TIPS
TROUBLESHOOTING
The gate remains
closed.
The LED is OFF.
The sensor power is off.
Check the wiring and the power supply.
The gate closes and
opens constantly.
The sensor is disturbed by
the closing of the gate or
vibrations caused by the
gate motion.
Make sure the sensor is fixed properly.
Increase the tilt angle.
Reduce the field size.
Avoid proximity to neon
lamps or moving objects.
Do not cover the sensor.Avoid extreme vibrations.
GN
BN
YE
WH
A DIVISION OF BEA SA | LIEGE SCIENCE PARK | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM]
©BEA | Original instructions | 42.7937 / V3 - 08.13
BEA hereby declares that the CGS-1 2G is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2006/95/EC and 2011/65/EU.
Angleur, June 2013 Pierre Gardier, Authorized representative
The complete declaration of conformity is available on our website: www.sensorio.be
For EC countries: according to the directive 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
RELAY - NO
(
normally open)
POWER SUPPLY +
POWER SUPPLY
-
FIELD SIZE ADJUSTMENT
Drill a hole for the screw.
Fix the sensor
firmly.
Connect the wires.
MOUNTING & WIRING
max. 8 mm
MIN
MAX
MIN
MAX
d= 3.6 mm
typical shape and dimensions