Schreder OWLET IV User manual

Type
User manual

Schreder OWLET IV is a luminaire controller that allows for remote monitoring and control of streetlights. It connects to the luminaire via a NEMA socket and communicates with the Schreder CMS platform over a wireless network. With OWLET IV, users can adjust light levels, monitor energy consumption, and detect faults, all from a central location. It also supports sensor-based control, allowing lights to be dimmed or turned off when no motion is detected. Additionally, OWLET IV enables self-testing and sensor testing, making it easy to verify proper functionality and identify any issues.

Schreder OWLET IV is a luminaire controller that allows for remote monitoring and control of streetlights. It connects to the luminaire via a NEMA socket and communicates with the Schreder CMS platform over a wireless network. With OWLET IV, users can adjust light levels, monitor energy consumption, and detect faults, all from a central location. It also supports sensor-based control, allowing lights to be dimmed or turned off when no motion is detected. Additionally, OWLET IV enables self-testing and sensor testing, making it easy to verify proper functionality and identify any issues.

www.schreder.com
DOC-0022808 OWLET IV NEMA SAM-INS-A | 06-2023 1/5
Copyright © Schréder S.A. 2022 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
MAX. 500M
1 DATALIFT : 10 MESH
MESHNODES
DATALIFT
MAX. 100M
OWLET IV
Installation Instructions
NEMA
Luminaire Controllers
DATALIFT N MESHNODE N
BEST LOCATION, RATIO & DISTANCE
90.7mm
3.57in
Ø 92.2mm
3.63in
72.9mm
2.87in
Ø 92.2mm
3.63in
Ta: -40°C to +65°C
-40°F to +149°F
Mains voltage: 110-240V
Frequency: 50/60Hz
Max load current: 5A
XX/XX
FW: X.X.X.X
SN: XXXXXXXXXXXXXXXX
XX/XX
FW: X.X.X.X
SN: XXXXXXXXXXXXXXXX
Red bottom Grey boom
Ta: -40°C to +65°C
-40°F to +149°F
Mains voltage: 110-240V
Frequency: 50/60Hz
Max load current: 5A
kg
lb
0.23kg
0.51lb
kg
lb
0.18kg
0.40lb
QR code to
access the online
installation
instruction.
PRODUCT
DATALIFT N MESHNODE N
IP
66
IK
08
XXXX
pendiente
XXXX
pending
www.schreder.com
DOC-0022808 OWLET IV NEMA SAM-INS-A | 06-2023 2/5
Copyright © Schréder S.A. 2022 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
Align the controller power
pins with slots in the
socket.
2
1Before installation
contact Schréder FAE
(Field Application Engineer) for
support.
FAE
Q
A
INSTALLATION
4
Align the longer pin (Neutral)
rst.
Check if the surfaces
between the controller and NEMA
socket are parallel and plug in.
//
5 6
± 55 N
(12.5 lbf)
3Turning indications on top
of controller.
Controller
NEMA Socket
Hold controller.
Push the controller rmly down.
Make sure it is vertically aligned.
Correct position:
vertical
Incorrect position:
twisted
12
During installation, ensure correct body position
over the luminaire.
www.schreder.com
DOC-0022808 OWLET IV NEMA SAM-INS-A | 06-2023 3/5
Copyright © Schréder S.A. 2022 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
Symbol on controller and gasket
are aligned.
NEMA socket with internal RFID
NEMA socket with external RFID
Symbol on controller and socket label
are aligned.
Turn controller ± 45°
clockwise until
it locks.
7
4.5 N.m
(3.3 lbf.)
INSTALLATION
8
9
Pull the controller up
to check if it is locked
Mechanical Verication
Visual Verication
10
Correct installation:
Surfaces of controller and
NEMA socket are parallel.
Incorrect installation:
Surfaces of controller and
NEMA socket are twisted.
VERIFICATION The installer is responsible for verifying the installation.
Extra barcode labels are supplied with the controller
Inside
pole door
Example list and map.
www.schreder.com
DOC-0022808 OWLET IV NEMA SAM-INS-A | 06-2023 4/5
Copyright © Schréder S.A. 2022 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
SELF-TEST
11
100% 10%
30 seconds
100% 10%
120 minutes
12 3
45
6
When powering on luminaire,
the light switches ON to
maximum level.
The controller
reduces light to
minimum level.
The controller
switches OFF the
light completely.
Note: the self-test occurs only in the rst 5 power cycles after installing the controller.
100% 10%
30 seconds
100% 10%
120 minutes
12 3
4
5
6
OPTIONAL SENSOR TEST
trigger a sensor dectection in the luminaire
100% 10%
30 seconds
100% 10%
120 minutes
12 3
4
5
6
Correct:
Light level changes
from max to min
Incorrect:
Light level does
not change
After the self-test, the
luminaire operates as
congured on the CMS
platform.
100% 10%
30 seconds
100% 10%
120 minutes
12 3
45
6
120 minutes
Correct
Luminaire is ON
Incorrect
Luminaire is OFF
Built-in LED
controller is ON
www.schreder.com
DOC-0022808 OWLET IV NEMA SAM-INS-A | 06-2023 5/5
Copyright © Schréder S.A. 2022 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
Certication
12 South America
MESHNODE N SAM
FCC ID: 2AW4F-OW4NMSAM
Contains FCC ID: QOQMGM13P
No changes shall be made to the device without the manufacturers permission as this may void the user’s
authority to operate the device.
The MESHNODE N SAM complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment.
The MESHNODE N SAM complies with the safety requirements for RF exposure for mobile (>20 cm) use
conditions in accordance with FCC rule part 2.1091.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
XXXX
pending
DATALIFT N SAM
FCC ID: 2AW4F-OW4NDSAM
Contains FCC ID: QOQMGM13P
Contains FCC ID: XMR202106EG91AUX
No changes shall be made to the device without the manufacturers permission as this may void the user’s
authority to operate the device.
The DATALIFT N SAM complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment.
The DATALIFT N SAM complies with the safety requirements for RF exposure for mobile (>20 cm) use
conditions in accordance with FCC rule part 2.1091.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
XXXX
pending
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Schreder OWLET IV User manual

Type
User manual

Schreder OWLET IV is a luminaire controller that allows for remote monitoring and control of streetlights. It connects to the luminaire via a NEMA socket and communicates with the Schreder CMS platform over a wireless network. With OWLET IV, users can adjust light levels, monitor energy consumption, and detect faults, all from a central location. It also supports sensor-based control, allowing lights to be dimmed or turned off when no motion is detected. Additionally, OWLET IV enables self-testing and sensor testing, making it easy to verify proper functionality and identify any issues.

Ask a question and I''ll find the answer in the document