Operating
Temperature: 0°C ~ 40 °C
Storage
Temperature: -40 °C ~70°C
Humidity
Operating
Humidity: 10% ~90% non-condensing
Storage
Humidity: 5% ~90% non-condensing