luminii SD-3 User manual

Type
User manual

The luminii SD-3 is a versatile downlight suitable for wet locations and airtight installations, featuring inherent protection against overheating. It operates on 24 volts DC, requiring a Class 2 power unit for safe operation. With its IC rating, the SD-3 can be installed directly against combustible materials without the need for a separate housing, simplifying installation and ensuring code compliance.

The luminii SD-3 is a versatile downlight suitable for wet locations and airtight installations, featuring inherent protection against overheating. It operates on 24 volts DC, requiring a Class 2 power unit for safe operation. With its IC rating, the SD-3 can be installed directly against combustible materials without the need for a separate housing, simplifying installation and ensuring code compliance.

Stenos Downlight - Installation Instructions
Models SD-3, SD-5, SD-12
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. TYPE IC, INHERENTLY PROTECTED
5. SUITABLE FOR WET LOCATION (COVERED CEILING)
6. AIRTIGHT PER ASTM E283
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.7
09012023
1 / 5
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
REV0.3 02102021
Instruction page index:
Retrofit Installation
New Install Installation
Additional Information
2
3-4
5
1
1
2
2
S
S
t
t
e
e
n
n
o
o
s
s
D
D
o
o
w
w
n
n
l
l
i
i
g
g
h
h
t
t
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read all instructions prior to installation and keep for future reference!
Page 1 of 6
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
11..PRODUCT TO BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
22..USE ONLY WITH CLASS 2 POWER UNIT
33..24 VOLTS DC
44..SUITABLE FOR WET LOCATIONS
55..COVERED CEILING MOUNT ONLY
66..TYPE IC, INHERENTLY PROTECTED
77..FOR CANADA, VAPOR BARRIER MUST BE SUITABLE
FOR 90° C
88..ACCESS ABOVE CEILING REQUIRED
Models SD-3-XX-SO-15-XX, SD-5-XX-SO-15-XX, SD-12-XX-SO-15-XX
Stenos Downlight - Installation Instructions
FOR AIRTIGHT
REQUIREMENTS
1
2
Mounting Method 1: Retrofit Install
1.1
1.2
2.1
2.2
2.2
Note: For airtight requirements add a small
amount of silicone sealant all along the inside of
the recessed flange
Stenos Downlight - Installation Instructions
Models SD-3, SD-5, SD-12
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. TYPE IC, INHERENTLY PROTECTED
5. SUITABLE FOR WET LOCATION (COVERED CEILING)
6. AIRTIGHT PER ASTM E283
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.7
09012023
2 / 5
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
1.1 Once the desired location is determined, place the retrofit plate
onto ceiling. Followed by fastening screws into the plate holes.
If aligning multiple retrofit plates to a surface, use the alignment
tabs as a guide to help keep things aligned.
1.2 Using a spiral saw (cutout tool) or utility knife trace the inside rectangle
shape. Followed by knocking out that section. Then remove and discard the
retrofit plate.
Conductor Color Code:
Red = 24VDC Positive (+)
Black = Negative (-)
Red = Common 24VDC Positive (+)
Black = Warm White Negative (-)
White = Cool White Negative (-)
Static White
Dynamic White
2.1 Run the fixture lead wires through the cutout slot,
to the remote power supply. Follow the conductor
color coding. Reference power supply instruction
for additional information.
2.2 Rotate the fixture spring clips into the top position, to allow
fixture to slide through the cutout slot. Followed by carefully
releasing spring clips and push the fixture completely into
the slot. If necessary make any surface or paint imperfection
prior to installation.
1
2
Mounting Method: Plaster Frame Hanger Bar Plate Installation
1.1
1.1
2.1
2.2
Stenos Downlight - Installation Instructions
Models SD-3, SD-5, SD-12
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. TYPE IC, INHERENTLY PROTECTED
5. SUITABLE FOR WET LOCATION (COVERED CEILING)
6. AIRTIGHT PER ASTM E283
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.7
09012023
3 / 5
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
1.1 Align the plaster plate adjustable arms to the ceiling joist,
followed by fastening a screw to each arm. The adjustable
arms can be spread apart from 16.0” to 24.0”. If aligning
multiple plaster plates to a surface, use the alignment tabs
as a guide to help keep things aligned.
2.1 Install the 1/2” - 5/8” surface to the ceiling joist.
2.2 Using a spiral saw (cutout tool) or utility knife cut around the plaster plate trim. Followed by knocking out that surface section.
FOR AIRTIGHT
REQUIREMENTS
3
Mounting Method: Plaster Frame Hanger Bar Plate Installation
Stenos Downlight - Installation Instructions
Models SD-3, SD-5, SD-12
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. TYPE IC, INHERENTLY PROTECTED
5. SUITABLE FOR WET LOCATION (COVERED CEILING)
6. AIRTIGHT PER ASTM E283
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.7
09012023
4 / 5
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Conductor Color Code:
Red = 24VDC Positive (+)
Black = Negative (-)
Red = Common 24VDC Positive (+)
Black = Warm White Negative (-)
White = Cool White Negative (-)
Static White
Dynamic White
3.1 Run the fixture lead wires through the cutout slot, to
the remote power supply. Reference power supply
instruction for additional information.
3.2 Rotate the fixture spring clips into the top position,
to allow fixture to slide through the cutout slot.
Followed by carefully releasing spring clips and
push the fixture completely into the slot. If necessary
make any surface or paint imperfection prior to
installation.
Note: For airtight requirements add a small
amount of silicone sealant all along the inside of
the recessed flange
A
B
Mounting Method: Plaster Frame Hanger Bar Plate Installation
A.1
A.2
B.1
Stenos Downlight - Installation Instructions
Models SD-3, SD-5, SD-12
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. TYPE IC, INHERENTLY PROTECTED
5. SUITABLE FOR WET LOCATION (COVERED CEILING)
6. AIRTIGHT PER ASTM E283
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.7
09012023
5 / 5
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
A.1 Optional lens accessories can
simple snap into fixture head to
secure.
A.2 If needed: lens accessory can
be removed by mini metal prybar
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

luminii SD-3 User manual

Type
User manual

The luminii SD-3 is a versatile downlight suitable for wet locations and airtight installations, featuring inherent protection against overheating. It operates on 24 volts DC, requiring a Class 2 power unit for safe operation. With its IC rating, the SD-3 can be installed directly against combustible materials without the need for a separate housing, simplifying installation and ensuring code compliance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI