1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
MATERIAL:
FINISH:
t: +44 (0) 1722 744 594 f: +44 (0) 1722 742 096 e: sales@wallgate.com w: www.wallgate.com Company Reg No. 156022
THIS DRAWING IS THE PROPERTY OF WALLGATE LIMITED AND IS ISSUED ON THE STRICT UNDERSTANDING THAT THE INFORMATION CONTAINED WILL NOT BE REPRODUCED, COPIED OR USED WITHOUT PRIOR AGREEMENT OF WALLGATE LTD.
A3
Limits: (unless stated)
` 0.25mm (sheetmetal)
` 0.10mm (machined)
` 2.00mm (pattern)
` 5.00mm (moulded)
c
O Copyright
Model/Client/Project:
TITLE:
Drg No: SCALE:
All dimensions in mm,
All angles 90~(unless stated)
3rd
SHEET 4 OF
INS-PSH-30-R
2022
1 : 9
5
REMOTE MOUNTED PSH-30
REVISION HISTORY
REV DATE DESCRIPTION BY CHKD
1 17/10/2022 CREATED AG LP
NOTES:
1. THIS SHEET SHOWS A REMOTE MOUNTING POSITION FOR THE CONTROL MODULE WITH THE AIR CONNECTED TO THE FASCIA
THROUGH AN LONG FLEXIBLE AIR HOSE. THIS FACILITY ALLOWS THE CONTROL MODULE TO BE MOUNTED IN A VARIETY OF DIFFERENT
POSITIONS TO SUIT SITE REQUIREMENTS. (PLEASE NOTE: IF THIS INSTALLATION METHOD IS REQUIRED IT MUST BE REQUESTED
WHEN THE ORDER IS PLACED SO THAT THE APPROPRIATE CONNECTIONS CAN BE SUPPLIED.)
2. THE FASCIA REQUIRES A WALL APERTURE OF 375mm WIDTH BY 380mm HEIGHT.
3. THE SOAP CONTAINER HANGS ON A BRACKET THAT CAN BE WALL MOUNTED TO SUIT REQUIREMENTS ON SITE.
4. THE BASIN WASTE PIPE SHOULD BE CONNECTED TO A 1 1/2 " (40mm NOMINAL) DEEP SEAL WASTE TRAP (NOT SUPPLIED), A RUNNING TRAP IS NOT RECOMMENDED FOR THIS PRODUCT.
5. A WATER SUPPLY OF MINIMUM 1.0 Bar IS REQUIRED FOR CONNECTION TO THE WATER INLET ON THE FRONT OF THE UNIT. THE SUPPLY IS TO BE ROUTED THROUGH THE PROVIDED ISOLATOR VALVE.
6. THE CONTROL MODULE IS SUPPLIED WITH A 2 METER CABLE WITH EXPOSED ENDS FOR CONNECTION TO A 230v AC 50Hz 13Amp ELECTRICAL SUPPLY.
7.THE WATER HEATER SUPPLIED WITH 0.7M FLYING LEAD TO BE INSTALLED INTO A SEPARATE 230v AC 50Hz 13Amp FUSED SPUR AS PER ZIP ES3 MANUAL.
8. FULL INSTALLATION DETAILS CAN BE FOUND IN THE PSH_30 PRODUCT MANUAL SUPPLIED WITH THIS PRODUCT.
9. THE FASCIA CAN CAN BE MOUNTED IN WALLS BETWEEN 13mm AND 175mm THICK. LONGER STUD BARS CAN BE PURCHASED FOR INSTALLATION INTO THICKER WALLS.
10. ENSURE 100mm CLEARANCE ABOVE THE AIR INTAKE TO ENSURE ADEQUATE AIRFLOW TO THE UNIT.
WALL (NOTE 9)
ISOLATOR TAP
(HAND WASH)
FLEXIBLE AIR HOSE
2.5 LITRE SOAP
CONTAINER
MOUNTED REMOTELY
FASCIA
1.5" (NOMINAL 40mm)
WASTE PIPE TAIL
230vAC 50Hz POWER
CONNECTION
SWITCHED FUSED
SPURS NOT SUPPLIED
CONTROL MODULE
MOUNTED ON
ADJACENT WALL