Kogan KA26VAC90EB extends the reach of your 2.6kW Vertical Window Air Conditioner by 90cm, allowing for installation in windows with a wider opening. Made for domestic use, it features a sturdy build to support the weight of the air conditioner without increasing noise and vibration. It also ensures proper airflow and cooling throughout the room and can be easily attached to the standard frame provided with your Kogan air conditioner. For safety, please ensure the window is strong and doesn't vibrate in windy conditions.

Kogan KA26VAC90EB extends the reach of your 2.6kW Vertical Window Air Conditioner by 90cm, allowing for installation in windows with a wider opening. Made for domestic use, it features a sturdy build to support the weight of the air conditioner without increasing noise and vibration. It also ensures proper airflow and cooling throughout the room and can be easily attached to the standard frame provided with your Kogan air conditioner. For safety, please ensure the window is strong and doesn't vibrate in windy conditions.

90CM EXTENSION BRACKET
FOR 2.6KW VERTICAL WINDOW AIR CONDITIONER
KA26VAC90EB
Ensure to read all instructions in this user guide prior to first use. Retain this user guide for
future reference. Misuse may cause injuries to people and damage property.
Install the equipment correctly to ensure the required space size, including the
minimum allowable distance to adjacent structures.
Do not install the air conditioner where flammable gases leak (for example, propane,
acetylene.
Keep at least a one metre clearance between any electronic devices (for example,
televisions and radios) and the air conditioner.
Do not place anything near the air outlet as this will reduce performance and
increase noise.
If you hear abnormal sounds while using the air conditioner, stop use and contact
help.Kogan.com for assistance.
Do not install in commercial areas. This bracket is designed for domestic use.
Installing it elsewhere may cause malfunctions.
Do not use any extension cords.
Do not connect the power cord of the air conditioner to other electrical equipment as
this may cause danger.
If there are two power sockets, use them separately and check if the outlet is 220V,
and 16A or higher.
If the electrical capacity of the indoor wiring exceeds the allowable capacity, this may
cause fire, electric shock or overheating of the power plug of the air conditioner.
Images used in this user guide are for reference only.
90cm extension bracket (x1)
10mm ST5 screws (x4)
10mm ST4 screws (x2)
User guide (x1)
SAFETY & WARNINGS
COMPONENTS LIST
Location
Choose a location that can withstand the weight of the air conditioner without
increasing noise and vibration.
Install it near the entrance and exit where there is no obstruction to airflow and the
entire room can be cooled.
Keep at least a one metre clearance between any electronic devices (for example,
televisions and radios) and the air conditioner.
Be sure that the hot/cold air and noise will not disturb your neighbours.
Do not place anything near the air outlet of the air conditioner as this will reduce
performance and increase noise.
Ensure there are no heat sources near the location where the air conditioner will be
installed.
Ensure windows are strong and do not vibrate during windy conditions.
Do not install the air conditioner in a location that will result in the hot air blowing
from the back of the unit to blow into windows of adjacent housing/buildings.
Do not install in an area where flammable gases are present.
Electrical safety
Standards must be adhered to for electrical and groundwork. For more information, consult
help.Kogan.com for support.
Installation of earth and earth leakage circuit breakers
Grounding work and earth leakage breakers are required to prevent electric shock.
BEFORE INSTALLATION
Do not connect the ground wire in the following places:
Gas pipes
Water pipes
Lightning rods, ground wires, and telephone lines
Window size requirements
To use the 90cm extension bracket, it must be attached onto the standard frame provided
with the Kogan 2.6kW Vertical Window Air Conditioner.
The opening width of the window should be wider than 46cm.
The height of the window opening must be between 180235cm.
Window type
Window frames should have grooves.
If there are no grooves, or the location is difficult to install, contact help.Kogan.com
for support.
180235cm
1. Using a Phillips head screwdriver (not supplied), remove the two plate fixing screws (1)
and nuts (2) from the fixing plate at the bottom of the standard frame. Remove the
fixing plate.
2. Align the holes on the fixing plate onto those on the bottom of the extension bracket.
Using a Phillips head screwdriver, secure the plate fixing screws and nuts to attach
the fixing plate to the extension bracket.
3. Use a Phillips head screwdriver to remove the four bottom plate fixing screws (3) on
the standard frame. This will detach the bottom of the standard mounting bracket.
1
2
1
2
3
INSTALLATION
4. Align the holes on the side of the extension bracket with those on the side of the
standard frame. Use a Phillips head screwdriver to secure the four fixing screws (3)
through the holes, connecting the extension bracket to the standard frame.
5. Using two 10mm ST4 screws (4), connect the top plate of the extension bracket to
the bottom plate of the standard frame.
6. Once attached, follow the installation method found in the user guide for the Kogan
2.6kW Vertical Window Air Conditioner.
Note that as opposed to attaching the bottom of the standard frame to the window,
the bottom of the extension bracket is attached instead.
Note:
If the screws are broken, use the included 10mm ST5 screws.
Extension bracket
3
4
Need more information?
We hope that this user guide has given you
the assistance needed for a simple set-up.
For the most up-to-date guide for your product,
as well as any additional assistance you may require,
head online to help.kogan.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Kogan KA26VAC90EB User guide

Type
User guide

Kogan KA26VAC90EB extends the reach of your 2.6kW Vertical Window Air Conditioner by 90cm, allowing for installation in windows with a wider opening. Made for domestic use, it features a sturdy build to support the weight of the air conditioner without increasing noise and vibration. It also ensures proper airflow and cooling throughout the room and can be easily attached to the standard frame provided with your Kogan air conditioner. For safety, please ensure the window is strong and doesn't vibrate in windy conditions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI