The silent-angel-audio silent-angel-audio F2 Forester Linear Power Supply is a versatile power solution for audio enthusiasts seeking to enhance their audio systems. With four DC power outputs (two 12V and two 5V) and two USB ports, it can simultaneously power a wide range of audio components, including streamers, DACs, and other devices. The F2 Forester features advanced voltage regulation and ultra-low noise design to provide clean and stable power, resulting in improved audio performance and reduced background noise.

The silent-angel-audio silent-angel-audio F2 Forester Linear Power Supply is a versatile power solution for audio enthusiasts seeking to enhance their audio systems. With four DC power outputs (two 12V and two 5V) and two USB ports, it can simultaneously power a wide range of audio components, including streamers, DACs, and other devices. The F2 Forester features advanced voltage regulation and ultra-low noise design to provide clean and stable power, resulting in improved audio performance and reduced background noise.

Connection Diagram
Forester F2
Quick Start Guide
Silent Angel
• Forester F2 x1
• Power Cord x1
• 5.5mm x 2.5mm DC Plug Cable x 2
• 5.5mm x 2.1mm DC Plug Cable x 2
• User Manual x1
• Warranty Card x1
Package Contents
BE SURE TO CHECK AND SET VOLTAGE SELECTOR PROPERLY IN PRIOR TO USE.
AC Outlet
Power Cord
1DC IN2345678
5.5mmx2.1mm
DC Plug Cable
5.5mmx2.1mm
DC Plug Cable
5.5mmx2.5mm
DC Plug Cable
5.5mmx2.5mm
DC Plug Cable
N8
Z1 E1
M1 / M1T / B1 / B1T
M-IO M-LINK
DC IN ON / OFF
GbE LAN
100mA max. 100mA max.
ANALOG OUTPUTDIGITAL OUTPUT
R L
COAXIALAES / EBU
I2S
STORAGE EXPANSION
USB AUDIO
© 2021 Thunder Data Co. Ltd. All rights reserved.
support@thunder-data.com
http://www.silent-angel-audio.com/
Silent Angel
Front Panel Power Output Status Indicator
Output 1 Status(12V/3A)
When Output 1 is activated and in good connection,it shows Green Light.
When Output 1 is current overloaded,stop the power output,it shows Red Light
When the current load of Output 1 is over 90%, the power output remains normal, and it shows Red Light.
When no power signal, it shows no light.
Output 2 Status(12V/1A)
When Output 2 is activated and in good connection,it shows Green Light.
When Output 2 is current overloaded,stop the power output,it shows Red Light
When the current load of Output 2 is over 90%, the power output remains normal, and it shows Red Light.
When no power signal, it shows no light.
Output 3 Status(5V/2A)
When Output 3 is activated and in good connection,it shows Green Light.
When Output 3 is current overloaded,stop the power output,it shows Red Light
When the current load of Output 3 is over 90%, the power output remains normal, and it shows Red Light.
When no power signal, it shows no light.
Output 4 Status(5V/1A)
When Output 4 is activated and in good connection,it shows Green Light.
When Output 4 is current overloaded,stop the power output,it shows Red Light.
When the current load of Output 4 is over 90%, the power output remains normal, and it shows Red Light.
When no power signal, it shows no light.
Operating Temperature Warning Status Indicator
Left Warning Indicator
When DC 5V output working temperature is overloaded, it shows Yellow Light.
When DC 5V output working temperature is normal or no power signal, it shows no light.
Left Warning Indicator
When DC 12V output working temperature is overloaded, it shows Yellow Light.
When DC 12V output working temperature is normal or no power signal, it shows no light.
Rear Panel
Specially Designed Heat Dissipation Holes
Effectively optimize Forester F2’s heat dissipation performance.
* DO NOT connect to USB and DC plug for the same port at the same time.
AC Voltage Selection Switch
Select the suitable AC power input voltage
⑨ ⑧
⑮ ⑯
⑤ ⑥
DC Power Output
12V DC Output Port 1
12V DC output,3A maximum current output(5.5mm x 2.5mm DC plug,middle + 12V)
12V DC Output Port 2
12V DC output,1A maximum current output(5.5mm x 2.5mm DC plug,middle + 12V)
5v DC Output Port 3
5V DC output,2A maximum current output(5.5mm x 2.5mm DC plug,middle + 5V)
5v DC Output Port 4
5V DC output,1A maximum current output(5.5mm x 2.5mm DC plug,middle + 5V)
5v DC Output Port 4
5V DC output,1A maximum current output(USB2.0,Type A – Female Connector)
5v DC Output Port 3
5V DC output,2A maximum current output(USB2.0,Type A – Female Connector)
Power Switch
Power on / off control
Fuse Holder
Contain 2 fuses inside
AC Input
AC power input
AC Power Input
The same set of USB ports and DC plugs of 5V output cannot be
connected simultaneously. (The two sets share the same current output)
The maximum current gross output of two 12V ports is 3A, which means
if you connect 12/3A port to a device which requires exactly 12/3A input,
then the 12V/1A port cannot be used.
The maximum current gross output of two 5V ports is 2A, which means
if you connect 5V/2Aport to a device which requires exactly 5V/2A input,
then the 5V/1A port cannot be used.
Warnings
3.
2.
1.
  • Page 1 1
  • Page 2 2

silent-angel-audio silent-angel-audio F2 Forester Linear Power Supply User manual

Type
User manual
This manual is also suitable for

The silent-angel-audio silent-angel-audio F2 Forester Linear Power Supply is a versatile power solution for audio enthusiasts seeking to enhance their audio systems. With four DC power outputs (two 12V and two 5V) and two USB ports, it can simultaneously power a wide range of audio components, including streamers, DACs, and other devices. The F2 Forester features advanced voltage regulation and ultra-low noise design to provide clean and stable power, resulting in improved audio performance and reduced background noise.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI