1) Attach Mounting Plate Assemblies (A) to mounting surface using qty two (2) each ¼-20x1” socket head cap screw
fasteners (B) provided and appropriate surface anchors (not provided).
a. Mounting Plate Assemblies (A) should be spaced no further apart than 4” less than the fixture overall length.
b. Two (2) Mounting Plate Assemblies (A) are required for RHY2, RHY3, & RHY4
c. All customer supplied mounting anchors must be suitable for use in the mounting surface material, capable of
supporting fixture weight and meet all applicable building code requirements.
2) Loosen fixture Track Screws (D) located on Fixture Assembly (C) ¼ - ½ turn so that Fixture Mount Slide (E) moves
freely along Fixture track.
3) Slide Fixture Mount Slide (E) along fixture length until openings align with Mounting Plate Assembly rods.
4) Attach Fixture Mount Slide (E) to Mounting Plate Assembly rod and tighten qty two (2) each 10-32 set screws (F)
on each Mounting Plate Assembly (A).
5) Re-tighten Track Screws (D).
6) Rotate fixture to aim as required and tighten qty. two (2) each ¼-20 Slide Screws (G) on each Fixture Mount Slide (E).
MOUNTiNG ARMS
C
B
A
D
G
F
E
Mount Plate Assembly
¼-20x1” socket head cap fastener
Fixture
Track Screws
Fixture Mount Slide
10-32 Set Screws
¼-20 Slide Screws
A
B
C
D
E
F
G
WARNiNG: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
For your protection, read and follow these warnings and instructions carefully before installing this fixture. These instructions do not attempt to cover all installation
situations. If you do not understand these instructions or additional information is required, contact Hydrel Lighting or your local Hydrel Lighting distributor.
DISCONTINUED
©2014 Acuity Brands Lighting, Inc.
7/29/14
INS-RHYTHM
9144 Deering Avenue | Chatsworth, CA 91311 | www.hydrel.com
Phone: 866.533.9901 | Fax: 866.533.5291
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
iNSTALLATiON iNSTRUCTiONS
RHYTHM SERiES
1) Attach Mounting Plate Assemblies (A) to mounting surface using qty two (2) each ¼-20x1” socket head cap screw
fasteners (B) provided and appropriate surface anchors (not provided).
a. Mounting Plate Assemblies (A) should be spaced no further apart than 4” less than the fixture overall length.
b. Two (2) Mounting Plate Assemblies (A) are required for RHY2, RHY3, & RHY4
c. All customer supplied mounting anchors must be suitable for use in the mounting surface material, capable of
supporting fixture weight and meet all applicable building code requirements.
2) Loosen fixture Track Screws (D) located on Fixture Assembly (C) ¼ - ½ turn so that Fixture Mount Slide (E) moves
freely along Fixture track.
3) Slide Fixture Mount Slide (E) along fixture length until openings align with Mounting Plate Assembly rods.
4) Attach Fixture Mount Slide (E) to Mounting Plate Assembly rod and tighten qty two (2) each 10-32 set screws (F)
on each Mounting Plate Assembly (A).
5) Re-tighten Track Screws (D).
6) Rotate fixture to aim as required and tighten qty. two (2) each ¼-20 Slide Screws (G) on each Fixture Mount Slide (E).
EXTENDED ARMS & STRUTS
C
B
A
D
G
F
E
WARNiNG: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
For your protection, read and follow these warnings and instructions carefully before installing this fixture. These instructions do not attempt to cover all installation
situations. If you do not understand these instructions or additional information is required, contact Hydrel Lighting or your local Hydrel Lighting distributor.
Mount Plate Assembly
¼-20x1” socket head cap fastener
Fixture
Track Screws
Fixture Mount Slide
10-32 Set Screws
¼-20 Slide Screws
A
B
C
D
E
F
G
DISCONTINUED
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
iNSTALLATiON iNSTRUCTiONS
RHYTHM SERiES
©2014 Acuity Brands Lighting, Inc.
7/29/14
INS-RHYTHM
9144 Deering Avenue | Chatsworth, CA 91311 | www.hydrel.com
Phone: 866.533.9901 | Fax: 866.533.5291
Fixture to SSBR Surface Box Connection
1) Route fixture cord along fixture and Mounting Plate Rod (H) and secure with provided Wire Keepers (I) (J).
2) Trim excess cord at SSBR, strip back jacket approximately 4”, and slide through ½” Cord Seal (K) provided.
a. Note: ½” Cord Seal (K) may be utilized on either side of SSBR as required by installation.
3) Make electrical load connections as indicated on the labeled conductors and per all NEC and local code
requirements.
SSBR
Mounting Plate Rod
Wire Keepers
Wire Keepers
Cord Seal
H
I
J
K
J
H
I
K
WARNiNG: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
For your protection, read and follow these warnings and instructions carefully before installing this fixture. These instructions do not attempt to cover all installation
situations. If you do not understand these instructions or additional information is required, contact Hydrel Lighting or your local Hydrel Lighting distributor.
DISCONTINUED
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
iNSTALLATiON iNSTRUCTiONS
RHYTHM SERiES
©2014 Acuity Brands Lighting, Inc.
7/29/14
INS-RHYTHM
9144 Deering Avenue | Chatsworth, CA 91311 | www.hydrel.com
Phone: 866.533.9901 | Fax: 866.533.5291
6“ Min
Above Grade
6“ Min
Concrete Pedestal
(2 Places - RHY 2, 3, 4)
Location M
Fixture to BPCA/BPCB Polymeric Ground Box Connection
1) Route fixture cord along fixture and secure with provided Wire Keepers (I).
2) Trim excess cord at BPCA/BPCB, strip back jacket approximately 4”, and slide through ½” Cord Seal (K) provided.
a. Note: BPCA/BPCB must be ordered with ½” NPT at location “M” for use with Rhythm Fixtures.
3) Make electrical load connections as indicated on the labeled conductors and per all NEC and local code
requirements.
BPCA/BPCB
Wire Keepers
Cord Seal
I
K
I
K
WARNiNG: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
For your protection, read and follow these warnings and instructions carefully before installing this fixture. These instructions do not attempt to cover all installation
situations. If you do not understand these instructions or additional information is required, contact Hydrel Lighting or your local Hydrel Lighting distributor.
DISCONTINUED
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Acuity Brands Lighting HYDREL Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI